Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.2 LAccepted-AOC AMARPUR GOMATI TRIPURA | AMARPUR | GOMATI | TRIPURA | ₹29.2 L | L1 | Accepted-AOC Due to successful bidder |
| 2 | L2₹29.9 LRejected-Finance JAGAHARIMURA AGARTALA WEST TRIPURA | AGARTALA | WEST TRIPURA | TRIPURA | ₹29.9 L | L2 | Rejected-Finance Due to L2 |
| 3 | L3₹32.5 LRejected-Finance POST OFFICE ROAD DHARMANAGAR DHARMANAGAR NORTH TRIPURA | NORTH TRIPURA | TRIPURA | 799250 | ₹32.5 L | L3 | Rejected-Finance Due to L3 |
| Sl No | Description | Qty | Unit | KAJAL DAS H2 | NIKHIL DAS H1 | UTTAM NAG H3 |
|---|---|---|---|---|---|---|
| 1.00Supply Items :- | ||||||
| 1.01 | ACSR Weasal (6/1/2.59mm) | 3.6 | Km | 18,792 ₹1.2 L | 19,440 ₹1.3 L | 11,664 ₹76,464 |
| 1.02 | PVC CABLES (SINGLE CORE) 95 mm2 | 0.5 | Km | 9,000 ₹59,000 | 7,200 ₹47,200 | 4,500 ₹29,500 |
| 1.03 | Rewireable Porcelain Cut out 200 Amp | 110 | Nos. | 7,920 ₹51,920 | 8,910 ₹58,410 | 7,920 ₹51,920 |
| 1.04 | 11KV Polymer composite 45 KN Disc Insulator | 108 | Nos. | 2,721.6 ₹17,841.60 | 2,916 ₹19,116 | 4,860 ₹31,860 |
| 1.05 | 11KV Polymer Pin Insulator | 162 | Nos. | 3,936.6 ₹25,806.60 | 4,374 ₹28,674 | 2,916 ₹19,116 |
| 1.06 | 11 KV Stay insulator | 54 | Nos. | 243 ₹1,593 | 340.2 ₹2,230.20 | 486 ₹3,186 |
| 1.07 | LT Shackle Insulator (3x 3.5) | 144 | Nos. | 518.4 ₹3,398.40 | 777.6 ₹5,097.60 | 777.6 ₹5,097.60 |
| 1.08 | 11KV Disc fittings Up to 7/3.8mm, 2-U Bolt type | 108 | Set | 3,693.6 ₹24,213.60 | 5,832 ₹38,232 | 4,860 ₹31,860 |
| 1.09 | LIGHTINING ARRESTOR 9
KV, 5KA Polymeric L/A | 54 | Nos. | 4,860 ₹31,860 | 5,346 ₹35,046 | 3,888 ₹25,488 |
Tender Value
₹38.7 L
EMD Value
₹77,409
Closing Date
11 Dec 2025, 3:00 pmClosed
Deputy General Manager, ED-Teliamura
Office of the Deputy General Manager, Electrical Divisioin-Teliamura
Extension of HT/LT line ic. construction of 18 nos 1x63 KVA DT SS for bifurcation of DWS scheme (ESD-I, Teliamura 2nos scheme, ESD-II, Teliamura 7nos scheme, ESD-Kalyanpur 7nos scheme and ESD-Mungiakami 2nos scheme) from Private cons. under ED-TLM
2025_POWER_67801_1
NIT NO DGM/ED-TLM/2025-26/03
Open Tender
Electrical Works
O/o the Deputy General Manager, ED-Teliamura
Please refer Tender Documents
5 documents required · 5 mandatory
₹5,000
₹77,409
27 Apr 2026
2 Dec 2025
11 Dec 2025
2 Dec 2025
11 Dec 2025
2 Dec 2025
ACSR Weasal (6/1/2.59mm)
PVC CABLES (SINGLE CORE) 95 mm2
Rewireable Porcelain Cut out 200 Amp
11KV Polymer composite 45 KN Disc Insulator
11KV Polymer Pin Insulator
11 KV Stay insulator
LT Shackle Insulator (3x 3.5)
11KV Disc fittings Up to 7/3.8mm, 2-U Bolt type
LIGHTINING ARRESTOR 9 KV, 5KA Polymeric L/A
GI Stay Set HT
GI Stay wire stranded stay wire 7-4mm
8SWG GI Wire
Straps with Nuts Bolts
Strain screw
BIMETALLIC LUGS 95mm2
PCC pole 8m long
PCC pole 9m long
11 KV Drop out Switch DOF Polymeric 3ph
Channel 100x50x6mm (Galvanised)
Channel 75x40x6mm (Galvanised)
Angle 65X65X6mm (Galvanised)
Angle 50x50x6mm (Galvanised)
11KV Gang Operated Switch (Polymeric type)
11 KV covered conductor (70 sqmm)
PG Clamp
HT/LT Bamboo Ladder
Erection of the following :- Erection of 9.0mtrs length of P.C.C POLE at any kind of soil upto a depth of 1/6 th of pole height, including excavation of earth, refilling the pit with with soil upto the ground level, ramming and making complete in all respect
Erection of Stay set direct in earth complete with 19mm x 1800 mm long stay rod, anchor plate of size 300 x 300 x 8 mm, thimble, turn buckle, 7/3.15 mm dia G.I Standed stay wire and stain insulator etc. with Supply of M.S.Clamp,Nuts & Bolts etc. as required. and making complete in all respect
Erection of M.S.Angle Cross-Arm,1.0 to 2.5 Mtr.Long 65 x65 x 6 mm/50X50X5 MM ( Excluding the cost of BackClamp, Nuts & Bolts)
Erection of M.S.Channel Cross-Arm,1.3 to 2.8 Mtr.Long75 x40 x 40 x 6 mm ( Excluding the cost ofBack Clamp, Nuts & Bolts)
Erection of M.S.Channel Cross-Arm,0.6 to 2.8 Mtr.Long100 x50 x 50 x 6 mm ( Excluding the cost ofBack Clamp, Nuts & Bolts)
Erection of 11KV Pin insulator along with Pin.
Erection of 11KV Single Disc insulator set along with necessary fittings
Earthing with G.I pipe 2.5mtr. Long and 40mm dia, including excavation, refilling with alternate layer of salt & Charcoal as per drawing (excluding supply of G.I.Pipe, Salt & Charcoal, Gi wire, nuts &boIts, etc. as required)
Laying of 8 SWG GI wire at 300mm below the ground level for earthing of Sub-Station equipments from the earth electrode
Febrication of Cross-Arms by MS Channel/MS Angle as per specification
Laying and Stringing of 1KM (Single Conductor) ACSR 6/1/2.59 mm dia WEASEL including hoisting and binding etc. Complete as required.
Laying & strining of 1KM (Single Conductor) 10/8 SWG GI wire including hoisting & binding etc. Complete as required
Erection of 9KV,5KA single pole metal oxide gapless type LA ,including necessary connection complete as per technical specification
Erection of 11KV DOF unit set of three nos. including necessary connection complete as per technical specification. (Excluding the cost of back clamp, Nuts & Bolts)
Erection of 11KV 200 Amp. GOS unit set of three nos. including necessary connection complete as per technical specification. (Excluding the cost of back cIamp,Nuts & Bolts)
Installation/Positioning of 1J/0.430KV,3-Phase 63KVA of Distribution Transformer on Pole with necessary connections & fitting fixing of all allied accessories components as required for making complete in all respect for energizing including 3-ph service connection.
Carriage of 11/0.430, 3-Phase 63KVA by Mechanical Transport from the Site /Store/Worshop to working site Vis-a-vis including loading, unloading and placing on base, as required, a)Upto the lead range 25KM From MMD Store to Sub Division Store
Erection of shackle insulator of size 75mm x 90mm/100mm x 15mm with straps & bolts/U clamp on poles ( Excluding the cost of cost of straps/ U Clamp, Nuts & Bolts)
Erection of 8 mtrs length of P.C.C POLE at any kind of soil , including excavation of earth, refilling the pit with soil upto the ground level, ramming and making complete in all respect
Supply of febricated clamps of assorted size of MS flat (50 x 6 mm) with double coat of red oxide primercoating
Supply of M.S.Nuts & Bolt i/c Washer of assortedsize ISI Marked machine made
Supply of 2.5mtr. Long , 40mm dia G.I.Pipe Make: TATA/ JINDAL)
Supply of 60Kg Salt & 55Kg Charcoal ( For 1 Pit).
Erection of M.S.Angle Cross-Arm bracket of wire ,upto 1100Mtr. Long of 50 x 50 x6mm/ 65x65 x 6 mm
Maintaining adequate clearance from overhead live conductors by Trimming of tree branches for Way Leaves
Providing Sub-Station protective fencing made by chain link mesh of 8 SWG GI Wire of size 2X3 mtr. And height 1.5 mtr. as per engineer requirement by 65X65X6 mm MS Angle post of height 2 mtr. Horizontal bar 2X3 mtr and 2X2 mtr. And top angle posts by 50X50X6 mm MS angle and two part MS Grill door of size 1.2X1.4 mtr with locking arrangement i/c necessary grouting and painted AL paint over red oxide priming of approved quality as required as per Technical Specification.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 3.91 MB
BOQ_68982.xls
BOQ • 0.35 MB
NIT03DWSBifercation.pdf
Tender Documents • 3.89 MB
NoticeInvitingTender.pdf
Additional Documents • 0.71 MB
Download all tender documents and submit your bid