Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.3 LAccepted-AOC SCO 529 3RD FLOOR KESHO RAM COMPLEX SECTOR 4 C CHANDIGARH 160047 | CHANDIGARH | CHANDIGARH | CHANDIGARH | 160047 | L1 | Accepted-AOC LOA | |
| 2 | L2₹44.9 L+₹3.6 L (8.80%)Rejected-Finance 2ND FLOOR PLOT NO 338 UDHYOG VIHAR PHASE IV GURUGRAM 122015 HARYANA | GURUGRAM | HARYANA | 122015 | L2 | Rejected-Finance Highest | |
| 3 | L3₹45.4 L+₹4.1 L (9.89%)Rejected-Finance TAILOR MARKET MAIN BAZAAR MANDI ADAMPUR 125052 | HISAR | HARYANA | 125052 | L3 | Rejected-Finance Highest |
Tender Value
₹38.3 L
EMD Value
₹76,640
Closing Date
25 Jun 2024, 5:00 pmClosed
NAVEEN RATHEE
ED - Ambala
Up-gradation of Civil Hospital Naraingarh from 50 Bedded to 100 Bedded alongwith residential accommodation in Ambala District (Pdg. LAN, EPABX, and Nurse Call System).
2024_HRY_376839_1
202470E1C78F 83DB 4AF4 882B 094A12978E2B663BAR
Open Tender
Electrical Works
Works
495 days
Ambala Cantt
Up-gradation of Civil Hospital Naraingarh from 50 Bedded to 100 Bedded alongwith residential accommodation in Ambala District (Pdg. LAN, EPABX, and Nurse Call System).
2 documents required · 2 mandatory
₹5,000
₹76,640
Yes
30 Oct 2024
11 Jun 2024
26 Jun 2024
12 Jun 2024
25 Jun 2024
12 Jun 2024
Amount
[23.23.9]MISCELLANEOUS 9. Supplying and drawing of 1 no UTP 4 pair CAT 6 LAN Cable in the existing surface/recess MS/PVC conduit as required
Supply,Erection testing and Commissioning of UTP cat 6 information outlet( RED - for Data - User End) complte in all respect upto the entire satisfaction of Engineer-in-Charge of the work Make:- RandM,/Molex/D-link/Siemon/Systimax.
Supply, Erection testing and Commissioning of UTP Face plate(Single/dual) complte in all respect upto the entire satisfaction of Engineer-in-Charge of the work Make:- RandM,/Molex/D-link/Siemon/Systimax.
Supply, Erection testing and Commissioning of 3 FT length UTP cat 6 Mounting Patch Cords Low smoke zero helogene (LSZH/LS0H )complte in all respect upto the entire satisfaction of Engineer-in-Charge of the work Make:- RandM,/Molex/D-link/Siemon/Systimax.
Supply, Erection testing and Commissioning of 7 FT length UTP cat 6 Mounting Patch Cords Low smoke zero helogene (LSZH/LS0H )complte in all respect upto the entire satisfaction of Engineer-in-Charge of the work Make:- RandM,/Molex/D-link/Siemon/Systimax.
Supply, Erection testing and Commissioning of 24-port 19` 1 U jack panel which Should Be made of sheet steel 1.5 mm, Should be 19` 1U straight Patch Panel, 24-port, Should have integral cable management Metal shelf,Should accept Shielded as well as Unshielded jacks which should be toolless termination. Should have rear cable management shelf metallic powder coated. Make: RandM,/Molex/D-link/Siemon/Systimax.
Supply, Erection testing and Commissioning of Edge Switch 24 Port 10/100/1000 plus 2 1G/10 G SFP Layer 2 manageble Base T Manageble auto sense, Ethernet switch complete in all respect up to the entire satisfaction of Engineer-in charge of work . Make:CISCO/Juniper/D-link/Allied.
Supply, Erection testing and Commissioning of 12 U rack with cable manager, fan tray, power distribution kit complete in all respect.Make: HCL/Comrack/Wallrack/Netrack/D-link
Supply, Erection, testing and commissioning of 1KVA on line UPS with one hour backup complete in all respect. Make:-APC/DELTA/VERTIV/EMERSON/Microtek/Eaton
Supply, Erection, testing and commissioning of 2KVA on line UPS with 6 nos 26 AH 12V along with batteries stand comple in all respect. Make:-APC/DELTA/VERTIV/EMERSON/Microtek/Eaton
SITC of Digital Hybrid IP-PBX System configured for 04 Analog Trunk Connectivity, 4 Digital Extensions, 80 Analog Extensions. It should be possible to reach the capacity of system to 240 ports and 999 IP users without any add-on CPU or chassis/hardware platform. System should have two Gigabit Ethernet ports for LAN and WAN to separate out local and VoIP traffic on external network.It should be suitable for DTMF as well as the FSK type of telephone instruments. It should have built-in multi-party conferencing without any software , night service control etc. should be available by default. Make : Avaya/Unify/Matrix
SITC of Operator Console :SITC of Digital DSS having 32 Direct Keys compatible with the PBX and its console.With option to add multiple DSS with the console. Phone Features Message wait Lamp, Ringer Lamp. Make : Avaya/Unify/Matrix/Alcatel
SITC of Digital Phonee with large Backlit Display of 240x60 Pixels Graphic LCD, 4 Context Sensitive Keys,Built-in 16 DSS Keys,High Quality Full Duplex Speaker Phone Features Call Forward,Waiting,Transfer,Hold,Conference,Redial, Ringer Lamp.Must have storage for minimum 20 calls per call log in the console itself.Make : Avaya/Unify/Matrix/Alcatel
Supply, Erection, testing and commissioning of Push Button Telephone Desktop model CLI, flash , redial complete in all respect. Make :-Beetel
Supply and erection of 100 Pair IDF/MDF with Krone Make module on Krone Make MS Box duly painted and having lock facilities
Supply and erection of 50 Pair IDF/MDF with Krone Make module on Krone Make MS Box duly painted and having lock facilities
Supply and erection of 20 Pair IDF/MDF with Krone Make module on Krone Make MS Box duly painted and having lock facilities
Supply and Laying of multicore 20 Pair Telephone cable conductor size 0.51mm bright annealed copper conductor PVC insulated and shealed in existing pipe / Channel etc. (excluding the cost and laying of pipe / channel) and making necessary connection complete in all respect . Make:- Delton / Shalimar / Polycap/Phenolex.
Supplying, fixing testing and commissioning of Patient Convenient call module ( PCCM) for patient. The uint shall consist of:- 1 membrane keypad with:- 1 call button (red with nurse symbol) including a finder/ reassurance LED . The patient handset shall be supplied with a spiral cord of 2 mtrs for flexible extension. Makes: Reynolds / Ackerman / Omnitech (OAS)
Supplying, fixing testing and commissioning of Toilet Call Terminal (TCT) with Pull cord for WC. The unit shall consist of:- 1 call button (pull cord) including a LED indication light,- 1 call button on the unit including LED Indication.- integrated finder lights on the Unit.- micro switch with a 2 metre long pull cord. Makes: Reynolds / Ackerman / Omnitech (OAS)
Supplying, fixing testing and commissioning of microprocessor based medullar Nurses Terminal station 24 Port (NTS) with 18` HD LED Monitor terminal. The Moitor shall display customized windows layout according to the No. of the beds attached with the NTS. The window corresponding to the activated call shall change its colour along with voice message for easy and fast identification of the Calls generation. The location of the source shall start continuously rolling in customized text message form on the monitor. The NTS shall have call acknowledge facility. The terminal shall be supplied with the requisite Electronic circuit boards with controllers, CPU and Flash PROM and capability for Optional TCP/IP interface if required. The terminal shall display date and time customized background options. The NTS shall be supplied in the below mentioned capabilities. Makes: Reynolds / Ackerman / Omnitech (OAS).
Supplying, fixing testing and commissioning of Patient Nurse Assistance Terminal (NAT) consisting of a high quality polycarbonate case and the Unit shall be capable of flush mount on the patient Bed Panel or shall be wall mountable independently. The Unit shall have - Call button with integrated reassurance light indication integrated on the Unit. - Integral Membrane keypad in soft touch pad finish with integrated LEDS,for operation confirmation. The Unit shall consist of:- 1 Call keywith LED indication- 1 Call Reset Key with LED indication - 1 Code Blue key with LED Indication with specific activation sequence.It shall be supplied with all the connectors, sockets and terminals with suitable back Box for mounting. Makes: Reynolds/ Ackerman/Omnitech (OAS).
Supplying, fixing testing and commissioning of Localised visual call Identifier (LVCI) of calls, present outside the wards in the common area to indicate patient call. the unit shall consisting of:- Dual coloured LED Flashing visual indicator. The Indicator shall be housed in a suitable polycarbonate housing with surface mounting provisions. The Unit shall get activated once the call is initiated by the patient and shall get reset when the call is acknowledged by the Nurse / Nursing assistant. Makes: Reynolds/Ackerman/Omnitech (OAS).
-Supply,Errection testing and Commissioning of network communications module with 4 way RJ connectors and power supply unit housed in MS enclosure complete in all respect upto the entire satisfaction of Engineer-in-Charge of the work .Make:- Reynolds/Ackerman / Omnitech (OAS).
Supplying, fixing testing and commissioning of Nurse Call System central reporting Software. The Software pack shall be installed on the system server. The Software shall be flexible to generate the reports in a customized manner for automatically logging of all the events. The events shall be presented in a tabular format. There shall be multiple reports which can be generated based on the key requirements like Bed no. wise, date wise and time Wise. The software shall have one specialized column with time totalization record dipicting the time taken between the call generation by the Patient and the call attended. Makes: Reynolds/Ackerman/Omnitech (OAS).
Netromics Engineering Solutions Private Limited
Prime Computers
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .