GEMC-511687709519142
Awarded to RAJ ENGINEERS
₹75,187.20
Products
| Product | Brand / Model | HSN | Quantity | Unit Price | Amount |
|---|---|---|---|---|---|
| BATTERY CHARGER 1 STATION | RAJ , RE BC-1ST 12V 12AMP | - | 16 NOS | ₹4,699.20 | 75,187.2 |
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹75,187.20Qualified Make: AAR KEY .
Model: AAR KEY Battery Charger (One Stations) 1 No. Station Independent DASHMESH NAGAR DIGIANA JAMMU1 JAMMU JAMMU KASHMIR 180010 UDYAM JK 07 0004841 | JAMMU | JAMMU AND KASHMIR | 180010 | Make: AAR KEY .
Model: AAR KEY Battery Charger (One Stations) 1 No. Station Independent | ₹75,187.20 | L1 | Qualified MSE, Category: General |
| 2 | Not yet disclosed by govt. Qualified Make: RAJ ENGINEERS
Model: RAJ , RE BC-1ST 12V 12AMP | Make: RAJ ENGINEERS
Model: RAJ , RE BC-1ST 12V 12AMP | - | - | Qualified MSE, Category: General |
| 3 | Not yet disclosed by govt. Qualified Make: RS POWER
Model: SMPS 12V/12AMP/1 | Make: RS POWER
Model: SMPS 12V/12AMP/1 | - | - | Qualified MSE, Category: General |
Tender Value
Refer Docs
EMD Value
₹2,700
Closing Date
10 Sept 2018, 11:00 amClosed
battery chargers Average Turn Over of Last 3 Years 4 Lakh (s) Experience with Gov. Required 5 Year (s) Battery Chargers ( 16 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values Ungrouped GENERIC Charger technology SMPS Based SMPS Based Compatibility with battery type (User Selectable) Lead acid & Tubular &VRLA- SMF Lead acid & Tubular &VRLA- SMF Number of Independent charging stations (in numbers) 1 1 CONSTRUCTIONAL Input Voltage Range (VAC) 160 volt 270 volt (ISI MARKED POWER CORD TO BE PROVIDED) * AC surge protection AC surge protection at Input side with MOV (Metal Oxide Varistor) * Soft start and Soft stop feature without inrush current Yes * 1/4 Facility for charging deep discharged battery through pulse charging. yes * Not to charge battery in case one or more cells are internally short/Battery voltage less than 10.5V Yes * Digital display of output voltage and current Yes * LED Indication for Charging Status
Charged condition status and reverse polarity Yes * Cabinet Material CRCA Sheet * Cabinet Thickness (mm) minimum 1.2 mm * Length of Charging Cable for each station. (metre) Minimum 1.5 mtrs. Length (ISI MARKED Cable) * Size of Charging Cable for each station. (sq. mm) min. 6 sq.mm as per IS:694 ISI MARKED FLEXIBLE Cu cable per station * FUNCTIONAL Battery/battery bank Voltage (Volts) 12 Volts per station * Capacity of the battery to be charged(User Selectable) (AH) 7 aH TO 120 aH * Maximum Charger output current (Amp) 12 Ampere per station * Charging Cut-off Voltage per 12V battery (Volts) 14.5 volt +/-0.2 volt * Efficiency (%) >/= 75% * Ripple (Peak to Peak at Full Load) (millivolts) <100 * Reverse Polarity Protection Yes * Short Circuit Protection Yes * Over Current Protection Yes * Over voltage cutoff protection Over voltage protection at 280 volt at input and automatic recovery at 270 volt when the * 2/4 voltage is reduced from 280 volt Cut-in voltage for charging a discharged battery (Volts) Cut-in voltage shall be 10.5 Volt * Cut-off voltage for charging a discharged battery (Volts) Cut-off voltage shall be 14.5 V +/- 0.2 Volt * Minimum operating temperature (Degree Celsius) -10 * Maximum operating temperature (Degree Celsius) +55 * CERTIFICATIONS Availability of Type Test Report from Central Government NABL/ILAC Accredited lab To prove conformity to the specification Yes * Type Test report No. T&M/110 * Test report date 20/11/2013 * Name of Lab ETDC(GOVT OF INDIA) * Address of Lab PUNJAB * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Subhash Chand 171002
OFFICE OF THE SUPERINTENDENT OF POLICE
COMMUNICATION & TECHNICAL SERVICES. 16 30
519191
GEM/2018/B/73662
GeM Contract
battery chargers
GeM Contract
30 days
Himachal Pradesh; Shimla
PRODUCT
Awarded to RAJ ENGINEERS
₹75,187.20
| Product | Brand / Model | HSN | Quantity | Unit Price | Amount |
|---|---|---|---|---|---|
| BATTERY CHARGER 1 STATION | RAJ , RE BC-1ST 12V 12AMP | - | 16 NOS | ₹4,699.20 | 75,187.2 |
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| battery chargers Average Turn Over of Last 3 Years 4 Lakh (s) Experience with Gov. Required 5 Year (s) Battery Chargers ( 16 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values Ungrouped GENERIC Charger technology SMPS Based SMPS Based Compatibility with battery type (User Selectable) Lead acid & Tubular &VRLA- SMF Lead acid & Tubular &VRLA- SMF Number of Independent charging stations (in numbers) 1 1 CONSTRUCTIONAL Input Voltage Range (VAC) 160 volt 270 volt (ISI MARKED POWER CORD TO BE PROVIDED) * AC surge protection AC surge protection at Input side with MOV (Metal Oxide Varistor) * Soft start and Soft stop feature without inrush current Yes * 1/4 Facility for charging deep discharged battery through pulse charging. yes * Not to charge battery in case one or more cells are internally short/Battery voltage less than 10.5V Yes * Digital display of output voltage and current Yes * LED Indication for Charging Status | - | - | - |
| Charged condition status and reverse polarity Yes * Cabinet Material CRCA Sheet * Cabinet Thickness (mm) minimum 1.2 mm * Length of Charging Cable for each station. (metre) Minimum 1.5 mtrs. Length (ISI MARKED Cable) * Size of Charging Cable for each station. (sq. mm) min. 6 sq.mm as per IS:694 ISI MARKED FLEXIBLE Cu cable per station * FUNCTIONAL Battery/battery bank Voltage (Volts) 12 Volts per station * Capacity of the battery to be charged(User Selectable) (AH) 7 aH TO 120 aH * Maximum Charger output current (Amp) 12 Ampere per station * Charging Cut-off Voltage per 12V battery (Volts) 14.5 volt +/-0.2 volt * Efficiency (%) >/= 75% * Ripple (Peak to Peak at Full Load) (millivolts) <100 * Reverse Polarity Protection Yes * Short Circuit Protection Yes * Over Current Protection Yes * Over voltage cutoff protection Over voltage protection at 280 volt at input and automatic recovery at 270 volt when the * 2/4 voltage is reduced from 280 volt Cut-in voltage for charging a discharged battery (Volts) Cut-in voltage shall be 10.5 Volt * Cut-off voltage for charging a discharged battery (Volts) Cut-off voltage shall be 14.5 V +/- 0.2 Volt * Minimum operating temperature (Degree Celsius) -10 * Maximum operating temperature (Degree Celsius) +55 * CERTIFICATIONS Availability of Type Test Report from Central Government NABL/ILAC Accredited lab To prove conformity to the specification Yes * Type Test report No. T&M/110 * Test report date 20/11/2013 * Name of Lab ETDC(GOVT OF INDIA) * Address of Lab PUNJAB * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Subhash Chand 171002 | - | - | - |
| OFFICE OF THE SUPERINTENDENT OF POLICE | - | - | - |
| COMMUNICATION & TECHNICAL SERVICES. 16 30 | - | - | - |
₹2,700
19 Sept 2018
25 Aug 2018
contract_GEMC-511687709519142.pdf
GEM_CONTRACT • 0.02 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_519191.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .