Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.5 LAccepted-AOC HOUSE NO 102 LANE NO 4 C ANAND NAGAR BOHRI JAMMU 180002 J K | JAMMU | JAMMU AND KASHMIR | 180002 | L1 | Accepted-AOC Being lowest and reasonable | |
| 2 | L2₹19.2 L+₹1.5 L (8.57%)Rejected-Finance R O Y K PURA QAZIGUND ANANTNAG 192221 J K | ANANTNAG | JAMMU AND KASHMIR | 192221 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹28.8 L+₹11.1 L (63.0%)Rejected-Finance | L3 | Rejected-Finance Other than lowest |
Tender Value
₹18.9 L
EMD Value
₹37,740
Closing Date
21 Aug 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE KARGIL
MES OFFICE KARGIL LADAKH
GE-K-20-2023-24 - PROVN OF PERIMETER SECURITY LIGHT AROUND UNIT LOC IN KAKSAR(1000 M) AT 8 DOGRA PROVN OF INSTALLATION OF 01 X HAMAM FOR TROOPS AND SPL REPAIR TO BLDG NO T-34 OF 851 FD WKSP COY AT KARGIL STATION UNDER GE KARGIL
2023_MES_609559_1
GE/K-20/2023-24
Open Tender
Civil Works
Item Rate
180 days
KARGIL
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE KARGIL
₹37,740
19 Sept 2023
18 Jul 2023
28 Aug 2023
18 Jul 2023
21 Aug 2023
2 Aug 2023
Amount
Dismantling wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as directed.
Dismantling of timber scantling fillets, rails, posts rafters, purlins etc under 40 Sqcm, in any position as in unframed work, complete all as specified and directed by Engr-in-Charge.
S & F second clas soft wood fillets square or rectangular in section sectional area exceeding 13 sq cm and n exc 25 sq cm as in scantling secured with nails or brads complete all as specified and directed.
S & F second class softwood fillets square, rectangular or triangular in section sectional area not exceeding 3 sqcm , clean sawn, secured with nails or brads bullnosed, splayed, chamfered or rounded on one edge or face as in cover fillets, all as specified and directed.
S & F 12mm thick Prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with nails to timber frame work in ceiling or sloping portion complete all as specified and directed.
S&F second class softwood moulding as in cornices, picture rails and the like sectional area not exceeding 6 Sqcm fixed with nails complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
S&F Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. Fe 410 -W (Gde- E- 250) quality- A complete all as specified and directed.
Dismantling of plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings etc complete all as specified and directed.
S & F 0.63 mm thick galvanised, corrugated mild steel sheeting with two corrugations side lap bent to curve, with grade of zinc coating 275 fixed with L-type or J-type or cranked hook bolts in roof, wall etc complete all as specified and directed.
All as per item no 10 above but except sheeting.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) not exc. 1.5 sq. m each complete all as specified and directed.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) exc 1.5 sq. m but n exc 4 sq. m each complete all as specified and directed.
M & L for second class softwood (KAIL), plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, complete all as specified and directed by Engr-in-Charge.
S & F 35mm thick second class softwood (KAIL) Plain, framed, panelled shutters (two panels), with panels of timber flat on both sides (feather edged), or of 12mm thick veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkats complete all as specified and directed by Engr-in-Charge.
S & F second class softwood (KAIL) 35 mm thick glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats. complete all as specified.
S & F second class softwood (KAIL) 30 mm thick glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats. complete all as specified.
S & F 4 mm thick sheet glass ordinary quality and glazing with oil putty in squares n.exc 0.5 Sqm in each pane complete all as specified and directed.
S & F galvanised mild steel wire cloth, 0.56 mm nominal dia of wire and average width of aperature 1.18 mm and fixed with tinned tacks, or galvanised wire staples including etc complete all as specified.
S&F 100 mm butt hinges medium weight cold rolled mild steel fixed with screws or welded complete all as specified and directed.
S&F 75 mm butt hinges medium weight cold rolled mild steel fixed with screws or welded complete all as specified and directed.
S&F anodised aluminium barrel tower bolt extruded sections 200 mm size complete all as specified and directed.
S&F anodised aluminium barrel tower bolt extruded sections 100 mm size complete all as specified and directed.
S&F 150mm long, Aluminium handles, cast type,anodised complete all as specified and directed.
S&F Aluminium alloy, anodised, sliding door bolt 250mm long with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed.
M&L for preparing previously untreated wood and wood based material of any description over 10cm width/girth and applying two coats of synthetic enamel paint over one coat of pink primer including preparation of surface.
M&L for preparing previously untreated steel surfaces of any description over 10cm width/girth and applying two coats of synthetic enamel paint over one coat of redoxide primer including preparation of surface.
M&L for preparing old steel surfaces of any description over 10cm width/girth and applying one coats of synthetic enamel paint complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified.
M & L for colored joint free Non - skid Ceramic tiles 9 to 10mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match pointed in white or coloured cement to match including 15 mm thick screed bed or bedding layer of cement mortar (1:6) complete all as specified and directed.
Demolition of concrete of any description and in any position and removal of rocks/debris to a distance not exc 50 mts and depositing where directed at a level n exc. 1.5 m above the starting point.
M&L for plain cement concrete 1:2:4. type B-1 (using 20 mm graded aggregate) as coping complete all as specified and directed.
M & L for 40 mm thick plain cement concrete 1:2:4. type B-0 (using 12.5 mm graded aggregate) as subbase to floor tiles complete all as specified and directed.
M & L for coloured chequered cement concrete tiles 20x20x25mm thick, with grey cement and pigments, set, jointed and pointed in neat cement slurry in floors including 20 thick screed bed in CM (1:6) all as specified.
Demolition of precast concrete articles and precast concrete block walling including all quoins, arches, pillars, etc built in cement mortar of any description not other specifically provided for etc complete all as specified.
M&L for Precast cement concrete type-C-1 block masonary with solid blocks 1:3:6 (using 20mm graded crushed stone aggregate) exc. 10cm in width and setting in cement mortar (1:6), complete all as specified and directed by Engr-in-Charge.
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed.
M&L rendering 15mm thick cement plaster in cement mortor (1:4) finished even & fair without using extra cement on brick/concrete surfaces.
M&L for two coats of cement based paint on newly plastered surfaces of walls over a coat of primer including preparation of surfaces.
S&F in repair curtain rails anodised aluminium alloy chromium plated with fixing brackets, stops, rollers etc. complete all as specified.
Supply installation, testing and commissioning LT Feeder panel board dust proof,bottom cable entry plate and gland out door type cubicle panel boardsuitable for single phase factory febricated approved CPRI powder coated made out of 3.0 mm thick CRCA sheet and MS angle iron sectiom 40X40X6mm frame with front and back openable double door system with locking arragement louver and air vent gaket for netural flow of air with conopy, inner compartment made out of 2 mm the CRCA sheet duly compartmentalized for one incoming MCCB and MCB DP as outgoing with lockable arragement with alluminium bus bar single phase and neutral of capacity of 240 amp made of high strength insulated material suitable 1100 voltage all controll PVC wires shall be with 2.5 sq mm multistrand copper conductor and shall be properly bunched, tied, frerruled for proper indication all including powder coated paint, with necessary excavation and fixed on PCC foundation complete as directed by engr-in-charge with ammeter, voltmeter etc to accomedate folowing . (a) MCCB, 4 pole 100 Amps, 415 volts -1 Nos (Incoming) (b) MCB TPN 40 Amps, 230 volts - 2 Nos (outgoing)
Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistantcomplete with driver, lamp bracket with impactand corrosion management in multiple optics complete with resistant including thermal IP 65/66 protection complete.MAKE-havells/CROMPTON or eq.
M&L for bracket made out of GI pipe 40mm dia light grade 1.5 mtr duly bent in position as per site requirement and including 2 Nos and 2 set MS flat iron clamps of size 25x 4mm including Nut , bolts and washers for mounting street lights, complete all as specified.
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 10 sq. mm ,2 core nominal cross section in service connections.
S&F ACSR conductor of (weasel) 6/2.59, straching properly on insulators and binding with aluminium binding wires,jumpers including fixing on insulators on each poles in span and tightening with permissible sag in between span etc complete all as specified and as directed by Engineer-in-charge.
S&F Shackle Type, Porcelain, vitreous, white, brown or green insulator including galvanised mild steel straps, washers insulator bolts, washers and nuts, as under:insulator bolts, washers and nuts, as under: 1100 volt, height 75 mm, max dia 90 mm, section of straps 31x3 mm made of GI, dia of bolt 12 mm GI complete all as specified.
Supplying, transporting, erecting and fixing steel tubular swaged poles type 410 SP-31 (9.0 metres long) complete with cast iron base plate, finial, taper plug, bolts, nuts and screws as specified,, painting steel tubular poles exposed surfaces with aluminium paint two coats over one coat of red oxide primer and providing 300 mm wide bands (3 bands/straps with synthetic enamel paint and 2 bands with black bituminous paint) from plinth block and numbering of poles, painting embedded portion of poles with one coat of bituminous paint complete all as specified and directed.
M&L for Plain cement concrete 1:3:6 type C-2 (using 40 mm graded crushed stone aggregate) as in foundation filling and mass concrete,complete all as specified and directed by the Engr-in-Charge.
M&L for Plain cement concrete 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) as in Coping including all necessary form works filling and mass concrete,complete all as specified and directed by the Engr-in-Charge.
Supply fixing Earthing complete with galvanized steel earth plate electrode 60 cm x 60cmx6.3 mm thick, buried directly in ground vertically (earth pit not less than 2.25 m deep below ground level) with top edge of the earth plate not less than 1.5m below ground level , connected to GI strip size 32X6mm as earthling lead by means blots and nuts check nuts and washers of galvanized iron and connected to main switch board including watering arrangement with PCC chamber , MS funnel, wire gauge. CI cover with frame , 15 MM dia GI pipe light grade for protection of wire etc including necessary excavation in any type of strata , returning, filling removal of soil outside MD land ,filling of charcoal and salt complete all as shown in electrical plate No. 5 of MES Sch Part I , connected to Earthing test point all as specified and directed on testing on completion.
S&F earth continuity conductor of GI or steel wire of dia 4 mm for earthing of poles and fixed to poles propely.
Supply and laying of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with aluminium conductor, 1100 volts, grade cross sectional area 50 sq. mm 3.5 core complete all as specified.
Excavation in trenches hard and dense soil, not exceeding 1.5m wide and not exceeding 1.5m in depth; for foundation etc. or for shafts, wells, cesspits, manholes, pier holes, not exceeding 10 sqm on plan and not exceeding 1.5Mtr in depth & getting out of hard and danse soil for taking out pipe & laying of pipe & getting out for diverting of CI pipe line complete all as specified and directed.
Removal of excavated soil to distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
Returning filling in including spreading, levelling, watering and well remming in layers not exceeding 25cm thick complete all as specified.
Sand cushioning with fine sand to under ground cables in trenches/ducts in layers of 8 cm deep before laying the cable and 15 cm deep after laying and stretching the cable as specified in clause 19.75 of SSR Part-I.
Supplying and laying un-reinforced precast concrete cable cover, class LV, Type I, flat, size 250 mm x 150mm x 40mm laid dry over electric cable for protection,complete all as specified and directed by the Engr-in-Charge.
Supplying and fix GI steel tubing, light grade, 40 mm dia for xlpe cable laid along wall, under ground etc complete all as specified and directed by the Engr-in-Charge. MAKE-JINDAL/PRAKASH/TATA or equivalent.
M&L Mild steel cross arms, bracings, supports, clamps, and back plates fabricated from structural steel sections including nuts, bolts, washers , welding, bending, cold or hot , drilling holes for bolts , in any shape or size as indicated or directed and inclusive of one primer coat with red oxide Zn Chrome and two coats of synthetic enamel paint all as specified.Note-Size of M.S channel is (75X40)MM
M&L for taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets light fittings etc. Removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surface of walls, floors, etc complete all as specified and directed.
M&L for taking down sub main wiring or service wire of 1100 volts grade heavy duty cable PVC insulated aluminium conductor of any size complete all as specified and directed.
M&L in replacement of point wiring for light/fan/bell with FRLS cable 1.5 sqmm PVC insulated (red for phase and black for neutral) unsheathed, multi stranded copper conductor 1100 volt grade in and incl not less than 2mm thick PVC casing/caping with all accessories and 1.5 sqmm green in colour PVC multistranded, copper conductor FRLS cable for earth continuity connected to common earth dolly incl MS sunken box with 3 mm thick pre laminated hylem sheet/PVC box, surface/ flush type with 3 mm thick pre laminated hylem sheet for mounting fittings such as switches, sockets, fan regulators etc complete all as specified and directed for one light/fan /bell point controlled by one switch & making good to disturbed surface of wall etc complete all as specified and directed.
M&L in replacement of point wiring for light/fan/bell with FRLS cable 1.5 sqmm PVC insulated (red for phase and black for neutral) unsheathed, multi stranded copper conductor 1100 volt grade in and incl not less than 2mm thick PVC casing/caping with all accessories and 1.5 sqmm green in colour PVC multistranded, copper conductor FRLS cable for earth continuity connected to common earth dolly incl MS sunken box/PVC box, surface/ flush type with 3 mm thick pre laminated hylem sheet for mounting fittings such as switches, sockets, fan regulators etc,but for multi 5 pin 5 amp flush type socket outlet on same board, complete all as specified and directed.
M&L in replacement of point wiring for light/fan/bell with FRLS cable 1.5 sqmm PVC insulated (red for phase and black for neutral) unsheathed, multi stranded copper conductor 1100 volt grade in and incl not less than 2mm thick PVC casing/caping with all accessories and 1.5 sqmm green in colour PVC multistranded, copper conductor FRLS cable for earth continuity connected to common earth dolly incl MS sunken box/PVC box, surface/ flush type with 3 mm thick pre laminated hylem sheet for mounting fittings such as switches, sockets, fan regulators etc,but for multi 5 pin 5 amp flush type socket outlet on independent board, complete all as specified and directed.
M&L in replacement of point wiring for light/fan/bell with FRLS cable 2.5 sqmm PVC insulated (red for phase and black for neutral) unsheathed, multi stranded copper conductor 1100 volt grade in and incl not less than 2mm thick PVC casing/caping with all accessories and 1.5 sqmm green in colour PVC multistranded, copper conductor FRLS cable for earth continuity connected to common earth dolly incl MS sunken box/PVC box, surface/ flush type with 3 mm thick pre laminated hylem sheet for mounting fittings such as switches, sockets, fan regulators etc,but for multi 5 pin 15 amp flush type socket outlet on independent board, complete all as specified and directed.
S&F in replacement of 5 pin switch socket combination outlet flush 5 pin type 5 amps on same board and independent board complete all as specified and directed.
M&L in replacement of switch socket combination outlet 2 in 1, 3 pin, flush piano type universal 15 amps controlled by one switch on independent board complete all as specified and directed.
M&L in replacement of ceiling rose,3 phase on PVC square Blocks surface bakelite 3 terminal complete all as specified and directed.
Supply and fixing in replacement of LED lights fitting 1x 18W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete,all as specified and directed.
Supply and fixing in replacement of MCB Distribution board , 240 volts single pole and neutral ,single door, sheet steel, enclosure powder coated with 200 Amps rated busbar with neutral link, 8 ways, SPN,fixed on wall duly grouted in soild block wall or wooden board with electrical connection complete all as specified and directed.Make:- QVE Series of Havells or equivalent in Sachneinder/Anchor/Siemens/Crompton/Legrand.
Supply and fixing in replacement of amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning.(i) SPN 32 Amp
Supply and fixing in replacement of 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 6 to 32 AMP, in the MCB DB Complete with connection testing and commissioning.
Supply and fixing including dismantling of unserviceable street light bracket made out of GI pipe 25/40mm dia light grade 1.2 meter duly bent in position as per site requirement and including 2 Nos and 2 set MS flat iron clamps of suitable size complete with Nut , bolts and washers for mounting street lights, complete all as specified and directed.
S&F in replacement of 1100 volts grade heavy duty 16 sqmm 2 core flat cable PVC insulated aluminium stranded conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 01 metre apart including 4 mm suspension complete all as specified and directed.
M&L in replacement of Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6.3mm thick, buried directly in ground vertically (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 meter below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers made out of galvanised iron or steel and connected to main switch board or equipement,including watering arrangement with GI light grade 20mm bore watering pipe with funnel and wire mesh with PCC chamber.CI cover with frame,40 mm dia GI pipe light grade for protection of earthing lead etc including necessary excavation in any type of strata,returning,filling,removal of soil outside MD land,filling of charcoal and salt complete all as shown in electrical plate No.3 of MES Sch Part I,connected to Earthing test point all as specified and directed on testing on completion.Notes: Earth continuity conductor including protection pipe up to 7.5 metres from earth electrode will be include in unit rate,complete all as specified and directed.
S&F in replacement of PVC rectangular block for mounting, switches, sockets, fan regulator etc. with 3 mm thick plastic laminated sheet cover of size 100 mm x 100 mm and 50 mm deep complete all as specified and directed..Make:-Reo (Havells) or Legrand/L&T.
S&F water heater Hamam of capacity 500 litre,iron body with 1 taps outlet run by Kerosen/Diesal/ electric driven blower of suitable size Modal No.WHH001 of LABORATE
M&L in replacement of point wiring for light/fan/bell with FRLS cable 4 sqmm PVC insulated (red for phase and black for neutral) unsheathed, multi stranded copper conductor 1100 volt grade in and incl not less than 2mm thick PVC casing/caping with all accessories and 2.5 sqmm green in colour PVC multistranded, copper conductor FRLS cable for earth continuity connected to common earth dolly incl MS sunken box/PVC box, surface/ flush type with 3 mm thick pre laminated hylem sheet for mounting fittings such as switches, sockets, fan regulators etc,but for multi 5 pin 15 amp flush type socket outlet on independent board, complete all as specified and directed.
Switch socket combination 2 in 1, 5 and 15 Amps flush type.
S&F Sheet metal enclosure ( single pole & neutral) with a two pin and earth plug and socket with one single pole MCB 20/25 amp Complete all as specified and directed.
S&F Sheet metal enclosure for DB's single door, single pole and neutral, 240V, 2 way with 200 Amp rated bus bar including blanking plates where required. Complete all as specified and directed.
Note :Deduction for amount of Schedule A Part - II ( Schedule of Credit) shall be made offline while awarding of contract.
M/S BHAT ENGINEERS
M/S BILAL AHMAD BHAT
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .