Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.0 LAccepted-AOC | L1 | Accepted-AOC AOC | |
| 2 | L2₹20.5 L+₹56,428.60 (2.83%)Rejected-Finance | L2 | Rejected-Finance Reject | |
| 3 | L3₹20.9 L+₹93,907.83 (4.71%)Rejected-Finance | L3 | Rejected-Finance Reject | |
| 4 | Not Admitted-Fee/PreQual/Technical DHALIWAL | TARN TARAN | PUNJAB | 143107 | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
Refer Docs
EMD Value
₹19,500
Closing Date
7 May 2022, 11:00 amClosed
Executive Engineer Jal Shakti Division Nahan
Executive Engineer Jal Shakti Division Nahan
L/J and testing of rising main of MSERW pipe 65mm dia (H/M), Providing and installation and commissioning of centrifugal pumping machinery with allied accessories) Job No. 2.
2022_HPIPH_60197_1
NHN-SMROO-722- 1028-1108 dated 30-04-2022
Open Tender
Pumps/Motors
Item Rate
90 days
Nahan
Please refer Tender documents.
12 documents required · 12 mandatory
₹250
Executive Engineer Jal Shakti Division Nahan
₹19,500
Yes
31 Jan 2023
2 May 2022
7 May 2022
2 May 2022
7 May 2022
2 May 2022
Amount
Rising main
Excavation in drains and channels etc.in earth work for pipes up to all depths in all classification of earthwork such as pick work, jumper work, saturated soil including bailing or pumping out water, blasting soft/hard rock or chiseling soft / hard rock where blasting is prohibited in all lifts including jungle clearance wherever required, trimming & dressing of sides, leveling of beds to correct grade including shoring/struting, planking, timbering & dewatering wherever required stacking the useable/unuseable material/soil seperately & after laying, jointing & testing of pipes, returning the useable soil in trenches in 15 cm layers including consolidating of such deposited layer by ramming & watering & then disposing of all surplus excavated soil/unuseable material as directed with in all leads & lifts including restoration of un-metalled surfaces to its original condition & including cost of diversion for traffic, night signals, fixing caution boards, crossing over trenches for access to houses, fencing etc. complete in all respects with-in all leads & lifts as per directions of the Engineer Incharge .
Laying, jointing ,testing and commissioning at site in trenches following plain ended GMS pipes of heavy gradE as under confiriming to BIS 1239 (part-1) 1990 or latest with upto date ammendments capable of with stading requierd test pressure as prescribed in BIS code in randum lenghts of 5.5 to 6.50 mtr the pipes ends shall be bevelled suitaible for butt weld including the cost of jointing with butt welding conforming to IS 816-1969 or latest as aplicable (leak proof) in three layers at site of work with welding rods of standard make and all allied accessories whatever requried for welding at site tail pieces tees bends manufatured from parent pipes etc, and cutting of pipes whatevev required as pr site requirment including carriage all leads and lifts as directed by the Engineer Incharge (Earth wook shall be measured & paid for seprately ).
Sr No From To Dia Length in Mtr
Swara Nadasi Side
Chiya Side
Providing, welding and fixing M.S. plate flanges of various dia (nominal bore) of following Flange Tables confirming to IS 6392-1971 or latest with up to date ammendments to MSERW/G.I Pipe AFTER EVERY 90 METERS or as per site requirement including cutting of of pipes wherever required, welding in three layers (leak proof) confirming to specifications as prescribed in relvent I.S. Code i.e. IS 816-1969 or latest as applicable with up to date ammendments with nuts, bolts & washers & specials etc. confirming to IS-1963 or latest with up to date ammendments including packing sheet i.e. asbestos fibre sheet minimum 3mm thick and painting with anticorosive paints complete in all respect including all leads and lifts and as per entire satisfaction of Engineer - in - charge.
Swara Nadasi Side
Chiya Side
Chiya Side
(Centrifugal Pumping Machenery)
Supply, erection, testing & commissioning of horizontal spindle,horizontal split casing,radial split Single,/Multistages centrifugal pumps of KSB/ Mather & Platt/ Jyoti/ Kiroskar /Beaconweir/ BS & BE make pump conforming to BIS 1520-1980 with upto date ammendments read with BIS 9137-1978 or latest edition to handle clear water, having characteristics as mentioned below in Item No. 4(A), with impelleres,casing ring, priming funnels & shaft sleeves of bronze, shaft of steel with cast iron casing of suitable capacity coupled directly through a flexible coupling on a common base plate of cast steel /Mild steel to BHEL /Kirlokar/ NGEF/ Crompton / Siemen/Jyoti /GEC make slip ring /squirrel cage screen protected drip proof induction electric motor suitable for operation on the data given below i/c the cost of all the accessories in all leads and lifts & carriage of material at the site as per directions of Engineer-in-charge.
Total Head:- 227.50 Mtrs
Capacity:- 2.02 LPS
Dia of R/Main:- 65mm dia
Length of R/main:- 1800 Rmt
HP:- 2x12.50 = 25 HP
Providing and fixing of Auto control panel with push button 2 Nos star delta starter for centrifugal pumps of L&T and reputed make fabricated with M.S sheet and Angle stand duly painted and complete with internal wiring ,comprising of main switch of suitable Amp. T.P. Volt meter,copper busbar ammeter,hour run meter, phase indicating lamps with GSM based , Remote start/stop operation call/SMS for feedback regarding running of pumps & breakdown message, timer scheduling for fixed hours in a day,Inbuilt protection against overload/undervoltage,Dry run,single phase preventor,Inbuilt GPS tracker,phase reversal configurable volt/current limits with a facility to access the system through minimum 10 Nos. authenticated mobile Nos. complete in all respect, including entire carriage of materials upto all leads and lifts,installation and testing at site with entire satisfaction of Engineer-in-charge.(All meters to be installed shall be DIGITAL)
Supply &fixing at site of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader/KSB make of Cast steel double flanged sluice valve having size one size higher than the nominal delivery size of pump and capable of withstanding nominal seat pressure as mentionmed in item No. 4(a) + surge pressure & conforming to API-standards with up to date ammendments for delivery line of pump. Class of valve shall be ASA- 300.
Supply &fixing at site of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader / KSB make of suitable size cast steel double flanged swing check type reflux valve for delivery line of pump having bye pass arrangement & size one size higher than the nominal delivery size of pump and capable of withstanding nominal seat pressure as mentionmed in item No. 4(a)+ surge pressure & conforming to API-standards with up to date ammendments for delivery line of pump . Class of valve shall be ASA 300.
Supply & fixing at site of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader / Pelicon KSB make of suitable size Cast steel double flanged swing check type reflux valve confirming to API standard with up to date ammendments for R/main as mentioned in item No. 4 (c) for withstanding nominal seat pressure as per item No. 4(a) + surge pressure.The size of reflux valve shall be equal to size of Rising main and the same shall be provided with suitable bye pass arrangements. Class of valve shall be ASA 300 and shall be of 65 mm dia meter.
Supply & fixing at site of Leader/KSB/Kirloskar make cast iron double flanged sluice valve (In case Suction is +ve) for suction pipe having size one or two size larger than suction size of pump such that velocity of flow in suction pipe is not more than 3.00 mtr/sec and conforming to BIS standards with up to date ammendments. Class of valve shall be PN 1.60.
P/L & fixing of suitable size copper PVC insulated armoured power three & half core cable conforming to BIS 1554 (Part I) -1988 or latest with up to date ammendments of Siemen/Gloster/ ICC/EICO /National /IEC make from meter of HPSEB to circuit breaker & from circuit breaker to bus bar switch & starter (one cable carrying all three phases) including all other electrical equipment/accessories such as thimbles,flexible pipe,solder,nuts & bolts,cable glands etc. laid in pipes or trenches under floor. The type,size & make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.
P/L & fixing of suitable size copper PVC insulated armoured power three core cable conforming to BIS 1554 (part I)-1988 or latest with up to date ammendments of Siemen/ Gloster /ICC/ EICO/National / IEC make from switch to starter & starter to motor (one cable carrying all three phases) including all other electrical equipment /accesories such as thimbles,flexible pipes, solder,nuts & bolts,cable glands etc. laid in pipes or trenches under floor.The type,size & make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.
P/L & fixing of double loop earthing with copper plate 600x600x3mm thick electrode complete with material such as charcoal, common salt ,GI pipes,thimbles,nuts & bolts,digging of pits,GI wiring & 25x5 mm copper strips of required capacity conforming to BIS 3043-1987 latest with up to date ammendments suitable for above motors & other electrical equipments.
Supply & fixing errection of floor/wall mounted power factor shunt capacitor conforming to BIS 2834-1986 or latest with upto date ammendments of BHEL/GEC/Machneil/ Mager/Bajaj/L&T make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually,of required KVAR according to HP of motor offered including cable Siemens/Gloster/ICC make from busbar chamber to capacitor & also including L&T//Kilburn/Standard/Siemen/Havells make ICTP switches conforming to BIS 4064-1978 or latest with HRC fuses (Range to be specified by the tenderer).
Supply & fixing of 100mm dia circular dial pressure gauge of suitable range & standard make such as Fiebeg/Bourden/ Precision/PREGA with all accessories such as stop cock,copper tubing etc. conforming to BIS 3624-1987 or latest with up to date ammendments.
P/F double flanged suction, delivery pipe & common header of GMS pipe (H) considering site requirements, NPSH required & available & common header having area equal to two times the area of delivery branch of pump including tapers,flanges,rubber gaskets 3mm thick as per BIS-2712-1978 nuts & bolts as per 1364-1983 & special up to 5 mtrs. away from the outer wall of pump house as per layout drawings approved by Engineer-in-Charge. The pipes shall be capable of withstanding 1.5 times the total presure indicated in item no. 4 (E)-(ii). The size of suction pipe shall be one or two sizes larger than the suction size of pump such that valocity of flow in suction pipe is not more than 3.00 mtr/sec & delivery pipe shall be of size one size larger than nominal delivery size of pump .Thickness of GMS pipe 65 mm dia shall be 4.50 mm with flanged joint of FT- 17 .
(Centrifugal Pumping Machenery) (Swara Nadasi Side)
Supply, erection, testing & commissioning of horizontal spindle,horizontal split casing,radial split Single,/Multistages centrifugal pumps of KSB/ Mather & Platt/ Jyoti/ Kiroskar /Beaconweir/ BS & BE make pump conforming to BIS 1520-1980 with upto date ammendments read with BIS 9137-1978 or latest edition to handle clear water, having characteristics as mentioned below in Item No. 10(A), with impelleres,casing ring, priming funnels & shaft sleeves of bronze, shaft of steel with cast iron casing of suitable capacity coupled directly through a flexible coupling on a common base plate of cast steel /Mild steel to BHEL /Kirlokar/ NGEF/ Crompton / Siemen/Jyoti /GEC make slip ring /squirrel cage screen protected drip proof induction electric motor suitable for operation on the data given below i/c the cost of all the accessories in all leads and lifts & carriage of material at the site as per directions of Engineer-in-charge.
Total Head:- 198 mtrs
Capacity:- 2.42 LPS
Dia of R/Main65mm dia
Length of R/main:- 650 Rmt
HP:- 2x12.50 = 25 HP
Providing and fixing of Auto control panel with push button 2 Nos star delta starter for centrifugal pumps of L&T and reputed make fabricated with M.S sheet and Angle stand duly painted and complete with internal wiring ,comprising of main switch of suitable Amp. T.P. Volt meter,copper busbar ammeter,hour run meter, phase indicating lamps with GSM based , Remote start/stop operation call/SMS for feedback regarding running of pumps & breakdown message, timer scheduling for fixed hours in a day,Inbuilt protection against overload/undervoltage,Dry run,single phase preventor,Inbuilt GPS tracker,phase reversal configurable volt/current limits with a facility to access the system through minimum 10 Nos. authenticated mobile Nos. complete in all respect, including entire carriage of materials upto all leads and lifts,installation and testing at site with entire satisfaction of Engineer-in-charge.(All meters to be installed shall be DIGITAL)
Supply &fixing at site of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader/KSB make of Cast steel double flanged sluice valve having size one size higher than the nominal delivery size of pump and capable of withstanding nominal seat pressure as mentionmed in item No. 10(a) + surge pressure & conforming to API-standards with up to date ammendments for delivery line of pump. Class of valve shall be ASA- 300.
Supply &fixing at site of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader / KSB make of suitable size cast steel double flanged swing check type reflux valve for delivery line of pump having bye pass arrangement & size one size higher than the nominal delivery size of pump and capable of withstanding nominal seat pressure as mentionmed in item No. 10(a)+ surge pressure & conforming to API-standards with up to date ammendments for delivery line of pump . Class of valve shall be ASA 300.
Supply & fixing at site of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader / Pelicon KSB make of suitable size Cast steel double flanged swing check type reflux valve confirming to API standard with up to date ammendments for R/main as mentioned in item No. 10 (c) for withstanding nominal seat pressure as per item No. 10(a) + surge pressure.The size of reflux valve shall be equal to size of Rising main and the same shall be provided with suitable bye pass arrangements. Class of valve shall be ASA 300 and shall be of 65 mm dia meter.
Supply & fixing at site of Leader/KSB/Kirloskar make cast iron double flanged sluice valve (In case Suction is +ve) for suction pipe having size one or two size larger than suction size of pump such that velocity of flow in suction pipe is not more than 3.00 mtr/sec and conforming to BIS standards with up to date ammendments. Class of valve shall be PN 1.60.
P/L & fixing of suitable size copper PVC insulated armoured power three & half core cable conforming to BIS 1554 (Part I) -1988 or latest with up to date ammendments of Siemen/Gloster/ ICC/EICO /National /IEC make from meter of HPSEB to circuit breaker & from circuit breaker to bus bar switch & starter (one cable carrying all three phases) including all other electrical equipment/accessories such as thimbles,flexible pipe,solder,nuts & bolts,cable glands etc. laid in pipes or trenches under floor. The type,size & make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.
P/L & fixing of suitable size copper PVC insulated armoured power three core cable conforming to BIS 1554 (part I)-1988 or latest with up to date ammendments of Siemen/ Gloster /ICC/ EICO/National / IEC make from switch to starter & starter to motor (one cable carrying all three phases) including all other electrical equipment /accesories such as thimbles,flexible pipes, solder,nuts & bolts,cable glands etc. laid in pipes or trenches under floor.The type,size & make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.
P/L & fixing of double loop earthing with copper plate 600x600x3mm thick electrode complete with material such as charcoal, common salt ,GI pipes,thimbles,nuts & bolts,digging of pits,GI wiring & 25x5 mm copper strips of required capacity conforming to BIS 3043-1987 latest with up to date ammendments suitable for above motors & other electrical equipments.
Supply & fixing errection of floor/wall mounted power factor shunt capacitor conforming to BIS 2834-1986 or latest with upto date ammendments of BHEL/GEC/Machneil/ Mager/Bajaj/L&T make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually,of required KVAR according to HP of motor offered including cable Siemens/Gloster/ICC make from busbar chamber to capacitor & also including L&T//Kilburn/Standard/Siemen/Havells make ICTP switches conforming to BIS 4064-1978 or latest with HRC fuses (Range to be specified by the tenderer).
Supply & fixing of 100mm dia circular dial pressure gauge of suitable range & standard make such as Fiebeg/Bourden/ Precision/PREGA with all accessories such as stop cock,copper tubing etc. conforming to BIS 3624-1987 or latest with up to date ammendments.
P/F double flanged suction, delivery pipe & common header of G.I. pipe (MG) considering site requirements, NPSH required & available & common header having area equal to two times the area of delivery branch of pump including tapers,flanges,rubber gaskets 3mm thick as per BIS-2712-1978 nuts & bolts as per 1364-1983 & special up to 5 mtrs. away from the outer wall of pump house as per layout drawings approved by Engineer-in-Charge. The pipes shall be capable of withstanding 1.5 times the total presure indicated in item no. 11 (E)-(ii). The size of suction pipe shall be one or two sizes larger than the suction size of pump such that valocity of flow in suction pipe is not more than 3.00 mtr/sec & delivery pipe shall be of size one size larger than nominal delivery size of pump . Thickness of GMS pipe shall be 4.50mm and shall be flanges with Flange table -17.
Errection of all equipments of both parts including cost of tees bends tapers and any other fittings required as per site conditions and as per direction of the Engineer Incharge.
shiv iron general engineers
Vijay Pal Singh
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .