Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical MADEENA MALL MANKADA ROAD MAKKARAPARAMBA MALAPPURAM 676 507 | MALAPPURAM | MALAPPURAM | KERALA | 676507 | Admitted-Fee/PreQual/Technical |
| 2 | Admitted-Fee/PreQual/Technical NADULANGADI POOKKAYIL PO MALAPPURAM 676107 | MALAPPURAM | MALAPPURAM | KERALA | 676107 | Admitted-Fee/PreQual/Technical |
Tender Value
₹8.0 Cr
EMD Value
₹2 L
Closing Date
8 Dec 2025, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SUPERINTENDING ENGINEER
OFFICE OF THE SUPERINTENDING ENGINEER,KWA, PH CIRCLE, THANA, KANNUR
AMRUT-2.0 - Kannur Corporation -Supply and Erection of Pump sets, Laying of MS Pumping main, Supply and Erection of Transformer-General Civil Work
2025_KWA_821241_1
14/2025-26/PHC/KNR
Open Tender
Civil Works - Water Works
Item Rate
240 days
Velliyambra
Please refer Tender documents
10 documents required · 10 mandatory
₹13,010
₹2 L
KWA, PH CIRCLE, THANA, KANNUR
30 Jan 2026
27 Nov 2025
9 Dec 2025
27 Nov 2025
8 Dec 2025
1 Dec 2025
1 Dec 2025
Work Name:AMRUT-2.0 - Kannur Corporation -Supply and Erection of Pump sets, Laying of MS Pumping main, Supply and Erection of Transformer-General Civil Work
all fabrication charges, charges of painting the steel work with two or more coat deluxe multi surface paint to give an even shade over an under-coat of primer etc., complete: For pipes fabricated with 10mm thick M.S. plates.Ü100.37.23.3:Cutting 750mm (I.D.) M.S. pipes for making bends and other specials by gas cutting including cost of gas, all labour and hire charges of tools etc., complete: For pipes fabricated with 10mm thick M.S. plates.þ100.37.23.4:Welding 750mm (I.D.) M.S. pipes for making bends and other specials by gas/electric welding machine including cost of gas and welding rods, all labour and hire charges of tools etc., complete: For pipes fabricated with 10mm thick M.S. plates.Ë100.37.23.5:Grinding cut and weld edges of 750mm (I.D.) M.S. pipes during fabrication work including all labour and hire charges of tools etc., complete: For pipes fabricated with 10mm thick M.S. plates.100.35.12:Testing 750mm DI/CI pipeline with potable water to the required test pressure. 750 mm dia Observed Data derived from item no.1031 of PHED DATAQOD96818/2025-2026:Labour for cutting MS pipe with steel saw: 750mm diameter pipe.NAppendix C: SUPPLYING AND FIXING 3 nos 600 HP VT PUMPSET AND ITS ALLIED WORKSSOD65740/2025-2026:(600 HP VT PUMP SET) Supply, erection, testing and commissioning of KWA pre-qualified reputed make Vertical Turbine type pump set with Bronze/SS impeller, SS shaft and CI pump casing with suitable type base plate with coupling guard foundation bolts & nuts etc. complete suitable for coupling the pump and motor above the base plate etc. complete including providing suitable concrete foundation including cost of cement, sand and metal etc. complete, including supply, erection, testing and commissioning of KWA approved suitable panel board , cabling work, earthing, capacitors, valves and suction and delivery pipe connections etc. complete including two year maintenance cost of all the components related to pump sets. Duty condition : Discharge : 483.09 lps,,Total head - 125.12 m, Minimum efficiency 70% (Minimum 600 HP) HP (Horse power)ÐOD65429/2025-2026:OD based on MR 12292 and MR 12291: Supply of Vertical TEFC Squirrel cage Induction Motor- 4 Pole -450 kW ( 600 HP *0.746 = 447 kW) for 600 HP Pump set/motor (Avg rate for40 kW as 81200 )sOD65430/2025-2026:Supplying additional length including erection, testing and commissioning of KWA approved 300 Sq mm 3 core,3.3 KV XLPE Aluminium cable for making connection from transformer to main power panel boards and from each main power panel to consecutive motor starters with proper earthing including cost, conveyance charge and all labour charges etc complete.OD66944/2025-2026:OD based on Approved Est. No.15232/2022-Supply, installation, testing and commissioning of Soft starter, Panel capable of operating the above mentioned motor of VT pumpset having a protection level of IP 40 or more with integrated bypass contractor in the panel and motor protection relay having parameters as per IE Rules with a power control MCCB and line power contractor etc. as per the site requirement, latest Indian Electric code specification and direction of the Engineer in charge. The starting current shall be 2.5-3.5 times the normal full load current of motor. The sot starter shall be floor mounting type and having an insulation level of 1100 V (for 440 V supply) and 7.6 KV for (3.3 KV supply) and 14.2 KV (for 6.6 KV supply ).The standard is to be I.E.C 60947-4-2 with all fittings like Ammeter, Voltmeter and phase indicators,space heaters etc. complete.SOD65428/2025-2026:Extended Warranty : Charges towards for providing extended warranty for the proposed installation of 600 HP - VT type pump sets, Vertical TEFC Squirrel cage Motor 4 pole 450 kW, Soft Starter and it?s all components in Kannur WSS Intake well cum pump house at Veliyambra (5% of whole cost of pump sets, motor and starter)L.S7Lifting and Erection of Departmental 600 HP VT Pump setÍOD92724/2025-2026:Lifting the 600 HP VT pump set from the well and dismantling pump top head, and taking out same, cutting, chipping rusted bolt nut from column pipe flange and dismantling line shaft assembly, spider set one by one and dismantling column pipe and lifting 600 HP VT pump, taking, moving the same to outside of pump house and stacked safely nearby generator room etc. including all cost, conveyance charge and all labour charges etc complete.COD92727/2025-2026:Erection of 600 HP Existing Departmental pump set,APPENDIX D: SUPPLY AND FIXING SURGE ARRESTER.OD65432/2025-2026:Approved OD based on EST NO:2019/2020 Item no: 61 . Sl no 29 -(Od160197/2019_2020 ): Conducting Surge Analysis of the Pumping System and Supplying, erection, testing and commissioning of suitable type Surge Protection System at appropriate locations as identified having Hydraulic/ Solenoid Control Valves with back up battery capable of operating in on line and offline condition for the Clear Water Pumping Main -750 mm DI K9 pipe line- Surge protection system for 750 mm Raw Water Pumping main -(In between Booster station and WTP) setMOD65433/2025-2026:Supply and installation of surge water release valves of approved design and approved manufactures at suitable locations as per the surge analysis to release water from pumping main to reduce surge pressure incase of failure of pressure release valves and zero velocity valves during sudden failure of power supplyNSupply,erection, testing and commissioning of 1750 KVA, 11KV/3.3KV TransformereOD67506/2025-2026: 11KV/3.3KV, 1750KVA Transformer. Supply,erection, testing and commissioning of 1750 KVA, 11KV/3.3KV. 3phase, 50Hz. ONAN cooled , indoor type copper wound distribution transformers, with HV and LV side cable end box arrangements, on load tap changer with 17 tap positions having +5% to -15% variations in1.25% steps with RTCC panel including first filling of oil etc. complete with all fittings as per IS 2026 & IS1180(level2) and Kerala Electrical Inspectorate standards. Armoured multi core 2.5 Sqmm copper control cables shall be used for all external & internal interconnections . The cost of control cables both internal and external shall be included in the cost of Transformer. i) Supply of Materials(for 1250 KVA transformfer Rs.32,36,500/- & for 1500 KVA transformer Rs.33,83,555/- there for rate change @ Rs. 1,47,055/- for 250KVAi2.9.1:Excavation work by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m.Ordinary rockÅ50.6.7.1:Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for foundation and basement including all cost of materials, labour charges etc.Ê5.3:Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources).¨5.22.2:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelHard drawn steel wire5.9.16.1:Centering and shuttering including strutting, etc. and removal of form for: Edges of slabs and breaks in floors and wallsUnder 20 cm wide\50.18.8.6.2:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 50 mm pipe 6 kgf/cm28OD67827/2025-2026:Supply and installation of exhaust fanû9.48.2:Providing and fixing
M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings/ wooden frames with rawl plugs screws etckgOD93593/2025-2026:Od based of Approved Est 15232/2022 11 KV Metering Unit-Supply,erection, testing and commissioning of out door type metering unit consisting of the following accessories:Current Transformer CT Ratio 100/5A Burden 15VA Accuracy Class 0.2S Potential Transformer PT ratio 11KV/110V Burden -100VA. Accuracy Class 0.2 The rate shall include the cost of testing the equipment at KSEB and all other incidental expences. The CT ratio should be fixed only after obtaining the power allocation from KSEB.MOD93598/2025-2026:Supply,erection, testing and commissioning of TOD meter with maximum demand in KVA suitable for the above out door metering set housed in a weather proof out door Kiosk with TTB and cable for connecting to the CTPT.The rate shall include the cost of testing the equipment at KSEB and all other incidental expences.Sets/OD93927/2025-2026: 11KV VCB Panel(Indoor) Supply, erection, testing and commissioning of 11KV, 630A, 350MVA, totally enclosed, single bus bar, floor mounting in metal clad, indoor extensible type flush mounted horizontal isolation and drawout type vacuum circuit breaker singler panel system suitable for installation in 3 phase , 3wire, 50Hz,AC,11kv, effectively earthed supply system,comprising of motorised and spring assisted, independent, trip free closing mechanism and all metering equipments, protective relays etc. complete as approved by Kerala Electrical Inspectorate and relevant standards. Armoured multi core 2.5 Sqmm copper control cables shall be used for all external & internal interconnections. The cost of control cables both internal and external shall be included in the cost of HT panel.OD93938/2025-2026:Supply, erection, testing and commissioning of 3.3KV, 400A, 75MVA, totally enclosed, single bus bar, floor mounting in metal clad, indoor extensible type flush mounted horizontal isolation and drawout type6 panel system comprising of 1nos Vacuum Circuit breakers as incomer and 3 nos,for motors,1 no Vacuum Circuit Breakers ( for APFC panel) as outgoings and 1 no as spare. The incomer switchgears, & amp outgoing switchgears should be of drawout type trip free VCBs suitable for installation in 3 phase , 3wire, 50Hz. AC, 3.3kv, effectively earthed supply system,comprising of motorised and spring assisted, independent, trip free closing mechanisum and all metering equipments, protective relays, etc. complete as approved by Kerala Electrical Inspectorate and relevant standards. Armoured multi core 2.5 Sqmm copper control cables shall be used for all external & amp internal interconnections. The cost of control cables both internal and external shall be included in the cost of 3.3KV panel. Cost of MaterialsïOD93952/2025-2026:Od based on approved estimate no. Est/15232/2022 3.3KV Off Load Isolators for VT Pumps. Supply, erection, testing and commissioning of 3.3KV, 400A, 75MVA, totally enclosed, single bus bar, floor mounting in metal clad, indoor extensible type flush mounted Off Load Isolator panel suitable for installation in 3 phase , 3wire, 50Hz. AC,3.3kv, effectively earthed supply system,comprising of spring assisted, independent, trip freeclosing mechanism etc. complete as approved by Kerala Electrical Inspectorate and relevant standards. Armoured 2.5 Sqmm copper control cable shall be used for all interconnections. The cost of control cables both internal and external shall be included in the cost of HT panel. Cost of MaterialsáOD93712/2025-2026:Od based on approved estimate no. Est/15232/2022 APFC Panel Supply, Installation, Testing and commissioning of 3.3KV, automatic/manual Power Factor Correction Panel suitable for maintaining the power factor above 0.97 for any combination of running of the 3 VT pump sets (at least one out of three standby always).The panel shall be fabricated out of 2mm CRCA Sheets Modular, compartmentalized, Free Standing, Floor Mounting, Front hinged doors for indoor use, removable bottom/top gland plates for incoming cables, dust and vrmin proof (IP: 42 protection) with low loss heavy duty 3.3 KV capacitors of reputed make, 3.3KV VCB/ contactors for swiching, Digital pf control relay, digital display for instantaneous power factor, capacitor in sevice indication, TP Aluminium Busbars, complete with busbar connection, internal wiring, name plates, painting etc. as per KEI standards. pf compensation for transformer reactive power also shall be included in this panel.íOD93715/2025-2026:Od based on approved estimate no. Est/15232/2022 Neutral Grounding Resistor. , supply erection,testing and commissioning of indoor type 3.3KV stainless steel make neutral grounding resistor in sheet steel enclosure with IP 23 degree protection with siutable neutral CT for REF protection. The cubicle shall be fabricated out of 3mm sheet steel and painted with anti –rust primer coating followed by two coats of paint of approved shade, as per standards. The resistance shall be of Kerala Electrical Inspectorate and relevant standards. Armoured 2.5 Sqmm copper control cable shall be used for all external interconnections. The cost of control cables both internal and external shall be included in the cost of NGR.ÍOD93605/2025-2026:Od Based on Approved Est No. Est/15232/2022 Power Distribution board (PDB) "Supply,erection, testing and commissioning of 8 way MCB distribution board comprising to the following. 63A 4 pole MCB 1 No. as incomer with 63A 100mA ELCB and 20A TP MCB-2Nos. & 20A SP MCB- 6 Nos each. as outgoings, With tinned copper busbars/cables, interconnection, housed in a suitable metal enclosure as per KEI standards fixed in open system."±OD93957/2025-2026:Od Based on Approved Est No. Est/15232/2022 Lighting Distribution board (LDB) "Supply,erection, testing and commissioning of MCB distribution board comprising to the following. 40A TPN 4 pole MCB 1 No. as incomer with 40A 30mA ELCB, 18 nos 6 AMPS SP MCB as outgoings, With tinned copper busbars/cables, interconnection, housed in a suitable metal enclosure as per KEI standards fixed in open system."zOD93786/2025-2026:Od based on approved estimate no. Est/15232/2022 Cabling Supply, laying, testing and commissioning of the following size PVC/XLPE insulated, sheathed armoured Aluminium conductor cable (1100 volts&3.3/11kv grade) clamped on wall/ceiling with clamps and saddle clips partly laid in cable tray/partly laid in trench. 1core 95Sq.mm.3.3kv, XLPE AL Cable.pOD93790/2025-2026:Od based on approved estimate no. Est/15232/2022 Supply, laying, testing and commissioning of the following size PVC/XLPE insulated, sheathed armoured Aluminium conductor cable (1100 volts&3.3/11kv grade) clamped on wall/ceiling with clamps and saddle clips partly laid in cable tray/partly laid in trench.-3 core 150Sq.mm.11kv, XLPE AL CablepOD93794/2025-2026:Od based on approved estimate no. Est/15232/2022 Supply, laying, testing and commissioning of the following size PVC/XLPE insulated, sheathed armoured Aluminium conductor cable (1100 volts&3.3/11kv grade) clamped on wall/ceiling with clamps and saddle clips partly laid in cable tray/partly laid in trench.-3 core 185 Sq.mm,3.3kV XLPE AL Cable.kOD93642/2025-2026:Od Based on approved Est No. Est /15232/2022 cabling -Supply, laying, testing and commissioning of the following size PVC/XLPE insulated, sheathed armoured Aluminium conductor cable (1100 volts&3.3/11kv grade) clamped on wall/ceiling with clamps and saddle clips partly laid in cable tray/partly laid in trench.- 3.5 core 50Sq.mm. AYFY CablelOD93643/2025-2026:Od Based on approved est no. Est/15232/2022 cabling -Supply, laying, testing and commissioning of the following size PVC/XLPE insulated, sheathed armoured Aluminium conductor cable (1100 volts&3.3/11kv grade) clamped on wall/ceiling with clamps and saddle clips partly laid in cable tray/partly laid in trench.-4 core 16 Sq.mm.PVC AL. Cable.kOD93644/2025
-2026:Od based on approved est no. Est/15232/2022 cabling -Supply, laying, testing and commissioning of the following size PVC/XLPE insulated, sheathed armoured Aluminium conductor cable (1100 volts&3.3/11kv grade) clamped on wall/ceiling with clamps and saddle clips partly laid in cable tray/partly laid in trench.-4 core 10 Sq.mm.PVC AL. Cable.OD93877/2025-2026: Supply ,erection,testing & amp commissioning of all materials and providing end termination of the following size PVC/XLPE insulated, sheathed armoured Aluminium conductor cable (1100 volts & amp 3.3/11kv grade ) for giving power connections to HT Breaker, Transformers, Panel boards etc. complete as per standards. 1 core 95 Sq.mm.3.3kv,XLPE AL Cable(Indoor)|OD93900/2025-2026:Supply , erection,testing and commissioning of all materials and providing end termination of the following size PVC/XLPE insulated, sheathed armoured Aluminium conductor cable (1100 volts & amp 3.3/11kv grade ) for giving power connections to HT Breaker, Transformers, Panel boards etc. complete as per standards.3 core 150 Sq.mm.11kv,XLPE AL Cable (Indoor)yOD93980/2025-2026:Supply ,erection,testing and comissioning of all materials and providing end termination of the following size PVC/XLPE insulated, sheathed armoured Aluminium conductor cable ( 1100 volts & amp 3.3/11kv grade ) for giving power connections to HT Breaker, Transformers, Panel boards etc. complete as per standards.3 core 150Sq.mm.11kv,XLPE AL Cable(Outdoor) OD93903/2025-2026:Od based on approved estimate no. Est/15232/2022 Supply , erection,testing and commissioninng of all materials and providing end termination of the following size PVC/XLPE insulated, sheathed armoured Aluminium conductor cable ( 1100 volts & 3.3/11kv grade ) for giving power connections to HT Breaker, Transformers, Panel boards etc. complete as per standards. 3core 185 Sq.mm.XLPE AL Cable. OD93905/2025-2026: Od based on approved estimate no. Est/15232/2022 Supply , erection,testing and commissioning of all materials and providing end termination of the following size PVC/XLPE insulated, sheathed armoured Aluminium conductor cable ( 1100 volts & amp 3.3/11kv grade ) for giving power connections to HT Breaker, Transformers, Panel boards etc. complete as per standards.3.5 core 50Sq.mm. AYFY CableOD93652/2025-2026:Od Based on approved estimate no. Est/15232/2022 Cabling -Supply of all materials and providing end termination of the following size PVC/XLPE insulated, sheathed armoured Aluminium conductor cable ( 1100 volts & 3.3/11kv grade ) for giving power connections to HT Breaker, Transformers, Panel boards etc. complete as per standards.4 core 16 Sq.mm.PVC AL. Cable.tOD93653/2025-2026:Od based on approved estimate no. Cabling -Supply of all materials and providing end termination of the following size PVC/XLPE insulated, sheathed armoured Aluminium conductor cable ( 1100 volts & 3.3/11kv grade ) for giving power connections to HT Breaker, Transformers, Panel boards etc. complete as per standards.4 core 10 Sq.mm.PVC AL. Cable.2OD93914/2025-2026:DAR 2022 5.6 Earthing Supply and providing plate earthing as per IS 3043 by using 600X 600X 3mm thick cast iron plate with 2.5mtrs. Long 40mm dia 'B' class GI watering pipe extended upto middle of CI plate and clamped to the plate by usig 3 nos. GI clamps made out of 25x6mm GI strip providing funnel with weld wire mesh. Providing 1 no. earth bus made out of 25x6mm copper strip of 30cm long clamped to the water pipe at top and interconnection of earth bus with CI plate by using 2 nos. 25x6mm copper strip of suitable length, filling earthing compound/ charcoal and salt at alternate intervels of 15cm all aournd CT plate. Providing masonry earth pit chambers of suitable size and covering with R.C.C/ CI chamber cover etc. complete. ( For 4 pole, transforner body and neutral, Panel boards etc)üOD93659/2025-2026:DAR 2022 5.8 Supply, laying and termination of the following sizes of copper strip/wires for earthing of substation, transformers, HTpanel boards,LT panel boards, equipments and inter connection of earth pits etc.25x6mm copper strips.úOD93662/2025-2026:DAR 2022 Supply, laying and termination of the following sizes of copper strip/wires for earthing of substation, transformers, HTpanel boards,LT panel boards, equipments and inter connection of earth pits etc.25x3mm copper strips.OD93675/2025-2026:Od based on approved estimate no. Est/15232/2022 Supply, laying and termination of the following sizes of copper strip/wires for earthing of substation, transformers, HTpanel boards,LT panel boards, equipments and inter connection of earth pits etc.25x6mm GI strips.OD93686/2025-2026: Od based on approved estimate no. Est/15232/2022 Supply, laying and termination of the following sizes of copper strip/wires for earthing of substation, transformers, HTpanel boards,LT panel boards, equipments and inter connection ofearth pits etc.32x6mm GI strips.AOD93922/2025-2026:Od based on approved estimate no. Est/15232/2022 Supply, laying , erection ,testing and commissioning, termination of the following sizes of copper strip/wires for earthing of substation, transformers, HTpanel boards,LT panel boards, equipments and inter connection of earth pits etc 50x6mm GI strips.dOD94012/2025-2026:Battery& Battery Charger. Supplying, fixing, testing and commissioning of Lead acid cell battery suitable for operation of the switchgears and protective equipments with sufficient Ah capacity at 10hrs rate of discharge assembled with plante positive and pasted negative plates with inter cell, inter raw, interior connectiors etc. stand and cell insulators, sealed floats, nuts, bolt, washersetc with electrolyte of specific gravity 1.190 and accessories such as voltmeter, Thermometer, Hydrometer, spaners etc with teak wood stand with 3 coats of antiacid paint to accomodate battery.ëOD94008/2025-2026:Od based on approved estimate no. Est/15232/2022 MS Items. Supply and fixing of 6mm thick checkered plate with required M.S. angle/plate supports over the masonry cable trench at substation and electrical control room. Angle and plate should be painted one coat of primer and two coats of enamel paint as required.Supply and fixing of M.S. angle cable tray for clamping the various sizes of cables in trenches, through walls, & trusses etc. as per KEI standards.MT¹OD93691/2025-2026:Od based on approved estimate no. Est/1
stage.html
html • 0.02 MB
tech_bid_open.pdf
cancelled_1.pdf
pdf • 0.09 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
KWAGeneralConditionsforeTenderingV5.pdf
PDF • 0.69 MB
Tendernotice_1.pdf
PDF • 0.33 MB
TechnicalBid.xls
Tender Documents • 0.18 MB
NIT-Vo-I.pdf
Tender Documents • 1.45 MB
NIT.pdf
Tender Documents • 12.46 MB
BOQ_1376761.xls
BOQ • 0.36 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .