Executive Engineer
Executive Engineer, D.W.and S.Division Ranchi West Ranchi
Government of Jharkhand through its Public Works Department (PWD) is engaged in framing / revision of Schedule of Rates and as part of this endeavor, quotations through e-tender are invited for rate of items / materials annexed as Annexure-1 .
2026_DWSD_116015_1
02/CDO/Ranchi/SOR/2026-27(3rd Call)
Open Tender
Miscellaneous Services
Item Rate
30 days
Ranchi
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
Exempted
9 Jul 2026
9 Jul 2026
17 Jul 2026
9 Jul 2026
16 Jul 2026
9 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Solar Photovoltaic (SPV) Solar Submersible D.C. Water Motor Pump | - | - | - | - |
| 2 | Designing, Supplying, Installation, Testing & Commissioning with all tools & Parts of following Solar Photovoltaic (SPV) Solar Submersible D.C. Water Motor Pump Suitable for minimum 125mm x 115mm bore well as per MNRE Guideline with following specifications & accessories. | - | - | - | - |
| 3 | SPV arrays contains specified No of same capacity type & specification modules connected to series or parallel to obtained the required voltage & current the power output of individual PV modules should be minimum 200 watt peak. | - | - | - | - |
| 4 | i) The SPV modules should be as per IEC-61215 and IEC 61730 part 1.0) | - | - | - | - |
| 5 | ii) All external parts of motor pump used in submersible pump which are in contact of water is stainless steel grade 303 or higher as required. | - | - | - | - |
| 6 | iii) The PV modules should be mounted on metallic structure of adequate strength and appropriate design which can withstand load of modules & High wind pressure up to 200Km/h. | - | - | - | - |
| 7 | iv) The module mounting structure should be hot dip galvanized according to IS 4759. | - | - | - | - |
| 8 | v) To enhance the performance of SPV water pumping system & arrangement for seasonal tilt angle Adjustment should be provided | - | - | - | - |
| 9 | vi) Necessary arrangement should be provided in controller automatic start-run-stop through out the day with water level detection system. (As per MNRE Specification) | - | - | - | - |
| 10 | vii) Necessary protection such as lightening arrestor etc. should be provided to protect the controller & SPV | - | - | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.29 MB
Term.pdf
Tender Documents • 0.27 MB
Annexure-1.pdf
Tender Documents • 0.77 MB
BOQ_156843.xls
BOQ • 0.44 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .