Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.4 LAccepted-AOC 9 8 B THENGUMTHARAVIL MLA ROAD PANANGAD PO KOCHI 682506 | KOCHI | ERNAKULAM | KERALA | 682506 | ₹14.4 L Quoted ₹14.6 L | L1 | Accepted-AOC Lowest Bidder |
| 2 | L2₹15.9 L+₹1.3 L (8.92%)Rejected-Finance DOOR NO 32 939C 1ST FLOOR CITY SCAPE BUILDING CHANGAMPUZHA NAGAR P O SOUTH KALAMASSERY ERNAKULAM KERALA 682033 | ERNAKULAM | KERALA | 682033 | ₹15.9 L+₹1.3 L (8.92%) | L2 | Rejected-Finance Higher Bid Value |
| 3 | L3₹19.9 L+₹5.3 L (36.5%)Rejected-Finance NO 68 ANJANEYA TEMPLE CROSS OPP M S RAMAIAH HOSPITAL NEW BEL ROAD BANGALORE 560 094 | BENGALURU URBAN | KARNATAKA | 560094 | ₹19.9 L+₹5.3 L (36.5%) | L3 | Rejected-Finance Higher Bid Value |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
18 Mar 2020, 6:00 pmClosed
Col Aman Vashisht CWE
CWE Ezhimala INA Ezhimala PO Kannur Kerala 670310
Repair/maintenance of fire fighting system, pump house at Kautilya Auditorium and INHS Navjivini Hospital including fire detection and fire alarm system at INA Ezhimala
2020_MES_326295_1
80400/E8
Open Tender
Miscellaneous Works
Item Rate
120 days
Ezhimala
As per Tender Documents
2 documents required · 2 mandatory
₹500
GE (Maint) Ezhimala
₹50,000
Yes
2 Jul 2020
18 Feb 2020
20 Mar 2020
18 Feb 2020
18 Mar 2020
3 Mar 2020
18 Feb 2020 - 3 Mar 2020
Amount
LIST OF ITEMS OF WORKS
Servicing of diesel engine driven high pressure fire pump of following capacity at Fire Pump House at INA Ezhimala by servicing all accessories PT pump injectors, wood ward governor, self starter, Radiator, dynamo, engine wiring, terminal contacts and safety controls etc., including replacement of spare parts as required (spare parts shall be measured and paid separately under relevant items) and reassembling sub assemblies after carrying out necessary repairs and painting with one coat of synthetic enamel paint testing, commissioning as directed by Engineer-in-Charge. Make : Kirlosker:
108 BHP capacity Diesel engine
38 BHP capacity Diesel engine
Material and labour for refilling fire extinguisher for following type and capacity complete all as directed by Engineer-in-Charge :-
DCP stored pressure - 9 kg capacity
CO2 - 4.5Kg capacity
AFFF foam - 9 liters capacity
Preparing surfaces of fire hydrant pipe line up to 150mm dia by scrapping old rusted paint with and including applying two coats of synthetic enamel paint of fire red colour over one coat of red oxide primer including marking fire hydrant flow complete all as directed by Engineer-in-Charge
Taking down carefully electric motor 3phase, 415v, 50Hz, AC from foundation/coupling, transporting to civil workshop, opening motor, checking insulation value of the windings, insulating the winding with same class of insulation, painting with one coat of synthetic enamel paint as per color code and transporting back to site for re-installing motor and connecting to pump, testing the motor for satisfactory performance complete all as directed by Engineer-in-Charge for the following capacity :-
S&F addressable monitor module for beam detector including taking down old unserviceable item complete all as directed by Engineer-in-Charge. Make : Honeywell/Notifier
S&F Dial type pressure gauge (4"Dia) (Firebug) 0-21 kgs including taking down old unserviceable item acomplete all as directed by Engineer-in-Charge.
S&F Single pressure switch, universal type to suit the system including taking down old unserviceable item acomplete all as directed by Engineer-in-Charge.
S&F Air release valve 25mm dia including taking down old unserviceable item complete all as directed by Engineer-in-Charge.
Replacement of Gun metal fire Hydrant valve with 5mm flanged inlet and 63 mm female single instantaneous outlet complete with Lug & Chain as per IS-5290 Hydrostatically tested to 21 Kgf/cm2 of pressure having a flow rate of 900 LPM at 7Kgf/m2 complete all as directed by Engineer-in-Charge.
Supply only fire hose 63 mm dia confirming to IS: 636, 15 meter length including gunmetal heavy duty pair of male and female couplings complete all as directed by Engineer-in-Charge.
Supply only gunmetal branch pipe with male threaded nozzle of 15mm and male instantaneous inlet of 63 mm dia as per IS : 903.93 complete all as directed by Engineer-in-Charge.
Supply and fix butterfly valve 100mm slim seal standard lever operated type confirming to IS: 13039 complete all as directed by Engineer-in-Charge.
Preparing surfaces of fire control cabinet out door type of size 0.50mX0.50mX0.30m by scrapping out old rusted paint and necessary snickering and applying two coats of synthetic enamel paint over one coat red oxide primer by spray painting complete all as directed by Engineer-in-Charge.
Repair of microprocesser based fire alarm control panel NOTIFIRE FS 3030, having six loop data card, battery, LCD panel, buzzers required software program etc, including testing all as directed. Note: The unit rate quoted shall include for regular inspection, maintenance/servicing of loop wiring, heat / smoke detectors, response indicator, MCP, sounder cum scob with control module complete all as directed by Engineer-in-Charge.
Supply and fix multi criteria detectors with base for below for false ceiling model FAPT 851B501 including taking down old unserviceable complete all as directed by Engineer-in-Charge. Make : Honey well or Equivalent
Supply and fix manual call point resettable type complete all as directed by Engineer-in-Charge. Make : Honey well or equivalent
Supply and fix sounder cum storb with control module with taking out old unserviceable acomplete all as directed by Engineer-in-Charge. Make : Honey well or equivalent
Supply and fix Sprinkler with taking out old unserviceable complete all as directed by Engineer-in-Charge. Make : Honey well or equivalent
Painting to valve chamber and cast iron cover with synthetic enamel paint of fire red colour including marking with white colour paint complete all as directed by Engineer-in-Charge.
Excavation in trenches n.exc 1.50m wide and n. exc 1.50m in depth and getting out in hard/dense soil including trimming the sides and forming bottom surface to required levels for laying pipes complete all as specified and as directed.
Returning, filling in including spreafing, levelling, watering and well ramming in trenches with soil obtained from excavation in layers n.exc. 25 cm complete all as specified and as directed.
Removing surplus excavated soil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and as directed
Supply and replace rubber bush for pump coupling suitable for the following capacity of pumps
75KW/100HP motor
15HP/11KW motor
Repairs to CI sluice valves by taking out gland sleeve, check nut spindle, gate etc. and cleaning the valve by removing all scales and reassembling the valve with new packing nut and bolts including painting with one coat of synthetic enamel paint all as directed by the Engineer-in-Charge for the following:
Sluice valve flanged type 200/ 150mm dia.
Sluice valve flanged type 100/ 80mm dia.
Repairs to CI Non return valves flanged type 150/100/80 mm dia by opening the cover and cleaning the valve by removing all scales, dirt etc and reassembling the valve with new packing nut and bolts including painting with one coat of synthetic enamel paint all as directed by the Engineer-in-Charge.
Material & lab our for attending breakdown of 150 mm dia pipe line bursting/cracks including broken pipe pieces of various sizes through gas cutting or manual cutting as required at site and providing new CI/MS/GI pipes of required length (not more than 2m) and removing out the damaged CI pipe and inserting necessary specials such as flanges etc as required at site including testing for the leakages of flange joints for 150mm dia MS/CI pipes complete all as specified and directed by Engr-in -charge Note:Excavation and earth work shall be measured and paid seperately under relevant item of this BOQ.
Material and labour for replacement of glass panel for indoor fire hydrent boxes as per site requirement by taking down old broken glass as specified and directed by Engr-in-Charge.
Supply and fill engine oil
Supply and fill coolant
Supply only fan belt for 40/100HP DG pump set
Supply only fuel filter40/100HP DG pump set
Supply only Oil filter40/100HP DG pump set
Supply only air filter40/100HP DG pump set
Supply and replace nut, bolt and washer in repairs of any size
Material and labour for CPU2-3030D,NFS2-3030 CPU with 640 character display.Make:Notifier
Material and labour for CA-2,chassis,DVC,two rows.Make:Notifier
Material and labour for DPA-2B,dress plate,DVC,two rows.Make:Notifier
material and labour for DVC-EM,digital voice command,extended memory.Make:Notifier
Material and labour for DVC-KD,Digital voice command keypad.Make:Notifier
Material and labour for AMPS-24E,Addressable power supply,240 VAC.Make:Notifier
Material and labour for NCM-W,Network communications module,twisted pair wire interface.Make:Notifier
Material and labour for CHS-4L chassis.Make:Notifier
Material and labour for LCM-320,loop control module.Make:Notifier
Material and labour for LEM -320,loop expander module.Make:Notifier
Material and labour for BP2-4,battery dress panel for CAB-4 series.Make:Notifier
Material and labour for TELH-1,fire fighters telephone handset only.Make:Notifier
Material and labour for FTM-1,telephone module.Make:Notifier
ALLIES FIRE SYSTEMS PVT LTD
devan enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .