Loading…
Loading…
24 results • Latest
OMKARA SPORTS Single heel and toe socks Gents (as per IS), OMKARA SPORTS Single heel and toe socks Gents (as per IS)
Unbranded Olive Green Socks, Men's Wool as per Defence Specification, Unbranded Olive Green Socks, Men's Wool as per Defence Specification No.JSS:8440-06:2000 (Revision No. 2) of Size 30
MWP Cap Comforter Khaki Any other Mothproofing Agent, MWP Cap Comforter Khaki Any other Mothproofing Agent approved by Buyer
LOTUS Snow Goggles (Defence) Defence specification for Snow Goggles,, LOTUS Snow Goggles (Defence) Defence specification for Snow Goggles, issued by Ministry of Defence vide specification No. CQA(GS)/Prov/G-7/1/08(a)
Unbranded Climbing Rope Nylon, Glacier Region - Defence Nylon, Unbranded Climbing Rope Nylon, Glacier Region - Defence Nylon 6 and Nylon 66
KANIB Battery Chargers for GP-328 Transreceiers
AKEW SPARE / Add on ANTENNA for Transreceiver/Repeater - Mobile/, AKEW SPARE / Add on ANTENNA for Transreceiver/Repeater - Mobile/ Static/ Handheld " 6 db " Omni directional antenna / GP antenna 380-512
Digital Base/Mobile Transceiver Set (MOBILE RADIO) Bidder Turnover (Last 3 Years) 7 Lakh (s)
Digital Handheld Transceiver Set (HANDHELD RADIO) Bidder Turnover (Last 3 Years) 9 Lakh (s)
Desktop Computers
Online Ups-IS:9000 Bidder Turnover (Last 3 Years) 3 Lakh (s)
Computer Printers
Online UPS
Multifunction Machines MFM
Desktop Computers, Online UPS Average Turnover (Last 3 Years) 33 Lakh (s)
Digital Transceiver-MOBILE RADIO Average Turnover (Last 3 Years) 7 Lakh (s)
Revolving Chair
Digital Transreceiver-Handheld
All in One PC Average Turnover (Last 3 Years) 10 Lakh (s)
Laptop-Notebook
Online UPS
battery chargers Average Turn Over of Last 3 Years 4 Lakh (s) Experience with Gov. Required 5 Year (s) Battery Chargers ( 16 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values Ungrouped GENERIC Charger technology SMPS Based SMPS Based Compatibility with battery type (User Selectable) Lead acid & Tubular &VRLA- SMF Lead acid & Tubular &VRLA- SMF Number of Independent charging stations (in numbers) 1 1 CONSTRUCTIONAL Input Voltage Range (VAC) 160 volt 270 volt (ISI MARKED POWER CORD TO BE PROVIDED) * AC surge protection AC surge protection at Input side with MOV (Metal Oxide Varistor) * Soft start and Soft stop feature without inrush current Yes * 1/4 Facility for charging deep discharged battery through pulse charging. yes * Not to charge battery in case one or more cells are internally short/Battery voltage less than 10.5V Yes * Digital display of output voltage and current Yes * LED Indication for Charging Status, Charged condition status and reverse polarity Yes * Cabinet Material CRCA Sheet * Cabinet Thickness (mm) minimum 1.2 mm * Length of Charging Cable for each station. (metre) Minimum 1.5 mtrs. Length (ISI MARKED Cable) * Size of Charging Cable for each station. (sq. mm) min. 6 sq.mm as per IS:694 ISI MARKED FLEXIBLE Cu cable per station * FUNCTIONAL Battery/battery bank Voltage (Volts) 12 Volts per station * Capacity of the battery to be charged(User Selectable) (AH) 7 aH TO 120 aH * Maximum Charger output current (Amp) 12 Ampere per station * Charging Cut-off Voltage per 12V battery (Volts) 14.5 volt +/-0.2 volt * Efficiency (%) >/= 75% * Ripple (Peak to Peak at Full Load) (millivolts) <100 * Reverse Polarity Protection Yes * Short Circuit Protection Yes * Over Current Protection Yes * Over voltage cutoff protection Over voltage protection at 280 volt at input and automatic recovery at 270 volt when the * 2/4 voltage is reduced from 280 volt Cut-in voltage for charging a discharged battery (Volts) Cut-in voltage shall be 10.5 Volt * Cut-off voltage for charging a discharged battery (Volts) Cut-off voltage shall be 14.5 V +/- 0.2 Volt * Minimum operating temperature (Degree Celsius) -10 * Maximum operating temperature (Degree Celsius) +55 * CERTIFICATIONS Availability of Type Test Report from Central Government NABL/ILAC Accredited lab To prove conformity to the specification Yes * Type Test report No. T&M/110 * Test report date 20/11/2013 * Name of Lab ETDC(GOVT OF INDIA) * Address of Lab PUNJAB * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Subhash Chand 171002, OFFICE OF THE SUPERINTENDENT OF POLICE, COMMUNICATION & TECHNICAL SERVICES. 16 30
power generators and portable generator Average Turn Over of Last 3 Years 55 Lakh (s) Experience with Gov. Required 5 Year (s) Power Generators And Portable Generator ( 16 ) Technical Specifications Specification Specification Name Values Allowed Values RATED OUTPUT STARTING & RUNNING Portable Generator type Petrol start, Petrol run Petrol start, Petrol run Rated Output at unity power factor at STP (VA) 2800 2800 Starting Type Electric Self start Electric Self start Rated output Voltage 230 V AC 230 V AC WARRANTY Warranty (year) 1.0 1, 2, 3 PERFORMANCE Efficiency of the alternator (%) 80.0 - Noise Level of Portable Generator (dB(A)) 86.0 - GENERIC Make and model of engine - - Make and model of alternator - - Provision of Voltmeter and ammeter in the output circuits yes - 1/3 Dimension of Genset in (LxWxH) (mmxmmxmm) - - Dry weight (Kg) - - Period for which the Generator is capable of delivering declared output 6.9 - Fuel Tank capacity - - BATTERY Battery Ah capacity in case of Electric start Generator (Ah) - - CERTIFICATION STATUTORY REQUIREMENTS Type approval Portable Generating Set meeting the requirements of Environmental (Protection) Rules 1986, in respect of noise and emission norms, as described in STC of the Product yes - Type approval number and date - - Availability of Test Report from Central government/NABL/ILAC accredited laboratory to prove conformity to the specification for the Portable Generator Set Yes - Test Report number and date - - Name and address of laboratory - - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Subhash Chand 171002, OFFICE OF THE SUPERINTENDENT OF POLICE, COMMUNICATION & TECHNICAL SERVICES. 16 30
Honda Portable Generator