Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.7 LAccepted-AOC | L1 | Accepted-AOC accept first lowest | |
| 2 | L2₹45.2 L+₹52,041.55 (1.16%)Rejected-Finance BHAGAT BUILDING SADAR BAZAR RANIKHET DIST ALMORA | RANIKHET | ALMORA | UTTARAKHAND | L2 | Rejected-Finance SECOUND LOWEST | |
| 3 | L3₹45.8 L+₹1.1 L (2.46%)Rejected-Finance LOCATION UTTARAKHAND UT | L3 | Rejected-Finance THIRD LOWEST |
Tender Value
₹52.7 L
EMD Value
₹1.1 L
Closing Date
17 Feb 2021, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EXECUTIVE ENGINEER RWD BHIKIYASAIN
E.E RWD BHIKIYASEN
Construction of Art and Craft Room liabrary in GIC JAMOLI VINAYAK
2021_RES_29010_2
1394/RWD/2020-21dt 16.01.2021
Open Tender
Civil Works - Buildings
Item Rate
365 days
VINYAK
Please refer Tender documents.
2 documents required · 2 mandatory
₹4,720
Yes
Director, Horticulture and Food Processing, Uttara
₹1.1 L
Yes
8 May 2023
20 Jan 2021
18 Feb 2021
20 Jan 2021
17 Feb 2021
20 Jan 2021
120 days
Amount
Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual mea in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including gettin out the excavated soil and disposal of surplus excavated soil as directed, within a lea of 50 m (a) All kinds of soil
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m
Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor
Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - -All work upto plinth level
1:2:4 (1 cement : 4 fine sand : 8 graded stone aggregate 40 mm nominal size)
1:4:8 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size).
Extra for providing and mixing water proofing material in cement concrete work @ 1 kg per 50 kg of cement.
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement :3 coarse sand : 6graded stone aggregate 20mm nominal size) over 75mm bed by dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth
Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement - All work upto plinth level 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. upto floor five level excluding cost of centring shuttering, finishing and reinforcement 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) G.F.
Centring and shuttering including strutting ,ropping etc. and removal of form for foundations, footings, bases of columns, etc. for mass concrete.
Suspended floors, roofs, landings, balconies and access platform
Lintels, beams, plinth beams, girders, bressumers and cantilevers
Columns, Pillars, Piers, Abutments, Posts and Struts.
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete Reinforcement for R.C.C. Work Using Thermo-Mechanically Treated bars of grade Fe-500D or more.
Add or deduct for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections.
Brick work with F.P.S. bricks of class designation 75 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand)
Brick work with F.P.S. bricks of class designation 75 in superstructure above plinth level upto floor V level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand)
Half brick masonry with F.P.S. bricks of class designation 75 in superstructure abov plinth level upto floor V level in Cement mortar 1:4 (1 cement :4 coarse sand)
Providing and fixing 35 mm th. ISI marked flush door shutters including stailness butt hinges with necessary screw conforming to IS: 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters (a) 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws.
Providing and fixing M.S. grills of required pattern in frames (a) MS grills fixed to steel windows by welding.
Providing and fixing fly proof galvanised M.S. wire gauge to windows and clerestory (a) With 12 mm mild steel U beading.
Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic) 300x16 mm - Door shutter
Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating)
250x10 mm - Door shutter
150x10 mm - Door shutter
Providing and fixing aluminium handles ISI marked anodised (anodic coating not) (a) 125 mm
Providing and fixing aluminium hanging floor door stopper ISI marked anodised (a) Twin rubber stopper
Providing and fixing pressed steel door frames confirming to IS: 4351 manufactured from commercial mild steel sheet of 1.25 mm thickness including hinges jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25mm, or base ties of 1.25mm pressed mild steel welded or rigidly fixed together by mechanical means, adjustable lugs with split end tail to each jamb including steel butt hinges 2.5mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge (a) Profile C
Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with L-Type section made of 1.60mm thick M.S. Sheet, joints mitred and welded and grinded finish profiles required size with 15x3mm lugs 10cm long embedded in cement concrete blocks 15x10x10cm of 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) or with wooden plugs and screws or rawl plugs and screws or with fixing clips or with bolts and nuts as required including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primers.
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thic
Kota stone slabs 25 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacture ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes 110 mm -dia
12 mm cement plaster of mix 1:6 (1 cement : 6 fine sand)
15 mm cement plaster on rough side of single or half brick wall of mix. 1:6 cement and fine sand mortar.
6 mm cement plaster of mix 1:3 (1 cement: 3 fine sand)
Providing and laying pressed clay tiles (as per approved pattern 20 mm nominal thickness and of approved size) on roofs jointed with cement mortar 1:4 (1 cement : 4 coarse sand) mixed with 2% integral water proofing compound laid over a bed of 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand) and finished neat complete.
Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete.
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade New work (two or more coats) over and including priming coat with cement primer
Finishing walls with textured exterior paint of required shade (a) New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including base coat of water proofing cement paint applied @ 2.20kg/10 sqm.
Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/ 10 sqm of approved brand or manufacture
Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand or manufacture
Renewing glass panes, with putty and nails wherever necessary (a) Float glass panes of thickness 5.5 mm
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stoneaggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.40 mm thick with 20 mm nominal size stone aggregate
Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compoundconsisting of applying: (a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253kg/sqm. (b) laying second layer of Fibre glass cloth when the first layer isstill green. Overlaps of joints of fibre cloth should not be less than 10 cm. (c) third layer of 1.5 mm thickness consisting of slurry of cement@ 1.289 kg/sqm mixed with water proofing cement compound@ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This willbe allowed to air cure for 4 hours followed by water curing for 48hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. d) fourth and final layer of brick tiling with cement mortar (which will be paid for separately.For the purpose of measurement the entire treated surface will be measured.
Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement.12 mm cement plaster
Extra for providing and mixing water proofing material in cement .Per bag plaster work in proportion recommended by the manufacturers
GIRISH BHAGAT
AJAY KUMAR CHAUHAN
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .