Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.7 LAccepted-AOC | L1 | Accepted-AOC Being lowest bidder and reasonable | |
| 2 | L2₹28.6 L+₹61,807.60 (2.21%)Rejected-AOC | L2 | Rejected-AOC Not being lowest bidder | |
| 3 | L3₹29.2 L+₹1.2 L (4.17%)Rejected-AOC | L3 | Rejected-AOC Not being lowest bidder | |
| 4 | L4₹29.9 L+₹1.9 L (6.62%)Rejected-AOC | L4 | Rejected-AOC Not being lowest bidder | |
| 5 | L5₹31.3 L+₹3.3 L (11.6%)Rejected-AOC NO S 7 2ND CROSS 2ND MAIN KEB LAYOUT SANJAYANAGAR BANGALORE 560094 | BENGALURU URBAN | KARNATAKA | 560094 | L5 | Rejected-AOC Not being lowest bidder |
Tender Value
Refer Docs
EMD Value
₹64,000
Closing Date
25 Nov 2020, 6:00 pmClosed
GE I R nd D West Bengaluru
GARRISON ENGINEER I R nd D WEST BANGALORE DRDO COMPLEX CV RAMAN NAGAR BANGALORE
OUTSOURCING SERVICES FOR OPERATION AND MAINT OF ELECTRIC, WATER SUPPLY INSTALLATIONS,INTERNAL ELECTRIFICATION, TRANSFORMER OIL FILTRATION AND SERVICING OF VCBs / ACBs AT MTRDC (RESIDENTIAL AREA) AT BANGALORE
2020_MES_369567_2
GE(I) R ND D (WEST)/BAN/36 OF 2020-21 8833E8
Open Tender
Manpower Supply
Item Rate
330 days
Bengaluru
Class and Category as per NIT
8 documents required · 8 mandatory
₹500
GE I R nd D West Bengaluru
₹64,000
Yes
23 Dec 2020
9 Nov 2020
1 Dec 2020
10 Nov 2020
25 Nov 2020
12 Nov 2020
10 Nov 2020 - 11 Nov 2020
Amount
SCHEDULE 'A' PART - I (OUTSOURCING SERVICES)
Providing services for operation, maintenance of electric supply and water supply installations including internal electrification of buildings at married accommodation of Residential areas by deploying skilled, qualified persons having experience in handling similar equipments/services and periodical maintenance to equipments, maintaining log sheets, complaint register, maintenance register, breakdown register etc complete. The scope of work/services to be provided by contractor in each shift and number of shifts in day for Residential areas are enumerated below and as specified in particular specification in following areas :- MTRDC residential area at HMT Complex in three shifts (round the clock in three shifts on all days including Sundays and Holidays), 1st shift from 0600 Hours to 1400 Hours, 2nd Shift from 1400 Hours to 2200 Hours, 3rd shift from 2200 Hours to 0600 Hours) with Electrician - 1 No and Helper - 1 No per shift NOTES :- (i) Details of equipment/services to be maintained are indicated as appendices in PS. (ii) Various items required for replacement are regulated by the department except those given under relevent items of schedule ‘A’ as supply only. However replacement cost of these items are deemed to be included in this item. (iii) The Items mentioned under relevent items of schedule ‘A’ shall be supplied by the contractor as and when required at site and the same shall be measured and paid under relevant items of Sch 'A' Part - II.
Notes for Sl Item Nos 1.00 to 1.06 (including Sub Items) Contd., (iv) Tenderer shall maintain relevant slips of complaints attended and materials used duly signed by users and any other documents as signed by dept and cost of the same is deemed to be included in the rate quoted. (v) T&P, HT fuse wire and safety gear required for attending to the complaints will have to be arranged by the tenderer at no extra cost to the department. (vi) Attention is drawn to latest minimum fair wages payable as notified (time to time) by Govt Of India / State Govt / Local body whichever is higher, including taxes as applicable and quote their rates accordingly. Contractor shall not have any claim on account of misunderstanding / under quoting in this regards. vii) Tenderer shall arrange insurance to his work-men and relevant proofs of the same shall be submitted to the department as and when demanded, the cost for the same is deemed to be included in the rate quoted. Responsibility of compliance of labour regulations in force lies with the tenderer. The provision of statutory laws relating to minimum wages, EPF, EDLI, ESIC, Bonus, GST, Cess & other levies payable shall be strictly adhered to by the contractor. The Contractor shall produce proof of wages, EPF, ESIC, Bonus paid against the respective workmen while claiming payments. viii) Absent from duty of technician is not permissible as E&M services are essential in nature. However, the absence will invite penalty as specified in tender and recovery shall be done through recovery statement from the payment due to Contractor. The tenderer will have no claim whatsoever on this account and decision of Accepting officer in this regard will be final and binding.
Notes for Sl Item Nos 1.00 to 1.06 (including Sub Items) Contd., ix) Tenderer shall work out and quote the rates under Col 5, Col 7, Col 9, Col 11 & Col 13 for each item / sub items. Rate quoted under Col 9 (overheads and Profits) shall also deemed to include for consumable items, uniforms, stationery charges, etc., required for proper operation and maintenance of equipments. x) Bidders are advised to follow the websites/ notifications of respective Department/ Organization regularly, and ensure that any changes in minimum fair wages/ contributions, Taxes are accounted by them and revise their quoted rates accordingly before end date of submission of Bid. No claim of not aware of new Notifications / Circulars will be entertained after bids are closed on account of revisions. xi) Bid submitted by Tenderer under following stipulations shall be treated as non - bonafide / invalid / disqualified and such bids will not be considered for acceptance and in such case the lowest bidder shall be determined from amongst the valid / bonafide bids only :- a) Quoting wages under Col 5 against any item / sub-items of BOQ shall not be less than the prevailing minimum rates of wages payable as notified by Govt. of India/ Concerned State Govt / Local body whichever is higher. b) Quoted rate under Col 7 i.e., Bonus, shall not be less than Minimum payable (8.33%) and shall be based on actual payment basis. c) Quoted % under col 9 i.e., for “OH&P, consumable items, uniforms, stationary, etc., should not be “Nil”/”Zero” consideration, d) ESIC % under Column 13 is @ 3.25% subject to Salary less than 21,000/- as per instructions in vogue
Notes for Sl Item Nos 1.00 to 1.06 (including Sub Items) Contd., xii) In case Contractor is liable to pay EPF, % quote under Column 11 shall not be less than % applicable as per EPF & MP Act and its latest notifications / amendments. xiii) Quoted rates shall deemed to be inclusive of all taxes, cess, levies as applicable including GST. xiv) Any Govt / statutory variations in minimum wages, liability of EPF, ESIC, EDLI, BONUS, LWC, GST shall be adjusted from re-imbursement / recovery as specified in Special Conditions here-in-after. The prevailing wages / Contribution prevailing on the bid submission end date shall be base for adjustment / re-imbursement as specified here-in-after. xv) Exemptions / limiatations, if any shall not be considered while quoting rates, EPF, EDLI, ESIC, BONUS, LWC as the same shall be calculated during actual contribution payable depending upon the salary of the individual based on the number of days engaged in the work. xvi) Contractor’s attention is invited to Labour Wages Act with regards to payment of wages to the individuals engaged under this work. Contractor shall make the payments to their staff / employees by Cheque or through NEFT in their Bank Account, and the particulars of same shall be submitted to the department while claiming any payment. No payments will be made, unless proof of payment of wages through bank account is submitted by the Contractor/firm while claiming bills. xvii) The wages, / contribution towards EPF, EDLI, ESIC, Bonus shall be paid by the GE in RAR / Final bill only after submission of valid and authentic document in support of proof of payment / contribution of requisite amount to the workmen by the Contractor. In case, the Contractor fails to submit proof of payment made to Workmen, no payment will be made by Department.
Notes for Sl Item Nos 1.00 to 1.06 (including Sub Items) Contd., xviii) Payment in respect of any item / sub-item of BoQ in RAR / Final bill towards the wages, EPF, EDLI, ESIC, Bonus shall be made on the actual amount paid to the Workmen by the Contractor, subject to maxium of the rate quoted under respective heads, plus his quoted OH&P & LWC and no extra claim by the Contractor shall be admissible in this account. In case, Contractor pays less than quoted rates, payments will be made on the actual amount paid by the Contractor plus his quoted OH&P & LWC and nothing extra over and above his quoted rates is payable by the Department except revisions by Govt. Any violation of Acts rests with Contractor and Contractor shall be solely responsible for same..
Rate for Electrician per Shift
Rate for Helper per Shift
Description of Work / Item(s)
Amount
SCHEDULE 'A' PART - II (SUPPLY OF MATERIALS, MAINTENANCE AND REPAIRS)
Supply only PVC insulated, PVC unsheathed, multi-stranded heavy duty copper conductor cable of 1.5 sq.mm size, FRLS grade, complete all as specified and directed.
Supply only PVC insulated, PVC unsheathed, multi-stranded heavy duty copper conductor cable of 2.5 sq.mm size, FRLS grade, complete all as specified and directed.
Supply only PVC insulated, PVC unsheathed multi-stranded heavy duty copper conductor cable of 4.0 sq.mm size, FRLS grade, complete all as specified and directed.
Supply only switch piano, flush type, 5/6 Amps single pole, 230 V, one way, complete all as specified and directed.
Supply only calling bell, ding-dong type, working on AC, 230 V, single phase, complete all as specified and directed.
Supply only bell push, single pole, flush type, 230 V, 5 Amps, complete all as specified and directed.
Supply only socket, 3 & 2 pin, 5 A, 240 V, 50 Hz, flush type, complete all as specified and directed.
Supply only electronic fan regulator, 230 volts, 120 W, stepped stype complete all as specified
Supply only fan capacitor of 2.5 mfd for ceiling fan, single phase, 230 V, complete all as specified and directed.
Supply only ceiling fan clamps for fixing of ceiling fans with rubber bushings, complete all as specified and directed.
Supply only PVC, ceiling rose three terminals white bakelite type complete all as directed.
Supply only modular Switch, One module , One way, 5/6 Amps, 240 Volts all as specified and as directed.
Supply only modular Switch, One module , One way, 16 Amps, 240 Volts all as specified and as directed.
Supply only modular socket outlet 5/6 Amps 5 pin, one module, complete all as specified and directed.
Supply only modular socket outlet 6/16 Amps 5 pin, Module 2, complete all as specified and directed.
Supply only modular bell push switch, one module, single pole, 230 volts 5/6 Amps capacity all as specified
Supply only modular fan Regulator,120 W, electronic stepped type, 230 Volts 2 module, complete all as specified and as directed.
Supply only plug top, 3 pin, 15 Amps, 240 V, 50 Hz, complete all as specified and directed.
Supply only MCB, SP, 230 V, 6 to 32 Amps current rating, 'C' series, 10 KA breaking capacity, complete all as specified and directed.
Supply only MCB SPN, 230 V, 6 to 40 Amps current rating, 'C' series, 10 KA breaking capacity, complete all as specified and directed.
Supply only MCB TPN 63 Amps, 415 Volts, AC, 50 Hz, 240 V, 10 kA, breaking capacity, complete all as specified.
Supply only MCB TP 100 Amps, 415 Volts, AC, 50 Hz, 240 V, 10 kA, breaking capacity, complete all as specified.
Supply only PVC casing/caping of 20mm size, complete all as specified and directed.
Supply only PVC casing/caping of 25 mm size, complete all as specified and directed.
Supply only rigid non metalic PVC conduit of size 25 mm dia medium grade ISI marked complete all as specified.
Supply only rigid non metalic PVC conduit of size 20 mm dia medium grade ISI marked complete all as specified.
Supply only switch socket combination, 3 & 2 pin, 5 A, 240 V, flush type, multipurpose, controlled by one switch, complete all as specified and directed.
Supply only switch socket combination, 3 & 2 pin, 15 A, 240 V, flush type, multipurpose, controlled by one switch, complete all as specified and directed.
Supply only LED bulb 9/11 W all as specified and as directed.
Supply only angle holder suitable for LED lamp 9/11 W, complete all as specified
Supply only LED tube Rod with light fitting, 18 Watt with high lumen output, environmental friendly, energy efficient LED, electrical efficiency > 85%, system efficacy > 100 lm/W, operating voltage between 140 - 270 V, AC, 50 Hz, TDH, 10%, power factor ≥ 0.95, surge protection 2.5 kV, colour temperature 5700 K, CRI > 80, intergral drivers, Ultra bright glass, with very high efficacy suitable for installation in existing T8 fitting with G13 lamp holders, complete as per Cat No CRYSTAL 1213T8DSTL18WLED865SGLASS of make Havells or techno commercially equivalent makes specified here-in-after complete all as specified.
Supply only wall mounted LED tube light fitting with lamp, 9 Watt, 2 ft, with high lumen output, environmental friendly, energy efficient LED, with accessories, IP 20 protection Class I, system electrical efficiency > 85%, system efficacy > 100 lm/W, operating voltage between 140 - 270 V, AC, 50 Hz, TDH, 10%, power factor ≥ 0.95, surge protection 2.5 kV, colour temperature 5700 K, CRI > 80, intergral drivers, complete with diffuser, polyestyer louver with 9 watt LED tube & integrated electronic driver 9 W fitting as per cat No LUMILINEBS9WLED830SPCWH of make Havells or techno commercially equivalent makes specified here-in-after complete all as specified.
Supply only wall mounted LED tube light fitting with lamp, 18 Watt 4 ft length with high lumen output, environmental friendly, energy efficient LED, with accessories, IP 20 protection Class I, system electrical efficiency > 85%, system efficacy > 100 lm/W, operating voltage between 140 - 270 V, AC, 50 Hz, TDH, 10%, power factor ≥ 0.95, surge protection 2.5 kV, colour temperature 5700 K, CRI > 80, intergral drivers, complete with diffuser, polyestyer louver with 18 watt LED tube & integrated electronic driver 18W, fitting as per cat No LUMILINEBS18WLED830SPCWH of make Havells or techno commercially equivalent makes specified here-in-after complete all as specified.
Supply only LED building security light fittings with lamp, 25 W, IP 65, with high lumen output, environmental friendly, energy efficient LED, street light fitting with lamps and accessories, IP 20 protection Class I, system electrical efficiency > 85%, system efficacy > 100 lm/W, operating voltage between 140 - 270 V, AC, 50 Hz, TDH, 10%, power factor ≥ 0.95, surge protection 2.5 kV, colour temperature 5700 K, CRI > 80, intergral drivers, fittings as per Cat No ENDURAPEARLSL25WLED757SASYTOPC of make Havells or techno commercially equivalent makes specified here-in-after complete all as specified.
Taking down existing post top lantern light fitting, Supply and fix 25 W, LED Post top lantern light fittings with lamp 25 W,with high lumen output, environmental friendly, energy efficient LED, with lamps and accessories, IP 65 protection, system electrical efficiency > 85%, system efficacy > 100 lm/W, operating voltage between 140 - 270 V, AC, 50 Hz, TDH, 10%, power factor ≥ 0.95, surge protection 2.5 kV, colour temperature 5700 K, CRI > 80, intergral drivers, fittings made of powder coated housing, enclosed with glass cover in frame, connecting with and including twin twisted copper wire 1.5 sq mm, light fitting conforming to Cat No RUBYPT25WLED757PSYMTOPC of Havells or techno commercially equivalent approved model complete with all accessories and lamp complete all specified and as directed.
Supply only LED street light fittings with lamp, 48 W, New generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP OPENING seperate driver compartment with IP65 protection and impact resistance of IK07 with high lumen output, with and including lamp and accessories, system electrical efficiency > 85%, system efficacy > 100 lm/W, operating voltage between 140 - 270 V, AC, 50 Hz, TDH, 10%, power factor ≥ 0.95, surge protection 2.5 kV, colour temperature 5700 K, CRI > 80, intergral drivers, fittings as per Cat No ENDURAPEARLNEOSL48WLED757SASYTOPC of make Havells or techno commercially equivalent makes specified here-in-after complete all as specified.
Supply and fix, FRP body, loop in / loop out boxes, of size not less than 250 mm x 200 mm x 105 mm (out door type), fitted on poles with suitable size clamps made out of MS flat iron of size 20 x 5 mm GI nuts, bolts and washers complete with 4 way 32 Amps (heavy duty) connector - 2 Nos, including provision of cable glands of suitable size including taking down the old unserviceable ones complete all as specified and directed. Make : Cat Part No GSJB 2520 of M/s Sintex or equivalent in HENSEL / HPL.
Supply metal clad plug 2P+E , 20 Amps , 240 Volts all as directed.
Supply metal clad socket with cap & chain 2P+E, 20 Amps , 240 Volts all as directed.
Supply only Fluorescent tube rod, 4 feet long, 36/40 watts , 230 volts suitable for fixing in tube light fittings complete all as specified.
Supply only tube light starter 230 Volts, single phase suitable for 20/40watts tube light fittings complete all as specified.
Taking down unserviceable, ceiling fans, depositing same in AGE E/M Storeyard, Supply and fix, Ceiling fan BEE 5 star rated complete 1200mm sweep, energy efficient suitable to function on 230V, single phase, AC supply, white colour, with down rod 300mm long, capacitor 2.5 mfd, canopies, nuts, bolts and washers and connecting with and including provision of 3 core 1.5 sq.mm PVC sheathed flexible copper conductor from ceiling, writing MES number on ceiling fan motor complete all as specified and directed. MAKE:- Auro Plus of Crompton Greaves or techno-commercially equivalent model in BAJAJ / HAVELLS / USHA
Taking down existing unserviceable exhaust fan of any sweep with blade and louvers and depositing same in AGE E/M store yard, Supply and fix, exhaust fan 230/240 Volt, 50 Hz, single phase, AC supply, 300 mm sweep with louvers complete with metal body powder coated with protective steel bird guard on wall of building with and including provision of 3 core 1.5 Sq.mm flexible cable from ceiling rose to exhaust fan including writing MES number on exhaust fan motor using synthetic enamel paint of approved tint, complete all as specified and directed. MAKE:- Model: Ventil Air-DSP of Havells or techno-commercially equivalent model in Almonard / Bajaj.
Taking down unserviceable, storage water heaters depositing same in AGE E/M Storeyard, Supply, installation, testing and commissioning of vertical type electric storage water heater of capacity 25 litre, BEE five star rated, 230 Volt, AC, 50Hz, comprising of heating element 2000/2500 Watt, puf insulation, both power indicating LED lamp and heating indicating LED lamp, actual standing energy loss per 24 hours / 45°C temperature difference not to exceed 0.5KWH, re-heating time for 35°C temperature rise not to exceed 20 minute, adjustable thermostat (temperature range in °C is 25-75±5), rated water pressure (N/sq.cm, water head (metre)) is 80/80, glass lined tank, glass coated heating element (to prevent water scale formation on element), temperature control knob, anode ord (to protect tank from corossive element), thermal cutout, safety valve (the safety valve shall be designed to automatically relieve pressure and discharge water in case the pressure overshoots the preset limits), with and including provision of necessary suitable 3-core copper cable, suitable plug top, , fixing of geyser on wall / surface with and including provison of suitable size of wall mouting bracket and 100mm length anchor bolts, including provision of all necessary plumbing work, civil works etc., complete all as specified and directed. MAKE:- AO Smith / Racold / Venus / Jaquar Note : PVC rigid pipe connection for hot and cold water shall be measured and paid separately under respective item of this Schedule.
Taking down existing ceiling fan/exhaust fan of any sweep with blade and down rods etc from ceiling/walls by unscrewing the nut bolts, opening the split pin and keeping in safe custody repairing and re-fixing the same after repairs, preparing the surfaces and spray painting with two coats of synthetic enamel paint, writing MES No. complete all as specified and as directed. NOTE: Repairs shall be measured and paid for separately under respective items.
Disconnecting, taking down ceiling fan, with blade, inspecting motor assembly, replacing burnt out capacitors, split pins, etc, servicing, cleaning, greasing, removing all deposited materials, checking for smooth functioning, re-assembling the same complete all as specified and directed. NOTE:- Cost of PVC capacitor bracket -1 No, split pins - 6 Nos, 2.5 mfd capacitor - 1 No, shall deemed to include in this item.
Rewinding of ceiling fan motor with super enameled copper winding wire of suitable gauge after cutting and removing burnt winding, including varnishing of new winding and drying up carefully all as specified and directed.
Dismantling / opening of exhaust fan of 300/450mm sweep motor assembly inspecting all dismantled parts repairing replacing the unserviceable parts and following components with new ones including oiling greasing reassembling motor assembly all as specified and directed. NOTE:- Cost of PVC capacitor bracket -1 No, split pins - 1 Nos, & 2 mfd Capacitor - 1 No, shall be included in this item.
Rewinding of exhaust fan motor 300/450 mm sweep with super enameled copper winding wire of suitable gauge after cutting and removing burnt winding, including varnishing of new winding and drying up carefully all as specified and directed.
Cutting, trimming and pruning of trees / tree branches of any girth up to 2.5 m all around the existing LT overhead lines / surroundings of street lights, flood light fittings and LT poles including cleaning the disturbed area beneath the LT overhead lines and removing the trees/tree branches and debris from the site and depositing at a place as directed at site.
Excavation in trenches in hard / dense soil not exceeding 1.5 metre wide not exceeding 1.5 metre in depth; for laying of cables not exceeding 10 Sqm on plan and not exceeding 1.5 m in depth and getting out , trimming sides, forming bottom surface to required level complete all as specified and as directed .
Returning filling with excavated soil, including spreading, leveling , watering and well ramming in layers not exceeding 25 cm in soil as directed .
Removing of excavated soil to a distance not exceeding 50 m & depositing where as directed at a level not exceeding 1.5m above starting point all as specified and as directed.
Sand cushioning in layers for cables in trenches / ducts for cable including consolidation complete all as specified and directed. NOTE: Punned thickness will be measured for payment purpose.
Bricks, sub class 'B' of old size 230 mm x 115 mm x 75 mm laid in trenches for cable protection all as specified and directed.
Material and labour for, Galvanized Iron tubing, light grade, 40 mm bore for protection of cable laid at road crossing / on pole including provision of clamps made of mild steel flat iron of size 25 x 5 mm, bolts, nuts, washers, etc., removal of old unserviceable pipes complete all as specified and directed.
Supply and lay cable XLPE insulated armoured LT cable 1100 volts grade of size 10 Sq mm 2 core, in trenches/ on walls / poles including suitable MS clamps for fixing if required, connecting, testing and commissioning including taking down or pulling out the existing unserviceable cable complete all as specified and as directed Notes:- Earthwork, sand filling, brick protection, lugs shall be measured and paid separately under relevant items of this schedule.
All as per item 57 here in before but of cable 25 sq mm 3.5 core
All as per item 57 here in before but of cable 35 sq mm 3.5 core
All as per item 57 here in before but of cable 50 sq mm 3.5 core
Taking down unserviceable wiring, supply and fix, PVC insulated, armoured and PVC sheathed 1100 volts grade, aluminium conductor of size 4 sq mm 2 core, from looping box to fitting, complete all as specified and as directed.
Taking out old unserviceable joints, Supply, jointing new outdoor termination, heat shrink type joint, suitable for 11 KV (earthed) grade XLPE armoured aluminium conductor cable of size 3 core 16 to 95 sqmm, testing, complete all as specified and as directed
Disconnecting and removing the burnt cable end terminal at incoming of MCCB DB TPN / Cubicals, cutting suitable length of cable of incoming cable and adjusting cable from loop, preparing cable ends of any size, crimpling aluminium lugs of suitable size, connecting back with necessary bolts, nuts, washers, etc.,testing for any loose connections and making good the disturbed surfaces complete all as specified.. NOTE: The rate shall deemed to include for making hole in masonry / concrete to draw cables from loop and making good the disturbed surface matching with the adjacent surfaces, complete as per directions of Engineer-in-Charge.
Supply and fix, Aluminium lugs for aluminium conductor cables of 16 sqmm size
Supply and fix, Aluminium lugs for aluminium conductor cables of 25 sqmm size
Supply and fix, Aluminium lugs for aluminium conductor cables of 35 sqmm size
Supply and fix, Aluminium lugs for aluminium conductor cables of 50 sqmm size
Supply and fix, Aluminium lugs for aluminium conductor cables of 70 sqmm size
Taking down old security light, timer switch box 0.80 m x 0.80 m x 0.30 m, fabricated out of 16 SWG CRCA sheet, powder coated, with mounting, locking arrangement, complete and Supply and fixing Timer switch box fabricated out of 16 SWG CRCA sheet with mounting and locking arrangement duly powder coated consisting of following :- (a) Digital timer, 65 A, 3 P, 230 V, all as per Indo Asian Cat Part No. TL065AB0 of Indoasian or techno commercially equivalent in other makes specified - 01 No (b) Power contactor 63 Amps Make: L&T/Havells/INDOASIAN- 01 No. (c) Connector 100 Amps 230 volts - 03 Nos. (d) MCCB TP 63 Amps 415 volts - 01 No. (e) Control fuse 2 Amps - 01 No.
Material and labour for Preparation of old painted surfaces of steel pole, of 8.5 to 9 m long, applying zebra marking painting with two coats of synthetic enamel paint of approved make from ground level & upto 0.9 metre height (3 strips of black, 3 strips of yellow, each of 15 cm width) and remaining length with two coats of aluminium paint, painting pole terminal box, white wash to the coping etc., writing pole numbers on each pole to match with existing one, complete all as specified and directed .
Material and labour for, Preparation of old painted surfaces of steel pole 4.0 metre long and painting two coats of aluminium paint, and white washing the coping of pole complete all as specified and directed.
Dismantling old steel tubular pole, RCC pole of any length, Supply, erect and connecting, Steel tubular swaged poles type 410 SP-22 (9 metres long), ISI marked, complete with CI base plate and finial taper plug, bolts, nuts & screws complete including painting all as specified and directed. Note: Excavation and earthwork, PCC foundation, coping of poles shall be measured and paid separately under respective item. complete all as directed.
Supply only MCCB Three Pole, 63 Amps, 16KA breaking capacity, 415Volts all as specified.
Supply only MCCB Three Pole, 100 Amps, 16 KA breaking capacity, 415Volts all as specified.
Supply only MCCB four Pole, 200 Amps, 35/36 KA breaking capacity, 415Volts all as specified.
Supply only heating element 1500 Watt with rubber bush and all accessories complete all as specified and as directed.
Supply only thermostatic switch suitable for geysers of any capacity and type complete all as specified and as directed.
Supply only Hot and Cold connection pipe 15/20mm dia 450mm long with couplers and washers on both sides of geysers as per Cat Part No F8070403 of CERA or tehcno commercial equivalent in ESS ESS / JAQUAR / HINDWARE / JOHNSON / MARC complete all as specified and as directed.
Supply and fix in repairs Silica Gel Breather assembly complete duly filled with silica gel stones suitable for transformer of capacity 250 / 500 KVA complete all as specified and as directed.
Topping up of transformer oil ISI marked duly tested with proper die-electric strength upto desired level after heating up of oil suitable for 11 KV power system complete all as specified and as directed.
Dehydration of transformer oil ISI marked through on line filteration to with stand die electric strength of 50 KV for 1 minute at 2.5 mm gap and flash at 60 KV without disturbing the system complete complete all as specified and as directed.
Servicing of transformer by dismantling the top cover, checking of HT/LT bushings from core winding cleaning / removing the sludge from the transformer tank, cleaning inside the radiator and core winding, cleaning the radiator coil including checking the connecctions of proctetive devices like winding, temperature indicators, replacing the top cover gaskets and washers with new one and charging of the transformer with grey colour enamel paint and testing and commissioning complete including painting, all as specified and as directed by Engineer-in-Charge for 200 KVA transformer .
Servicing and painting of two / four pole structure consisiting of poles, rolled steel joists mild steel channels and supports with one coat of aluminium paint including colour code for RYB to indicate the colour code for body earthing and lightning arrestor complete including taking proper shut down, greasing the GOD switch, tightening of all bolts & nuts, replacement of ACSR conductor, PVC sleeves, wornout lugs, PG clamps and HT fuses in the structure as required at site including two coats of white wash for masonary plat form, one coat of synthetic enamal paint for weld mesh, removing of weeds / plants inside the yard and cleaning the entire premises complete all as specified and as directed.
Supply and fix, three Phase non-linear type lightning arrestor suitable for three wire 11 KV overhead lines complete with galvanised clamping arrangement, GI bolts, nuts and washers complete including taking down old arrestor all as specified and as directed.
Material and labour for plain Cement Concrete (1:3:6), type C1, using 20 mm graded stone aggregates for coping of poles / plinth blocks of HT poles etc., including necessary form work and finishing the exposed surfaces even and smooth without using extra cement complete all as specified and directed.
Material and labour for, Plain cement concrete (1:4:8), type D2 ,using 40 mm graded stone aggregates for foundation of poles complete all as specified and directed.
Demolishing old earthing pit, and providing new earthing pit with material and labour for earthing complete with Galvanized Iron earth plate electrode 600 mm x 600 mm x 6.3 mm buried directly in ground vertically in pit of depth not less than 2.25 metre below normal ground level with top edge of the earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides with mixture of charcoal and common salt in alternate layers and electrode connected to GI earth wire of 4 mm dia by means of bolts, nuts, check nuts and washers, earth wire protected by galvanized steel pipe 15 mm bore (light grade) connected to earthing test point all as shown in electrical plate No. 3 of SSR-2009 Part I and including necessary excavation and earth work in any type of soil, 40 mm bore light grade GI pipe for watering funnel wire mesh, PCC chamber in cement concrete (1:3:6), type C1 , manhole cover with RCC (1:2:4), type B-1, reinforced with 6 mm dia MS round bars @ 15 cm c/c both ways for cover and MS frame etc., complete all as specified and as directed NOTES :- (i) The quoted rate deemed to include earth wire and protection pipe up to 7.5 metre from earth plate / earth point/test point. (ii) Earth pit shall be constructed at least 0.5 metre away from each earth chamber.
Demolishing old earthing pit, and providing new earthing pit with material and labour for earthing complete with Galvanized Iron earth plate electrode 600 mm x 600 mm x 6.3 mm buried directly in ground vertically in pit of depth not less than 2.25 metre below normal ground level with top edge of the earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides with mixture of charcoal and common salt in alternate layers and electrode connected to GI earth strip of 32 x 6 mm, by means of bolts, nuts, check nuts and washers, earth wire protected by galvanized steel pipe 20 mm bore (light grade) connected to earthing test point all as shown in electrical plate No. 3 of SSR-2009 Part I and including necessary excavation and earth work in any type of soil, 40 mm bore light grade GI pipe for watering funnel wire mesh, PCC chamber in cement concrete (1:3:6), type C1 , manhole cover with RCC (1:2:4), type B-1, reinforced with 6 mm dia MS round bars @ 15 cm c/c both ways for cover and MS frame etc., complete all as specified and as directed NOTES :- (i) The quoted rate deemed to include earth strip and protection pipe up to 7.5 metre from earth plate / earth point/test point. (ii) Earth pit shall be constructed at least 0.5 metre away from each earth chamber.
Solar Electricals and Electronics
kamadhenu Electricals
Pacific Enterprises
SREE VARU ELECTRICALS
UNIVERSAL ENGINEERING
Pacific Enterprises
Solar Electricals and Electronics
SREE VARU ELECTRICALS
UNIVERSAL ENGINEERING
B5BUILDING SOLUTIONS
Bidder Name
UNIVERSAL ENGINEERING
kamadhenu Electricals
SREE VARU ELECTRICALS
Solar Electricals and Electronics
Pacific Enterprises
B5BUILDING SOLUTIONS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .