Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.9 LAccepted-AOC 113 SURESH SHARMA NAGAR NEAR S S V ENTER COLLEGE BAREILLY 243001 | BAREILLY | UTTAR PRADESH | 243001 | L1 | Accepted-AOC Over all rates are reasonable and lowest. | |
| 2 | L2₹8.1 L+₹4,805 (0.60%)Rejected-Finance 35 A 60 RAMPUR GARDEN BAREILLY UP | BAREILLY | BAREILLY | UP | L2 | Rejected-Finance Over all rates are higher than L-1. | |
| 3 | L3₹8.3 L+₹25,337.72 (3.15%)Rejected-Finance C 3 SHAHDANA COLONY BAREILLY 243005 | BAREILLY | BAREILLY | UTTAR PRADESH | 243005 | L3 | Rejected-Finance Over all rates are higher than L-1. | |
| 4 | L4₹8.6 L+₹53,827.22 (6.68%)Rejected-Finance | L4 | Rejected-Finance Over all rates are higher than L-1. | |
| 5 | L5₹9.0 L+₹94,074.22 (11.7%)Rejected-Finance | L5 | Rejected-Finance Over all rates are higher than L-1. |
Tender Value
₹13.6 L
EMD Value
₹27,200
Closing Date
13 Mar 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE WEST BAREILLY
GE WEST BAREILLY
SPL REPAIRS TO SINGLE OFFRS ACCN (BLDG NO P-122 AND P-122F) UNDER AGE B/R-II OF GE WEST BAREILLY
2023_MES_580428_1
8094/C/E8
Open Tender
Civil Works
Item Rate
120 days
GE WEST BAREILLY
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Yes
GE WEST BAREILLY
₹27,200
Yes
GE WEST BAREILLY
24 Mar 2023
11 Feb 2023
16 Mar 2023
11 Feb 2023
13 Mar 2023
27 Feb 2023
23 Feb 2023
Amount
M & L for double charged vitrified ceramic light shade coloured tiles 10 mm thick (Square or Rectangular) polished, area of each tile not exc. 0.36 Sqm, as in floor etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tile with and including screeding 15mm thick in CM 1:6 and dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) including removal of rubbish from the permises of site to low lying area complete all as specified and directed.
M & L for double charged vitrified ceramic light shade coloured tiles 10 mm thick (Square or Rectangular) polished, area of each tile not exc. 0.36 Sqm as on vertical surface of wall such as skirting, dado, riser etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tile over and including plastering 10 mm thick in Cement Mortar 1:4 and dismantling of floor, hearth or wall tiling including cement mortar bedding (but not backing), including removal of rubbish from the permises of site to low lying area complete all as specified and directed.
M & L for Non skid ceramic coloured tiles 7 to 8 mm thick (Square or Rectangular) area of each tile exc. 0.11 Sqm but not exc. 0.18 sqm, as in floor etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tile with and including screeding 15 mm thick in CM 1:6 and dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) including removal of rubbish from the permises of site to low lying area complete all as specified and directed.
M & L for glazed ceramic coloured tiles 450 mm X 350 mm X 7 mm thick as on vertical surface of wall such as skirting, dado, riser etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tile over and including plastering 10 mm thick in Cement Mortar 1:4 and dismantling of floor, hearth or wall tiling including cement mortar bedding (but not backing), including removal of rubbish from the permises of site to low lying area complete all as specified and directed.
Taking down cement or cement lime plaster from brick or stone walls etc. including raking out joints, hacking for keys, scrubbing down with water etc. complete all as specified and directed.
M & L for rendering 15 mm thick cement plaster on other than fair faces of brick work or stone masonry surfaces with cement mortar 1:6 finished even and smooth without using extra cement complete all as specified and directed.
M & L for rendering 15 mm thick cement plaster on fair faces of brick work or concrete surfaces with cement mortar 1:4 finished even and smooth without using extra cement complete all as specified and directed.
M & L for rendering 10 mm thick cement plaster on cement concrete surfaces of ceiling with cement mortar 1:3 finished even and fair complete all as specified and directed.
M & L for preparation of newly plastered or un-plastered surfaces of walls and applying three coats of white wash complete all as specified and directed.
M & L for preparation of newly plastered or un-plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed.
M & L for preparing newly plastered or previously untreated wall surfaces and applying two coats of cement base paint over one coat of primer complete all as specified and directed.
M & L for preparing old decorated wall surfaces and applying two coats of cement base paint complete all as specified and directed.
M & L for applying 2 mm thick wall care putty on wall surfaces complete all as specified and directed.
M & L for preparation of new plastered or previously untreated surfaces of walls and applying two coats of distemper oil emulsion over a coat of primer complete all as specified and directed.
M & L for preparation of old decorated surfaces of walls and applying two coats of distemper oil emulsion complete all as specified and directed.
Demolition of cement concrete (un-reinforced) any description and laid in any position complete all as specified and directed.
M & L for 25 mm thick cement concrete type B-1, 1:2:4 (using 20 mm graded stone aggregate) as in levelling course over roof slab, finished even and smooth without using extra cement complete all as specified and directed.
M & L for providing APP based polymeric membrane minimum weighing not less than 3 Kg per sqm and minimum 3 mm thick reinforced with polyster non woven fabric (weight not less than 150 Grams per sqm) laid by forced application over and including bituminous primer @ 0.30 Litre per sqm and hot blown bitumen @ 1.20 Kg per square metre after cleaning of roof surface complete all as specified and directed.
Demolition of cement concrete (un-reinforced) in ground floor and paving not exc. 15 cm thick (Below or above ground level) complete all as specified and directed.
M & L for 75 mm thick cement concrete 1:3:6 type C-2, using 40 mm graded stone aggregate as in plinth protection laid to slop of 1:12, finished surface even and fair without using extra cement with and including all necessary form work to divide the area in panels, finishing exposed edges fair or rounding or chamfering where directed and providing 75 mm wide and 3 mm thick glass dividing strip inserted in position at every one meter and change of direction complete all as specified and directed.
Taking down carefully aluminium / copper point wiring (light point, fan point, socket outlet point or power point) any type (batten, casing-N-caping, surface conduit or concealed conduit) complete with and including fittings and fixtures such as switches, ceiling rose, pendent, lamp holder, regulator, switch, socket outlet, shade conical etc. and making good disturbed surfaces of walls etc. as per existing finishes by plastering, repairs and distemper / white wash / colour wash etc. complete all as specified and directed.
Taking down carefully unserviceable Main switch/DB of any description, any type from any position complete all as specified and directed.
Taking down carefully old unserviceable sub main wiring any type and description and making good disturbed surfaces of wall, roof, floor etc. as per existing finishes complete all as specified and directed.
M & L for point wiring for one light point / fan point (Independent point), controlled by one, one way switch with 1.50 sqmm size, PVC insulated, unsheathed 1100 volts grade single core multi-stranded copper conductor cable (FRLS) drawn into and including non-metallic PVC conduit medium grade (not less than 20 mm dia) with and including its all necessary fittings and accessories fixed concealed with and including necessary chase cutting on brick / stone masonry walls and making good as per existing and sunk cast iron or 1.2 mm thick pressed steel terminal boxes for mounting fittings like switches, sockets, lamp holders, sketch fittings and covered with 3 mm thick plastic laminated sheet cover fixed with brass screws and cup washers including one continuous run of PVC insulated (green colour) 1.50 sqmm size stranded copper conductor cable (FRLS) as in earth wire and connecting all metal parts to common earth dolly complete all as specified and directed.
All as per item No. 24.00 hereinbefore but wiring for one 3 / 5 pin 5 Ampere socket outlet point on the independent board complete all as specified and directed.
All as per item No. 24.00 hereinbefore but wiring for one 3 / 5 pin 5 Ampere socket outlet point on the same board, controlled with other switches complete all as specified and directed.
All as per item No. 24.00 hereinbefore but wiring for one 3 / 6 pin 15 Ampere socket outlet point on independent board and wiring using with 2.50 sqmm size cables complete all as specified and directed.
S & F of modular type switch 6 Ampere, one way, 1 Modules complete all as specified and directed.
S & F of modular type socket outlet 6 Ampere, 2 and 3 Pin combination, 2 Modules complete all as specified and directed.
S & F of modular type switch 16 Ampere, one way, 1 Modules complete all as specified and directed.
S & F of modular type socket outlet 6 and 16 Ampere, 3 Pin for both rating (Total 6 Pins), 2 Modules complete all as specified and directed.
S & F of bell push button type single pole one-way 5 Ampere complete all as specified and directed.
S & F of single phase call bell ‘DING DONG’, AC 230 volts single pole complete all as specified and directed.
S & F of ceiling rose PVC/ polycarbonate isolated body 3 terminal, 230 volts AC ISI marked, complete all as specified and directed.
S & F of Lamp holders PVC /polycarbonate insulated body modular type with back plate suitable for batten fitting/angle fitting complete all as specified and directed.
S & F as in replacement LED light of 1 x 10 watt T-5 Lamp type with electronic ballast of suitable capacity, clear acrylic cover including mounting on wall complete all as specified and directed.
S & F as in replacement surface mounting LED light fitting aluminium extruded T-5 batten, 20 Watt, 4 feet long including making electric connection with 23/0.0076 size three core PVC flexible cable complete all as specified and directed.
S & F as in replacement indoor decorative LED city-3 light fitting polycarbonate body with with upper glove suitable for & including single 12 Watt LED lamp complete all as specified and directed.
S & F of LED Lamp12 Watt, 230 Volt AC integrated circuit complete all as specified and directed.
S & F of security light fitting, LED type, 20 Watt, 6000K, presure die cast housing with prismatic polycarbonate diffuser & individual LEDs as light source with integrated electronic driver complete with and including GI pipe mounting bracket made of 25/32 mm dia and 1.20 m long fixed to wall with and including nut bolts and GI clamps of size 50 x 6 mm as required including two coats of synthic enameled paint over a coat of primer and making connection with three core 23/.0076 rubber insulated copper cable from ceiling rose to connector ot street light complete all as specified and directed.
S & F of 1100 volts grade heavy duty 6.00 Sqmm size two single core PVC insulated (FRLS) copper multi-stranded conductor cable as in sub main wiring, drawn into & including PVC conduit medium grade not less than 20 mm dia including its all accessories & fittings, fixed concealed with and including chase cutting and making good the same as per existing specifications along with a continuous run of 4.00 Sqmm size stranded copper conductor PVC insulated (FRLS) (green colour) cable as earth wire complete all as specified and directed. NOTE: - TWO SINGLE CORE CABLES ALONG WITH EARTH WIRE AND PVC CONDUIT SHALL BE MEASURED AS ONE UNIT LENGTH.
S & F of 1100 volts grade heavy duty 4.00 Sqmm size two single core PVC insulated (FRLS) copper multi-stranded conductor cable as in sub main wiring, drawn into & including PVC conduit medium grade not less than 20 mm dia including its all accessories & fittings, fixed concealed with and including chase cutting and making good the same as per existing specifications along with a continuous run of 2.50 Sqmm size stranded copper conductor PVC insulated (FRLS) (green colour) cable as earth wire complete all as specified and directed. NOTE: - TWO SINGLE CORE CABLES ALONG WITH EARTH WIRE AND PVC CONDUIT SHALL BE MEASURED AS ONE UNIT LENGTH.
Taking down carefully ceiling fan and keeping the safe custody for reuse at site after completion of building repair work including painting of ceiling fans with one coat of synthetic enamel paint by spray painting process including filling cavities with filler, after cleaning all dust and the like complete all as specified and directed.
Taking down carefully electric meter and refixing the same after completion of building repair work including providing new laminated sheet of suitable size as per site requirment complete all as specified and directed.
Taking down carefully geyser of any description and keep insafe custody for reuse at site after completion of bldg repair work with and including painting to Geyser with synthetic enamel paint by spray painting process, written of existing MES No, servicing of geyser with minor repairs, fixing the same with necessary fixing arrangement as required at site and making electric connection complete all as specified and directed.
S & F of MCB single pole and neutral, 240 volts, 32 to 40 Ampere breaking capacity 10 KA, ‘B’ Series complete all as specified and directed.
S & F of MCB single pole, 240 volts, 6 to 32 Ampere breaking capacity 10 KA, ‘B’ Series complete all as specified and directed.
S & F of MCB triple pole and neutral, 415 volts, 40 Ampere breaking capacity 10 KA, ‘B’ Series complete all as specified and directed.
S & F of single pole AC modular box with a top and earth plug and socket including one single pole MCB of 20 Amp capacity suitable for connection of AC complete all as specified and directed.
S & F of flush mounting factory made SPN DB's Double door, 8 way, IP-42 Protection, detachable gland plates for MCB fitted with bus bar, earth bar and neutral links complete all as specified and directed.
S & F of flush mounting factory made TPN DB's Double door, 4 way, IP-42 Protection, detachable gland plates for MCB fitted with bus bar, earth bar and neutral link complete all as specified and directed.
Taking out old unserviceable earthing any type and M & L for earthing complete with galvanised steel earth plate electrode 600 mm X 600 mm X 6 mm thick buried directly in ground (earth pit not less than 2.25 m below ground level) with top edge of earth plate not less than 1.50 m below normal ground level, connected to galvanised earth lead 4 mm dia all as shown on electrical plate No. 3 of MES schedule 2009, Part–I (Specifications) and connected to main switch board / main DB’s / earthing test point including all necessary excavation and earth work in any type of soil, adequate quantity of charcoal dust & common salt all around the earth plate minimum 150 mm in all directions with & including watering pipe 20 mm dia GI medium grade, GI funnel made out of 0.63 mm thick GI sheet, wire gauge, 50 mm thick RCC cover in PCC 1:2:4, type B-1, duly reinforced with 6 mm dia mild steel TMT bars @ 150 mm both ways center to center with suitable lifting handle to cover, earth pit of PCC 1:2:4 type B-1, GI protection pipe light grade 15 mm bore including testing on completion of job complete all as specified and directed.
Excavation in trenches not exc. 1.50 m wide and not exc. 1.50 m in depth for laying cables and getting out in hard / dense soil including trimming sides and forming bottom surface to the required level / slope etc complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm in each layer as in soil complete all as specified and directed.
Removing excavated material (soil) to a distance not exc. 50 m and depositing where directed at a level not exc. 1.5 m above the starting point complete all as specified and directed.
M&L for sand cushioning with layer of sand 8 cm thick before laying of cable and 15 cm after laying of cable in trenches, punning complete all as specified and directed. Note:- Punning thickness of 18 cm will be considered for payment.
M & L for laying brick as in protection covers over cables using sub class 'B' old size bricks laid flat, length wise perpendicular to the axis of cable complete all as specified and directed.
Supply and laying XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with stranded aluminium conductor 1100 volt grade, laid in trenches/ducts, fixed on wall/inside panel, drawn through pipe of cross sectional area 25 Sqmm 4 core with and including taking out old unserviceable one complete all as specified and directed.
S & F in replacement 40 mm bore GI pipe light grade for cable protection, fixed to pole/ alongwall/ floor/ under road/ across the drain or nallaha etc complete all as specified and directed.
NOTE:-Tenderers may note that amount of credit Rs 17,025.00 will be deducted from the total amount arrived at the time of Acceptance of tender.
M/S Shree Sai Builders
hardeep singh enterprises
JAI SRI RAM ASSOCIATE
Shri Siddhi Vinayak Constructions
RIYASAT ALI KHAN
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .