| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹49.6 LAccepted-AOC H 10 KARNI NAGAR NEW NAGAUR ROAD NEAR MANDORE POLICE STATION 8TH MILL MANDORE JODHPUR 342304 | JODHPUR | JODHPUR | RAJASTHAN | 342304 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹53.2 L+₹2.4 L (4.62%)Rejected-Finance INDORA TEHSIL INDORA DISTT KANGRA HIMACHAL PRADESH | KANGRA | HIMACHAL PRADESH | 175013 | L2 | Rejected-Finance Rejected due to L2 | |
| 3 | L3₹53.4 L+₹2.5 L (4.95%)Rejected-Finance | L3 | Rejected-Finance Accepted due L3 | |
| 4 | Rejected-Technical | - | Rejected-Technical Rejected due to eligible category not found |
| Sl No | Description | Qty | Unit | Shri Electrical Enterprises L1 | M/s R K Enterprises L3 | Chamunda construction company L2 |
|---|---|---|---|---|---|---|
| 1.00 | M & L for routine check up and servicing of soft starter of model EMX4i of capacity 24 to 229 Amp ,duly recommending the maintanance/replacement of the UNSV parts required which are not working properly. All parts shall be measured and paid seperately here-in-after. Maintanance/servicing shall be carried out by OEM maint engineer only & proper setting of O/L, running, starting / stopping, ramping time with proper measurememnt of each & every set of starter. Mainly HMI module, PCB, CT, Fan, Thyristor and by pass. complete all as directed by Engr-in-Charge at site. | 20 | Each Job | 950 ₹19,000 Lowest | 2,500 ₹50,000 | 1,750 ₹35,000 |
| 2.00 | Supply and fix in replacement Kit User Interface CI M/R 0020-0129 make L & T model EMX4i Of following capacity
(a) 24 Amp to 135Amp , Cat No 995-18604-00 | 1 | Each | 22,000 ₹22,000 Lowest | 37,500 ₹37,500 | 35,000 ₹35,000 |
| 2.01 | (b) 184 Amp to 229 Amp , Kit user interface CI M/R 0143-0580 Cat No 995-18605-00 | 1 | Each | 22,000 ₹22,000 Lowest | 33,000 ₹33,000 | 33,000 ₹33,000 |
| 3.00 | Supply and fix in replacement of Kit Motor Ctrl V5 M/R 0020-0129 make L & T model EMX4i of capacity 24 Amp to 135 Amp, Cat No 995-18607-00 | 1 | Each | 19,000 ₹19,000 | 2,500 ₹2,500 Lowest | 4,500 ₹4,500 |
| 4.00 | Supply and fix in replacement of Kit Motor Ctrl V5 M/R 0143--0580 make L & T model EMX4i of capacity 184 Amp to 229 Amp ,Cat No 995-18608-00 | 1 | Each | 19,000 ₹19,000 Lowest | 27,900 ₹27,900 | 25,000 ₹25,000 |
| 5.00 | Supply and fix in replacement of Kit SCR M/R 0060-0069 make L & T model EMX4i of capacity 42Amp to 135 Amp, Cat No 995-18614-00 | 1 | Each | 8,000 ₹8,000 | 7,000 ₹7,000 | 5,000 ₹5,000 Lowest |
| 6.00 | Supply and fix in replacement of Kit SCR M/R 0085-0107 make L & T model EMX4i of capacity 105Amp to 115 Amp, Cat No 995-18615-00 | 1 | Each | 10,000 ₹10,000 Lowest | 17,500 ₹17,500 | 19,000 ₹19,000 |
| 7.00 | Supply and fix in replacement of Kit SCR M/R 0143-0193 make L & T model EMX4i of capacity 184 Amp to 229 Amp, Cat No 995-18617-00 | 1 | Each | 19,000 ₹19,000 Lowest | 33,000 ₹33,000 | 35,000 ₹35,000 |
| 8.00 | Supply and fix in replacement of Kit Fan M/R 0041-0129 make L & T model EMX4i of capacity 24 Amp to 135 Amp, Cat No 995-18622-00 | 1 | Each | 4,500 ₹4,500 Lowest | 7,315 ₹7,315 | 4,500 ₹4,500 Lowest |
| 9.00 | Supply and fix in replacement of Kit Fan M/R 0043-0580 make L & T model EMX4i of capacity of capacity 184Amp to 229 Amp, Cat No 995-18623-00 | 1 | Each | 5,500 ₹5,500 | 7,315 ₹7,315 | 4,700 ₹4,700 Lowest |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
21 Oct 2025, 6:00 pmClosed
OFFG AGE (C)
Military Engineer Services, Garrison Engineer (Army) No 2 Jodhpur, Multan Lines, Army Area Jodhpur -342010
REPAIR/MAINTENANCE OF PUMP, PANELS AND ALLIED WORKS AND AUTOMATION SYSTEM AT ARMY AREA JODHPUR
2025_MES_732081_1
8800/25-26/53/04/E8
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
GE (ARMY) NO 2 JODHPUR
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE (ARMY) NO 2
₹98,000
Yes
22 Jan 2026
30 Sept 2025
23 Oct 2025
30 Sept 2025
21 Oct 2025
14 Oct 2025
30 Sept 2025 - 7 Oct 2025
Amount
M & L for routine check up and servicing of soft starter of model EMX4i of capacity 24 to 229 Amp ,duly recommending the maintanance/replacement of the UNSV parts required which are not working properly. All parts shall be measured and paid seperately here-in-after. Maintanance/servicing shall be carried out by OEM maint engineer only & proper setting of O/L, running, starting / stopping, ramping time with proper measurememnt of each & every set of starter. Mainly HMI module, PCB, CT, Fan, Thyristor and by pass. complete all as directed by Engr-in-Charge at site.
Supply and fix in replacement Kit User Interface CI M/R 0020-0129 make L & T model EMX4i Of following capacity (a) 24 Amp to 135Amp , Cat No 995-18604-00
(b) 184 Amp to 229 Amp , Kit user interface CI M/R 0143-0580 Cat No 995-18605-00
Supply and fix in replacement of Kit Motor Ctrl V5 M/R 0020-0129 make L & T model EMX4i of capacity 24 Amp to 135 Amp, Cat No 995-18607-00
Supply and fix in replacement of Kit Motor Ctrl V5 M/R 0143--0580 make L & T model EMX4i of capacity 184 Amp to 229 Amp ,Cat No 995-18608-00
Supply and fix in replacement of Kit SCR M/R 0060-0069 make L & T model EMX4i of capacity 42Amp to 135 Amp, Cat No 995-18614-00
Supply and fix in replacement of Kit SCR M/R 0085-0107 make L & T model EMX4i of capacity 105Amp to 115 Amp, Cat No 995-18615-00
Supply and fix in replacement of Kit SCR M/R 0143-0193 make L & T model EMX4i of capacity 184 Amp to 229 Amp, Cat No 995-18617-00
Supply and fix in replacement of Kit Fan M/R 0041-0129 make L & T model EMX4i of capacity 24 Amp to 135 Amp, Cat No 995-18622-00
Supply and fix in replacement of Kit Fan M/R 0043-0580 make L & T model EMX4i of capacity of capacity 184Amp to 229 Amp, Cat No 995-18623-00
Supply and fix in replacement of Kit CT M/R 0020-0129 make L & T model EMX4i of capacity 24 Amp to 135 Amp, Cat No 995-18624-00
Supply and fix in replacement of Kit CT M/R 0143-0243 make L & T model EMX4i of capacity 184 Amp to 229 Amp, Cat No 995-18625-00
Supply and fix in replacement of Bypass Contactor Kit, M/R 0020-0069 make L & T model EMX4i of capacity 24Amp to 69Amp, Cat No 995-18628-00
Supply and fix in replacement of Bypass Contactor Kit, M/R 0085-0129 make L & T model EMX4i of capacity 105Amp to 135Amp, Cat No 995-18629-00
Supply and fix in replacement of Bypass Contactor Kit, M/R 0143-0243 make L & T model EMX4i of capacity 184 Amp to 229 Amp, Cat No 995-18630-00
Supply and fix in replacement of Kit snubber M/R 0020-0069 make L & T model EMX4i of capacity 24Amp to 69Amp, Cat No 995-18633-00
Supply and fix in replacement of Kit snubber M/R 0085-0129 make L & T model EMX4i of capacity 105Amp to 135Amp, Cat No 995-18634-00
Supply and fix in replacement of Kit snubber M/R 0143-0243 make L & T model EMX4i of capacity 184Amp to 229 Amp, Cat No 995-18635-00
M & L for routine check up and servicing of soft starter of model CSXi of capacity 7.5KW to 110KW,duly recommending the maintanance/replacement of the UNSV parts required which are not working properly. All parts shall be measured and paid seperately here-in-after. Maintanance/servicing shall be carried out by OEM maint engineer only & proper setting of O/L, running, starting / stopping, ramping time with proper measurememnt of each & every set of starter. Mainly PCB, CT, Fan, Thyristor and by pass. Complete all as directed by Engr-in-Charge at site.
Supply and fix in replacement CSXi, Kit,Mn Ctrl PCB,1,V4,C1,007-110 make L & T model CSXi of capacity 7.5 to 110 KW , Cat No 995-02537-00
Supply and fix in replacement CSXi, Kit,,Interface PCB,022 make L & T model CSXi of capacity 7.5 KW to 110 KW , Cat No 995-02547-00 to 995-03877-00
Supply and fix in replacement CSXi, Kit,,By pass Relay, 007-030 make L & T model CSXi of capacity 7.5 KW to 30KW , Cat No 995-02568-00
Supply and fix in replacement CSXi, Kit,Current transformer 07-035 make L & T model CSXi of capacity 7 KW to 35KW , Cat No 995-02571-00
Supply and fix in replacement CSXi, Kit,SCR 007 make L & T model CSXi of capacity 7 to 15 KW , Cat No 995-02557-00
Supply and fix in replacement CSXi, Kit,SCR 015 make L & T model CSXi of capacity 15 to 35 KW , Cat No 995-02558-00
Supply and fix power contactor 3 pole of capacity 300 Amp rating 415 Volt / AC-3 duty recommended to suit existing type, make & model to suit existing mounting space.
Supply and fix power contactor 3 pole of capacity 250 to 265 Amp rating 415 Volt / AC-3 duty recommended to suit existing type, make & model to suit existing mounting space.
Supply and fix power contactor 3 pole of capacity 185 to 200 Amp rating 415 Volt / AC-3 duty recommended to suit existing type, make & model to suit existing mounting space.
Supply and fix power contactor 3 pole of capacity 140 to 150 Amp rating 415 Volt / AC-3 duty recommended to suit existing type, make & model to suit existing mounting space.
Supply and fix power contactor 3 pole of capacity 225 Amp rating 415 Volt / AC-3 duty recommended to suit existing type, make & model to suit existing mounting space.
Supply and fix power contactor 3 pole of capacity 95 Amp rating 415 Volt / AC-3 duty recommended to suit existing type, make & model to suit existing mounting space.
Supply and fix power contactor 3 pole of capacity 110 Amp rating 415 Volt / AC-3 duty recommended to suit existing type, make & model to suit existing mounting space.
Supply and fix power contactor 3 pole of capacity 63 Amp rating 415 Volt / AC-3 duty recommended to suit existing type, make & model to suit existing mounting space.
Supply and fix power contactor 3 pole of capacity 40 to 50 Amp rating 415 Volt / AC-3 duty recommended to suit existing type, make & model to suit existing mounting space.
Supply and fix in repair start / stop push botton as per existing for motor control panel
S& F in replacement of Pneumatic Timers Time Delay Relay-Electro Pneumatic type along with suitable Nos of NO+NC as per control panel of starter as existing for time delay 0 to 60 second setting on steps suitabile for 100 to 150 HP motor starting panel. cat no KRTPCN11M- 1
S& F in replacement overload relay of Range 13 to 30 Amp rating to suit safe operation of induction/ submersible motor of capacity up to 15HP motor.Make BCH or equivalent
All as per item No. 36 here-in-above but CT operated relay range 188 to 300A for 150/100HP motor starter of auto transformer type for ATS panel make BCH HSN Code 8536 cat code CT6MC305ANA3C or equivalent
M&L for rewinding of autotransformer unit of A/T starter complete with winding wire of super enamelled Impregnated copper wire of existing size and type complete with empire tape, glass tape, impregnated paper, bamboo Chips etc & transporting from panel place to wksp and back, reconnection after completion and testing of load, for 150 HP PUMP ,all as directed by Engr-in-Charge.
M&L for electrical disconnection of submersible pump for taking out existing column pipe of size 32 to 80 mm along with pump set 1 to 10 HP from borewell with essential tools like tripod, chain, pully, etc and manpower & replacement of unserviceable parts of column pipe, motor, pump etc as per requirement, spare parts and column pipe shall be measured and paid seperately, lowering of submersible pumping set with column pipe complete and testing after completion of work all as directed by Einr-in-Charge. Note: i) Repair of pump and motor will be paid and measured seperately under respective items. ii) Minor items such as rubber packing, gaskets, grease etc deemed to be included.
M&L for repair /servicing of submersible pump set, strip opening multi stage submersible pumpset of capacity 1 to 1.5HP. Replacement of unsv parts & reassembling the same, testing after completion of of job & spare parts shall be measured & paid seperately here-in-after. Complete all as directed by Engr-in-Charge.
(a) Impeller
(b) Sleeve coupling
( c ) allen key screw
(d) thrust bearing set
(e) Bush
Material and labour for rewinding of submersible electric motors transporting from site to repair shop and repair shop to site, dismantling, stripping out and removing old burnt winding wire, cleaning of slots etc. Rewinding complete with super enamelled copper winding wire of appropriate gauge including all necessary insulation material class-I, varnishing and heating as per requirment. Re-installing in position, assembling at site, realigning with pump set, coupling with pump, making electric connection all as direcred and testing for smooth functioning for following capacity (a) 1/1.5 HP Single phase.
M&L for repair of submersible pump set, strip opening multi stage submersible pumpset of capacity 5 to 10HP. Replacement of unsv parts & reassembling the same, testing after completion of job & spare parts shall be measured & paid seperately here-in-after. Complete all as directed by Engr-in-Charge.
(a) Thrust bearing
(b) Bowl set
(c) Impellor driving rod (shaft) complete
(d) Impellor
(e ) Bush
(f) MS Coupling
Material and labour for rewinding of submersible electric motors transporting from site to repair shop and repair shop to site, dismantling, stripping out and removing old burnt winding wire, cleaning of slots etc. Rewinding complete with PVC submersible copper winding wire of appropriate gauge including all necessary insulation material as per requirment. Re-installing in position, assembling at site, realigning with pump set, coupling with pump, making electric connection all as directed and testing for smooth functioning for capacity of 5 HP three phase.
Material and labour for rewinding of submersible electric motors transporting from site to repair shop and repair shop to site, dismantling, stripping out and removing old burnt winding wire, cleaning of slots etc. Rewinding complete with PVC submersible copper winding wire of appropriate gauge including all necessary insulation material as per requirment. Re-installing in position, assembling at site, realigning with pump set, coupling with pump, making electric connection all as directed and testing for smooth functioning for capacity of 7.5 HP three phase.
Material and labour for rewinding of submersible electric motors transporting from site to repair shop and repair shop to site, dismantling, stripping out and removing old burnt winding wire, cleaning of slots etc. Rewinding complete with PVC submersible copper winding wire of appropriate gauge including all necessary insulation material as per requirment. Re-installing in position, assembling at site, realigning with pump set, coupling with pump, making electric connection all as directed and testing for smooth functioning for capacity of 10 HP three phase.
Supply and fix high pressure cooling pipe with end connections suitable for 50/60/75/100/150HP kirloskar pump pump.
Supply and fix in repair rubber coupling Star type suitable for 150 HP size Pump complete all as specified and directed.
All as per Item Ser no 47 above but for 75/100 HP
All as per Item Ser no 47 above but for 50/60 HP
All as per Item Ser no 47 above but for 10/12.5/15HP
Supply and fix in repair rubber coupling tyre type suitable for 150 HP size of centrifugal Pumping set complete all as specified and directed.
All as per Item Ser no 48 above but for 75/100 HP
All as per Item Ser no 48 above but for 20/25 HP
M&L for routine / Preventive maint of pump / motor set complete of size 150 HP. SKF high performance, high temperature superior quality pump & motor bearing grease of model - SKF LG HP 2/18 or equivalant quality of make castrol / Valvoline etc, nut / bolts, complete with repair / replacment of unsv acessories like cooling pipe/ drain pipe, washer, packing etc complet. All items like hose set nipple, washer, ball valve Gland having high purity with lubricant, alinment of pump and motor etc shall be deemed to be included in repair. Record shall be maintained in register duly singed by Engr-in-Charge.
M&L for routine / Preventive maint of pump / motor set complete of size 100 HP. SKF high performance, high temperature superior quality pump & motor bearing grease of model - SKF LG HP 2/18 or equivalant quality of make castrol / Valvoline etc, nut / bolts, complete with repair / replacment of unsv acessories like cooling pipe/ drain pipe, washer, packing etc complet. All items like hose set nipple, washer, ball valve Gland having high purity with lubricant, alinment of pump and motor etc shall be deemed to be included in repair. Record shall be maintained in register duly singed by Engr-in-Charge.
M&L for routine/Preventive maint of pump / motor set complete of size 75 to 50 HP. SKF high performance, high temperature superior quality pump & motor bearing grease of model - SKF LG HP 2/18 or equivalant quality of make castrol / Valvoline etc, nut / bolts, complete with repair / replacment of unsv acessories like cooling pipe/ drain pipe, washer, etc complet. All items like hose set nipple, washer, ball valve, Gland having high purity with lubricant alinment of pump and motor etc shall be deemed to be included in repair. Record shall be maintained in register duly singed by Engr-in-Charge
M&L for routine/Preventive maint of pump / motor set complete of size 12.5 to 20 HP. SKF high performance, high temperature superior quality pump & motor bearing grease of model - SKF LG HP 2/18 or equivalant quality of make castrol / Valvoline etc, nut / bolts, complete with repair / replacment of unsv acessories like cooling pipe/ drain pipe, washer, etc complet. All items like hose set nipple, washer, ball valve, Gland having high purity with lubricant alinment of pump and motor etc shall be deemed to be included in repair. Record shall be maintained in register duly singed by Engr-in-Charge
M&L for routine/Preventive maint of pump / motor set complete of size 10 to 03 HP. SKF high performance, high temperature superior quality pump & motor bearing grease of model - SKF LG HP 2/18 or equivalant quality of make castrol / Valvoline etc, nut / bolts, complete with repair / replacment of unsv acessories like cooling pipe/ drain pipe, washer, etc complet. All items like hose set nipple, washer, ball valve, Gland having high purity with lubricant alinment of pump and motor etc shall be deemed to be included in repair. Record shall be maintained in register duly singed by Engr-in-Charge
Material and labour for Gland fiiling having high purity with lubricant of suitable size & suitable for high speed, high temprature and high pressure application.
M&L for strip opening of submersible mono block pump motor of capacity 03 to 05 HP, rewinding with PVC copper wire winding wire of existing size with insulated paper / bamboo clips empire tape / glass tape etc, tesing after completion of job.
M&L for strip opening of submersible mono block pump motor of capacity 10 to 12 HP, rewinding with PVC copper wire winding wire of existing size with insulated paper / bamboo clips empire tape / glass tape etc, tesing after completion of job.
S&F in replacemnt of Bush of mono block submersible pump 03 to 05 HP
S&F in replacemnt of Bush of mono block submersible pump 10 to 12 HP
M&L for repair of centrifugal pump of Capacity 100 to 150 HP strip opening of casing of pumping set. for checking of defective parts Repair / replacement of unsv parts & reassembling the same & testing after completion of work. cost of gasket and minor parts like nut bolt and washer etc is deemed to be included in quoted rates, Spare parts shall be measured & paid seperately here-in-after, as directed by Engr-in-Charge.
Supply and fixing in replacement of impellor C.I. with all acessories for pumping set capacity of 100 to 150 HP pumping set.
Supply and fixing in replacement of impeller Wearing Ring C .I. as per existing of capacity of 100 to 150 HP pumping set.
Supply and fixing in replacement of impeller Casing Ring C .I. as per existing of capacity of 100 to 150 HP pumping set.
Supply and fixing in replacement of shaft Sleeve/bush C.I. as per existing of capacity of 100 to 150 HP pumping set.
Supply and Fixing in Replacement of NDE/DE pump bearing as per existing size, type, of capacity 100 to 150 HP.
Supply and fixing in replacement of Gland plate CI capacity of 100 to 150 HP pumping set.
M&L for straightening of Pump shaft including filling/welding cutting of existing size and lathe work for pump as per existing size, type, make & model.capacity of 100 to 150 HP pumping set.
M&L for repair of centrifugal pump of Capicity 50 to 75 HP strip opening of casing of pumping set. for checking of defective parts Repair / replacement of unsv parts & reassembling the same & testing after completion of work. cost of gasket and minor parts like nut bolt and washer etc is deemed to be included in quoted rates, Spare parts shall be measured & paid seperately here-in-after, as directed by Engr-in-Charge.
Supply and fixing in replacement of impellor C.I. with all acessories for centrifugal pumping set capacity of 50 to 75 HP pumping set.
Supply and fixing in replacement of impeller Wearing Ring C .I. as per existing of capacity of 50 to 75 HP centrifugal pumping set.
Supply and fixing in replacement of impeller Casing Ring C .I. as per existing of capacity of 50 to 75 HP centrifugal pumping set.
Supply and fixing in replacement of shaft Sleeve/Bush C.I. as per existing of capacity of 50 to 75 HP centrifugal pumping set.
Supply and Fixing in Replacement of NDE/DE pump bearing as per existing size, type, of capacity 50 to 75 HP,centrifugal pump set.
Supply and fixing in replacement of Gland plate CI capacity of 50 to 75 HP centrifugal pumping set.
M&L for straightening of Pump shaft including filling,welding,cutting of existing size and lathe work for pump as per existing size, type, make & model.capacity of 50 to 75 HP pumping set.
M&L for repair of centrifugal pump of Capicity 10 to 15 HP strip opening of casing of pumping set. for checking of defective parts Repair / replacement of unsv parts & reassembling the same & testing after completion of work. cost of gasket and minor parts like nut bolt and washer etc is deemed to be included in quoted rates, Spare parts shall be measured & paid seperately here-in-after, as directed by Engr-in-Charge.
Supply and fixing in replacement of impellor C.I. with all acessories for centrifugal pumping set capacity of 10 to 15 HP pumping set.
Supply and fixing in replacement of impeller Wearing Ring C .I. as per existing of capacity of 10 to 15 HP pumping set.
Supply and fixing in replacement of shaft Sleeve/Bush C.I. as per existing of capacity of 10 to 15 HP pumping set.
Supply and Fixing in Replacement of NDE/DE pump bearing as per existing size, type, of capicity 10 to 15 HP.
Supply and fixing in replacement of Gland plate CI capacity of 10 to 15 HP pumping set.
Replacement of mechnical seal for capacity 10 to 15 HP
M&L for straightening of Pump shaft including filling,welding,cutting of existing size and leath work for pump as per existing size, type, make & model.capacity of 10 to 15 HP pumping set.
M&L for repair of centrifugal pump of Capicity 5 to 7.5 HP strip opening of casing of pumping set. for checking of defective parts Repair / replacement of unsv parts & reassembling the same & testing after completion of work. cost of gasket and minor parts like nut bolt and washer etc is deemed to be included in quoted rates, Spare parts shall be measured & paid seperately here-in-after, as directed by Engr-in-Charge.
M&L for Replacement of CI impellor with all acessories for pumping set upto the capacity of 5 to 7.5 HP pumping set.
M&L for Replacement of NDE/DEbearing as per existing size, type, make & model.of capacity 5 to 7.5 HP HP
Supply and fixing in replacement of Gland plate CI capacity of 5 to 7.5 HP pumping set.
M&L for Replacement of mechanical seal for capacity 5 to 7.5 HP
M&L for straightening of Pump shaft including filling,welding,cutting of existing size and lathe work for pump as per existing size, type, make & model.capacity of 5 to 7.5 HP pumping set.
M&L for repair of centrifugal pump of Capicity 1.0 to 3.0 HP strip opening of casing of pumping set. for checking of defective parts Repair / replacement of unsv parts & reassembling the same & testing after completion of work. cost of gasket and minor parts like nut bolt and washer etc is deemed to be included in quoted rates, Spare parts shall be measured & paid seperately here-in-after, as directed by Engr-in-Charge.
Replacement of impellor with all acessories for pumping set upto the capacity of 1.0 to 3.0 HP pumping set.
Replacement of NDE/DE bearing as per existing size, type, make & model.of capacity 1.0 to 3.0
Replacement of mechnical seal for capacity 1.0 to 3.0 HP
M&L for straightening of Pump shaft including filling,welding,cutting of existing size and leath work for pump as per existing size, type, make & model.capacity of 1.0 to 3.0 HP pumping set.
M&L for strip opening of electric motor after electrically disconnecting 100 to 150 HP pump for rewinding / replacement of unsv parts & reassembling the same & testing on load at existing place in presence of Engr-in-Charge. transporting from wk place to wksp & wksp to wk place shall be deemed to be included, all other spare parts / rewinding wk, material shall be measured and paid seperately here-in-after. All as directed by Engr-in-Charge.
Rewinding of motor of capacity 150 HP with superenamelled pre-insulationed copper winding wire of existing size of copper wire with insulated paper / bamboo chips, empire tape / glass tape etc & tesing after completion of job.
Rewinding of motor of capacity 100 HP with superenamelled pre-insulationed copper winding wire of existing size of copper wire with insulated paper / bamboo chips, empire tape / glass tape etc & tesing after completion of job.
Replacement of NDE/DE bearing of Motor as per existing size, type, make & model. Of Capicity 100HP to 150 HP
Replacement of cooling fan of motor as per existing size, type, make & model. Of Capicity 100HP to 150 HP
M&L for strip opening of electric motor after electrically disconnecting 50 to 75 HP pump for rewinding / replacement of unsv parts & reassembling the same & testing on load at existing place in presence of Engr-in-Charge. transporting from wk place to wksp & wksp to wk place shall be deemed to be included, all other spare parts / rewinding wk, material shall be measured and paid seperately here-in-after. All as directed by Engr-in-Charge.
Rewinding of motor of capacity 75 HP with superenamelled pre-insulationed copper winding wire of existing size of copper wire with insulated paper / bamboo chips, empire tape / glass tape etc & tesing after completion of job.
Rewinding of motor of capacity 50 HP with superenamelled pre-insulationed copper winding wire of existing size of copper wire with insulated paper / bamboo chips, empire tape / glass tape etc & tesing after completion of job.
Replacement of NDE/DE bearing of motor as per existing size, type, make & model. Of Capicity 75HP to 50 HP
Replacement of motor cooling fan as per existing size, type, make & model. Of Capicity 75HP to 50 HP
M&L for strip opening of electric motor after electrically disconnecting 10 to 20 HP pump for rewinding / replacement of unsv parts & reassembling the same & testing on load at existing place in presence of Engr-in-Charge. transporting from wk place to wksp & wksp to wk place shall be deemed to be included, all other spare parts / rewinding wk, material shall be measured and paid seperately here-in-after. All as directed by Engr-in-Charge.
Rewinding of motor of capacity 20HP with superenamelled pre-insulationed copper winding wire of existing size of copper wire with insulated paper / bamboo chips, empire tape / glass tape etc & tesing after completion of job.
Rewinding of motor of capacity 15 HP with superenamelled pre-insulationed copper winding wire of existing size of copper wire with insulated paper / bamboo chips, empire tape / glass tape etc & tesing after completion of job.
Rewinding of motor of capacity 12.5HP with superenamelled pre-insulationed copper winding wire of existing size of copper wire with insulated paper / bamboo chips, empire tape / glass tape etc & tesing after completion of job.
Rewinding of motor of capacity 10HP with superenamelled pre-insulationed copper winding wire of existing size of copper wire with insulated paper / bamboo chips, empire tape / glass tape etc & tesing after completion of job.
Replacement of NDE/DE bearing of motor as per existing size, type, make & model. Of Capicity 10HP to 15 HP
Replacement of NDE/DE bearing of motor as per existing size, type, make & model. Of Capicity 20 HP
Replacement of cooling fan as per existing size, type, make & model. Of Capicity 10HP to 15 HP
Replacement of cooling fan as per existing size, type, make & model. Of Capacity 20 HP
M&L for strip opening of electric motor after electrically disconnecting 5 to 7.5 HP pump for rewinding / replacement of unsv parts & reassembling the same & testing on load at existing place in presence of Engr-in-Charge. transporting from wk place to wksp & wksp to wk place shall be deemed to be included, all other spare parts / rewinding wk, material shall be measured and paid seperately here-in-after. All as directed by Engr-in-Charge.
Rewinding of motor of capacity 7.5 HP with superenamelled pre-insulationed copper winding wire of existing size of copper wire with insulated paper / bamboo chips, empire tape / glass tape etc & tesing after completion of job.
Rewinding of motor of capacity 05 HP with superenamelled pre-insulationed copper winding wire of existing size of copper wire with insulated paper / bamboo chips, empire tape / glass tape etc & tesing after completion of job.
Replacement of NDE/DE bearing of motor as per existing size, type, make & model. Of Capicity 7.5HP to 05 HP
Replacement of cooling fanof motor as per existing size, type, make & model. Of Capicity 7.5HP to 05 HP
M&L for strip opening of electric motor after electrically disconnecting 1 to 3.0 HP pump for rewinding / replacement of unsv parts & reassembling the same & testing on load at existing place in presence of Engr-in-Charge. transporting from wk place to wksp & wksp to wk place shall be deemed to be included, all other spare parts / rewinding wk, material shall be measured and paid seperately here-in-after. All as directed by Engr-in-Charge.
Rewinding of motor of capacity 03 HP with superenamelled pre-insulationed copper winding wire of existing size of copper wire with insulated paper / bamboo chips, empire tape / glass tape etc & tesing after completion of job.
Rewinding of motor of capacity 02 HP with superenamelled pre-insulationed copper winding wire of existing size of copper wire with insulated paper / bamboo chips, empire tape / glass tape etc & tesing after completion of job.
Rewinding of motor of capacity 1.5 HP with superenamelled pre-insulationed copper winding wire of existing size of copper wire with insulated paper / bamboo chips, empire tape / glass tape etc & tesing after completion of job.
Rewinding of motor of capacity 01 HP with superenamelled pre-insulationed copper winding wire of existing size of copper wire with insulated paper / bamboo chips, empire tape / glass tape etc & tesing after completion of job.
Replacement of NDE/DE bearing as per existing size, type, make & model. Of Capicity 1HP to 3.0HP
Replacement of cooling fan as per existing size, type, make & model. Of Capicity 1HP to 3.0 HP
Hiring of JCB/ Cranes with operator & fuel for mechanical work at site / as spl task work as and when demanded, record shall be maintained for hours run on register and duly signed by Engr-in-Charge.
Supply and fixing post top lantern LED type 20 watt 230 volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete al as specified and directed by Engineer in Charge. Make: Bajaj, Crompton, Philips.
M&L for rewinding the exhaust fan of any make with super enamelled copper wire of suitable for incl all insulating materials varnishing complete incl satisfactory test run on load complete for :- (a) 300 mm/450mm sweep exhaust fan any make
Supply and fix in repair D shine MCCB for motor backup protection 3 Pole rated 400 Amps,breaking capacity 50 KA. Ics = 100% ICU Including Spreader Link, Copper lugs et between phase Cat part No CM94516OOROOG Model/Type DN3-400M, Make- L&T, or Cat part No XF3H400PV, Make- BCH, or equivalant model in seimens
Supply and fix in repair D shine MCCB for motor backup protection 3 Pole rated 250 Amps,breaking capacity 50 KA. Ics = 100% ICU Including Spreader Link, Copper lugs etc between phase Cat part No CM92171OOPOOG, Model/Type DN2-250M, Make- L&T, or Cat part No XF2H250PV, Make- BCH, or equivalant model in seimens
Supply and fix in repair D shine MCCB for motor backup protection 3 Pole rated 160 Amps,breaking capacity 50 KA Ics = 100% ICU IncludingSpreader Link, Copper lugs et between phase . Cat part No DZ1T0160NXM1A , Model/Type DZ1-160M, Make- L&T, or Cat part No XF2H160PV Make- BCH, or equivalant model in seimens
Supply and fix in repair D shine MCCB for motor backup protection 4 Pole rated 125 Amps,breaking capacity 50 KA Ics = 100% ICU . Including Spreader Link, Copper lugs et between phase Cat part No DZ1T0125NXM1A , Model/Type DZ1-160M, Make- L&T, or Cat part No XF2H125PV Make- BCH, or equivalant model in seimens
Supply and fix in repair D shine MCCB for motor backup protection 4 Pole rated 250 Amps,breaking capacity 50 KA. Ics = 100% ICU Including Spreader Link, Copper lugs etc between phase Cat part No CM92009OOP1OG, Model/Type DN2-250D, Make- L&T, BCH, or equivalant model in Legrand
M&L for preparation of old painted surface of pipe lines of size 100/150/200/250/300/350/400mm and protect meters,switches,moving parts from painting and paint with spray gun with one coat of existing colour complete all as specified and directed.
Disconnecting of all electrical connection, M&L for prepraction of old painted surface with the help of paint remover,scrapper & fine ambery paper and painting with two coat of heat resistance paint with the help of spray gun over one coat of red oxide and writing SM No/ Machine No and connect back all electrical connections complete all as specified and directed on following Capicity Pump set (Motor+Pump+ Foundation Frame):- (a) 100 to 150 HP.
(b) 50 to 75 HP
(c) 10 to 20 HP
Supply and laying XLPE insulated PVC innersheathed multi stranded armoured copper conductor cable 1100 volts grade single core from LT panel to starter and starter to motor, complete laid in floor/wall or cable duct including fixing with appropriate Copper lugs, spreader links etc all as directed of sizes 95 sq mm
Supply and laying XLPE insulated PVC innersheathed multi stranded armoured aluminium conductor cable 1100 volts grade four core, complete laid in floor/wall or cable duct including fixing with appropriate Copper lugs, spreader links etc all of size 16 sq mm.
S&F in replacement of chlorine test kit complete with box all as directed by EIC
M&L for replacement in earthing complete with galvanized steel earth plate electrode, 60Cm X60 Cm X 6.0 mm thick, buried directly in ground (earth pit not less than 2.25 Mtr deep below ground level) with top edge of the earth plate not less than 1.5 Mtr below normal ground level, connected to galvanized earth strip 32x6 mm by means of galvanised iron or steel with 40mm dia GI pipe light grade for protection of earth strip and all as shown in electrical plate No. 3 connected to elelctrical equipments all as specified or indicated including Exc & earth work, constn of PCC pit with RCC cover, watering pipe 20mm dia light grade with funnel & wire mesh & testing on completion all as directed. cost of earth strip of size 32x6mm up to 7.5 mtr deemed to be included in the rate quoted by contactor
Supply and fix GI earth strip of size 32x6mm
M & L for Replacement of existing filter media consisting of gravel and sand in water purification plant having working pressure 25 PSI H. Pn 50 PSI at senapati Bhawan as per details given below all as directed by Engr-in-Charge. (a) Removing the existing filter media consisting of gravels and sand, spreading and leveling out side for refilling, cleaning the surface, walls, bed sand Nozzles with wire brushes and cleaning the walls with bleaching powder solution, washing with fresh water and finally washing the complete filter bed twice with Anti bacterial spray treatment in all respect, and cleaning with high pressure water nozzle spray etc complete. (b) Refilling the filter media in the filter bed, gravels (pebbles) removed from the existing filter media after the washing pebbles with 5% ( Dil)Diluted aquous solution of Hydrochloric Acid (HCL) and treatment with 10% ( Dil)Diluted aquous solution of NAOH (sodium Hydro Oxide) and laying and stacking in different layers into filter beds. (c) Painting of complete filter assembly including incoming and outgoing pipe with two coat of synthetic enamel paint after scraping the old surface.
M & L for Replacement of existing filter media consisting of gravel and sand in filter bed tank having filtration capacity 32 lakh ltr /12 hrs at swimming pool as per details given below all as directed by Engr-in-Charge. (a) Removing the existing filter media consisting of gravels and sand, spreading and leveling out side for refilling, cleaning the surface, walls, bed sand Nozzles with wire brushes and cleaning the walls with bleaching powder solution, washing with fresh water and finally washing the complete filter bed twice with Anti bacterial spray complete in all respect, Anti bacterial spray with high pressure water nozzle spray cleaning etc complete. (b) Refilling the filter media in the filter bed, gravels (pebbles) removed from the existing filter media after the washing pebbles with 5% (Dil) Diluted aqous solution of Hydrochloric Acid (HCL) and treatment with 10% (Dil) Diluted aqous solution of NAOH (sodium Hydro Oxide) and laying and stacking in different layers into filter beds. (c) Painting of complete filter assembly including incoming and outgoing pipe with two coat of synthetic enamel paint after scraping the old surface.
Supply and filling filter media conisting of screened graded sand on supporting gravel bed of size 0.5 to 1.5 mm to suit existing size and type all as spd and directed
Supply and laying pebbles 8 mm to 25 mm in different sizes to suit existing size and type all as spd and directed .
Supply and laying pebbles upto 6 mm in different sizes to suit existing size and type all as spd and directed.
Supply and fixing Mild steel or iron work in heavy size for Fabricate of foundation Base frame for Pumps and motor including drilling holes riveting or welding where necessary and their fixing required for proper completion of work all as specified and as directed by EIC.
S&F in replacement of factory made 1-Phase DOL with 2P CPG Contactor & 2P Overload Relay DOL motor starter suitable for upto 3 HP motor complete with start stop push buttons powder coated enclosure with PU gaskets consisting of 1Ø, 220V, 50Hz, Overload Relay Range17.4 - 24.0 (A) Contactor Type 2P CPG,Contactor Rating 25A,Make BCH model HSN: 8536 cat code NAMBW-SP or equivalent
S&F in replacement of DOL submersible pump motor starter 3-PH complete powder coated enclosure with PU gaskets with protection consisting of,phase failure , phase imblance, phase reversal, short circuit protection, ammeter, voltmeter,ON/ OFF and trip indication, dry run preventor, start stop push buttons, suitable upto 10 HP motor including 3 core 10 sqmm submersible cable if required and of Overload Relay Range 13 - 20.0 (A),Contactor Rating 20A, with coil voltage 380-415V Make BCH HSN code: 8536, model type SHAKTI P10 cat code CPEYSBLZ or equivalent
S&F in replacement of DOL submersible pump motor starter 3-PH complete powder coated enclosure with PU gaskets with protection consisting of,phase failure , phase imblance, phase reversal, short circuit protection, ammeter, voltmeter,ON/ OFF and trip indication, dry run preventor, start stop push buttons, suitable upto 5/7.5 HP motor including 3 core 10 sqmm submersible cable if required and of Overload Relay Range 13 - 20.0 (A),Contactor Rating 20A, with coil voltage 380-415V Make BCH HSN code: 8536, model type SHAKTI P10 cat code CPEYSBLZ or equivalent
Excavation in trenches not exc 1.5m width and not exc 1.5 m in depth and getting out for laying of pipes etc in soft/loose soil .
Returning filling in including spreading levelling watering and ramming in layers not exceeding 25 cm in any type of soil.
Removing of excavated surplus soil to a distance not exceeding 50M where directed and at a level not exceeding 1.5 M above the starting point.
M&L PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) in support of pipes or foundation of pump complete all as directed.
Supply and fixing in repair CI foot valve flanged/threaded type of dia 50 mm as per existing including accessories like nut-bolt, gasket etc as required complete in all respect as directed by Engineer-in- Charge.
All as per item No. 156 above but dia of foot valve 80 mm
All as per item No. 156 above but dia of foot valve 100 mm
Material and labour for maintenance of complete scada system of water Supply with all Slave panels , PLC panels around 24 places under Army Area Jodhpur like, greasing and cleaning of actuator,cleaning and checking connection of Magnetic float sensor, cleaning and setting of solenoid Valve,cleaning and setting of pressure switch, setting of limit/torque switch, checking and repalcement of minor parts like ferrule/lugs and tighten the loose electrical connection , replacement of unserviceable nut, bolt and key etc and kept record as per format provided in register and put to Engr-in charge at every month , replacement of u/s spare parts shall be measured and paid separately. all as directed by Engr-in-Charge. Note - Rate of all sundry item like waste cloth, grease, ferrule/Lugs, nut , bolt , key and tools required for servicing etc shall be deemed to be included in the rate quoted by contactor. if contactor fails to carry out servicing every month an amount of Rs 2500/months shall be deducted from the payment due to contractor
Supply and fix SMPS unit suitable for out put 24 volt DC and input 230 volt AC of rating 2.5 Amp as per exiting sample/ size Make: Schneider/NHP or equivalent make
Supply and fix only single phase preventor /single phase relay as per model VSP D 2 / VSP3 type or as per exiting sample/ size having system AC aux supply 415 volt 50 HZ Make : - Minilac/Indo Power /Schnieder/L&T
Supply and fix relay pin type 4C/O , 220 -240Volt AC or as per exiting sample/ model no RU4S-A220 Make : LEONE / IDEC/L&T/Schneider
Supply and fix relay pin type 4C/O , 24 Volt DC or as per exiting sample/ model no RU4S-D24 Make : LEONE / IDEC/L&T/Schneider
Supply and fix indicator lamps of colour red / green/ yellow as per exiting sample/ size Make : ESBEE / Schneider /L&T or equivalent make
Supply and fix push button with Led indicator red/ green type -240 Volt Ac as per exiting sample/ size Make : ESBEE / Schneider / L&T
Supply and Commissioning of wireless communication modem that’s suitable for existing PLC Panel including programming and compatible with existing system (at Security Section, SMC & Spare), Network type 4G/3G/2G, Supports all types of M2M SIMs, Two Serial Ports for RS232 and RS485 for external device interface, LED indicators provide network information, Supports MODBUS/RTU, Data transfer protocol to remote server via TCP/IP, Cellular Interface Standards: GSM/GPRS/EDGE/UMTS/ HSPA/FDD LTE, GPRS/EDGE: 850/900/1800/1900 MHz, Power supply : 24 V DC, Operating temperature: -20 deg to 60 deg. Make : AsCom /Maestro/ MCom or equivalent make
Supply and fix in replacement of Water Level Controller Relay Card (10 levels) Make : As per sample to suit existing system and ensure perfect serviceabilty.
Supply and fix in replacement of Water Level Controller Relay Card (05 levels) Make : AAs per sample to suit existing system and ensure perfect serviceabilty.
Supply, Installation, Testing and commissioning of Pressure Switch of designed line pressure 1-10KG/sq.cm with Pressure Guage and necessary fittings with proper wiring and to be fixed in deliver line of each pump as directed by Engineer in charge. Make: Indfos/Danfoss/L&T
Supply, Installation, Testing and commissioning of Air releasing solenoid valve having 15/20 mm dia, 230 V AC operated coil complete all as specified & directed. Make: ROTEX / AVCON / ASCO / UFLOW
Supply and fix in replacement of MCB 16 Amps, 415 V,10KA, TPN, "C" curve, Make- Havells, Legrand,schneider
Supply and fix in replacement of MCB SPN 10 Amps, 230V,10KA, SPN, "C" curve, Make- Havells, Legrand,schneider
Supply and fix in replacement of Butterfly valve of size 100 mm dia.PN 16 suitable for coupler with Existing actuator operation rate for modification in adopter to make fit with existing actuator shall be deemed to be included in rate quoted by contactor. Make: AUDCO/L&T/Kartar or equivalent
Supply and fix in replacement of Butterfly valve of size 150 mm dia.PN 16 suitable for coupler with Existing actuator operation rate for modification in adopter to make fit with existing actuator shall be deemed to be included in rate quoted by contactor. Make: AUDCO/L&T/Kartar or equivalent
Supply and fix in repalacement of Butterfly valve of size 200 mm dia.PN 16 suitable for coupler with Existing actuator operation rate for modification in adopter to make fit with existing actuator shall be deemed to be included in rate quoted by contactor. Make: AUDCO/L&T/Kartar or equivalent
Supply and fix in replacement of Butterfly valve of size 250 mm dia.PN 16 suitable for couple with Existing actuator operation rate for modification in adopter to make fit with existing actuator shall be deemed to be included Make: AUDCO/L&T/Kartar or equivalent
Supply and fix in replacement of Butterfly valve of size 300 mm dia PN 16 suitable for coupler with Existing actuator operation rate for minor modification in adopter to make fit with existing actuator shall be deemed to be included in rate quoted by contactor. Make: AUDCO/L&T/Kartar or equivalent
Supply and fix in replacement of Capacitor 7 UF for Actuator suitable for 80mm/100mm/150mm dia Butterfly Valve actuator
Supply and fix in replacement of Capacitor 10UF for Actuator suitable for 200mm/250mm/300mm dia Butterfly Valve actuator
Supply and fix in replacement of Limit Switch ( Micro Switches) for Actuator suitable for 300mm/250mm/200mm/ 150mm/100mm/80mm dia Butterfly Valve. Make : As per sample to suit existing size, type and model system
Supply and fix in replacement of torque Limit Switch With 2 NO +2 NC for Actuator suitable for 400mm dia Butterfly Valve Make : As per sample to suit existing size, type and model system
Supply & Laying 5 pair 0.5 sqmm dia. armoured communication cable with copper conductor for sensor. Make: Polycab/FINOLEX/Havells
Supply & Laying 7 Core 1.5 sq. mm PVC sheath PVC insulated copper conductor armoured cable. Make:Polycab/FINOLEX/Havells
Supply & Laying High density polyethylene pipes (HDPE) double wall corrugatted (DWC) of pressure rating 6 kgf/cm2 and of size 50 mm laid in trenches along with the appropriate size of cables for protection all as specified and as directed by EIC.
Taking down carefully after disconnecting electrically to UNSV electric motor 3 phase of Electromechanical valves of size 400mm. Sytrip opening of motor replacement of complete winding with existing size supiriour enamelled copper winding wire, replacement of bearing of NDE/ DE as per site , reassemblking and testing upto entire satisfaction of Engr-in-Charge.
Taking down carefully after disconnecting electrically to UNSV electric motor single phase of Electromechanical valves of size 300mm. Sytrip opening of motor replacement of complete winding with existing size supoer enamelled copper winding wire, replacement of bearibg of NDE/ DE as per state , reassembling and testing upto entire satisfaction of Engr-in-Charge.
All as per Item No 186 above but for 250mm dia Electromechanical valves
All as per Item No 186 above but for 200mm dia Electromechanical valves
All as per Item No 186 above but for 150mm dia Electromechanical valves
All as per Item No 186 above but for 100mm dia Electromechanical valves
All as per Item No 186 above but for 80mm dia Electromechanical valves
Taking out old and Supply, fix in replacement of casing cover, shaft, impeller with all accessories including bearing of 100/150hp pump as per existing complete all as specifed and directed by Engr-in-charge. Make:- Kirloskar/Crompton/KSB or equivalent
Supply, fix and commissioning in replacement of Digital Soft Starter of capacity 150HP, Main 200-525Vac, CT5 110-240Vac with Built in bypass contactor, Smart card for level controlled pump activation and pump protection ,Fire Mode Function Advanced protection system, Real time graphs of motor operating performance and USB port for easy and fast commissioning and data extraction 384 event logs with time stamping Under Voltage / Over Voltage protection, graphical display with multi language support, advanced protection system. Make: L&T/ABB/Schinder
Supply, fix and commissioning in replacement of Digital Soft Starter of capacity 12.5HP, Main 200-525Vac, CT5 110-240Vac with Built in bypass contactor, Smart card for level controlled pump activation and pump protection ,Fire Mode Function Advanced protection system, Real time graphs of motor operating performance and USB port for easy and fast commissioning and data extraction 384 event logs with time stamping Under Voltage / Over Voltage protection, graphical display with multi language support, advanced protection system. Make: L&T/ABB/Schinder
Supply, Installation, Reprogramming,Testing and Commissioning of Input/Output Expansion Module that’s suitable for existing PLC Panel with Extension cable type, Digital input 08 , Input type Sink/source, Input display LED, Input specifications 5.3 mA/24 V DC (X20 and later: 4.0 mA/24 V DC) /Digital output 08 , Output type Transistor/ source output, Output display LED, Transistor output type: 0.5 A/1 point, 0.8 A or less/4 points common, 1.6 A or less/8 points common 5 to 30 V DC Make: Unitronics/Mistsubishi/GE Fanuc /Schneider
Supply and fixed in replacement of defected/ burn out /unsafe internal control wiring for automation main master panel or automation slave panel installed at variours pump house for scada system as per existing system by using copper bottle lugs, copper ferrule,including marking with cable marking ferrule of the following Size (a) PVC insulated and unsheathed flame retardant Low smoke ( FRLS ) cable of 2.5 sqmm (nominal area) with multi stranded copper conductor electric wire single core 1100 volts grade
All as srl item No. 196 above but PVC insulated and unsheathed flame retardant Low smoke ( FRLS ) cable of 0.5 sqmm (nominal area) with multi stranded copper conductor electric wire single core 1100 volts grade
Supply & Laying High density polyethylene pipes (HDPE) double wall corrugatted (DWC) of pressure rating 6 kgf/cm2 and of size 20 mm laid in trenches/ along wall/ drain along with the appropriate size of cables for protection all as specified and as directed by EIC.
Supply and fix as in replacement of mettalic body resistor for Actuator suitable for 300mm/250mm/200mm/ 150mm/100mm/80mm/dia butter fly valve actuator As per sample to suit existing size, type and system
Supply and fixing in replacement of modular surge arrester TPN, 350V secondary protection of loads to be protected and in placed in cascade with the incoming surge arresters, combined surge arrester type 2+3 8ka according to IEC 61643-11:2011, suitable for TT amd TN-S networks with high prospective short-circuit fault currents all as directed by Engr-in-charge.
Supplying and fixing in replacement of communication cable PLC to HMI port, including adopter panel to panel, panel to PC, control cable with M/F socket of existing pin fixed as in repair complete all as directed by Engr-in charge
Supply and fixing in replacement of 2/3 way Auto and Mannual slector switch for scada water supply system as per existing make and model fixed as in repair complete all as directed by Engr-in charge.
Supply and fixing in replacement of on/off slector switch for SCADA water supply system as per existing make and model fixed as in repair complete all as directed by Engr-in charge.
M&L for servicing of Laser Jet Printer model-CP1025 color Make HP
M& L for servicing of smart UPS 3000VA Make APC .
Supply, Installation, Testing and commissioning of Priming solenoid valve having 20/25 mm dia, 230 V AC operated coil complete all as specified & directed. Make: ROTEX / AVCON / ASCO / UFLOW
Supply and fix rust proof maintenance free single point Magnetic float/water level sensor with float size 3 MTR water level sensor/as per existing for OHT / UG sumps. Make RDS/ATS or Eqvt make as per existing
Supply & Fixing Three Phase Electric motor suitable for actuator for 400 mm dia. Butterfly valve Make : Ritetork / Emtork / Astech
Supply & Fixing Single Phase Electric motor suitable for actuator for 300 mm dia. Butterfly valve Make : Ritetork / Emtork / Astech
Supply & Fixing Single Phase Electric motor suitable for actuator for 200 mm dia. Butterfly valve Make : Ritetork / Emtork / Astech
Supply & Fixing Single Phase Electric motor suitable for actuator for 150 mm dia. Butterfly valve Make : Ritetork / Emtork / Astech
Supply & Fixing Single Phase Electric motor suitable for actuator for 250 mm dia. Butterfly valve Make : Ritetork / Emtork / Astech
M&L for Making adopter to couple with existing actuator and butter fly valve for smooth function of 100mm to 400mm Electromechanical valves
Supply and fix in replacement of only motor actuated valve of size 300 mm dia complete single phase motor actuated with gear box valve set with disc material of CI with nylon coating, hand wheel for manual operation, pressure rating of 10 kg/sq cm and having 02 nos limit switches for open / closed condition and capability of accepting 4-20mA input complete set Make-Ritetork/Astech/Emtork.
Supply, Installation, Testing and Commissioning of motor actuated valve of size 150 mm dia complete single phase motor actuated with gear box valve set compatible, hand wheel for manual operation, pressure rating of 10 kg/sq cm and having 02 nos limit switches for open / closed condition and capability of accepting 4-20mA input complete set Note: Motor Actuated Valve should be compatible with existing SCADA ( All the functions of Motor Actuated Valve should be control remotely from existing SCADA) Make-Ritetork/Astech/Emtork
Supply, Installation, Testing and Commissioning of motor actuated valve of size 200 mm dia complete single phase motor actuated with gear box valve set compatible, hand wheel for manual operation, pressure rating of 10 kg/sq cm and having 02 nos limit switches for open / closed condition and capability of accepting 4-20mA input complete set Note: Motor Actuated Valve should be compatible with existing SCADA ( All the functions of Motor Actuated Valve should be control remotely from existing SCADA) Make-Ritetork/Astech/Emtork
Supply and fixed in replacement of defected/ burn out /unsafe internal control wiring and connection for automation main master panel or automation slave panel installed at variours pump house for scada system as per existing system and including using by FR PVC insulated electric wire with copper conductor wiring having of single core of size 0.5 sqmm to 1.0 sqmm sub wiring as properly electrical connection for smooth controlling panel of scada system including resetting of system complete and testing all as specifed and directed by Engr-in-charge
Supply, Installation, Testing and Commissioning of HMI that’s suitable for existing PLC Panel - Touch screen, TFT 7” Colour Liquid crystal display, Display character 16-dot standard font: 50 characters x 30 rows (two-byte characters), Display colour more then 10k, 32-level brightness, Built in interface with RS 232, RS485/422, Ethernet, USB, SD card, Internal Flash memory 15MB, Input power supply voltage 24VDC(+10% -15%) Ripple voltage 200mV or less, operating temperature :0 deg to 50 deg / storage temperature : -20 deg to 60 deg Make :Unitronics / Mitsubishi /Renu
Removing of all natural beehive all around from over head tank upto height of 24 mtr all as specified and directed by engr-in-charge. note:- All neccessory safety equipment and responsibility of contractor.
Taking out old and Supply, installation, testing and commissioning LT 415 Volt, 4 wire AC 50 Hz, factory made, floor mounted out door type Panel of size 2.3 x 2.0 M, centre opening in two halve front and back both door ,inner door shall be individual hinged type door for individual control switches made out of CRCA sheet 2.0 mm thick and outer door made out of 3 mm thick with locking arrangement , duly powder coated and along with gable roof & mounted on angle iron frame , made out of 60 x60 x6 mm angle iron frame and legs made of angle iron of size 60 x 60 x 6 mm 60 CM long total 06 nos in which 04 Nos one at each corner and 02 nos at center duly fixed with PCC etc incl control wiring with 10 Sqmm Copper wire including copper bus bar of suitable capacity complete to accommodate the following accessories :- .(a) MCCB 250 Amp ,36 KA, 4 pole ,415 Volts adjustable type– 01 N0 (b) Ammeter ,Digital type having scroll type switch with CT’s-01 Set (c) Voltmeter Digital type in one position having scroll type switch with PTs - 01 Set(d) LT danger notice plate made out of 1.6 mm thick MS sheet - 01 No (e) Indicator lamp LED type (set of 3) - 1 set (f) Soft starter of capacity 15 to 50 A- 02 Nos (g)Single phase preventor (h) MCCB TPN 40 Amp - 03 Nos. (j) MCCB 4 pole 100 amp - 02 no. (k) MCCB 3 Pole 100 amp - 02 no. (l) MCB 03 pole 25 amp - 01 no etc. Note :- 1. Rates quoted must be included of panel accessories like cable gland, control wiring, Bus bar, Digital Ammeter, Voltmeter, danger plate, indicator lamp, push button, single phase preventor, MCCB, MCB, angle iron for base and legs, PCC etc. 2. Soft starters if required shall be measured and paid for separatively.
Material and labour for spray painting to outdoor type double door LT panels/feeder pillar box and replacement of door hinges, sliding bolts, cable entry MS sheets, cable glands, pedestal locks, bow handle and connected accessories where required by welding, cutting, drilling etc and incl fixing with MS nuts and bolts and cleaning of panels from inside and outside and removing any faulty part of cable and preparing the cable for connection with suitable Al lugs and insulating with proper colour code PVC tape whereever required and including two coats of spray painting by synthetic enameled paint complete all as specified and directed by Engr-in-Charge. Note:- 1) Proper shut down will be taken by the authorised rep only. 2) Panel should be made vermin proof and close properly after repair.
Material and labour for shifting of outdoor type double door LT panel/feeder pillar box to a location indicated by EIC by removing the panel from ground, disconnecting all cable connections and connected accessories and including embedment of panel in ground with proper PCC and reconnecting all the LT cable connections with proper lugs, nut bolts etc where required by welding, cutting, drilling etc and incl fixing with MS nuts and bolts and cleaning of panels from inside and outside and removing any faulty part of cable and preparing the cable for connection with suitable Al lugs and insulating with proper colour code PVC tape whereever required complete all as specified and directed by Engr-in-Charge. Note:- 1) Proper shut down will be taken by the authorised rep only.
M&L galvanised iron pipe medium grade of size 15 mm (ISI marked) with and including medium grade (ISI Marked) fitting concealed or fixed to walls, celling or laid in floors including chase cuttings where required, making good to distributed surfaces as per existing as directed and specified of the following sizes:- Note: Cost of cutting/leaving/forming chases, holes etc through walls, floor, plinth protection, roof etc as required and making good the surface to match as per existing shall deemed to be included in quoted rate by the tenderer. Make: Jindal, Prakash Surya, Tata
All as per item No. 223 here-in-above but of size 20 mm
Supply and fix gun metal gate valve of size 15 mm with iron wheel head screwed both ends for iron pipe and fixed of following sizes incl taking down and removal from site:- Make: Leader, Sant, Zoloto
Supply and fix gun metal gate valve of size 20 mm with iron wheel head screwed both ends for iron pipe and fixed of following sizes incl taking down and removal from site:- Make: Leader, Sant, Zoloto
Reprogramming of Automation slave panels intalled at Multan Line pump house for scada system as per existing system for smooth controlling panel of scada system including resetting of system. Note: Downloading and uploading of the PLC Programms carried out only in the presence of well known scada automation technician.
Integrate, Modification of the program and Creation of additional screens and soft keys to facilitate remote monitoring and operation of the new motor actuated valves and PLC. The scope of work includes modification of the existing SCADA system and its formats so as to include the status of the said Automation Slave Panels .
Supply, Reprogramming and Fixing PLC (Programmable Logic Controller) that’s suitable for existing PLC Panel with connected power supply system, I/O Module expansion adaptors, Program capacity 64/128 k steps, High-speed counter function (max. 8 ch), Command processing time 34 ns, 40 Digital input + 40 Digital output , Input type Sink/source, Input display LED, Input specifications 5.3 mA/24 V DC (X20 and later: 4.0 mA/24 V DC) /Output type Transistor/ source output, Output display LED, Transistor output type: 0.5 A/1 point, 0.8 A or less/4 points common, 1.6 A or less/8 points common 5 to 30 V DC / 2 communication ports RS-485 Port and Ethernet port / Max. number of control points 512*4 points/ Power supply : 24 V DC/ permissible range : 20.4VDC to 28.8VDC with less than 10% ripple/ 100 to 240 V AC, 50/60 Hz / SD memory card slot / operating temperature :0 deg to 50 deg / storage temperature : -20 deg to 60 deg. Make : Unitronics/Mistsubishi/GE Fanuc /Schneider
Chamunda construction company (BID ID -3461962)
M/s R K Enterprises (BID ID -3461975)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.37 MB
BOQ_821050.xls
BOQ • 1.54 MB
TENDER53.pdf
Tender Documents • 0.80 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .