Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.3 LAccepted-Finance | L1 | Accepted-Finance Qualified | |
| 2 | L2₹10.6 L+₹2.3 L (28.2%)Accepted-Finance 176 SARWAL COLONY JAMMU | L2 | Accepted-Finance Qualified | |
| 3 | L3₹10.9 L+₹2.6 L (31.1%)Accepted-Finance 11 ANUPAM VIHAR ENGINEERS ENCLAVE GMS ROAD DEHRADUN UTTARAKHAND 248001 | DEHRADUN | UTTARAKHAND | 248001 | L3 | Accepted-Finance Qualified | |
| 4 | L4₹11.0 L+₹2.7 L (32.5%)Accepted-Finance | L4 | Accepted-Finance Qualified | |
| 5 | L5₹11.5 L+₹3.2 L (38.8%)Accepted-Finance | L5 | Accepted-Finance Qualified |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
31 Aug 2024, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer Electrical JK SIDCO
Executive Engineer Electrical JK SIDCO
ANNUAL OPERATION AND MAINTENANCE OF EXISTING INFRASTRUCTURE COMPRISING OF ELECTROMECHANICAL EQUIPMENTS INTERNAL EXTERNAL ELECTRICAL SYSTEM IN JKSIDCO MANAGED INDUSTRIAL COMPLEXES OF JAMMU DIVISION
2024_SIDCO_254483_1
E-NIT No 01 of 2024 25
Open Tender
Electrical and Maintenance Works
Item Rate
jk Sidco Jammu
As per tender document
2 documents required · 2 mandatory
₹1,500
Executive Engineer Electrical JK SIDCO
₹50,000
5 Sept 2024
29 Jul 2024
2 Sept 2024
29 Jul 2024
31 Aug 2024
29 Jul 2024
Amount
Complete rewinding of following submersible Motors including rebate of old material.
5 HP Capacity
7.5 HP Capacity
10 HP Capacity
12.5HP Capacity
15 HP Capacity
17.5 HP Capacity
20 HP Capacity
22.5 HP Capacity
25 HP Capacity
Complete rewinding of horizontal Squirrel Cage Motors High Speed type including rebate of old material
5 HP Capacity
7.5 HP Capacity
10 HP Capacity
Repair to 5/7.5HP/10HP capacity motor by way of replacement of bearing at DE and NDE and assembling of motor.
Repair to 5/7.5HP/10HP capacity motor by way of welding, turning, polishing of shaft , sleeve to end covers and assembling of motor etc.
Disconnecting the electrical connection, disengaging the pump motor set from base frame , making alignment, all electrical connection and testing therof.
Loading of motor pump set into mechanical transport and carriage to workshop and unloading thereof. Loading the motor pump set into mechanical transport and carriage to site and unloading thereof by using skilled/unskilled labour and other tools and tackles
Up to 10 Km
Above 10Km upto 15Km
Loading of damaged Submersible Motor (V4) from site of work by way of head load carriage to Mechanical Transport and carriage back to site of work after repairing and unloading at site up to 10KM
Loading of damaged Submersible Motor (V6) from site of work by way of head load carriage to Mechanical Transport and carriage back to site of work after repairing and unloading at site up to 10KM
Submersible Pump V4 to V8
Disconnecting of power supply and testing of pump at site
Dismantling of submersible pump set at workshop and checking for its replacement of damaged parts.
Providing and fitting of new pump shaft
Reconditioning of pump shaft by way of welding, turning and polishing to actual size, making of key way
Providing and fitting of new cast iron impeller.
Reconditioning of impeller by way of welding, turning and polishing to the actual size.
Providing and fitting of new Neck Ring.
Providing and fitting of Shaft Sleeve.
Providing and fitting of Coupling with key
Providing and fitting of Bowl Bush
Providing and fitting of NRV Bowl.
Providing and fitting of Tee Bolts/per piece
Providing and fitting of Stud fasting ring with studs upper and lower and circlip lock.
Providing and fitting of Diffuser.
Providing and fitting of thrust bearing / thrust pad set
Assembling of Pump and then coupling with motor with proper alignment. Testing in test pit at workshop.
Providing and fitting of copper submersible cable 3 core along with thimbles
Extraction out of Submersible Motor pump set
Extraction out 2.5 inch dia to 4 inch dia column pipes from tube by way of Disconnecting of Power connections from starter panel, disengaging from delivery bend and extracting out Submersible Pump Set complete along with column pipes by hoisting chain pulley block at Tube well, stacking of column pipes and Submersible cable properly.
Column pipes 0 to 10 Nos
Column pipes 10 to 20 Nos
Lowering of Submersible Motor pump set
Lowering of 2.5 inch dia to 4 inch dia column pipes in Tube well by Making of cable connection of motor with Submersible cable after dressing cable ends properly. Making of each joint water proof. Lowering of Submersible Pump Set complete along with column pipes and submersible cable with providing & fitting of jointing material and nuts and bolts. Making of connections to the starter panel
Column pipes 0 to 10 Nos
Column pipes 10 to 20 Nos
Star Delta control panels for Submersible pump set
Disconnection of incoming Power connection from mainswitch /MCCB/Voltage Stabilizer and checking of fault. Making of temporary arrangement for running of pumping machinery
Providing and fitting of Damaged Contactor of following ratings
MNX 25 Amp
MNX 45 Amp
MNX 50 Amp
MNX 70 Amp
MNX 95 Amp
MNX 110 Amp
Providing and fitting of Damaged Kit of following rating contactors
MNX 25 Amp.
MNX 45 Amp.
MNX 50 Amp.
MNX 70 Amp.
MNX 95 Amp.
MNX 110 Amp.
Providing and fitting of Damaged coil of following rating contactors
MNX 25 Amp.
MNX 45 Amp.
MNX 50 Amp.
MNX 70 Amp.
MNX 95 Amp.
MNX 110 Amp.
Providing & Fitting of Auxiliary block
Providing & Fitting of Aluminum Bus Bar
Providing & Fitting of damaged over load relay & P/F new overload Relay
Providing & Fitting of damaged under volt relay & P/F new relay
Providing & Fitting of single phase preventer ( L&T)
Providing & Fitting of Damaged MCCB
63 Amp 4pole 16KA
100 Amp 4pole 16KA
160Amp 4pole 16KA
200 Amp 4pole 36KA
250 Amp 4pole 36KA
400 Amp 4pole 50KA
630 Amp 4pole 50KA
Making of incoming Power connection to main switch/MCCB/Servo Stabilizer and checking on full load at site
Control Star delta panel up 15 to 100 Amp.
Charges for minor repair/servicing of LT Control Panel including minor parts like meters, indicators , timers etc
Providing /fitting of circuit wiring
Providing /fitting of voltmeter Analog
Providing /fitting of amp meter Analog
Providing/ Fitting of digital Volt meter
Providing / Fitting of digital Amper meter CT operated
Providing /fitting of Push Button on/off
Providing /fitting of indicator lamps R/4/B
Providing /fitting of star delta timer
Providing /fitting of terminal plate
Providing /fitting of quartz timer
Providing /fitting of delay timerProviding /fitting of delay timer
Providing /fitting of power wiring
Providing /fitting of thermal overload relay
Providing /fitting of bus bar
Providing /fitting of fuse link
Providing /fitting of fuse holder suitable for bolted fuse link
Servo Stabilizer 25 to 50 KVA Capacity
Rewinding of copper Coil & fitting etc at site.
Providing & Fitting of Dimmer coil 60Amp.
Providing & Fitting of Change Over Switch 100 ampere
Providing & Fitting of Change Over Switch 100 ampere
Providing & Fitting of digital Control card
Providing & Fitting of carbon brushes
Providing & Fitting of moving arm
Providing & Fitting of RC circuit
Providing & Fitting of toggle switch for auto /manual
Providing & Fitting of CT 100/5A
Providing & Fitting of limit switch
Providing & Fitting of gear wheel
Providing & Fitting of Indicator
Providing & Fitting of Ampere meter
Providing & Fitting of Voltmeter
Fresh Transformer Oil per litre
Providing & Fitting of Nut Bolts
Complete power wiring with thimbling
Complete top panel wiring with thimbling
Disconnecting of power connection of the servo Stabilizer, dismantling of stabilizer by unscrewing nut bolts. Extracting out of stabilizer coil structure by mounting of chain pulley block with the help of manual skilled labour.
Distribution Transformers
63KVA Capacity Transformer
Disconnecting of distribution transformer HT links and HT/ LT side cables. Dismounting from poles/platform using crane / skilled and un-skilled labour using tools and tackles, loading in Mechanical transport and carriage to workshop and unloading at workshop. Providing and installing transformer from its own temporarily to run the station till the damaged transformer is repaired and installed where standby not available
Draining of Transformer oil in barrels, dismantling of top cover and extracting out assembly using chain pulley block and tripod and checking for fault.
Reconditioning of LV Aluminium coil per kg
Providing and fitting of HV leg coil Aluminium SE (per Kg)
Providing and fitting of HV leg coil Aluminium DPC(per Kg)
Providing and fitting of LV leg coil Aluminium DPC (per Kg)
Providing & fitting of HV bushing
Providing& fitting of LV bushing
Providing& fitting of HV bush rod (metal part)per rod
Providing& fitting of LV bush rod (metal part) per rod
Providing& fitting of gasket set
Providing& fitting of tapping switch with handle
Providing & fitting of LT terminal plate
Providing & fitting of Oil drain valve
Providing & fitting of core laminations per Kg
Providing& fitting of sundry items
Heat treatment of repaired transformer
Arresting of oil leakages if any by way of welding etc.
Painting of transformer body
Silica Gel breather
Providing & Fitting of fresh T-oil
Assembling of transformer and lowering into the tank using chain pulley block and tripod. Assembling of top cover thereof and filling of transformer oil after dehydrating.
Loading of transformer into Mechanical transport using crane / skilled and un-skilled labour using tools and tackles and carriage to the site of work (For Urban areas). Mounting the transformer on poles/ platform with the help of crane / skilled and un-skilled labour using tools and tackles after dismounting the temporarily installed transformer
100KVA Capacity Transformer
Disconnecting of distribution transformer HT links and HT/ LT side cables. Dismounting from poles/platform using crane / skilled and un-skilled labour using tools and tackles, loading in Mechanical transport and carriage to workshop and unloading at workshop. Providing and installing transformer from its own temporarily to run the station till the damaged transformer is repaired and installed where standby not available
Draining of Transformer oil in barrels, dismantling of top cover and extracting out assembly using chain pulley block and tripod and checking for fault.
Reconditioning of LV Aluminum coil per kg
Providing and fitting of HV leg coil Aluminium SE (per Kg)
Providing and fitting of HV leg coil Aluminium DPC(per Kg)
Providing and fitting of LV leg coil Aluminium DPC (per Kg)
Providing & fitting of HV bushing
Providing& fitting of LV bushing
Providing& fitting of HV bush rod (metal part)per rod
Providing& fitting of LV bush rod (metal part) per rod
Providing& fitting of gasket set
Providing& fitting of tapping switch with handle
Providing & fitting of LT terminal plate
Providing & fitting of Oil drain valve
Providing & fitting of core laminations per Kg
Providing& fitting of sundry items
Heat treatment of repaired transformer
Arresting of oil leakages if any by way of welding etc.
Painting of transformer body
Silica Gel breather
Providing & Fitting of fresh T-oil
Assembling of transformer and lowering into the tank using chain pulley block and tripod. Assembling of top cover thereof and filling of transformer oil after dehydrating.
Loading of transformer into Mechanical transport using crane / skilled and un-skilled labour using tools and tackles and carriage to the site of work (For Urban areas). Mounting the transformer on poles/ platform with the help of crane / skilled and un-skilled labour using tools and tackles after dismounting the temporarily installed transformer
250KVA Capacity Transformer
Disconnecting of distribution transformer HT links and HT/ LT side cables. Dismounting from poles/platform using crane / skilled and un-skilled labour using tools and tackles, loading in Mechanical transport and carriage to workshop and unloading at workshop. Providing and installing transformer from its own temporarily to run the station till the damaged transformer is repaired and installed where standby not available
Draining of Transformer oil in barrels, dismantling of top cover and extracting out assembly using chain pulley block and tripod and checking for fault.
Reconditioning of LV Aluminum coil per kg
Providing and fitting of HV leg coil Aluminium SE (per Kg)
Providing and fitting of HV leg coil Aluminium DPC(per Kg)
Providing and fitting of LV leg coil Aluminium DPC (per Kg)
Providing & fitting of HV bushing
Providing& fitting of LV bushing
Providing& fitting of HV bush rod (metal part)per rod
Providing& fitting of LV bush rod (metal part) per rod
Providing& fitting of gasket set
Providing& fitting of tapping switch with handle
Providing & fitting of LT terminal plate
Providing & fitting of Oil drain valve
Providing & fitting of core laminations per Kg
Providing& fitting of sundry items
Heat treatment of repaired transformer
Arresting of oil leakages if any by way of welding etc.
Painting of transformer body
Silica Gel breather
Assembling of transformer and lowering into the tank using chain pulley block and tripod. Assembling of top cover thereof and filling of transformer oil after dehydrating.
Loading of transformer into Mechanical transport using crane / skilled and un-skilled labour using tools and tackles and carriage to the site of work (For Urban areas). Mounting the transformer on poles/ platform with the help of crane / skilled and un-skilled labour using tools and tackles after dismounting the temporarily installed transformer
Making of LT side cable connections as well as HT side cable connections and charging the transformer on no load conditions and thereafter checking on full load conditions.
Providing and filling of transformer oil for topping (per litre)
Providing & fitting of Lighting arrestor station type
Providing & fitting of Lighting disc insulator with accessory polymer type
Providing & fitting of Lighting pin insulator with pin polymer type
Providing & fitting of Lighting AB switch 400Amp with handle operated.
Providing & fitting of Lighting AB switch 200Amp with handle operated.
Providing & fitting of horn gap DO switch
Providing & fitting of Prodigy meter
Providing & fitting of chemical earthing
Providing & Fixing of Aluminum unarmored cable 1x120 Sq.mm
Providing & Fixing of Aluminum narmoured cable 1x185 Sq.mm
Road lighting network
Providing & fitting with LED fitting 60/65 Watt along with allied Nipple for fixing of LED Fitting with wire mesh protection etc.
Providing and fitting of MCB/ SPN installed for controlling of Road lighting Network of following
SPN 32Amp
TPN MCB 32Amp.
Supply and fixing of dust and weather proof gasketted 250mm x 250mm x 200 mm deep cable looping box (nominal) size made out of 18 SWG fitted with pole with the help of 2 Nos. MS clamp (25x3mm) thick flat strip of suitable size with nuts and bolts. Complete with hinged cover locking L-Key/Nut Bolts type, earth studs suitable for poles mounted including supply and fixing of 6A MCB SP, MCB carrier and 4-way 63A terminal block fixed on suitable size and suitable for receiving PVC armoured cable complete with connections and painting etc.
Providing and fitting of connection strip 63Amp 4pole heavy duty
Providing & Fixing of prodigy meter
Providing and fitting of SP MCB 6Amp. in existing connection box
Repairing of existing 150/160 Watt LED light
Providing and fitting of connection wire 2x1.5 sq mm in steel tubular pole.
Fabrication, Supplying and fixing of 40mm dia MS pipe (Medium Class) bracket for mounting LED Street light fitting on pole at appropriate place including bending to required shape at 105 degree, 2 nos 40 mm x 3 mm flat iron clamps with nuts, bolts and washer, painting to clamps with primer and finish paint etc as required complete Job.
Providing and fitting of contractor MNX 9Amp. For timer
Providing and fitting Solar/Quartz timer
Cables of following sizes
Providing & laying of Aluminum armored in ground 2.5feet below the ground level along with HDPC pipe 40mm Dia of Following sizes:-
2x10 Sq.mm
4x10Sqmm
4x16Sqmm
4x25 Sqmm
4x35 Sqmm
3.5x50Sqmm
Internal Electrification
Providing & fixing fall ceiling light 6/7 watt
Providing & fixing fall ceiling light 9/10 watt
Providing & fixing fall ceiling light 12 watt
Providing & fixing LED tube light complete fitting 20 watt
Providing & fixing LED bulb 9 watt
Providing & fixing modular switch 5/6Amp
Providing & fixing modular switch 15/16Amp
Providing & fixing modular socket 5/6Amp
Providing & fixing modular socket 15/16Amp
Providing & fixing modular bell push
Providing & fixing Fan dimmer
Providing & fixing modular plate 2 module
Providing & fixing modular plate 3 module
Providing & fixing modular plate 4module
Providing & fixing modular plate 6 module
Providing & fixing modular plate 12 module
Providing & fixing SPN 32 amp in existing DB
Providing & fixing SP 6 to 32 amp in existing DB
Providing & fixing TPN 32 amp in existing DB
Providing & fixing modular plate 6 module
Providing & fixing of following size single core copper wire in existing conduit.
1x1.5 sqmm
1x2.5 sqmm
1x4 sqmm
1x6 sqmm
Providing & fixing Ceiling fan 1200mm base model
Providing & fixing exhaust fan 300mm
Providing & fixing Inverter 1000VA
Providing & fixing Inverter 2000VA
Invertor Battery 160 AH
Servicing of window/spilt AC
Water distribution system
Providing & laying of GI pipe, complete with fitting in ground including trench & refilling the same.
40mm Dia
50mm Dia
65mm Dia
80mm Dia
100mm Dia
Providing & laying of GI Elbow of following sizes:-
40mm Dia
50mm Dia
65mm Dia
80mm Dia
Providing & laying of GI Socket of following sizes:-
40mm Dia
50mm Dia
65mm Dia
100mm Dia
Providing & fixing of MS flange of following sizes:-
Providing & fixing Sluice Valve cast Iron (Heavy Duty)
Providing & fixing NRV cast Iron (Heavy Duty)
Repairing of cast Iron valve with finishing and polishing
Jointing of MS/GI pipe 50mmdia to make leak proof
Providing and fitting of short bend of following sizes
Providing and fitting of Long bend of following sizes
Providing and fitting Puncher Roll to make leak proof connection
Adhesive Tape
VEE GEE ENGINEERS
Ashok Kumar
SUPER ELECTRICALS
GLOBAL ENGINEERS
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .