Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L2₹61.1 Cr+₹2.5 Cr (4.22%)Accepted-AOC KANNUR | KERALA | 670001 | L2 | Accepted-AOC Labour contract Co-operative societies are eligible price preference | |
| 2 | L1₹58.6 CrRejected-AOC MARYMATHA SQUARE ARAKKUZHA ROAD MUVATTUPUZHA ERNAKULAM DIST KERALA 686661 | MUVATTUPUZHA | ERNAKULAM | KERALA | 686661 | L1 | Rejected-AOC Labour contract Co-operative societies are eligible price preference |
Tender Value
₹62.3 Cr
EMD Value
₹5 L
Closing Date
24 Jun 2023, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Superintending Engineer
O/o the Superintending Engineer PWD Buildings SC
KLC III Construction of a Multistoried Residential Apartment at MLA Hostel after Demolishing Existing Pamba Block including Multilevel Car Parking at MLA Hostel Campus. New Pamba Block
2023_PWD_579350_1
SESCBL/94174/2023/PWD-1
Open Tender
Civil Works - Buildings
EPC Contract
900 days
Thiruvananthapuram
As mentioned in bid document
6 documents required · 6 mandatory
₹19,520
Yes
₹5 L
Yes
O/o the Chief Engineer PWD Buildings
18 Oct 2023
1 Jun 2023
27 Jun 2023
1 Jun 2023
24 Jun 2023
1 Jun 2023
8 Jun 2023
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Civil Electrical and Mechanical (a) Planning, Designing and Construction of RCC Framed Structure Building of '(C1+C2+GF+10 floors)' 13 Storeys including Preparation of Preliminary Architectural & Detailed Working Drawings, Structural Analysis & Design, Planning, Designing & Execution of all related Services including Internal Water Supply & Sanitary Installations, Internal E&M installations, Civil & Electrical External Service Connections, all E&M services , Electronics etc as per NBC 2016 including 4 no. of Lifts of required capacity by incorporating stipulated specifications, AC, Firefighting works and integrating all internal & external services pertaining to Civil, E& M with External Development works & making the facilities functional all complete as per directions of Engineer-in-Charge. The work shall be executed complete as per scope, specifications, conditions and other details stipulated in NIT/Tender document and as per direction of Engineer-in-Charge.
(b) Planning, Designing and Construction of Development Works & Bulk Services of above proposed building for Civil and E&M works including preparation of preliminary & detailed working /service drawings, structural drawings incorporating stipulated specifications and integrating all services with external development works & making the facilities functional all complete including various other development works such as internal roads, pavement, paths, water- supply system (external & internal), sewerage system, STP including relocation of existing all types of services, demolition of existing structures (if any), drainage system, roof top & surface rain water harvesting system including terrace and underground tanks of required capacity, borewell etc. complete with all related horticulture and landscape works as per scope, specifications, conditions and other details stipulated in NIT/Tender document and as per direction of Engineer-in-Charge.
(c ) Obtaining and submission of all necessary statutory approvals on completion of above proposed building work including statutory approvals on completion plans from all local authorities, obtaining fire clearance, completion certificate from all concerned local bodies or any other authorities, consent to operate, water connection, electric connection from concerned state electricity authorities, fulfilment of GRIHA / IGBC/ CPWD Green Building Norms including preparation& submission of all 'As built drawings' (on completion of entire work including obtaining occupancy certificate/ completion certificate from the local bodies) as per scope of work, conditions and other details provided in NIT/Tender document and as per direction of Engineer-in-Charge.Note:- Defect liability period of 60 months is included in the scope of above proposed building work as stipulated in the NIT/Tender document and rates to be quoted accordingly MECHANICAL WORKS
Supply, Installation , Testing and Commissioning of Multi level Car parking Facility ( 7 leves x 5 grids) along with Roof Truss work, Side cladding and Installation of Lightning arrestor Supply, Installation , Testing and Commissioning of Electro Mechanical technology to accommodate minimum of 29 Cars ( 7 leves x 5 grids) with car Carrying Capacity of 2500 kg each in all level and Car Dimensions of 5000 mm length x 2200 mm height x width 2250mm (SUV) in with average retrieval/parking time not more than 180 seconds. The Lifting speed should be at the rate of 6 Meter/Minutes and lateral movement speed of 7 M/Min having safety features as outlined in specifications with Installation of Roof truss on the top level and side covering on all levels using Aluminium sheets and with all the structural frame work designed for all probable loading conditions including loads due to roofing/cladding, , Smart Card/RFID, Branding provisions, Mechanical barriers / Boom barriers, PLC with Auto as well as Manual Mode of operation etc along with lightning arrestor and fire fighting works for approval from fire department and including Maintenance for Five year during the Defect Liability period as mentioned in tender documents Electronics Works LAN Cabling, Wi-Fi Access Connectivity
Supply, installation, testing and commissioning of 24 Port 10/25GbE SFP28 switch with 4x 100GbE QSFP28 uplinks with dual power supply (Accepted model: Cisco C9500-24YC-A or Higher),24 Port PoE+ switch with modular uplink with 24 PoE+ copper ports, minimum 2 numbers of 10G uplink ports, minimum PoE budget of 505 Watts with necessary secondary power supply(Accepted model: Cisco C9300L-24P-4XE or Higher),48 Port switch with modular uplink with 48 copper ports, minimum 2 numbers of 25G uplink ports, dual power supply (Accepted model: Cisco C9300-48T-E or Higher),24 Port switch with with 24 copper ports, minimum 2 numbers of 10G uplink ports, dual power supply(Accepted model: Cisco C9200-24T-4XE or Higher),Single Mode duplex optical transceiver, SFP+ module for 40G connectivity with a link length of 10 kilometres on standard Single-Mode Fiber (SMF, G.652) , hot- swappable and compatible with the above switches.(Accepted Model: Cisco QSFP-40G-LR4-S or Higher),Single Mode duplex optical transceiver, SFP+ module for 10/25G connectivity with a link length of 10 kilometres on standard Single-Mode Fiber (SMF, G.652) at both 10G and 25G, hot- swappable and compatible with the above switches.(Accepted Model: Cisco SFP-10/25G-LR-S or Higher),Single Mode duplex optical transceiver, SFP+ module for 10G connectivity with a link length of 10 kilometres on standard Single-Mode Fiber (SMF, G.652), hot- swappable and compatible with the above switches(Accepted Model: Cisco SFP-10G-LR-S or Higher)wireless access point with enterprise class 4x4 MIMO with four spatial streams, 802.11ac Wave 2 , data rates upto 1.7 Gbps on 5 GHz radio, integrated 24.4GHz and 5 GHz antennas, PoE supported with maximum 20.9W power draw, 1 GB RAM and 256 MB Flash memory, fully compatible with the existing Aceess point controller and supplied with necessary mounting brackets for wall mounting as required and with minimum 5 year warranty.(Accepted Model: Cisco AIR-AP1852I-D-K9 or Higher)24 Port fully loaded LIU with sliding drawer for ease of reconfiguring fibers, adhesive labelling for port identification, rack mountable with 1 RU size and with necessary SC/LC connectors including splicing charges. (Accepted Make: Molex/Actassi/Belden/Commscope), Cat6A 48 Port/24 port Enhanced Modular type fully loaded Patch Panel with spring loaded shielded connectors for interconnecting servers and clients, 2RU size including termination charges and adhesive labelling for port identification( Accepted Make: Molex/Actassi/Belden/Commscope),19 inch 22 U floor mounting rack with 4 numbers of caster wheels (2 with brakes and 2 without brakes) and 15U wall mounting rack with front glass door and back metal door, covered wire manager, cooling fan, AC distribution box as required for connecting all the active devices and all other accessories as required (Accepted Make : Netrack / Valrack),Single Mode duplex optical patch cord, SC/UPC-LC/UPC connectors as suitable for the used LIUs and modules, 2m length and with LS0H Cable Sheath Material (Accepted make: Molex/ Actassi/ Belden/ Commscope),Cat6A LSZH 1m/2m Patch Cord with 4 pair 26 AWG stranded copper wire,pre-terminated with RJ45 plugs with gold plated copper connectors, slim clear anti-snag slip on boots, PVC sheath,10G Performance when installed as a complete Power Cat 6A Shielded System and RoHS Compliant(Accepted Make: Molex/Actassi/Belden/Commscope),UL Certified dual Cat6A RJ45 modular face plate on PVC box of suitable size ,loaded with dual Cat6a RJ45 female connectors with spring shutter(Accepted Make: Molex/Actassi/Belden/Commscope),12 core Single Mode optical fibre cable in conduit/ on surface using suitable size fixtures as required(Accepted Make: Molex/R&M/Commscope),4 pair Cat6A LSZH cable through the existing conduit and with 23 AWG copper conductor, shielded pairs,10G support, LS0H sheath with different colour for primary and secondary networks (Accepted Make: Molex /Belden/R&M/ Commscope),25 mm medium PVC conduits/ casing and capping with specials confirming to ISI standard. Excavation of trench of size suitable for laying 50mm HDPE duct in ordinary soil, replacement of existing paving tiles as required and refilling the trench etc. as required for laying HDPE duct.3 KVA UPS with 6/8 numbers of 75AH SMF battery with battery racks(Accepted Make: APC, Numeric, Eaton, Delta, Emerson) Telephone Cabling-Supply and installation of MDF 100 pair, 10 pair with krone module with Box (Accepted Make: AD Krone,Best net,Krone),armoured PVC insulated and & PVC sheathed copper conductor Telephone 100 Pair, 10 Pair ,5 pair,2 pair Cables conforming to ITD specification for indoor application through the existing PVC conduits/ casing and capping etc as required. (Accepted Make: Finolex, Delton, Traco). information outlet having spring shutter / dust cover dual face plate with SMB with box, one number of RJ11 telephone jack including termination charges etc. (Accepted Make: R&M, Tyco Amp, MK), 20mm, 25mm PVC/casing and capping with special confirming to ISI standard in recess /on surface using suitable size fixtures spacing not exceeding 50cm including making the good damage colour washing etc. (Accepted Make: Toms, Balco, Espee) 50 x 50 mm PVC Cable Management System with base and lid along with all accessories conforming to IEC 61084/BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required (Accepted Make: Honeywell,OBO,Legrand), Push button Phone (Basic Phone) - Tone / Pulse switchable, Flash, Pause, Mute & Redial Facility, Ringer Volume Control (Accepted Make: Panasonic KXTS500MX / BPL / Beetel) TV Cabling-Supplying and Drawing of RG6 grade TV Co-axial cable 0.7mm Solid Copper Conductor PE insulated Shielded with fine tinned Copper Braid and protected with PVC Sheath through the existing recess conduit as required.(Accepted Make: Finolex/Traco) 4 way RF Splitter suitable for interconnecting RG6 cables(Accepted Make:MX,KINGSTON), 25 mm medium PVC conduits/ casing and capping with specials confirming to ISI standard in surface/ recess using suitable size fixtures spacing not exceeding 50 cm including making good the damage colour washing etc as required(Accepted Make: Toms/Balco/Espee). GI box along with modular base and cover plate for modular switches in recess etc as required for 1 module including face plate(Accepted Make: Legrand/L&T/Molex), Fixing 19" 6U Wall Mount Rack having 600mm depth, Fan & cable tray with general accessories including hardware mounting kit (Accepted Make: Valrack/Netrack) Public Address System-19" Rack mount Dual Channel Power Amplifier 2 X 150 Watts @ 100V / 4 Ω, Frequency Response: 20 Hz - 20 kHz, Bridge Mode 1 X 300 Watts @ 8 Ω , Class D Amp Topology ,Signal / Noise > 90 dB, Convection Cool and with 5 year warranty.(Accepted model: Audac EPA 152 /Apart /JBL/Yamaha),12-Channel Mixing Console with 6 Mic / 12 Line Inputs (4 mono + 4 stereo), 2 GROUP Buses + 1 Stereo Bus, 2 AUX (incl. FX), 1-Knob compressors, High-grade effects: SPX with 24 programs24-bit / 192kHz 2 in / 2 out USB Audio functions and with 5 year warranty.(Accepted model: Yamaha MG-12XU/Sound craft), Condenser microphone with 40 cm gooseneck with green/red LED Ring, RF shielding against intermodulation from wireless devices, frequency response: 50Hz- 20 KHz, impedance < 100Ω, working on 48V Phantom power and with microphone base suitable for the above microphone with Toggle on-off/Push to mute/Push to talk/Permanent on microphone modes and with 5 year warranty.(Accepted model: Microphone: Sennheiser MEG 14-40-L-II Base: Sennheiser MAT 153-S/Shure/Beyer dynamic). Wireless UHF microphone with base unit, Up to 10 compatible channels, Switching bandwidth up to 24 MHz, Sensitivity 1.5 mV/Pa (free field, no load at 1 kHz), Frequency response 50 - 16,000 Hz, 2-channel diversity reception, Integrated antennas Automatic frequency management and synchronization via remote channel for easy setup with all necessary cables and connectors and with 5 year warranty.(Accepted model : Sennhiser XSW1- 835,Shure/Beyer dynamic). High fidelity 2-Way speaker system with 30/60/90/tappings and necessary wall mounting bracket. (Accepted Make: JBL,Audac,Apart), Digital Voice Recorder with mp3 recording, 4GB or higher internal memory, battery operated, recording from built in microphone and stereo mic in jack, expandable storage upto 32 GB using Micro SD memory card, direct USB connectivity for file transfer between PC and device without USB cable and with 5 year warranty including necessary connecting cables.(Accepted Model: Sony CD-PX470), snake cable termination, speaker cabling...etc (12 core /16 core) (Accepted Make:Beldon,Srexact) Projector System-Multimedia projector having WUXGA resolution, supplied with wall mount kit, necessary connecting cables including HDMI, VGA and power cables (Accepted Make: Epson,BenQ),motorised projector screen suitable for the above projector with 96 inch diagonal size with all necessary accessories (Accepted Make : Liberty/Matrix), laptop computer with Intel core i5 or equivalent processor with necessary graphics card suitable for handling HD Video contents(Accepted Make:Dell, Acer), 4K HDR HDMI Repeater(Accepted Make: Kramer). 19’’ 17 U floor mounting rack with necessary power strips and shelves as required (Accepted make: Netrack, Valrack)2 KVA UPS with 2x150 AH battery for power back up for the projector and the AV equipments(Accepted Make:APC,Numeric,Eaton, Delta.Emerson), HDMI face plates, cable cubby. Etc.(Accepted Make: Kramer).
Video Conferencing System- video conferencing system including necessary camera, speakers, small form factor PC, Wi-Fi modem and with necessary monitor with diagonal size not less than 24 inches.(Accepted Make:Logitech,People Link)
Note:-Defect liability period of 60 months is included in the scope of above proposed building work as stipulated in the NIT/Tender document and rate to be quoted accordingly | 1 | Nos | 62,34,88,599 | ₹62,34,88,599 |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
BOQ_855607.xls
BOQ Document • 0.32 MB
122084938.pdf
Tender Document • 0.10 MB
Thefinalbid.pdf
Tender Document • 13.26 MB
LOT.pdf
Tender Document • 0.30 MB
EPCGCC.pdf
Tender Document • 1.68 MB
FinalAddendum.pdf
Tender Document • 9.34 MB
JVJDU.pdf
Tender Document • 2.02 MB
FormAtoG.pdf
Tender Document • 2.67 MB
122084940.html
Tender Document • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .