Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹75.7 LAccepted-AOC 42 I 63 PALAMATTATHIL SOUTH KALAMASSERY SANTHI NAGAR RAJAGIRI P O ERNAKULAM KERALA PIN 683104 | ERNAKULAM | ERNAKULAM | KERALA | 683104 | ₹75.7 L | L1 | Accepted-AOC L1 bidder |
| 2 | L2₹83.6 L+₹7.9 L (10.4%)Rejected-Finance | ₹83.6 L+₹7.9 L (10.4%) | L2 | Rejected-Finance L2 bidder |
| Sl No | Description | Qty | Unit | St.joseph Constructions L2 | PRIMETECH ENGINEERING L1 |
|---|---|---|---|---|---|
| 1.00Construction of Mud Multi Court | |||||
| 1.01 | 2.28.1 : Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m.All kinds of soil | 7,200 | sqm | 39 ₹2,80,800 | 37.58 ₹2,70,576 Lowest |
| 1.02 | OD69912/2024-2025 : Supplying and stacking for measurement sieved red earth at site
including cost and carriage upto 5 k.m. lead complete (red earth sieve through 4.75mm sieve opening) | 1,080 | cum | 1,072 ₹11,57,760 | 1,040.39 ₹11,23,621.2 Lowest |
| 1.03 | OD69919/2024-2025 : Supplying and stacking for measurement Sieved Sand at site including cost and carriage upto 5 k.m. lead all labour charges for stacking, loading and unloading etc complete.(Based on CPWD 30.2.2 & 30.2.4.3) | 270 | cum | 3,317 ₹8,95,590 | 3,218.57 ₹8,69,013.9 Lowest |
| 1.04 | OD69918/2024-2025 : Mixing earth and sand in the required proportion specified r directed by the officer in charge including all cost of labour charges, hire charges of machineries etc complete (Based on CPWD 30.2.9) | 1,350 | cum | 59 ₹79,650 | 57.63 ₹77,800.5 Lowest |
| 1.05 | OD69917/2024-2025 : Spreading of earth and sand in required thickness as per direction of officer in charge including all cost of labour charges, hire charges of machineries etc compete(cost of earth and jamuna sand to be paid separately).( Based on CPWD 30.2.8) | 1,350 | cum | 85 ₹1,14,750 | 82.64 ₹1,11,564 Lowest |
| 1.06 | OD69916/2024-2025 : Consolidation of sub grade with power road roller of 8 to 12 tonne capacity with road roller including making good the undulations etc including all cost of labour, hire charges, fuel, oil etc complete ( Based on CPWD 16.1) | 6,750 | sqm | 4 ₹27,000 | 3.77 ₹25,447.5 Lowest |
| 1.07 | OD69914/2024-2025 : Supply and installation of heavy duty badminton post in
aluminium and steel uprights option with built in weights and floor protection pads.
Base,uprights and back supports can be detached. Rate also includes wheels for easy movement, steel uprights (comes in a pair), badminton net etc. | 4 | pair | 24,456 ₹97,824 | 23,731.8 ₹94,927.2 Lowest |
| 1.08 | OD69915/2024-2025 : Supply and Installation of 7's Football Goal Post (3.65m x 1.80m x 1.20m) made of pipe 10cm dia G.I. pipe with nylon net as per the direction of engineer in charge | 1 | pair | 27,438 ₹27,438 | 26,625 ₹26,625 Lowest |
| 1.09 | OD87078/2025-2026 : Supply of Fixed 3.5 inch Volleyball post set with net including all necessary fitting, labor, transportation charges etc complete | 1 | set | 25,414 ₹25,414 | 24,661.7 ₹24,661.7 Lowest |
Tender Value
₹76.2 L
EMD Value
₹50,000
Closing Date
31 Jul 2025, 3:00 pmClosed
The Chief Engineer, Sports Kerala Foundation
Jimmy George Indoor Stadium, Vellayambalam, Thiruvananthapuram
Construction of Mud Multi Court, RCC Drain and Electric Pole Foundation, RR Step Gallery, Name board, Inauguration stone and Electrification Works
2025_SKF_778674_1
111/SKF/CE/2025-26
Open Tender
Civil Works - Others
Item Rate
180 days
Kollam
Please refer tender document
7 documents required · 7 mandatory
₹2,950
₹50,000
2 Jul 2026
23 Jul 2025
2 Aug 2025
23 Jul 2025
31 Jul 2025
23 Jul 2025
Amount
Construction of Mud Multi Court
2.28.1 : Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m.All kinds of soil
OD69912/2024-2025 : Supplying and stacking for measurement sieved red earth at site including cost and carriage upto 5 k.m. lead complete (red earth sieve through 4.75mm sieve opening)
OD69919/2024-2025 : Supplying and stacking for measurement Sieved Sand at site including cost and carriage upto 5 k.m. lead all labour charges for stacking, loading and unloading etc complete.(Based on CPWD 30.2.2 & 30.2.4.3)
OD69918/2024-2025 : Mixing earth and sand in the required proportion specified r directed by the officer in charge including all cost of labour charges, hire charges of machineries etc complete (Based on CPWD 30.2.9)
OD69917/2024-2025 : Spreading of earth and sand in required thickness as per direction of officer in charge including all cost of labour charges, hire charges of machineries etc compete(cost of earth and jamuna sand to be paid separately).( Based on CPWD 30.2.8)
OD69916/2024-2025 : Consolidation of sub grade with power road roller of 8 to 12 tonne capacity with road roller including making good the undulations etc including all cost of labour, hire charges, fuel, oil etc complete ( Based on CPWD 16.1)
OD69914/2024-2025 : Supply and installation of heavy duty badminton post in aluminium and steel uprights option with built in weights and floor protection pads. Base,uprights and back supports can be detached. Rate also includes wheels for easy movement, steel uprights (comes in a pair), badminton net etc.
OD69915/2024-2025 : Supply and Installation of 7's Football Goal Post (3.65m x 1.80m x 1.20m) made of pipe 10cm dia G.I. pipe with nylon net as per the direction of engineer in charge
OD87078/2025-2026 : Supply of Fixed 3.5 inch Volleyball post set with net including all necessary fitting, labor, transportation charges etc complete
RCC Drain & ; Electric Pole Foundation
2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
5.1.2 : Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size derived from natural sources)
5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
OD69921/2024-2025 : Lifting, conveying and fixing the newly casted RCC covering slabs of any thickness on top of drain in position including all labour charges and miscellaneous expenses etc complete. ( Based on MoRTH 55.25)
5.9.2 : Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
5.22A.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more
RR Step Gallery
2.6.1 : Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.All kinds of soil
2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
60.7.1 : DRY RUBBLE MASONRY _ Dry rubble without concrete levelling course masonry with good quality blasted rubble including packing to compactness to lines and levels cost and conveyance of all materials labour charges etc. complete as per direction of Departmental officers at site
7.1.1 : Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)
13.7.1 : 12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1 cement : 3 fine sand)
10.26.3 : Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approves steel primer.G.I. pipes
13.61.1 : Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work
13.48.1 : Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications: Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of special primer applied @ 0.75 ltr /10 sqm
Name board and Inauguration stone
OD92189/2025-2026 : Providing and fixing 18 mm thick gang saw cut, mirror polished,pre-moulded and pre polished, machine cut for inauguration granite stone of required size, approved shade,colour and texture laid over 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) joint treated with white cement, mixed with matching pigment, epoxy touchups including rubbing, curing etc. complete atall levels. Area of slab over 0.50 sqm
16.21 : Engraving letters in hard stone
2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
4.1.3 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III)derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
OD87052/2024-2025 : Steel work for naming board with G I pipes including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete(Rate based on CPWD 50.10.2)
10.25.2 : Item Shifted to Sub head 14 as item 14.73 : Item Shifted to head 14 as item 14.74 Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
13.61.1 : Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work
Electrification Works
OD83551/2025-2026 : Supply and Installation of 16mtr fixed type Stadium mast suitable for mounting minimum 12no of luminaires, made of Hot-dip Galvanization process as per IS 4759:1996 with monkey climbing arrangement and maintenance platform for easy maintenance and aiming of luminaires with lightening spike. The pole shaft shall be made of 4mm thickness in 2 sections, base dia not less than 250mm and the base plate shall be of min 20mm thick. with all accessories and luminary carriage suitable to install 10/12 nos luminaries in symmetrical arrangement. Excluding RCC Foundation
OD83559/2025-2026 : Supply Conveyance Installation testing and Commissioning of 500W (+/-50) rating Sports lighting LED Floodlight luminaries with minimum 60000 Lumens Light output in CRI>80. Luminaries with combination of 10 Degree, 30 Degree and 60 Degree beam angle to achieve required lux level on the Ground . Design shall be submitted prior to supply. Luminaries, Non-Integral LED floodlight luminaire comprises of die cast aluminium LED housing with toughened glass fixed with clamp and separate Control Gear Housing should have Minimum IP 66 and IK 08 Protection. Internal Surge protection of 4KV and External surge protection of 10/20 KV in minimum required. The LED's used in the luminaries shall be high power with power consumption between 1W to 5W with CRI greater than 80 in 5700K CCT. The luminaries shall be designed to ensure lumen depreciation L70 over min. 50000 burning hours as per LM 80 report. The luminaries should have fins on the back to ensure good heat dissipation and to prevent dirt from settling on the luminaries along with aiming angle scale shall have a power factor >0.95 and THD<10% and suitable for an operating voltage range of 140- 277V AC and cutoff at >300V AC and self . Product Catalogue, LM79, LM80 shall be submitted. Make: Approved by engineer in-charge.
OD83571/2025-2026 : SKF OD : Supply, Installation, Testing and Commissioning of Outdoor Lighting Panel (ODP) cubicle type IP65/IP55, totally enclosed, pedestal mounted, free standing with top canopy, dust and vermin proof, water proof suitable for operation on 3 phase, 415 V, 50Hz AC supply fabricated using 2mm thick CRCA sheet, powder coated, including internal wiring with suitable size wires/cable, interconnection, duly powder coated painting etc. The work shall be completed with all other accessories as per approved SLD. The firm should have CPRI Certification. INCOMER 63 A/40A, FP,18kA MCCB - 1 No.63 Amp TPN bus bars INSTRUMENTS; Surge protection device -Type 1+2 Voltage protection level should not be less than 1.5 kV , 40A 4P MCB (incoming side of SPD), 4A, C curve SP MCB - 3 Nos, RYB indication lamp. OUTGOINGS 6A to 32 A, 'C'; Curve SP MCB - 32 Nos (arranged by 4X8).
OD83572/2025-2026 : SKF OD: Supply, installation, testing and commissioning of Outdoor Type Floor Mounting KSEB metering panel, suitable for accommodating 3 Phase Energy meter and consisting of 3 nos. of 40 A/63A cutout with HRC fuse( or as per KSEB) , neutral link in separate chamber, inter connections, provision for CT chamber, 63 A SFU-1 no and separate cabin shall be provided in outdoor panel to accommodate VDB/DB (Min. 6Way) as per the requirement etc. as required, and including necessary supports of floor or wall mounting as required, and the panel fabricated out of 14 SWG CRCA sheet with lockable door with sealing facility having glass window for energy meter, sealing facility for KSEB, top canopy and necessary overhang, undergone seven tank process ,powder coated finish and all mounting accessories as required, The firm should have CPRI Certification
90.11.1.14 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)
90.12.1.40 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).4 core 10 sq mm
90.12.1.41 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).4 core 16 sq mm
90.12.1.42 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).4 core 25 sq mm
90.16.1.2 : Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2. 65 mm copper conductor (12 SWG)
90.16.1.3 : Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
90.6.5.12 : Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 2.50 sq mm
2.10.1 : Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
2.10.4 : Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole
2.13.2 : Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
2.15.3 : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli Amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps
9.1.20 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X25 sq.mm (28mm)
9.1.32 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)
9.1.33 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)
5.1 : Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required
5.15 : Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
OD83576/2025-2026 : SKF OD : Earthing with G.I. earth pipe 2.5 meter long, 40 mm dia including accessories, with providing masonry enclosure with cover plate / FRP Earth Pit Chamber. ( but without charcoal/ coke and salt ) etc as required
St.joseph Constructions (BID ID -2268353)
Bidder Name
St.joseph Constructions
PRIMETECH ENGINEERING
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1275126.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .