Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.0 LAccepted-AOC | L1 | Accepted-AOC Technically qualified and Financially Accepted |
Tender Value
Refer Docs
Closing Date
20 Apr 2022, 3:30 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Chief General Manager (Water Transport)
Kochi Metro rail Limited, 4th Floor, JLN Metro Station, Kaloor Ernakulam, Kerala-682017
Supply and Installation of Steel Doors and Allied Works at High Court, Bolgatty and Vypeen Terminals and Vytilla OCC Building
2022_KMRL_484625_1
KMRL/PROC/TENDER/2021-22/081
Open Tender
Miscellaneous Works
Item Wise
45 days
Kochi
Please refer Tender documents.
17 documents required · 17 mandatory
₹5,900
Yes
Exempted
Kochi Metro rail Limited
5 Jul 2022
29 Mar 2022
21 Apr 2022
29 Mar 2022
20 Apr 2022
5 Apr 2022
29 Mar 2022 - 4 Apr 2022
2 Apr 2022
90 days
Hollow metal fire rated steel doors as per IS 3614 part-1 & part-2 for stability and integrity. Pressed Galvanized steel confirming to IS 277 with the following specification. Recommended fire door shall have doors tested at CBRI or ARAI for maximum rating of 2hrs with vision panel. Test certificates should be available for vision panels as part of the fire door assembly. Independent glass test certificates will not be accepted. Manufacturer test certificate shall cover doors both single and double leaf and all doors supplied should be within the tested specimen, deviation in specification and sheet thickness other than what is mentioned in the test certificates are not allowed. Proper label confirming the type of door and the hourly rating is mandatory by approved manufacturer. Colour of the door unit shall be RAL 7040. a. Door frame shall be Single rebate frame profile of size 125 x 60mm made out of 1.50mm minimum thick galvanized steel sheet. Frames shall be mitered, and field assembled with self-tabs. Frames to have in build grooved sealing system and shall be site fitted with EPDM gasket as standard. All provision should be mortised, drilled, and tapped for receiving appropriate hardware. Frames should be provided with back plate bracket and anchor fasteners for installation on a finished plastered masonry wall opening. Once frame installed should be filled with PUF or with cement & sand slurry as recommended by the manufacturer of the engineer.
b. Door leaf shall be 46mm thick fully flush double skin door with or without vision panel. Door leaf shall be manufactured from 1.15mm (18guage) minimum thick galvanized steel sheet. The internal construction of the door should be rigid reinforcement pads for receiving appropriate hardware. The infill material shall be resin bonded honeycomb core /96 density Rockwool insulation. c. All doors shall be factory prepared with necessary reinforcement for hinges, locks, handles, door stopper and door closers. The required hardware details per door is as follows: - • SS ball bearing hinges of size 100x75x3mm. Minimum 03Nos for 2100mm height. In each panel, • Hydraulic door closer – 1No per door leaf. • Door stopper – 1 No per door leaf • Mortise sash lock with SS liver handles (1 set for each panel) side with key operation The edges should be interlocked with a bending radius of 1.4mm. For pair of doors integrated astragals has to be provided on the meeting stile for both active and inactive leaf. All hardware shall be provided GEZE brand or equivalent fittings including all hardware’s in SS shall be of 304 grade with fire rating standards. d. Vision panel wherever applicable should be provided as per manufacturer’s recommendation with a clip-on arrangement. The glass should be 5mm clear borosilicate fire rated glass of relevant rating of the door by Approved hardware manufacturer / Supplier. Size of the vision panel of size 200x300mm.
Hollow metal fire rated doors as per IS 3614 part-1 & part-2 for stability and integrity. Pressed Galvanized steel confirming to IS 277 with the following specification. Recommended fire door shall have doors tested at CBRI or ARAI for maximum rating of 2hrs with vision panel. Test certificates should be available for vision panels as part of the fire door assembly. Independent glass test certificates will not be accepted. Manufacturer test certificate shall cover doors both single and double leaf and all doors supplied should be within the tested specimen, deviation in specification and sheet thickness other than what is mentioned in the test certificates are not allowed. Proper label confirming the type of door and the hourly rating is mandatory by approved manufacturer. All doors shall be prepared in the factory to receive the appropriate hardware’s. Colour of the door unit shall be “RED” a. Door frame shall be Single rebate frame profile of size 125 x 60mm made out of 1.50mm minimum thick galvanized steel sheet. Frames shall be mitred and field assembled with self-tabs. Frames to have in build grooved sealing system and shall be site fitted with EPDM gasket as standard. All provision should be mortised, drilled and tapped for receiving appropriate hardware. Frames should be provided with back plate bracket and anchor fasteners for installation on a finished plastered masonry wall opening. Once frame installed should be filled with PUF or with cement & sand slurry as recommended by the manufacturer of the engineer.
b. Door leaf shall be 46mm thick fully flush double skin door with or without vision panel. Door leaf shall be manufactured from 1.15mm (18guage) minimum thick galvanized steel sheet. The internal construction of the door should be rigid reinforcement pads for receiving appropriate hardware. The infill material shall be resin bonded honeycomb core /96 density Rockwool insulation. c. All doors shall be factory prepared with necessary reinforcement for hinges, locks, handles. The required hardware details per door is as follows: - a. SS ball bearing hinges of size 100x75x3mm (minimum 3nos per door leaf) b. SS Flush pull handles – 1 set c. Allen Key locking system – 1set d. Door stopper and Door Closer are not required for these doors. The edges should be interlocked with a bending radius of 1.4mm. For pair of doors integrated astragals has to be provided on the meeting stile for both active and inactive leaf. All hardware shall be provided GEZE brand or equivalent fittings including all hardware’s in SS shall be of 304 grade with fire rating standards d. The rate shall include the cost and conveyances of all materials, Fasteners, labor charges, lead, lift and necessary hardware like e. Vision panel wherever applicable should be provided as per manufacturer’s recommendation with a clip-on arrangement. The glass should be 5mm clear borosilicate fire rated glass of relevant rating of the door by Approved hardware manufacturer / Supplier. Size of the vision panel of size 450x450mm.
Providing and fixing of standard duty hollow metal doors confirming to IS 16074 & IS 4351 made of pressed galvanized steel confirming to IS: 277 with the following specification: Doors shall be with vision glass as a part of complete assembly. Colour of the door unit shall be RAL 7040. a. Door frame shall be single rebate ground profile of size 120 x 60mm made out of minimum 1.15mm (18 gauge) thick galvanized steel sheet. Frames shall be mitered only. Frames shall be field assembled with self-tabs. Bolted & butted joints are not acceptable. All provision should be mortised, drilled and trapped for receiving approximate hardware. Frames should be provided with back plate bracket and anchor fasteners for installation on a finished plastered masonry wall opening. b. Door leaf shall be 46mm thick fully flush double skin door, with or without vision lite. Door leaf shall be manufactured from minimum 0.8mm (22gauge) thick galvanized steel sheet. The internal construction of the door should be rigid reinforcement pads for receiving appropriate hardware of approved make. The infill material shall be Rockwool or resin bonded honeycomb core. The edge should be interlocked with a bending radius of 1.4mm. For pair of doors integrated astragals has to be provided on the meeting stile for both active and inactive leaf. Vision lite wherever applicable should be provided as per manufactures recommendation with a clip-on arrangement. The vision lite wherever applicable should be 5 or 6mm clear toughened glass as per manufactures recommendation with a clip on minimum 50 microns of approved color powder coat finish.
c. Door frames and shutters to have all hardware preparation pre-punched at the factory for flush fixing of hardware at site. Door shutters to be fixed on two frames with fire rated stainless steel double ball bearing butt hinges of dimensions 100 x 75 x 3mm. Double shutters shall have overlapping astragals applied to opposite faces of both shutters. Inactive shutters to be provided with concealed flush bolts of size 250x10mm long along with dust proof socket of approved Make or as approved by engineer in charge. d. The rate shall include the cost and conveyances of all materials, Fasteners, labor charges, lead, lift and necessary hardware like • SS ball bearing hinges of size 100x75x3mm. Minimum 03Nos for 2100mm height. In each panel, • Hydraulic door closer (1 No per each panel). • Door stopper (1 No per each panel) • Mortise sash lock with SS liver handles (1 set for each panel) side key operation • Concealed flush bolt of size 250mmx10mm with dust proof socket are required for double door leaf. complete as directed by the engineer - in- charge at all levels. All SS fixtures shall be of 304 Grade unless otherwise mentioned. All hardware’s shall be provided GEZE brand or equivalent fittings e. Supplying and fixing non fire rated steel door with clear vision panel of size 200x300mm.
Providing and fixing of standard duty hollow metal doors confirming to IS 16074 & IS 4351 made of pressed galvanized steel confirming to IS: 277 with the following specification: Doors shall be with vision glass as a part of complete assembly. Colour of the door unit shall be RAL 7040. f. Door frame shall be single rebate ground profile of size 120 x 60mm made out of minimum 1.15mm (18 gauge) thick galvanized steel sheet. Frames shall be mitered only. Frames shall be field assembled with self-tabs. Bolted & butted joints are not acceptable. All provision should be mortised, drilled and trapped for receiving approximate hardware. Frames should be provided with back plate bracket and anchor fasteners for installation on a finished plastered masonry wall opening. g. Door leaf shall be 46mm thick fully flush double skin door, with or without vision lite. Door leaf shall be manufactured from minimum 0.8mm (22gauge) thick galvanized steel sheet. The internal construction of the door should be rigid reinforcement pads for receiving appropriate hardware of approved make. The infill material shall be Rockwool or resin bonded honeycomb core. The edge should be interlocked with a bending radius of 1.4mm. For pair of doors integrated astragals has to be provided on the meeting stile for both active and inactive leaf. Vision lite wherever applicable should be provided as per manufactures recommendation with a clip-on arrangement. The vision lite wherever applicable should be 5 or 6mm clear toughened glass as per manufactures recommendation with a clip on minimum 50 microns of approved color powder coat finish.
h. Door frames and shutters to have all hardware preparation pre-punched at the factory for flush fixing of hardware at site. Door shutters to be fixed on two frames with fire rated stainless steel double ball bearing butt hinges of dimensions 100 x 75 x 3mm. Double shutters shall have overlapping astragals applied to opposite faces of both shutters. Inactive shutters to be provided with concealed flush bolts of size 250x10mm long along with dust proof socket of approved Make or as approved by engineer in charge. i. The rate shall include the cost and conveyances of all materials, Fasteners, labor charges, lead, lift and necessary hardware like • SS ball bearing hinges of size 100x75x3mm. Minimum 03Nos for 2100mm height. In each panel, • Hydraulic door closer (1 No per each panel). • Door stopper (1 No per each panel) • Mortise sash lock with Panic Bar key operation • Concealed flush bolt of size 250mmx10mm with dust proof socket are required for double door leaf. complete as directed by the engineer - in- charge at all levels. All SS fixtures shall be of 304 Grade unless otherwise mentioned. All hardware’s shall be provided GEZE brand or equivalent fittings j. Supplying and fixing non fire rated steel door with clear vision panel of size 200x300mm.
Supply and fixing of junction box cover of various sizes with SS 304 grade and 2mm thick Stainless steel plate of suitable sizes to properly cover the openings of junction boxes.The SS plate shall be satin finish and edges of the plate shall be neatly cut & polished to avoid the sharpness of edges. The four side size of the SS plate shall be added with a minimum of 50mm overlap over the existing tile to have a proper coverin for the juncition box opening and to fix the SS plate on the existing flooring tile with counter sunk screws of suitable size and length.Special care shall be taken by the contractor to avoid any damages to the existing finished floor tile while fixing the SS plate.Cut out in rectangular shape shall be provided for SS plate under the counters to pull out the cables wherever required as per the actual requirement at site. The rate should be including all material,labour,transporation etc complete and shall be fixed as per the directions of Engineer in charge.Payment shall be as per the actual area of SS plate measured at site. A reference drawing is attached herewith.
SS cover
Supply and fixing of cable tray cover with 1.2 mm thick G I sheet cover the existing G.I cable tray of width 150mm and 50mm bend vertically on both side and fixed with G.I Screws at suitable proper intervals to hold the cable tray cover. The rate should be including all material,labour,transporation etc complete and shall be fixed as per the directions of Engineer in charge. Payment shall be made as per the actual running meter of G.I cable tray cover measured at site.
GI vertical cable tray cover 150x50
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .