| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.9 LAccepted-AOC 1ST FLOOR SIDHARTH TOWER BALTI KHARKHANA BYELNE S J ROAD ATHGAON GUWAHATI KAMRUP ASSAM 781001 | KAMRUP METRO | ASSAM | 781001 | L1 | Accepted-AOC accept | |
| 2 | L2₹18.3 L+₹3.4 L (23.1%)Rejected-Finance CHANDAN NAGAR OPP IOCL PERTROL PUMP RAMPUR ROAD BAREILLY UP 243001 | BAREILLY | BAREILLY | UTTAR PRADESH | 243001 | L2 | Rejected-Finance II LOWEST | |
| 3 | L3₹20.9 L+₹6.0 L (40.5%)Rejected-Finance | L3 | Rejected-Finance III LOWEST |
Tender Value
₹23 L
EMD Value
₹23,000
Closing Date
25 Feb 2020, 3:00 pmClosed
SE, EWC
3-Civil Lines, Bareilly
CONSTRUCTION OF NEW 33 KV LILO LINE FROM 33/11KV S/S EINTGAON TO TAPPING POINT OF 33 KV LINE KARELI (PILIBHIT).
2020_MVVNL_434705_1
15/EWC(B)/2019-20
Open Tender
Repair and Maintenance Works
Fixed-rate
30 days
Pilibhit
As per tender document
2 documents required · 2 mandatory
₹3,540
A/c No. 019205006347, IFSC Code ICIC0000192
₹23,000
2 Jul 2020
13 Feb 2020
26 Feb 2020
13 Feb 2020
25 Feb 2020
13 Feb 2020
Amount
Carriage of following line materials for 33 KV line from any Store Centre of Electricity store division bareilly to the site of work including measuring, weighing, loading, unloading at both ends and proper stacking at safe site.
STP 11Mtr. long
ACSR dog conductor
33 KV 3x300mm XLPE Cable
Supply of following material :
M.S. Channel 125x65mm (For line isolator, post insulator, CT stuctures & 13 No. Top channel of length 3200mm with clamp, nut & bolts)
M.S angle lron 65x65x6mm for bracing & guarding (5.8 kg. per Mtr.) :
MS Angle 65x65x6mm bracing for PCC pole 2700mm with clamp, nut & bolts
MS Angle 65x65x6mm bracing for ST pole 4300mm with clamp, nut & bolts
MS Angle 65x65x6mm for guarding 1600mm with clamp, nut & bolts
M.S. Angle 75x75x6mm (For line isolator, post insulator & CT stuctures)
M.S. Angle 50x50x6mm (For line isolator stucture)
33 KV 400A Line type Isolator ( sl No.69 )
33 KV Post insulator
33 KV VCB 800A 750 MVA
33 KV control pannel for feeder
33 KV O/D CT CTR 400/200/1-1-1A
Cross Arm Channel 100x50mm V type
33 KV Pin insulator
33 KV Pin with nut
11 KV Disc insulator B&S type 7000 kg.
Disc fitting Dog/raccon 7000kg.
33 KV 3x300mm cable joitng kit O/D
33 KV 3x300mm cable joitng kit S/Through
G.I. Wire 8 SWG (for guarding & earthing)
PCC pole 9mtr. Long
MS Earthing rod of size 2500x20mm
Stay set complete
F- bracket for 33 KV
33 KV E- bracket with bolts & nuts (for D/P, T/P & F/P)
Packing piece & clamp for cross arm with nut & bolt
Cross arm holding clamp with nut & bolts
Stone pad
Number Plate with clamp, nut & bolts
Danger plate with clamp, nut & bolts
Berbed wire
Nut bolt & washer off size
P.G. Clamp
Turn buckle
Eye bolt
Stay insulator for 33 KV
Erection of following material :
M.S. Channel 125x65mm (Top channel of length 3200mm with clamp, nut & bolts)
M.S angle lron 65x65x6mm for bracing & guarding (5.8 kg. per Mtr.) :
MS Angle 65x65x6mm bracing for PCC pole 2700mm with clamp, nut & bolts
MS Angle 65x65x6mm bracing for ST pole 4300mm with clamp, nut & bolts
33 KV Control panel for single feeder
Cross Arm Channel 100x50mm V type
33 KV Pin insulator
33 KV Pin with nut
11 KV Disc insulator B&S type 7000 kg.
Disc fitting Dog/raccon 7000kg.
33 KV 3x300mm cable joitng kit O/D
33 KV 3x300mm cable joitng kit S/Through
F- bracket for 33 KV
33 KV E- bracket with bolts & nuts
Packing piece & clamp for cross arm with nut & bolt
Cross arm holding clamp with nut & bolts
Stone pad
Number Plate with clamp, nut & bolts
Danger plate with clamp, nut & bolts
Berbed wire
Nut bolt & washer off size
P.G. Clamp
Turn buckle
Earthing (well type bore of S/S switch yard) L.A./VCB/Transformer for LILO System. welding & laying of G.S. strip 50x6mm size with structures and all equipments in switchyard and control room,(GI pipe, GS strip, earthing rod will be provided by the contractor).
Fabracation, erection, painting and grouting of the following structures as per RESSPO/ Approved Drawing and its, plinth 45cm above ground leval as directed by the Engineer Incharge (all type of material such as: cement, brick balast, sand, paint will be provided by the contractor).
Line Isolator Structure
Post Insulator Structure
33 KV VCB Structure
33 KV CT Structure
Mounting and installation, including Mechnical & electrical fixing and adjusting of the following equipments on their respective structures including proper adjustment:
33 KV Isolator Line side
33 KV Post insulator
33 KV VCB complete
24 V Battery set with charger (To be provided by firm I.S.I. mark only of DC System with one float cum boost charger & battery set for 24V. System with 150A.H. Capacity with cabinet).
Complete laying and termination of copper control cable from LILO System, 33 KV CT and 33 KV VCB in the out door switch yard in the relay control panel inside the control room including cost of all materials and labour required for proper completion of works as per RESSPO drawings.
Laying of dog conductor alongwith cost of all required calmps and connectors etc. as per RESSPO Approved drawing of LILO System. All type of connector, nut & bolts will be provided by the contractor)
Erection of the following supports after making of holes with fitting of all accessories clamps etc, grouting of poles as per RESSPO norm & plinthing of support above 300mm gound level by concreating of ratio 1:4:8 (cement brick balast & sand) as per RESSPO norm & painting of ST Pole structure as per norms (all type of paints & red oxide primer will be provided by contractor).
Single support of ST Pole 11mtr long.
Single support of PCC Pole 9mtr long.
Double pole structure on ST Pole 11mtr long complete with bracing.
Double pole cable exposer structure on ST Pole 11mtr long complete with bracing.
End type double pole on ST Pole 11mtr long complete with bracing
Double pole structure on PCC Pole 9mtr long complete with bracing.
Tri pole structure on ST Pole 11mtr long complete with bracing.
Tri Pole structure on PCC Pole 9mtr long complete with bracing.
Four Pole structure on ST Pole 11mtr long complete with bracing.
Four Pole structure on PCC Pole 9mtr long complete with bracing.
Erection/fixing of stay set with stay wire, stay insulator and clamp as per RESSPO drawing including binding, clambing, clamping, tightening, and nozzeling etc. complete in all respect including its grouting in ratio 1:4:8 of cement, sand and brick ballast and sand before back filling of the pits as per RESSPO schedule all clamps, nuts & bolts, cement, brick, concrete blast and etc would be provided by contractor.
Laying and sagging of 3 phase ACSR Dog conductor from Double pole at 33/11 KV substation Eintgaon to tapping point on existing 33 KV Kareli line including jumpering, hoisting, fixing of all type of insulators, binding, jointing and its clamping etc. in all respect.
Guarding of HT/LT/Telephone line/ road/river crossing etc. by providing G.S earth wire 7/16 SWG/GI wire No. 8 and making net with difference of 1.00 Mtr. Completely including fixing of channel/angle etc. with proper locking at each support. All type of nut & bot would be given by the contractor.
Earthing of each S.T Poles of the line is to be done by driving the MS earthing rod 2500x20mm below 0.5 Mtr. In the ground and properly connected to each support with G.S Flat 35x5mm by electric welding process with M.S earthing rod. Earthing plate welding point with support must be 0.15Mtr.above from the plinth of the support,Earthing of each section pole is also to be done. All type of nut & bot would be given by the contractor.
Earthing of each PCC pole of the line by driving the M.S, Earthing rod 2500x20mm below 0.5 Mtr in the ground and properly connected to all metallic parts of the support by GI wire 8 SWG. Earthing of each double pole is also to be done. All type of nut & bot would be given by the contractor.
Laying of single circuit 33 KV 3X300 Sq. mm XLPE cable in normal soil by digging of trench 1050 mm deep, 750 mm wide including supply of required material as fine sand, 1st class bricks, stone slab. (Brick trench material including sand will be supplied by the contractor).
Laying of double circuit 33 KV 3X300 Sq. mm XLPE cable in normal soil by digging of trench 1050 mm deep, 750 mm wide including supply of required material as fine sand, 1st class bricks, stone slab. (Brick trench material including sand will be supplied by the contractor).
Cable laying by drill method single circuit without MS Pipe.
Cable laying in MS Pipe by drill method single circuit (MS pipe will be supplied by the contractor).
Cable laying in HDEP Pipe 150mm dia for single circuit (for 33 KV Cable of size 3x300sqmm) (MS pipe will be supplied by the contractor).
Hoisting of 33 KV 3X300 Sq. mm. XLPE cable on double pole with GI pipe of size 6" dia 3 M long including its jumpering complete with clamps, nuts and bolts (Hoisting material will be supplied by the contractor).
Clearing of the line route by cutting of tree branches during erection of line and also upto the time of energisation completely as per direction of Incharge.
BHARAT ELECTRICAL TRADERS
Anil Kumar Yadav
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .