S/F of LED Street Light 50 Nos., High Mast LED Flood Light 40 Nos. and S/F of Steel Tubular Pole 8 No. and Rewiring of Internal Electri.in Sachiv Awas and Rewiring of Internal Electrification in DDC Office at NMY Naubasta.
2026_RKUMP_1208035_1
E/M/325/2026-647
Open Tender
Electrical Works
Percentage
90 days
NMY Naubasta.
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,800
DDEM Mandi Parisad Lucknow
₹79,000
18 Nov 2026
18 Nov 2026
11 Dec 2026
18 Nov 2026
10 Dec 2026
18 Nov 2026
90 days
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supplying, Installation, Testing & Commissioning of 120watt LED Street light fixture, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. as required complete in all respect. | 50 | Nos. | 2,978 | ₹1,48,900 |
| 2 | Supplying, Installation, Testing & Commissioning of 200W LED Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI>70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirement, suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K /4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. as required complete in all respect. | 32 | Nos. | 4,031 | ₹1,28,992 |
| 3 | Supply and fixing of steel tubular pole 9.50 Meter long designated 410 SP-36 in 1:3:6 cement concrete foundation including excavation back filling etc. complete in all respects. | 8 | Nos. | 14,028 | ₹1,12,224 |
| 4 | Supply and fixing of 100 mm x 110 mm shackle insulator / 100 x 80 mm pin insulator including G.I. bolts spindle nuts etc. complete in all respects. | 8 | Nos. | 79 | ₹632 |
| 5 | S/F of 32 mm dia X 2.00 metres long G.I. pipe (medium class) bracket for mounting of fluorescent / HPMV / HPSV street light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required complete in all respect. | 50 | Nos. | 1,206 | ₹60,300 |
| 6 | Supply/Errection of ‘D’ clamps of 50 mm x 6 mm flat iron on steel tubular poles/steel rail poles with bolts, nuts etc. complete in all respects including painting with aluminum paint. | 8 | Nos. | 223 | ₹1,784 |
| 7 | Dismentling of old Steel Tubular Pole complete in all respects including painting with aluminum paint. | 8 | Nos. | 1,299 | ₹10,392 |
| 8 | Painting of the electric pole with 2 coats of aluminum paint over red oxide primer complete in all respects. | 140 | Nos. | 324 | ₹45,360 |
| 9 | Supply and erection of stay set at least 3.5 Meters away from the pole complete with galvanized 19 mm dia x 1.80 Meter long stay rod, 30cm x 30 cm x 6.3mm anchor plate, thimble stay clamps, stay insulator 19mmx600mm double screw tightener , 7/3.15mm G.I. stay wire etc. in 1:3:6: cement concrete in all respects. | 10 | Nos. | 3,029 | ₹30,290 |
| 10 | Labour charge for Lowering and Rising of High Mast Light 16.00 Meter etc. work complete in all respect. | 6 | No. | 6,508 | ₹39,048 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 3.21 MB
647TNotewithT1.pdf
Tender Documents • 3.19 MB
BOQ_2297593.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .