Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.4 LAccepted-AOC 121004 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹27.2 L+₹2.1 L (8.48%)Rejected-Finance DOOR NO 3 79 CHENNNADGRAMAPANCHAYAT PERUMBALA KASARAGOD 681317 | PERUMBALA | KASARAGOD | KERALA | 681317 | L2 | Rejected-Finance Other than lowest tenderer | |
| 3 | L3₹27.6 L+₹2.6 L (10.2%)Rejected-Finance DOOR NO IV 400 NEAR RAMANTHALI GHSS RAMANTHALI PO KANNUR 670308 | KANNUR | KERALA | 670308 | L3 | Rejected-Finance Other than lowest tenderer | |
| 4 | L4₹29.8 L+₹4.8 L (19.1%)Rejected-Finance JJ BHAVAN TC 10 1378 2 GN 31 CHENCHERY ROAD NALACHIRA PO TRIVANDRUM 695 015 | TRIVANDRUM | THIRUVANANTHAPURAM | KERALA | 695015 | L4 | Rejected-Finance Other than lowest tenderer | |
| 5 | L5₹31.1 L+₹6.0 L (24.1%)Rejected-Finance | L5 | Rejected-Finance Other than lowest tenderer |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
18 Mar 2024, 6:00 pmClosed
GE(MAINT)EZHIMALA
GARRISON ENGINEER (MAINT) MILITARY ENGINEER SERVICES INDIAN NAVAL ACADEMY POST KANNUR DIST KERALA 670 310
AS PER BOQ AND TENDER DOCUMENTS
2024_MES_643495_1
GE MAINT EZHIMALA 8623
Open Tender
Civil Works
Item Rate
270 days
EZHIMALA
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE MAINT EZHIMALA
₹70,000
Yes
20 May 2024
21 Feb 2024
20 Mar 2024
21 Feb 2024
18 Mar 2024
6 Mar 2024
22 Feb 2024 - 29 Feb 2024
Amount
Taking down the unserviceable LT UG cable of size 95 to 300 sqmm 3.5 core/ 04 core including removing electrical connection, keeping side serviceable cable, removing cable protection cover etc complete all as specified and as directed.
All as per item No.01 above but size up to 70 sqmm complete all as specified and as directed.
Exacavation in trenches not exceeding 1.5 mtr in width and depth and getting out in hard/dense soil complete all as specified and as directed. Note:- a) For all items involving excavation work contractor has to obtain prior approval from station HQ to avoid loss of other co existing utility services, in case of damage to any property he would be liable for its rectification. b)The excavation has to be done manually only.
Returning and filling in including levelling watering and well ramming into layers not exceeding 25 cm thick in hard/dense soil complete all as specified and as directed.
Removal of excavated soil to a distance not exceeding 50 mtrs and depositing at a level not exceeding 1.5 mtr from starting point complete all as specified and as directed.
Supply and spreading riddled earth for cushioning of the UG cable in trenches complete all as specified and directed by Engr-in-charge. Note:- Punned thickness shall be measured for payment purpose.
Supply and lay PCC un reinforced cable cover of size 250mmx 150mmx40mm, class LV type I flat for cable protection complete all as specified and as directed.
Relaying of PCC un reinforced LT cable cover of size 250 mmx 150mmx40mm item obtained from ser no 01 & 02 complete all as specified and directed by Engr in charge.
Supply and laying LT cable in trench/fixing to walls/pipe/pole with proper saddles, lugs, glands XLPE insulated heavy duly galvanised steel strip armoured LT 1100 volt grade with aluminium conductors of size 300 sqmm 3.5 core complete all as specified and directed by Engr-in-charge.
All as per item No.09 above but size of 150 sqmm 3.5 core complete all as specified and as directed.
All as per item No.09 above but size of 120 sqmm 3.5 core complete all as specified and as directed.
All as per item No.09 above but size of 95 sqmm 3.5 core complete all as specified and as directed.
All as per item No.09 above but size of 70 sqmm 3.5 core complete all as specified and as directed.
All as per item No.09 above but size of 50 sqmm 3.5 core complete all as specified and as directed.
All as per item No.09 above but size of 35 sqmm 3.5 core complete all as specified and as directed.
All as per item No.09 above but size of 25 sqmm 3.5 core complete all as specified and as directed.
All as per item No.09 above but size of 16 sqmm 4.0 core complete all as specified and as directed.
All as per item No.09 above but size of 10 sqmm 4.0 core complete all as specified and as directed.
Relaying cable obtained from taking out in trench/fixing to walls/ pipe/pole with proper saddles, XLPE insulated heavy duly galvanised steel strip armoured LT cable of size upto 70Sqmm 3.5/4 core complete all as specified and as directed.
Relaying cable obtained from taking out in trench/fixing to walls/ pipe/pole with proper saddles, XLPE insulated heavy duly galvanised steel strip armoured LT cable of size above 70Sqmm 3.5/4 core complete all as specified and as directed.
Supply and fix in replacement of route indicator for marking of UG cable of any size with cast iron round plate not less than 100 mm dia suitably fitted on iron and embeded with PCC block of size 30 cm x 30 cm x 45 cm complete all as specified and directed by Engr-in-charge.
Supply and fix in replacement of bus bar chamber 4 way outdoor type of size 90cmx60cmx45cm, made out of 3mm thick MS sheet with 630 Amp rated aluminium busbar (TP&N) with necessary insulators mounted on 25x25x6mm thick angle iron legs fixed in PCC foundation 1:4:8 type D2 complete all as specified and as directed by Engr-in-charge.
Supply and fix in replacement of bus bar chamber 4 way outdoor type of size 90cmx60cmx45cm, made out of 3mm thick MS sheet with 400 Amp rated aluminium busbar (TP&N) with necessary insulators mounted on 25x25x6mm thick angle iron legs fixed in PCC foundation 1:4:8 type D2 complete all as specified and as directed by Engr-in-charge.
M&L for cutting the existing road/hard standing made of concrete or premix carpet, WBM, soling and moorum filling including excavating for laying the cable/pipe, width 0.5 mtr and depth 0.7 mtr all as directed and making good the road/hard using premix bituminous as required at site to match with the existing surface complete all as specified and directed by Engr-in-charge. Note:- Before using the hand drilling/ breaker machine diamond cutter will be used all as directed by Engr-in-charge.
Supply and fix in replacement of GI tubing light grade 50 mm nominal dia including taking down in trench/road/pole for cable protection complete all as specified and as directed by Engr-in-charge.
All as per item No.25 above but size of 80 mm nominal dia complete all as specified and as directed by Engr-in-charge.
M&L for jointing LT Straight through joint kit 1100 volt out door type, of size upto 70 Sqmm 3.5/4 core complete all as specified and as directed by Engr-in-charge.
M&L for jointing LT straight through joint kit 1100 volt, size up to 120 Sqmm 3.5/4 core complete all as specified and directed by Engr-in-charge.
M&L for jointing LT straight through joint kit 1100 volt, size above 120 Sqmm 3.5/4 core complete all as specified and directed by Engr-in-charge.
Supply and fix in replacement of MCB 63 Amps TPN 240/415 Volts, 'C' curve complete all as specified and directed by Engr-in-charge.
Supply and fix in replacement of MCB 40 Amps TPN 240/415 Volts, 'C' curve complete all as specified and directed by Engr-in-charge.
Supply and fix in replacement of MCCB 100 Amp 16 KA /415volt rating/415volt TPN fixed thermal rating complete all as specified and directed by Engr-in-charge. Note:- MCCB frame size should be as per ground requirement.
Supply and fix in replacement of MCCB 160 Amp 25 KA /415volt rating four pole fixed thermal rating complete all as specified and directed by Engr-in-charge. Note:- MCCB frame size should be as per ground requirement.
Supply and fix in replacement of MCCB 250 Amp 25 KA/415volt rating four pole fixed thermal rating complete all as specified and directed by Engr-in-charge. Note:- MCCB frame size should be as per ground requirement.
Supply and fix in replacement of MCCB 320/350 Amp 25 KA/ 415volt rating four pole fixed thermal rating complete all as specified and directed by Engr-in-charge. Note:- MCCB frame size should be as per ground requirement.
Supply and fix in replacement of MCCB 400Amp 36 KA/415volt rating four pole fixed thermal rating complete all as specified and directed by Engr-in-charge. Note:- MCCB frame size should be as per ground requirement.
M&L for painting of LT panel board outdoor/indoor of any size using approved shade including welding of minor patches and holes and scrapping out the old paint from existing surface as per site requirement complete all as specified and directed by Engr in charge.
M&L for cleaning LT panel by removing grass/creepers around the LT panel upto 1m in all side of outdoor panel of any size as per site requirement complete all as specified and directed by Engr in charge.
Supply and fix in repair/replacement of hinges, sliding door bolt of outdoor/indoor panel and applying grease on hinges and joints for outdoor/ indoor panel of any size as per site requirement complete all as specified and directed by Engr in charge.
Supply and fix in replacement of Volt meter/Amp meter of any volt complete all as specified and directed by Engr in charge.
Supply and fix in replacement of surface mounted device LED indicator (Red, green,yellow), low power consumption, surge and low voltage glow protection as per site requirement complete all as specified and directed by Engr in charge.
Supply and fix in replacement of multifunction meter VAF+PF, 3 phase 5A rating flush mounting complete all as specified and directed by Engr in charge.
KDR CONSTRUCTION
SREEKRUPA ENTERPRISES
JEETH CONSTRUCTION
TAMS ASSOCIATES
General Engineering and Constructions
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .