| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹6.4 LAccepted-AOC | L-1 | Accepted-AOC Accepted as being L-1 bidder and acceptable rate | |
| 2 | Rejected-Technical ALAKHRAJ BHAWAN NEAR MAMTA MOTORS BHUSA MORE WARD NO 7 SINGRAULI M P 486889 | SINGRAULI | MADHYA PRADESH | 486889 | - | Rejected-Technical Not opened for technical evaluation hence rejected as being L-2 | |
| 3 | Rejected-Technical | - | Rejected-Technical Not opened for technical evaluation hence rejected as being L-3 |
Tender Value
₹11.5 L
EMD Value
₹14,400
Closing Date
29 Jul 2024, 5:00 pmClosed
Staff Officer (EnM)
OFFICE OF THE AREA GENERAL MANAGER HASDEO AREA PO SOUTH JHAGRAKHAND COLLIERY DISTT MCB (CG) PIN 497448
Complete Electrical Wiring and Maintenance, Renovation of Hasdeo House under AHQ at Hasdeo Area
2024_SECL_313299_1
AGM/HSD/SO(EnM)/E-Tender/42 Date-24.07.2024
Open Tender
Electrical and Maintenance Works
Item Rate
45 days
Hasdeo Area
6 documents required · 6 mandatory
₹14,400
19 Aug 2024
24 Jul 2024
30 Jul 2024
24 Jul 2024
29 Jul 2024
24 Jul 2024
24 Jul 2024 - 26 Jul 2024
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor singlecore cable etc as required. Group A
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor singlecore cable etc as required. Group B
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2X4 Sqmm+1x4 Sqmm earthwire
Supplying, installation, testing and commissioning of following capacity overhead distribution bus trunking with aluminium bus bars having current density of 130A/ sq cm at nominal current rating in 1.6mm thick IP 42 sheet steel enclosure in convenient sections with provison of tapping points for use on, 3 phase, 4 wire, 415 V, 50 Hz, AC Supply including jointing of sections, bends, earthing with 2 runs of galvanised iron strips, all installation accessories etc. as required, 200A
Supplying, installation, testing and commissioning of following capacity overhead distribution bus trunking with aluminium bus bars having current density of 130A/ sq cm at nominal current rating in 1.6mm thick IP 42 sheet steel enclosure in convenient sections with provison of tapping points for use on, 3 phase, 4 wire, 415 V, 50 Hz, AC Supply including jointing of sections, bends, earthing with 2 runs of galvanised iron strips, all installation accessories etc. as required, 400A
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. A) 5/6 AMPS Switch
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. B) 2 Way 5/6 AMPS Switch
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. C) 15/16 AMPS Switch
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. D) 3 Pin 5/6 AMPS Socket Outlet
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. E) 6 Pin 15/16 AMPS Socket Outlet
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. F) Telephone Socket Outlet
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. G) T/V Antenna Socket Outlet
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. H) Bell Push
Supply and fixing two module step type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.a
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. A) 1 or 2 Module (75mm x 75mm)
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. B) 4 Module (125mm x 75mm)
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. C) 6 Module (200mm x 75mm)
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. D) 8 Module (125mm x 1255mm)
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. E) 12 Module (200mm x 150mm)
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in FRLSont on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
Supplying and fixing brass batten/ angle holder including connection etc. as required.
Supplying and fixing stiff pendent with 300 mm long, 20 mm dia X 1.6 mm thick steel conduit, aluminium cast back plate and brass holder complete, including wiring the down rod with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and painting etc. as required.
Providing and fixing following rating and breaking capacity MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. A) 125 A 25 KA,TP MCCB
Providing and fixing following rating and breaking capacity MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. B) 200 A 25 KA,TP MCCB
Providing and fixing following rating and breaking capacity MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. C) 400 A 25 KA,TP MCCB
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted (a) 8 way (4 + 24), Double door
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 kA, “C” curve,miniature circuit breaker suitable for inductive load of following poles in the existing A) Single Pole
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 kA, “C” curve,miniature circuit breaker suitable for inductive load of following poles in the existing B) Single Pole and Neutral
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 kA, “C” curve,miniature circuit breaker suitable for inductive load of following poles in the existing C) Double Pole
Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/ 32amps 240 volts “C” curve DP MCB complete with connections, testing and commissioning etc. as required.
Supply and fixing recessed mounting LED down lighter, LED of 1 to 3 Watt each assembled on single MCPCB, having color temp upto 6500K & having 50000 burning hrs. life with minimum @ L 70, system lumen output should be minimum with efficacy>100 lm/Watt. LED driver PF > 0.95, THD < 20% & surge protection 4KV. The colour rendering index of LED light should be more than 70. Housing made of pressure die cast aluminium/CRCA powder coated frame with glare free diffused polycarbonate cover. Submission LM 79- 08/IS16106 (2012), IEC60598, IEC61347i/c connection wire, testing etc. to complete the job. 14/15 Watt color temp 3000-6500K as required
Supply and fixing recessed mounting LED down lighter, LED of 1 to 3 Watt each assembled on single MCPCB, having color temp upto 6500K & having 50000 burning hrs. life with minimum @ L 70, system lumen output should be minimum with efficacy>100 lm/Watt. LED driver PF > 0.95, THD < 20% & surge protection 4KV. The colour rendering index of LED light should be more than 70. Housing made of pressure die cast aluminium/CRCA powder coated frame with glare free diffused polycarbonate cover. Submission LM 79- 08/IS16106 (2012), IEC60598, IEC61347i/c connection wire, testing etc. to complete the job.. (5/6 Watt, color temp 3000-6500k as required.)
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
Supply and fixing of surface mounting type LED light fixture, LED of 1 to 3 Watt each assembled on single MCPCB, having color temp upto 6500K & having 50000 burning hrs. life with minimum @ L 70, system lumen output should be minimum with efficacy>100 lm/Watt. LED driver, PF> 0.95, THD < 20% & surge protection 4KV. The colour rendering index of LED light should be more than 70. Housing made of CRCA powder coated frame with glare free diffused polycarbonate cover. Submission LM 79-08/IS16106 (2012), IEC60598, IEC61347i/c connection wire, testing etc. to complete the job. LED luminiare 2' X 2', 36Watt, color temp 3000-6500k as required
Supplying and fixing of decorative wall mounted lamp complete with fixture and LED
Supplying, erection and testing of approved make wall mounting fan oscillating type with base, blades, guard, speed regulator etc. AC 230-250 volts with connections and including raw bolt/anchor hole fastener etc. complete finished and as required. 400mm Sweep
Supplying and fixing of deluxe fresh air fan with louvers (ventilating fan) with self-closing louvers of decorative PVC blades mounting square frame of approved make complete with all necessary material as required. 250mm RPM 1300/1400
Supplying and fixing of hot water storage water heater vertical with required safety, ABS body including connection pipe, foundation bolt and nut, connection pipe, stop cock, testing etc. to complete the job. 15 ltr (5 star rating standing loses < 0.419 KWH/ 24 Hrs/ 45 C)
Supply, installation, testing and commissioning of EPABX system consist, no. of extension, no of junction, no. of expandable eport, operating console, current on max. load with ISDN compatible of approved make and labor as required as per specifications. A) EPABX system consists of 48 nos extension 8 nos of junction & upto 96 nos of expandable eport with one operating console 2 Amp max current
Supply, installation, testing and commissioning of EPABX system consist, no. of extension, no of junction, no. of expandable eport, operating console, current on max. load with ISDN compatible of approved make and labor as required as per specifications. A) 4 Push button CLI phone
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. A) Upto 35 sq mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. A) Above 35 sq mm & upto 95 Sq mm
Supplying & Fixing of Mini Surface PIR Sensor New as required complete
Supplying & Fixing of Switch Key Tag 30 A key tag with time delay electronic as required complete
Supply and erection of approved make safe earthing electrode consisting pipe-in-pipe technology as per IS 3043-1987 made of corrosion free G.I. pipes with constant ohmic value surrounded by highly conductive compound with high charge dissipation suitable for effective and maintenance free earthing in earth pit of minimum bore dia. 150mm size, as mentioned below :With 2 metre G.I. pipes having outer pipe dia of 50mm having 80-200 micron galvanizing, Inner pipe dia. of 25mm having 200-250 micron galvanizing, connection terminal dia. of 12mm in nominal soil with 25 kg (one Bag) back filling bentonite compound UL listed and confirm to relevant International/Indian standards around electrode upto ground level.
Total impact of GST for the purpose of CTC
ANNAPURNA CONSTRUCTION COMPANY
M/s GYANENDRA TIWARI
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_324670.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .