Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.3 LAccepted-AOC 10 MAKHAN LAL SADHUKHAN LANE PO PS BARRACKPORE KOLKATA 700120 W B | KOLKATA | NORTH 24 PARGANAS | WEST BENGAL | 700120 | L1 | Accepted-AOC Being L1 and reasonable | |
| 2 | L2₹32.2 L+₹70,694 (2.24%)Rejected-Finance 160 PREM NAGAR BAREILLY | L2 | Rejected-Finance Being other than L1 | |
| 3 | L3₹41.2 L+₹9.7 L (30.8%)Rejected-Finance SHOP NO 10 ASHRAM MANDIR NAKATIA P O P A C SHAHJAHANPUR ROAD BAREILLY 243001 | BAREILLY | BAREILLY | UTTAR PRADESH | 243001 | L3 | Rejected-Finance Being other than L1 |
Tender Value
₹47.8 L
EMD Value
₹96,000
Closing Date
21 Nov 2024, 6:00 pmClosed
GE Pithoragarh
GE Pithoragarh Post Bharkatia Pithoragarh ( UK)PIN-262520
PROVN OF OPEN TRAINING SHED, ADDN/ALTN TO BLDG NO T-13, SPECIAL REPAIR TO BLDG NO T-19 AND AND PROVN OF 02 NOS COVERED SHED FOR BATHING CUM DHOBI GHAT AT MIL STN BANBASA UNDER GE PITHORAGARH
2024_MES_681018_1
8649/PGH/E8
Open Tender
Civil Works
Item Rate
240 days
Banbasa
Class D Category a(I)
6 documents required · 6 mandatory
₹500
GE Pithoragarh
₹96,000
Yes
8 Jan 2025
24 Oct 2024
23 Nov 2024
24 Oct 2024
21 Nov 2024
7 Nov 2024
Amount
DESCRIPTION OF ITEMS
Surface excavation n.exc (not exceeding) 30cm deep and averaging 15cm deep and getting out in soft/loose soil complete all as specified and directed.
Excavating in trenches, not exc 1.5 m wide and not exc 1.5 m in depth, for foundation etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft/loose soil complete all as specified and directed.
Removing excavated soils n exc. 50m and depositing where directed at a level n exc. 1.5m above the starting point complete all as specified and directed.
M & L for hardcore of gauge n exc. 63mm, deposited, spread and levelled in layers not exc.15cm thick, watered and rammed to a true surface complete all as specified and directed.
M & L for 75mm thick PCC 1:4:8, type D-2 (using 40 mm graded stone aggregate) as in sub base complete all as specified and directed.
M & L for PCC 1:4:8 type-D2 (using 40mm graded stone aggregate) in foundation, filling and mass concrete complete all as specified and directed.
M & L for brickwork with old sized sub-class ‘B’ burnt clay bricks, straight or curved on plan exc 6m mean radius built in CM(1:6) complete all as specified and directed.
M & L for 10mm thick cement plaster in CM (1:6) on other than fair surfaces of brick walls and finishing the surfaces fair and even complete all as specified and directed.
M & L for 15mm thick cement plastering in CM (1:4) on fair surfaces of brick walls and finishing the surface fair and even complete all as specified and directed.
M & L for preparation of new wall surfaces and applying two coats of distemper oil emulsion over a layer of 1mm thick wall care putty complete all as specified and directed.
M & L for preparing new surfaces of walls and applying two coats of cement base paint over a coat of alkali resistant primer complete all as specified and directed.
M & L for RCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
M & L for RCC 1:2:4 type B-0 (using 12.5 mm graded stone aggregate) as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and directed.
M & L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping), work in rough finished flat surfaces of concrete complete all as specified and as directed.
M & L for formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc., work in rough finished surfaces of concrete complete all as specified and as directed.
M & L for formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide, work in rough finished surfaces of concrete complete all as specified and as directed.
M & L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required including cranking, bending spirally for hooping for columns and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
M & L for mild steel TMT bars 8mm dia, cut to length, bent to shape required including cranking, bending spirally for hooping for columns and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
M & L for 40mm thick damp proof course in cement concrete (1:2:4) type B-0 (using 12.5mm graded stone aggregate) to horizontal or vertical surfaces including necessary formwork and using water proofing compound as per manufacturer's instructions complete all as specified and directed (WPC shall be measured and paid separately).
Supply only liquid water proofing compound.
S & F of 110mm bore PVC (SWR) pipes, single socketed, in any length with rubber ring joints, fixed to walls complete all as specified.
S & F of 110mm bore PVC (SWR) pipes, single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified.
S & F of PVC (SWR) bends 110mm dia complete all as specified and directed.
S & F PVC (SWR) 110 mm junction (Single T) equal or unequal 110mm complete all as specified and directed.
S & F PVC (SWR) vents cowl 110m dia complete all as specified and directed.
S & F PVC (SWR) 75mm floor trap, plain with gratting, including jointing with solvent cement complete all as specified and directed.
S & F of rolled mild steel sections as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. conforming to Gde Fe-410 W (Gde- E- 250) quality-A complete all as specified and as directed.
S & F of rolled mild steel works as in bands, straps, supports or stays for rainwater, hook and pintle hinges, clamps, hold fasts, wall ties, hooks for hanging fans, gusset plates, plain angle cleats for securing purlins to wood trusses or rafters and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and directed.
M & L for preparation of new steel surfaces of any description, over 10cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
S & F of pre-painted galvalume aluminium zinc coating GI base corrugated steel sheet 0.50 mm thick trapezoidal pattern of any colour having tensile strength of 550 MPa as in roof covering, fixed with self tapping screws complete all as specified and directed.
S & F of pre-painted galvalume aluminium zinc coating GI base plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in ridge of roof covering / cladding to wall, fixed with self tapping screws/L-type or J-type or cranked hook bolts complete all as specified and directed.
Providing & fixing false ceiling at all heights with semi perforated 12mm thick micro tegular edged GRG (Glass Fibre Reinforced Gypsum) false ceiling tiles of Size 595 x 595 mm of approved texture, design and patterns having moisture content less than 2%, humidity resistance of 99%, NRC 0.50 to 0.75 as per IS 8225:1987, Noncombustible as per BS 476 (part 4 )-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on interlocking metal T-Grid of hot dipped galvanized iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main- T runners of size 15 x 32 mm of length 3000mm,cross-T of size 15x 32mm of length 1200mm and secondary intermediate cross-T of size 15 x 32 mm of length 600mm to form grid module of size 600x 600mm, suspended from ceiling using galvanized mild steel items (galvanizing @ 80 grams per sqm) i.e 50mm long, 8mm outer diameter M-6 dash fasteners, 6mm dia fully threaded hanger rod upto 1000mm length and Lshape level adjuster of size 85x25x2mm. Galvanised iron perimeter wall angle of size 24x 24x0.40mm of length 3000 mm to be fixed on periphery wall I partition with the help of plastic rawl plugs at 450 mm center to center and 40mm long dry wall wood screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-charge.
M & L for Vitrified tiles (light shade) 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in coloured cement to match over and incl 15mm thick screed bed in cm 1:6 complete all as specified and as directed by Engineer-in-Charge.
M & L for Vitrified tiles (light shade) 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, as in vertical surface etc set and jointed in neat cement slurry and pointed in coloured cement to match over and including 10mm thick rendering in CM 1:4 complete all as specified and as directed by Engineer-in-Charge.
M & L for joint free non-skid ceramic coloured floor tiles exc 0.11sqm but not exc. 0.18sqm as in floors set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match the shade over and including 15mm thick screed bed in CM(1:6) complete all as specified and directed.
M & L for glazed ceramic coloured wall tiles 450X300mm and 7mm thick including bedded and jointed in neat cement slurry and pointed with white cement with pigment to match the shade of tile over 10 mm thick rendering in CM(1:4) complete all as specified and directed.
S & F of vitreous china wash hand basin white flat back of size 550mm x 400mm including cutting for and pinning ends of brackets including 32mm bore PTMT waste coupling (half or full threaded) and PVC waste pipe 32mm dia and 15mm bore PVC connection 450mm long with brass union and jam nuts on both sides and fixed on a pair of MS cantilever bracket of appropriate size complete all as specified and directed.
S & F of 15mm bore fancy type pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and directed.
S & F of towel rail 600mm long of PTMT fixed with and including chromium plated brass screws and wooden/plastic cleats (Minimum weight 190gms) complete all as specified and directed.
S & F of vitreous china squatting pan of Orissa pattern, size 580x440 mm size white with integral foot rest with Cast Iron `P' or `S' trap, front or back inlet and including connection to trap and to flushing pipe, anti-syphonage pipe etc., including trap set in and including cement concrete bedding including providing new flush pipe complete all as specified and directed.
S & F of vitreous china wash down water closet pan (EWC pedastal pattern) white, with Cast Iron `P' or `S' trap, front or back inlet and including connection to trap and to flushing pipe, anti-syphonage pipe etc., including trap set in and including cement concrete bedding and including mild steel chromium plated or aluminised hinging device seat cover (white) and including supplying and fixing stainless steel jet spray complete all as specified and directed.
S & F of PVC low level flushing cistern 10 Litres capacity with all internal accessories and fixed to wall including 450mm long PVC connection pipe 15mm bore with brass union and jam nuts on both sides, PVC flush pipe 32mm dia fixed properly to inlet of WC complete all as specified and directed.
S & F of 15mm bore bib taps fancy type, cast copper alloy chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe all as specified or as directed.
S & F of 15mm bore angular stop cock fancy type, cast copper alloy chromium plated screwed down, high pressure, with crutch or butterfly handle, screwed for iron pipe or for unions and fixed complete all as specified and directed.
S & F of 15mm bore concealed stop cock fancy type, cast copper alloy chromium plated long shank and cup, screwed down, screwed for iron pipe of 15mm bore all as specified or as directed.
S & F of brass chromium plated shower rose of 125mm size with or without swivel joints including fixing to steel pipe or union all as specified and directed.
S & F of vitreous china bowl urinal flat back, size of 465 x 355 x 265 mm white (minimum), with grating and union for discharge pipe complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60 mm long brass screws, pointing around urinal back in cement mortar 1:3 including PTMT spreader, PTMT waste coupling, PVC waste pipe complete all as specified and directed.
S & F GI tubing medium grade, galvanised with all fittings and fixed complete to wall and ceiling or laid in floors bore of tube 15mm all as specified and directed.
S & F GI tubing medium grade, galvanised with all fittings and fixed complete to wall and ceiling or laid in floors bore of tube 20mm all as specified and directed.
Supplying, hoisting and fixing of rotational moulded PVC water storage tank, 1000 litres capacity conforming to IS-12701 (1996) cylindrical vertical type triple-layered with closed top including 20mm bore PVC float valve and necessary fittings for inlet, outlet and wash out holes complete all as specified and as directed.
Supplying, hoisting and fixing of rotational moulded PVC water storage tank, 500 litres capacity conforming to IS-12701 (1996) cylindrical vertical type triple-layered with closed top including 20mm bore PVC float valve and necessary fittings for inlet, outlet and wash out holes complete all as specified and as directed.
Supply and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30mm thickness. The laminte shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame, complete as specified by the manufacturer and as per directions of Engineer-in-charge.
Supply and fixing to existing door frames 30 mm thick Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames, complete as specified by the manufacturer and as per directions of Engineer- in-charge.
S & F 100mm long medium weight, cold rolled stainless steel butt hinges with fixed with stainless steel screws complete all as specified and directed.
S & F aluminium handle, cast type anodised size of handle 125mm ISI marked complete all as specified and directed.
S & F aluminium anodised, barrel tower bolts of extruded section length of bolt 150 mm ISI marked complete all as specified and directed.
M & L for framed work as in grills, gratings etc. with ends of bars shouldered and / or rivetted, or forged into spikes; framed guard bars; barred iron door, railings and similar work conforming to Fe 290-0 or Fe 310-0, complete all as specified and directed.
S & F of powder coated aluminium frame for doors, windows, ventilators with one or more rebates or three track section for windows including joining cleat for fixing etc. complete all as specified by Engineer-in-Charge.
S & F of powder coated aluminium window and ventilator shutters, fixed type/sliding type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, powder coated aluminium snap beading, lock, screws etc. complete all as specified and directed by Engineer-in-Charge.
S & F of powder coated aluminium door shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, powder coated aluminium snap beading screws etc. complete all as specified complete all as specified and directed by Engineer-in-Charge.
S & F of sheet glass 4.80mm thick ordinary quality with oil putty or rubber and beading complete all as specified and directed
S & F of 25mm chromium plated curtain rod of approved quality including fixing with brackets, knobs, screws etc complete all as specified and directed.
S & F of sheet glass (frosted on one side) of 4.80mm thick ordinary quality glass and glazing with oil putty in square n exec 0.5 Sqm in each pane complete all as specified and directed.
Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and directed.
M & L for 75mm thick cement concrete type-C1 (1:3:6) using 20mm graded aggregate as in path, plinth protection finished surface even and smooth with out using extra cement all as specified and directed.
M & L for PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in roof kerbs, coping, benching etc including weathering slightly rounded or chamfered angles and throating, complete all as specified and directed.
Excavation in post holes in soft/loose soil (or similar holes) each not exc 0.5 cum getting out returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm all as specified and directed.
S & F of rolled mild steel sections as in main and cross beams, hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors, fixed with angle cleats or other connecting plates conforming to Gde Fe-410 W (Gde- E- 250) quality-A complete all as specified and as directed.
M & L rendering in CM 1:4 on walls 15mm thick on fair faces of brick work with water proofing compound finished the surface even and smooth with out using extra cement complete all as specified and directed.
M & L for preparing the new surfaces of walls and applying three coats of white wash on complete all as specified and directed.
S & F of exterior grade heavy duty coloured floor tiles of size 300mmx300mm/400mmx400mm, 10 to 12mm thick over and including 15mm thick screed in CM 1:6 set and jointed in neat cement slurry and pointed in white cement and pigment to match the shade complete all as specified and directed.
M & L for glazed ceramic coloured wall tiles 450X300mm and 7mm thick including bedded and jointed in neat cement slurry and pointed with white cement with pigment to match the shade of tile over 10 mm thick rendering in CM(1:4) complete all as specified and directed.
M & L for sand filling under floors or in foundations including watering and consolidation complete all as specified and directed.
M & L for 75mm thick PCC 1:4:8, type D-2 (using 40 mm graded stone aggregate) as in sub base complete all as specified and directed.
M & L for machine cut Kota stone slab 20-25mm thick as in flooring over and including 15 mm thick screed bed in CM (1:6) laid and bedded jointed in cement slurry mixed with pigment to match to shade of the slab incuding grinding, mirror polishing complete all as specified and directed.
S & F of Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 complete all as specified and as directed.
Dismantling of AC corrugated, semi-corrugated sheets in roof coverings & ridges.
Dismantling timber scantling 40 sq cm and over in framed work in any position.
S & F of second class hard wood timber scantling clean sawn framed and fixed in any position and direction complete all as specified and directed.
S & F of rolled mild steel sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides fixed with angle cleats or other connecting plates conforming to Gde Fe-410 W complete all as specified and as directed.
Dismantling of wall and ceiling boards (fibre, pulp, insulation etc) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as directed.
S & F of suspended ceiling system of grid/section of size 600x600mm comprising of interlocking GI powder coated main T-runners of size 24x38x0.33mm thick of length 3000mm, cross-T of size 24X32X0.33mm thick of length 1200mm and secondary intermediate cross-T of size 24X32X0.33mm thick of length 600mm and perimeter wall angle of size 24x24x0.40mm thick of length 3000mm to be fixed on periphery wall/partition with the help of plastic rawl plugs @ 450mm center to center and 40mm long dry wall S.S. screws with and including 4 mm thick E-board false ceiling tiles of size 595x595mm of approved texture, design and pattern to be placed in the grid system duly suspended with 6 mm dia GI wire hangers fixed with steel dash fasteners or from purlin of the roof with clip complete all as specified and directed.
Demolition of brick work /stone work built in cement mortar all as specified and directed.
Dismantling floor hearth, wall tiling including cement mortar bedding, backing complete all as specified and directed.
Demolition of cement concrete unreinforced in ground floor & paving n.exc 15cm thickness and removal of debris from site all as specified and directed.
Taking down cement plaster of any description in any position incl raking out joints making for key, scrubbing down with water etc and removal of debris from site all as specified and directed.
M & L for preparation of old plastered surfaces of walls by complete removal of existing treatment by brooming down or steel wire brushing, moulds, moss and efflorescent salts etc and applying two coats of oil emulsion distemper of white or tinted, over & including a layer of wall care putty (average thickness 1mm) finished smooth, complete all as specified and directed.
Removing old lime wash (if any), hacking for key, raking out joints of old brick work or stone work built in cement mortar; not previously plastered; and scrubbing down with water etc. to receive plaster and removal of debris from site all as specified and directed.
Taking down chowkhats or frames with shutter(without taking off shutter from the frame) area not exc. 1.5 sqm and making the surface of brick wall good plastering, around the opening complete all as specified and directed.
Taking down chowkhats of any description without taking of shutter from the frame exceeding 1.5 sqm but not exc. 4.0 sqm each and making the surface of brick wall good plastering, around the opening complete all as specified and directed.
S & F of Stainless Steel wire cloth of 0.36mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete all as specified and direceted.
S & F in repair 15mm bore brass CP wash hand basin mixer for mixing hot & cold water screwed down for iron pipe and fixed complete all as specified and directed.
S & F in repairs of 15mm dia PVC connection with PTMT nuts of length 450mm complete all as specified.
S & F in repairs, 100mm dia, cast iron floor trap with and including suitable size chromium plated stainless steel grating with or without waste hole including jointing to waste pipe, fixed to cement concrete type B1 1:2:4, complete all as specified and directed.
Taking down rainwater pipes (any size or pattern), including all fittings heads, shoes, bends, swan-necks etc., including cleaning or refixing or removal to Store (measured over all as fixed along the centre line over fittings and accessories)
Taking down GI pipes and connection including cleaning for refixing or removal to store of 15mm bore all as directed.
Demolition of reinforced cement concrete as in RCC chajja, chimney, beams, slab, shelves etc. by chiseling and cutting the reinforcement including removing the rubbish / debris to a distance as directed by Engr-in-charge, complete all as specified and directed
M&L for septic Tank, excavation in any type of soil,foundation in PCC 1:2:4 type B-2, brick work in CM 1:4, including RCC 1:2:4 Ttype B-1 partition wall and RCC slab covers including RCC precast manhole cover having 6 mm plate embedded all round/fiber reinforced cover with angle iron frame, vent shaft and sludge chamber etc complete for 10 users complete all as specified and directed and shown on Drawing No TD-217 Sheet 1/7 to 7/7.
M&L for construction of Soakage wells, excavation in any type of soil, foundation in PCC 1:2:6 , walls of honey combed massonry with top ring of M25 concrete including intercepting chamber and screen chamber made of bricks masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 2.40 m dia x 3.00 m of effective depth 3 mtr complete all as specified and directed and shown on Drawing No TD-309 Sheet 1/4 to 4/4.
Taking down copper /aluminium point wiring (light, fan, bell,socket or power) complete including fixture and fittings such as switches , ceiling roses , pendent , regulators, sockets, light fitting etc. Removing materials to store for keeping in safe custody or for taking credits and making good distrubed surfaces of walls, floors etc complete all as specified and directed at site.
Taking down old/unserviceable distribution board by disconnection of electric connection carefully SPN DBs/TPN DBs/ Main Switch including old unserviceable MCCBs/ MCBs, Isolators, etc and making good to disturbed surface complete all as specified and directed.
Taking down ceiling fan/ exhaust fan of any sweep after disconnecting all necessary electrical connections from ceiling rose to fan, fan blades and deposit to MES store yard complete all as specified and as directed.
M&L for point wiring with 1.5 Sq mm single core PVC insulated unsheathed copper FRLSH multi stranded conductor cable in and including Concealed PVC conduit of size 20/25mm ISI marked inclusive of tees ,bend ,elbows etc upto and including sunk in anodized pressed steel box for housing switch socket etc with white laminated 3 mm thick hylam sheet cover ISI marked of suitable size complete including PVC insulated multi stranded copper conductor 1.5 Sq mm FRLSH cable as earth wire to common earth dolly for connection to ceiling rose to earth terminal including cutting, chasses and making good disturbed surface to match with existing finish with plaster complete all as specified and directed by Engr-in-charge for following :- (a) One light point controlled by one, one way switch 5 Amps
(b) One fan point controlled by one, one way switch 5 Amps and regulator
(c) One 3 pin 5 Amps switch socket outlet point controlled by one switch on the same board.
(d) One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent boad.
Description all as per item No 4 here in before but using 2.5 sq mm single core copper conductor cable of multistranded flame retardant PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket cobmination point including necessary running of 2.5 sq mm copper conductor flame retardant PVC wire as earth continuity conductor along with wiring and connecting to the common eath dolly.
S & F for Switch Piano type single pole 5 amp, 230 Volts complete all as specified and directed at site.
S & F for Switch Piano type single pole 15 amp, 230 Volts complete all as specified and directed at site.
S & F for socket outlet 2 in 1 , 5 pin, 5 amp, 230 Volts complete all as specified and directed at site.
S & F for socket outlet 2 in 1 , 5 pin, 15 amp, 230 Volts complete all as specified and directed at site.
S & F for Ceiling rose, surface Bakelite with 3 terminals, ISI marked for batten fitting complete all as specified
S & F for stepped type electronic fan regulator flushType complete all as specified and directed at site.
S&F D Box with MCB protected Socket with plug 20 A with sheet steel Enclosure suitable for AC/Geyser & industrial use (without wire) as specification IS 13032 & IS 8623 Cat part No 20 A MCB DBOXXCOMBO of make Havells or its equivelent.
S&F LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed.
S & F for sheet metal enclosure MCB DB SPN 12 way with 200 Amps rated bus bar 240 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed.
S & F for sheet metal enclosure MCB DB SPN 8 way with 200 Amps rated bus bar 240 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed.
S & F for MCB Single pole and neutral rated capacity 40 Amps, 240 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed.
S & F for MCB Single pole rated capacity 5 to 32 Amps, 240 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed.
Fixing only for refixing the celing fan with copper conductor cable of size 23/ 0.193 from ceiling rose to fan terminal complete all as specified and as directed.
Supply and fixing LED lights fitting 1x 18W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete.
Supply and fixing LED Bldg sec light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.
Supply and fixing LED light fitting mirror type with high output diffuser 2 feet, 10 watt 220 Volt AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Copper binding, Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC)
Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250 mm all as specified and directed.
Supply and fix electric water heater, storage type steel body with copper inner tank and Heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety Valve, thermostate, NRV, connection piece etc complete all as specified and as directed.
S & F for lamp holder , PVC / Polycarbonate type with back plate suitabl for batten/ slanting fittings complete all as specified and directed.
S & F for Highly efficient LED Bulbs, 10 W, used as a ready replacement for existing GLS/CFL direct fit lamp,in B-22 cap of make Bajaj, Havells, HPL complete all as specified and directed
Taking down existing old Extg unserviceable LT UG/ service cable of any description and size complete all as specified and directed.
M&L for providing dry sand as in cushioning to underground cable including punning down of sand in layers as specified and directed.
M&L for brick protection cover of UG cable by using old size sub class 'B''common burnt clay building bricks, laid dry and flat abutting each other with width equal to length of the brick and gap between adjacent brick n.exc 10 mm complete all as specified and directed.
S & F XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 35 sq. mm 2 core core all as specified and directed.
S & F XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 25 sq. mm 2 core core all as specified and directed.
S & F XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 16 sq. mm 2 core core all as specified and directed.
S&F GI Pipe 40 mm dia light grade for protection of cable.
M&L earthing complete with galvanized steel earth plate electrode 60cm x 60cm x6.0 mm thick, burried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level, connected to galvanized earth lead wire 4.0mm dia Protedcted by light GI Pipe 20 mm dia and 15 dia med grade for watering pipe and connected by means of bolts, nuts, check nuts and washers of galvanized iron or steel, iron funnel,Iron pit cover and chamber all as shown in electrical plate No. 3 connected to earthing test point including testing on completion complete all as specified and directed.
Supply and laying for galvanised iron tubing medium grade with and including all fittings such as bends, elbows, tees, short pieces, union etc in trenches/wall/under road etc complete all as specified and as directed of following sizes :-. (a) 15 mm dia
Supply and laying for galvanised iron tubing medium grade with and including all fittings such as bends, elbows, tees, short pieces, union etc in trenches/wall/under road etc complete all as specified and as directed of following sizes :-. (b) 20 mm dia
Supply and laying for galvanised iron tubing medium grade with and including all fittings such as bends, elbows, tees, short pieces, union etc in trenches/wall/under road etc complete all as specified and as directed of following sizes :-. (c) 25 mm dia
M&L for fixing of Straight plain brass ferrules (or connecting screws) screwed both ends and fixed of bore dia 20 mm all as specified and directed.
S&F in replacement gun metal gate valve with iron wheel head and screwed both ends for GI pipe all as specified and directed of size 25 mm dia
S&F in replacement gun metal gate valve with iron wheel head and screwed both ends for GI pipe all as specified and directed of size 20 mm dia
Builders Harpal (BID ID -3165573)
NOORI ELECTRIC ENGINEERING WORKS (BID ID -3163809)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .