| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.2 CrAccepted-AOC FLAT NO 304 SN TOWERS JAGANNADHAPURAM JUNCTION AKKAYYAPALEM VISAKHAPATNAM 530 016 | VISAKHAPATANAM | ANDHRA PRADESH | 530016 | ₹3.2 Cr | L1 | Accepted-AOC Tender awarded to M S Murali Krishna Associates Index No A -154 CEEC on 30 Sep 2020 being the lowest tenderer |
| 2 | L2₹3.5 Cr+₹32.1 L (9.96%)Rejected-Finance | ₹3.5 Cr+₹32.1 L (9.96%) | L2 | Rejected-Finance Being other than the Lowest tenderer |
| 3 | L3₹3.7 Cr+₹45.9 L (14.2%)Rejected-Finance MIG 1 12 GULLALAPALEM VUDA COLONY SRIHARIPURAM MALKAPURAM POST VISAKHAPATNAM 530 011 | VISAKHAPATNAM | VISAKHAPATNAM | ANDHRA PRADESH | 530011 | ₹3.7 Cr+₹45.9 L (14.2%) | L3 | Rejected-Finance Being other than the Lowest tenderer |
| 4 | L4₹3.9 Cr+₹71.4 L (22.1%)Rejected-Finance | ₹3.9 Cr+₹71.4 L (22.1%) | L4 | Rejected-Finance Being other than the Lowest tenderer |
| 5 | Rejected-Technical | - | - | Rejected-Technical Not Meeting the Eligible Criteria as per NIT |
Tender Value
Refer Docs
EMD Value
₹4.1 L
Closing Date
19 Sept 2020, 6:00 pmClosed
CWE No2 Visakhapatnam
CWE No2 Chief Engineer complex Station Road Visakhapatnam 530004
CONSTRUCTION OF OFFICE AND TRANSIT MESS FOR DEFENCE ESTATE OFFICE AT VISAKHAPATNAM
2020_MES_363300_2
82478
Open Tender
Civil Works
Lump-sum
910 days
GE P N Visakhapatnam
Class A cat a i
6 documents required · 6 mandatory
₹2,000
Yes
GE P N Visakhapatnam
₹4.1 L
Yes
1 Oct 2020
20 Aug 2020
22 Sept 2020
20 Aug 2020
19 Sept 2020
22 Aug 2020
20 Aug 2020 - 21 Aug 2020
Amount
Schedule "A" Part – I to Schedule "A" Part – XIV: NOTE: Schedule "A" Part – I to Part – XIV are prepriced by MES. Bidders shall insert their Lumpsum amount in Green coloured field under Column - 6 only
Lumpsum price worked out by the contractor for “BUILDINGS/STRUCTURES” as listed in Schedule ‘A’ Part - I , inserted by MES on serial page No. 32
Lumpsum price worked out by the contractor for "Demolition and Dismantling ", as listed in Schedule "A" Part – II on Serial Page No. 34.
Lumpsum price worked out by the contractor for "Site Clearance / Area Development / Earthwork Excavation", as listed in Schedule "A" Part – III on Serial Page No.36.
Lumpsum price worked out by the contractor for “INTERNAL WATER SUPPLY” as listed in Schedule ‘A’ Part - IV , inserted by MES on serial page No. 38
Lumpsum price worked out by the contractor for “INTERNAL ELECTRIFICATION” as listed in Schedule ‘A’ Part - V , inserted by MES on serial page No. 40
Lumpsum price worked out by the contractor for "Road / Path / Culvert", as listed in Schedule "A" Part – VI on Serial Page No. 42.
Lumpsum price worked out by the contractor for "Sewage Disposal", as listed in Schedule "A" Part – VII on Serial Page No. 44.
Lumpsum price worked out by the contractor for "Area Drainage", as listed in Schedule "A" Part – VIII on Serial Page No. 46.
Lumpsum price worked out by the contractor for "Compound wall/Fencing/Gate", as listed in Schedule "A" Part – IX on Serial Page No. 48.
Lumpsum price worked out by the contractor for "External Water Supply", as listed in Schedule "A" Part – X on Serial Page No. 49.
Lumpsum price worked out by the contractor for "External Electrification", as listed in Schedule "A" Part – XI on Serial Page No. 53.
Lumpsum price worked out by the contractor for "Lightening ptotection", as listed in Schedule "A" Part – XII on Serial Page No. 55.
Lumpsum price worked out by the contractor for "Fire Fighting System", as listed in Schedule "A" Part – XIII on Serial Page No. 58.
Lumpsum price worked out by the contractor for "Fire Alarm System", as listed in Schedule "A" Part – XIV on Serial Page No. 60.
Schedule "A" Part - XV: [Miscellaneous Items for Sch "A" Part-IV to XIV and Water cooler,Air conditioning] are not prepriced by MES and prepriced rate indicated as 0.00 under Col.5 signifies this fact only. Bidder shall insert their rates in Green colour filled under Col-6.
S&F 15 mm CP wall mixer 3 in 1 for mixing hot & cold water with provision of overhead shower and hand shower both screwed down for GI pipes complete all as directed. Make: Cat No. BA-7380 of Prayag or equivalent model in Cera/Parry ware/ Hindware/ Jaquar as approved by GE.
M&L Point Wiring complete with 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable, confirming to IS - 694 drawn through and including heavy duty PVC Conduit, 20 mm dia including all accessories concealed in Walls / Roofs / Floors / Ceiling etc. and Pressed Metal Flush Box made out of 2mm thick MS Sheet of suitable size and 3 mm thick Hylam Sheet top cover for fixing switches, fittings, regulators etc. concealed in walls, including 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable as earth continuity conductor with colour coding and connecting to Earth Dolly for One Light / Fan Point / Bell Point controlled by One Switch complete all as specified.
All as per Serial Item No. 18 above but One Light Point controlled by Two Nos. of, Two way Switches complete all as specified.
All as per Item No.18 above but one 3 pin switch socket outlet 5 Amps on independent board complete all as specified.
M&L Point wiring with 2.50 Sqmm (Nominal area) PVC insulated Unsheathed cable FRLS grade with copper conductors, single core, multi stranded 1100 Volts, ISI marked (IS 694) (For Phase, neutral ) drawn through and including 20mm dia PVC rigid conduit ISI marked, (IS 9537 Part III) Heavy grade with conduit accessories including concealed steel terminal boxes fabricated out of 2mm thick MS sheet, fitted with 3mm thick masonite or approved laminated sheet top cover for fixing switches, sockets etc, including 2.5 sq mm FRLS multistranded copper conductor cable as continuous earth wire complete and connecting the earth wire to common earth dolly for one 3 pin socket outlet 15 Amps on independent board complete all as specified
S&F Energy efficient,4 feet LED Light fitting,T5 fitting with tube 20 watt or nearest size,230 V,surface mounted,LED batten type with extruded aluminium/CRCA housing and robust construction with necessary acrylic cover as diffuser with mounting bracket,etc including connecting up with 3 core 1 sqmm,multistranded copper cable up to ceiling rose complete all as specified and directed. Make: Havells/ Philips/Surya Roshini/ Wipro/ GE /Bajaj.
S&F Energy efficient,2 feet LED Light fitting,T5 fitting with tube 10 watt or nearest size,230 V,surface mounted,LED batten type with extruded aluminium/CRCA housing and robust construction with necessary acrylic cover as diffuser with mounting bracket,etc including connecting up with 3 core 1 sqmm,multistranded copper cable up to ceiling rose complete all as specified and directed. Make: Cat No. LUMILINE PLUS BS 10 W LED 865 PCSS of Havells or equivalent model in Philips/ Surya Roshini/ Wipro/ GE /CG/Bajaj.
S&F LED Light fitting,18 watt 6500 K,slim,compact, aluminium die cast edge lift panel,recess mounted round fixture with opal diffuser and electronic driver,etc including connecting up with 3 core 1 sqmm,multistranded copper cable up to ceiling rose complete all as specified and directed. Make: Cat No. LCTLSN-18-CDL of CG or equivalent model in Havells/ Philips/Surya Roshini/ Wipro/ GE /Bajaj.
S&F LED security light fitting of 1x 20 W,new generation energy saving and environment friendly,long life versatile, pressure diecast aluminium luminiare with mid power LEDs as source and HF electronic driver including 40 mm bore light grade GI pipe bracket 1500 mm long and flat iron clamps and connecting up with 3 core 1 sqmm,multistranded copper cable complete all as specified and directed. Make : Cat No. LST-20-CDL of CG or equivalent model in Havells/ Bajaj/Philips/Surya Roshini/Wipro
M&L for Circuit/sub main wiring along with earth wire concealed with two runs of 6 sq. mm multistranded copper conductor cable FRLS grade 1100 volt and one run of 6 Sq.mm multistranded copper conductor cable FRLSH grade 1100 volt drawn through and including PVC rigid conduit heavy grade 25 mm dia complete all as specified. Note: Three runs of 6 Sq.mm cable and one run of PVC conduit will be measured as one unit.
M&L for Circuit/sub main wiring along with earth wire concealed with two runs of 4 sq. mm multistranded copper conductor cable FRLS grade 1100 volt and one run of 4 Sq.mm multistranded copper conductor cable FRLSH grade 1100 volt drawn through and including PVC rigid conduit heavy grade 25 mm dia complete all as specified. Note: Three runs of 4 Sq.mm cable and one run of PVC conduit will be measured as one unit.
S&F Non metallic PVC rigid conduit heavy grade 20 mm dia including bends, tees, elbows,reducers,bell mouth tube ends, saddles,etc concealed in walls for drawing telephone/TV cables complete all as specified and directed.
S&F Ceiling fan 1200mm sweep energy saving model BEE 5 star rating with all fittings complete all as specified. Make- Havells model ES-40,5 Star or equivalent model in CG/Bajaj/Khaitan.
S&F Exhaust fan heavy duty 200mm sweep, 900 RPM, 5 star rated,AC single phase 230 volts with louver shutter (with mosquito net), including 1 sqmm flexible wire with copper conductor from ceiling rose to exhaust fan complete all as specified and directed. Make - Turbo force of Havells or its equivalent in Bajaj/Crompton
S&F Exhaust fan heavy duty 450mm sweep, 900 RPM, 5 star rated,AC single phase 230 volts with louver shutter (with mosquito net), including 1 sqmm flexible wire with copper conductor from ceiling rose to exhaust fan complete all as specified and directed. Make - Turbo force of Havells or its equivalent in Bajaj/Crompton
S & F Concealed in wall Vertical distribution board, double door type, TPN 4 way,415 V,50 Hz IP-43 protection with 200 Amps rated bus bar including provision of mount MCCB FP 40 Amps,10 KA and out going circuit complete all as specified and directed by Eng-in-charge.
S & F MCCB,3 pole, 100 Amps, 16 KA,415 Volts , 50 Hz complete all as specified and directed by Eng-in-charge.
S & F MCB SPN 32 Amps,240 Volts breaking capacity 10 KA,C Series,complete all as specified and directed by Eng-in-charge.
S & F MCB SP 6 to 32 Amps, 240 Volts , breaking capacity 10 KA "C" series complete all as specified.
S&F 160 mm bore PVC (SWR) pipes double socketed in any length with rubber ring joints, fixed to walls including necessary clamps as fixed in repairs complete all as specified.
M&L for cutting existing GI lines 100/80 mm dia bore including insertion of TEE of size 100 x 100 x 80 mm dia for branch connection with necessary GI specials as required at site including excavation and earth work complete all as specified and directed.
M&L for construction of brick masonary valve chamber of internal size 900x 900x 900 mm with foundation of 150 mm thick PCC (1:4:8) type D2(using 40 mm graded stone aggregate) and brick masonry 230 mm thick walls built in CM 1:6 and 15 mm thick rendering in CM 1:4 on brick wall inside and external up to 15 CM below GL and 50 mm thick PCC (1:3:6) type C1 (using 20 mm graded stone aggregate) for coping on top of walls including providing of 65x65x6 mm thick angle iron frame grouted to brick wall with 3.15 mm thick MS sheet cover with hinges, lifting handle and locking arrangement,etc duly painted with two coats of synthetic enamel paint over a coat of red oxide primer including earth work excavation in any type of soil,return filling,removal,etc complete all as specified and directed.
M&L for Pre-fabricated MS gate 5.50 m wide,2m height (with wicket gate) made out of MS angle iron sections,MS sheet,square bars,etc including pintal hinges,hold fasts fixing to the columns and applying 2 coats of synthetic enamel paint ovver a coat of primer complete all as shown on drawing No. CEDD/86/TD/2/1 Sheet No.1/1 and as directed by Eng-in-charge.
M&L for Lightning arresters expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo amp of Suitable for 11KV complete all as specified and as directed.
Supply, Erection, Testing and commisioning of 100 KVA, Double copper wound transformer, step down, outdoor type, Oil immersed, C.R.G.O. Core Type Naturally cooled, built-up with class “A" insulation complete with standard fittings, HT 11 KV 3 Phase, LT 433 volts, 3 Phase 4 wire with off load tappings on HT side to vary secondary voltage within limit, all design and construction as per IS:1180 with following accessories complete all as specified and directed :- (a) Continuous Rating : 100 KVA (b) No-load Voltage, Ratio : 11000/433 Volts. (c) Tapping on HV (%) : 土7.5,土5,土2.5 (d) Phase & Frequency : 3 Phase & 50Hz. (e) Vector Group : Dyn 11 (f) Connection : Delta/Star (g) Type of Cooling : ONAN (Oil Natural Air Natural) TERMINAL ARRANGEMENT: (i) HV Side : 03(Three Nos) of Weatherproof Bare Bushing type terminals. (ii) LV Slde : Quadfurcating Cable Box with copper bus bar terminal suitable to connect PVC cable and One additional Neutral Bushing terminal will be brought out separately for earthing purpose. Fittings : (i) Externally hand operated off circuit Tap Switch with position indicator and locking device. (ii) Conservator with oil gauge, filling hole with plug & drain hole with plug.
(iii) Under carriage with four plain rollers. (iv) Oil filling hole cum air release plug (v) Drain valve cum sampling valve. (vi) Top filter valve with plug. (vii) Rating Plate & Diagram Plate. (viii) 02 Nos lifting lugs for Transfomer and lid,core. (ix) Thermometer Pockets (x) 02 Nos earthing Teminals. (xi) Silica gel Breather andexplosion vent (xii) Double float Buchholz with alarm and trip contacts including control cable of copper conductor from marshalling box to relay of VCB. (xiii) 150 mm size oil temperature indicator dial type with alarm and trip contacts.(xiv) 150 mm size winding temperature indicator dial type with alarm and trip contacts (xv) Buchholz relay with 2 shut-off valves (xvi) Marshalling box with double window and OCTC. (xvii) First new transformer oil fill up to recommended level by manufacturer confirming to IS:335 and tested up to 50 KV die-electric strength at 2.5 mm air gap between testing electrodes, certification of the same shall be submitted by contractor. (xviii) Apart from routine tests mentioned in the PS and relevant IS,Pre commissioning inspection of transformer shall be carried out by Senior Electrical Inspector. Make of transformer : Voltamp / Siemens / Crompton Greaves / Alstom / Schneider / ABB / Bharat Bijlee/ M/s Indian Transformers and Electricals Pvt Ltd
M&L for Brick masonry platform of size 1.50mx1.50m x 1.20 m height above GL for transformer using flyash bricks and foundation with 200 mm thick PCC (1:3:6) type C1 (using 40 mm graded stone aggregate) including necessary earth work excavation,return filling,removal of surplus soil and rendering with 15 mm thick CM(1:4) with WPC on all sides and 100 mm belo GL and applying 2 coats of cement base paint over a coat of primer complte all as directed by Eng-in-charge.
Supply, laying, testing and commissioning of HT UG XLPE cable,FRLS Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 11000 Volts grade with stranded aluminium conductor of size 3 core 95 sq mm,complete all as specified and directed.
Supply, jointing, testing and commissioning of cable jointing kit for 11 KV (earthed) grade cable for out door termination joint (heat shrinkable type) complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sq mm to 95 sqmm complete all as specified.
Supply, lay, test & commissioning of FRLS LT UG XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 1100 volts grade, of size 3.5 core, 95 sq mm, complete all as specified and directed.
Supply, lay, test & commissioning of FRLS LT UG XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 1100 volts grade, of size 3.5 core, 50 sq mm, complete all as specified and directed.
Supply, lay, test & commissioning of FRLS LT UG XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 1100 volts grade, of size 4 core, 10 sq mm, complete all as specified and directed.
Supply, lay, test & commissioning of FRLS LT UG XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 1100 volts grade, of size 4 core, 16 sq mm, complete all as specified and directed.
M&L Boring of holes below ground level in any strata i.e road/pavement/hard standing by means of trenchless technology using ultra sound technique with nececessary machine including 150 mm dia HDPE pipe suitable for 0.40 Mpa working pressure,complete all as directed by Eng-in-charge
S&F Integral LED street light Luminaire 72 Watts, comprising of epoxy powder coated, Pressure die cast aluminium housing enclosed with glass cover in frame, with suitable size of bracket, nut and bolts, PVC insulated three core flexible cable of suitable size and length duly connected to light fitting complete including installation and testing Make:- Bajaj cat part No. BRTFG 72W LED or equivalent of Model in Philips/ CG/ Havells
S&F Loop in Loop out thermo plastic cable junction box of size 250 x 250x100 mm for street light pole made out of FRP box with locking arrangement with IP 65 protection with MCB SP 04 Amps and 4 porcelain terminals as bus terminals and two number of cable entry gland of standard size with 2 Nos suitable stainless steel bracket to fix the pole and duly painted complete all as directed.
Supply and fix time switch 415 V, single phase of max 20 Amps rated, with contractor fitting inside steel encloser.
Supply, install, test and commissioning of factory made LT Panel board made out of CRCA sheet 3.15 mm thick out door Pedestal type totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of Switcher gear about termination of switch gear, and the nuts/ bolts etc used are to be made of rust proof material incl as per IS: 8623 Aluminium bus bar with heat proof colour code, insulators suitable for three phase and neutral of capacity 250Amp, 50 Hz 415 V complete with powder coating, necessary internal electric connection as required and provision of the following: INCOMER a) LT 440 volts 3 phase, 4 wire 50 cycles, 25kA, Adjustable type MCCB of 160 Amp rated complete with overload protection, no-volt thermal based release. OUTGOING b) LT 440 volts 3 phase, 4 wire 50 cycles, 25 kA, Adjustable type MCCB of 160 Amp rated complete with overload protection, no-volt thermal based release.- 02 Nos. c) LED Indicating Lamps for each phase with colour code Red Yellow Blue for R, Y and B Phases d) Multifunctional Intelligent Panel Meter digital type for measuring Volts, Current, Hz, pf, power, energy, THD along with connected CTs.
Supply, install, test and commissioning of factory made LT Panel board made out of CRCA sheet 3.15 mm thick out door Pedestal type totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of Switcher gear about termination of switch gear, and the nuts/ bolts etc used are to be made of rust proof material incl as per IS: 8623 Aluminium bus bar with heat proof colour code, insulators suitable for three phase and neutral of capacity 400Amp, 50 Hz 415 V complete with powder coating, necessary internal electric connection as required and provision of the following: INCOMER a) LT 440 volts 3 phase, 4 wire 50 cycles, 25KA, Adjustable type MCCB of 160 Amp rated complete with overload protection, no-volt thermal based release-01 No.. OUTGOING b) LT 440 volts 3 phase, 4 wire 50 cycles, 25 KA, Adjustable type MCCB of 125 Amp rated complete with overload protection, no-volt thermal based release.- 02 Nos. c) LT 440 volts 3 phase, 4 wire 50 cycles, 16 kA, Adjustable type MCCB of 63 Amp overload protection, no-volt thermal based release- 04 Nos and 10 KA MCB of 32 Amps-02 Nos. d) LED Indicating Lamps for each phase with colour code Red Yellow Blue for R, Y and B Phases e) Multifunctional Intelligent Panel Meter digital type for measuring Volts, Current, Hz, pf, power, energy, THD along with connected CTs.
M&L Earthing complete with galvanised steel earth plate electrode 600×600× 6mm thick, buried directly and preferably vertically in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to GI earth lead wire 4 mm dia (up to 7.5 m in length from earth plate ) by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 5 connected to earthing test point including earth work and excavtion in any type of soil, PCC 1:3:6 type C1 chamber and RCC 1:2:4 type B1 cover 40 mm thick, with 8mm dia steel deformed (TMT bars) reinforcement at 150mm c/c both ways, 20mm dia GI light grade pipe for earth lead protection, 20 mm dia GI medium grade pipe for watering, water funnel, testing point etc complete all as specified and directed by Eng-in-charge and testing on completion.
M&L Earthing complete with galvanised steel earth plate electrode 600×600× 6mm thick, buried directly and preferably vertically in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised iron strip 32x6mm (up to 7.5 m in length from earth plate ) by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 5 connected to earthing test point including earth work and excavtion in any type of soil, PCC 1:3:6 type C1 chamber and RCC 1:2:4 type B1 cover 40 mm thick, with 8mm dia steel deformed (TMT bars) reinforcement at 150mm c/c both ways, 20mm dia GI light grade pipe for earth lead protection, 20 mm dia GI medium grade pipe for watering, water funnel, testing point etc complete all as specified and directed by Eng-in-charge and testing on completion.
S&F Double-flanged ductile iron pipe 100 mm NB, conforming to IS: 8329, class K9, including all necessary pipe fittings like elbows, tees, flanges, tapers, nuts, bolts, gaskets etc., in ground including earth work in any type of soil & providing cement concrete blocks as supports, RCC thrust blocks for fittings, hydrant stand posts and risers , refilling the trench with sand 100 mm around the pipe and earth up to normal ground level etc. of following sizes for underground piping all as specified and directed
S&F Fire pump diesel engine driven horizontal end suction, centrifugal type confirming to IS- 12469 1988 with CI casing , bronze impeller and stainless steel shaft mounted on heavy duty bearings suitable for continuous operation with 'range of operation' 0 % to 150 % of rated capacity for 440 V , 3 phase, 50 Hz AC supply 70 m Head. 1620 LPM discharge at 3.5 Kg/sqcm along with 180AH batteries-02 Nos 12 Volt complete all as directed.
S&F Fire pump electrically driven horizontal end suction, centrifugal type confirming to IS- 12469 1988 with CI casing , bronze impeller and stainless steel shaft mounted on heavy duty bearings suitable for continuous operation with 'range of operation' 0 % to 150 % of rated capacity for 440 V , 3 phase, 50 Hz AC supply 70 m Head. 1620 LPM discharge at 3.5 Kg/sqcm complete all as directed.
S&F Jockey pump horizontal end suction centrifugal type Confirming to IS- 12469: 1988 with CI casing , bronze impeller and stainless steel shaft mounted on heavy duty bearings suitable for automatic operation with non over loading power characteristics for frequent start / stop operations for 440 V , 3 phase, 50 Hz 70m head 180 LPM discharge including PCC foundation complete all as specified and as directed.
Supply, install, test and commissioning of factory made LT Panel board made out of CRCA sheet 2 mm thick indoor Pedestal type totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of Switcher gear about termination of switch gear, and the nuts/ bolts etc used are to be made of rust proof material incl as per IS: 8623 Aluminium bus bar with heat proof colour code, insulators suitable for three phase and neutral of capacity 300Amp, 50 Hz 415 V complete with powder coating, necessary internal electric connection as required and provision of the following: INCOMER a) LT 440 volts 3 phase, 4 wire 50 cycles, 25kA, Adjustable type MCCB of 200 Amp rated complete with overload protection, no-volt thermal based release. OUTGOING b) LT 440 volts 3 phase, 4 wire 50 cycles, 25 kA, Adjustable type MCCB of 125 Amp rated complete with overload protection, no-volt thermal based release.- 02 Nos. c) LT 440 volts 3 phase, 4 wire 50 cycles, 25 kA, Adjustable type MCCB of 63 Amp rated complete with overload protection, no-volt thermal based release.- 06 Nos. d) Star delta Starter fully automatic suitable for 415 V AC For 75 HP motor.- 01 No and starter suitable for Jocky pump-01 No. e) LED Indicating Lamps for each phase with colour code Red Yellow Blue for R, Y and B Phases f) Multifunctional Intelligent Panel Meter digital type for measuring Volts, Current, Hz, pf, power, energy, THD along with connected CTs.
S&F Foot valve, ISI marked,150 mm dia flanged end lift type with brass strainer,suitable flanges,gaskets,bolts,nuts and washers complete all as directed.
S&F Foot valve, ISI marked,80 mm dia flanged end lift type with brass strainer,suitable flanges,gaskets,bolts,nuts and washers complete all as directed.
Supply and fix 2 core 1.5 sqmm FRLS armoured copper cable as per IS:1554 to wall/ roof/ false ceiling/ floors with necessary clamps/ saddles all as specified and directed.
Supply, install test and commisioning of water cooler electric driven (single phase) having faster cooling,eco friendly refrigerent compact space saving design,speedy drainage, stainles steel tank,adjustable legs for easy leveling,automatically control temperature, having storage capacity of 80 litre and nominal cooling capacity of 40 Litres per hour complete all as directed by Eng-in-charge. Make: Voltas/Usha/ Blue star as approved by GE
S&F Voltage stabilizer of capacity 2 KVA for automatic operation, single phase naturally air cooled indoor wall mounting type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% with output voltage cut off protection with time delay relay device complete for 80 Ltrs capacity water cooler as directed by Eng-in-charge. Make: Microtek/ V-Guard as approved by GE.
Supply, install and commission hi wall split AC units indoor / outdoor, electric driven,single phase,50 Hz,240 V, inverter type with rotary compressor and refrigerant type R,complete with in built invertor,LCD cordless remote control unit, timer and with in built air ioniser and plasma filter for better indoor air quality with minimum 5 star rating of capacity 2 TR complete all as directed. Make : M/s Blue star/ Carrier Llyod as approved by GE.
Supply, install and commission hi wall split AC units indoor / outdoor, electric driven,single phase,50 Hz,240 V, inverter type with rotary compressor and refrigerant type R,complete with in built invertor,LCD cordless remote control unit, timer and with in built air ioniser and plasma filter for better indoor air quality with minimum 5 star rating of capacity 1.50 TR complete all as directed. Make : M/s Blue star/ Carrier Llyod as approved by GE.
Supply, install and commission voltage stabilizer , 5 KVA single phase , automatic operation, naturally air cooled , indoor wall mounting type ,designed for input variation between 170 V to 250 V , with output voltage stabilized at 230 V with accuracy of (+) or (-) 2.5%, with low & High Voltage cut-off protection and built in thermal overload protection , with time delay relay device , complete suitable for Split- AC, complete all as directed. Make: Cat No VND- 500 of V-Guard or equivalent model of Microtek / Matrix as approved by GE.
All as per Item No.69 above but 4 KVA.
S&F Single pole and netural enclosure with two pin and earth plug and socket complete with one single pole MCB 240 volt 20 Amp complete all as specified. Make : Havells / Standard / C&S
Schedule "A" Part - XVI: [Arboriculture] Excavation and removing top 30 cm soil and filling with sweet earth, cow dung and M&L for Korean grass carpet by piece turfing ready made of approved quality turfing side by side without undulations and depressions and ramming the surface all as per gardening practice complete all as specified and directed. Note : Supply only sweet earth and cow dung shall be measured and paid for separately under relevant items.
Digging out pit of size 300x300x300 mm in any type of soil and removing excavated soil and filling the pit with suitable growing media like red earth by treating with farm yard manure in the ratio of 3:1, fertilizers and pesticides (i.e Bavitin, Neem cake, BHC 10% linson dust, thimment or phorate, super vermi compost) and making up the trench area to proper levels and supply and planting Ashoka plant by regular watering and weeding etc complete all as directed.
All as per Item No.73 above but Royal palm tree
S&F Plantation of crotons and hedges of minimum height 30 cm with suitable growing media like red earth by treating with farm yard manure in the ratio of 3:1, fertilizers and pesticides (i.e Bavitin, Neem cake, BHC 10% linson dust, thimment or phorate, super vermi compost) complete all as directed .
Supply only sweet earth best quality suitable for plantation and carpet grass complete all as specified and directed.
Supply only bio organic manure well decomposed semi dry cow dung complete all as specified and directed.
Supply only approved vermin compost of best quality complete all as specified and directed.
S&F 16 mm bore (Outer dia) 3 layer PP-R (Polypropylene random copolymer) pipes SDR 7.4 (PN16) SDR 11 UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including PP-R plain&brass threaded polypropylene random fittings laid in trenches complete all as specified and as directed.
S&F 32 mm bore (Outer dia) 3 layer PP-R (Polypropylene random copolymer) pipes SDR 7.4 (PN16) SDR 11 UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including PP-R plain&brass threaded polypropylene random fittings laid in trenches complete all as specified and as directed.
S&F 15 mm dia,water sprinklers made brass with necessary sprinkling articles and fixed complete all as specified and directed by Eng-in-charge.
Schedule " A" Part-XVII (Maintenance of Arboricluture) M&L for Maintaining the carpet grass and plants for Item Nos.72 to 75 of BOQ by watering twice in a day, spraying fertilizer, weeding, gap filling with skilled labour complete as directed for a period of one year from the certified date of completion of schedule " A" Part-I to XVI.
S R CONSTRUCTIONS
S A R CONSTRUCTIONS
CIVILEC ENGINEERING WORKS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.08 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .