Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹38,395.31Admitted-Fee/PreQual/Technical/Finance KERALA KL | L1 | Admitted-Fee/PreQual/Technical/Finance | ||
| 2 | L2₹39,019.62+₹624.31 (1.63%)Admitted-Fee/PreQual/Technical/Finance | L2 | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
₹39,020
Closing Date
1 Oct 2026, 6:00 pmClosed
Assistant Engineer
Office of the Asst.Executive Engineer,LSGD Sub Divisin,Parakkodu BP
Annual Plan-Parakkode BP-Pr.No.S0141/26- Mannadi Kalluvettankuzhy Lekshanveedu Colony Well maintenance and installation of Tank in Kadampanadu GP
2026_LSGD_869405_1
19/2026/AE/LSGD/PKD
Open Tender
Electrical Works
Percentage
180 days
Parakkodu
Please refer Tender documents.
9 documents required · 9 mandatory
₹335
Yes
Yes
8 Oct 2026
23 Sept 2026
3 Oct 2026
23 Sept 2026
1 Oct 2026
23 Sept 2026
23 Sept 2026 - 1 Oct 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1ELECTRIFICATION | |||||
| 1.001 | 90.14.1.1:Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623.
Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 2.00mm CRCA sheet, powder coated (excluding base frame) | 3.7 | sqm | 2,830.07 | ₹10,471.26 |
| 1.002 | 90.14.3.2:Supply and providing heavy duty 'A' section neoprene gasket in the panel boardU' section rubber beeding suitable for 1.60/ 2.00 mm sheet | 8 | metre | 7.9 | ₹63.2 |
| 1.003 | 90.14.5:Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board | 10 | kg | 177.14 | ₹1,771.4 |
| 1.004 | 90.3.17.3:Supply, conveyance and erection of the following sizes of 'B' class GI pipe in single section for post top lantern of all types on concrete base (excluding charges for concrete base and excavation) and painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer etc. as required.50 mm dia GI pipe | 4 | metre | 933.61 | ₹3,734.44 |
| 1.005 | 90.14.7:Supply and providing copper earth bus in the panel board | 75 | Cum cm | 6.36 | ₹477 |
| 1.006 | 14.1:Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres. | 0.4 | cum | 455.06 | ₹182.02 |
| 1.007 | 14.9:Providing and laying in position cement concrete 1 :3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required. | 0.6 | cum | 8,972.71 | ₹5,383.63 |
| 1.008 | 2.10.3:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature
circuit breaker suitable for inductive load of following poles in the existing MCB
DB complete with connections, testing and commissioning etc. as required.
Double pole | 2 | each | 755.29 | ₹1,510.58 |
| 1.009 | 2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps | 1 | each | 500.57 | ₹500.57 |
stage.html
html • 0.02 MB
finance_1479164.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.09 MB
sbd.pdf
Tender Documents • 1.65 MB
epayrajee.pdf
Tender Documents • 1.75 MB
BOQ_1479164.xls
BOQ • 0.33 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .