Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.5 LAccepted-AOC | L1 | Accepted-AOC Being lowest bidder | |
| 2 | L2₹21.4 L+₹2.9 L (15.7%)Rejected-Finance 12 BHARTI AARTIST COLONY VIKAS MARG NEW DELHI 110092 | EAST | DELHI | 110092 | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹22.2 L+₹3.7 L (20.3%)Rejected-Finance 1ST FLOOR H NO 165 GALI NO 16 S B S COLONY KARAWAL NAGAR DELHI EAST DELHI DELHI 110094 | NORTH EAST DELHI | DELHI | 110094 | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹24.1 L+₹5.6 L (30.3%)Rejected-Finance 04 L BLOCK MARKET SECTOR 11 NOIDA 201301 UP GAUTAM BUDHA NAGAR | GAUTAM BUDDHA NAGAR | UTTAR PRADESH | 201301 | L4 | Rejected-Finance Other than lowest bidder | |
| 5 | L5₹26 L+₹7.5 L (40.6%)Rejected-Finance DOOR NO 2 31 23 SECTOR 7 SBI COLONY MVP VISAKHAPATNAM 530 017 | VISAKHAPATANAM | ANDHRA PRADESH | 530017 | L5 | Rejected-Finance Other than lowest bidder |
| Sl No | Description | Qty | Unit | R. S. Associates L3 | Bharat Enterprises L1 | DHEER ENGINEERING L6 | Vijaypower Generators Limited L2 | GEPS PROJECTS L4 | Jain Traders L7 | M/s SS Engineering Enterprises L5 | M/S Konark Electric Sales Corporation L8 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Supply, Installation, testing and commissioning of retrofit emission control device (RECD) based on catalytic conversion technology for 82.5 KVA diesel generator set suitable to reduce particular matter (PM 2.5), Carbon Monoxide and Hydrocarbons emitted from Diesel Engine. Retrofit device is to be installed in place of existing silencer. No soot is to be collected in the retrofit device. The device including enclosure should include an Oxidation chamber and Passive Regeneration Trap. RECD shall be suitable to reduce Min Particular Matter Reduction 85%, Min Carbon Monoxide Reduction 90% and Min Hydrocarbon Reduction 90%. Maximum back pressure exerted by the Emission Control retrofit device at max prescribed load by DG OEM (as per the capacity of the DG set) should be under limit and display panel to be provided for back pressure and exhaust temperature limit complete all as specified and directed.
Make of RECD : Manufacturer certified for RECD's applicable to DG Engine as per CPCB norms.
Notes:-
(i) Type Approval & COP Compliance: A valid Type Approval Certificate and Conformity of Production (COP) issued by a recognized agency must be submitted with tech bid to confirm compliance with prescribed emission norms.
(ii) Device should be as per the System and Procedure of Central Pollution Control Board for Emission Compliance Testing of Retro-fit Emission Control Devices (RECD) For Diesel Power Generating Set Engines, Dated 01/02/2022, vide Pollution Control Series PCLS/12/2021-22
(iii) Noise Test Reports: Noise test reports from any CPCB-approved laboratory for RECDs up to 500 KVA should be submitted before commission of RECD.
(iv) National Accreditation Board for Testing and Calibration Laboratories (NABL) testing certificate before and after installation of RECD in the device should be provided by the contractor. The rate of the test shall deemed to be included in the quoted rate by the contractor. | 1 | Each | 1,96,400 ₹1,96,400 | 1,83,600 ₹1,83,600 Lowest | 2,51,600 ₹2,51,600 | 2,25,000 ₹2,25,000 | 2,60,000 ₹2,60,000 | 2,69,000 ₹2,69,000 | 2,00,000 ₹2,00,000 | 4,00,000 ₹4,00,000 |
| 1.01(v) Device should be 'Type Approved' as per the System and Procedure of Central Pollution Control Board for Emission ComplianceTesting of Retro-fit Emission Control Devices (RECD) for Diesel Power Generating Set Engines Dated 01/02/2022, vide Pollution Control Series PCLS/ 12/2021-22. Adhering to this, RECD to be 'Type Tested for an equivalent KVA family as per the System and Procedure from any one of the four Central Pollution Control Board. Govt of India recognized/ approved test agencies/ laboratories as given below:- (a) Automative Research Association of India, Pune (Maharashtra) (b) International Centre for Automotive Technology, Manesar (Haryana) (c) Indian Oil Corporation, Research and Development Centre, Faridabad (Haryana) (d) Indian Institute of Petroleum, Dehradun (Uttarakhand) (e) Vehicle Research Development Establishment, Ahmednagar (Maharashtra) (vi) General Technical Requirements (GTR)/ Commissoning:- (a) Emission Control retrofit device shall be complete with safety precautions to ensure no damage should be done to the DG set operations under any circumstances. The Emission Control retrofit device should be closely coupied with the DG exhaust to ensure 100% of teh exhaust passses through the Emisson Control retrofit device. (b) Anit Vibration mountings shall be provided for complete Emission Control retrofit device in case of flexible coupling with the diesel generator exhaust. (c) Emission Control retrofit device should have protection against under voltage, over voltage, under frequency, over frequency, new battery voltage, over current, earth-fault, short circuit, phase sequence change etc. (d) The Emission Control retrofit device shall be with corrosion resitive and HR paint. (e) The contractor shall provide the trial run (Testing) of Emisson Control retrofit device. The contractor shall conduct trial run of the Emission Control retrofit device with the available electrical load at site. The trial run shall be for Two hours. The electrical loading shall not be more than the rated capacity of the DG set. (f) Exhaust piping, civil work, distribution board and other any mounting/accessories shall be provided by the contractor and shall be included in quoted rates. | |||||||||||
| 2.00 | All as per Srl Item No. 1.00 here in before but for capacity 65.5 KVA DG Set. | 3 | Each | 1,96,400 ₹5,89,200 | 1,62,900 ₹4,88,700 Lowest | 2,27,000 ₹6,81,000 | 1,90,000 ₹5,70,000 | 2,00,000 ₹6,00,000 | 2,49,000 ₹7,47,000 | 2,00,000 ₹6,00,000 | 3,00,000 ₹9,00,000 |
| 3.00 | All as per Srl Item No. 1.00 here in before but for capacity 50 KVA DG Set. | 4 | Each | 1,79,500 ₹7,18,000 | 1,41,300 ₹5,65,200 Lowest | 2,08,500 ₹8,34,000 | 1,65,000 ₹6,60,000 | 1,90,000 ₹7,60,000 | 2,29,000 ₹9,16,000 | 2,00,000 ₹8,00,000 | 2,50,000 ₹10,00,000 |
| 4.00 | All as per Srl Item No. 1.00 here in before but for capacity 40 KVA DG Set. | 1 | Each | 1,54,200 ₹1,54,200 | 1,33,200 ₹1,33,200 Lowest | 1,80,000 ₹1,80,000 | 1,55,000 ₹1,55,000 | 1,80,000 ₹1,80,000 | 1,99,000 ₹1,99,000 | 2,00,000 ₹2,00,000 | 2,50,000 ₹2,50,000 |
| 5.00 | All as per Srl Item No. 1.00 here in before but for capacity 30 KVA DG Set. | 2 | Each | 1,45,800 ₹2,91,600 | 1,24,200 ₹2,48,400 Lowest | 1,70,000 ₹3,40,000 | 1,35,000 ₹2,70,000 | 1,65,000 ₹3,30,000 | 1,99,000 ₹3,98,000 | 2,00,000 ₹4,00,000 | 1,90,000 ₹3,80,000 |
| 6.00 | All as per Srl Item No. 1.00 here in before but for capacity 20 KVA DG Set. | 2 | Each | 1,37,400 ₹2,74,800 | 1,15,200 ₹2,30,400 Lowest | 1,65,000 ₹3,30,000 | 1,30,000 ₹2,60,000 | 1,40,000 ₹2,80,000 | 1,99,000 ₹3,98,000 | 2,00,000 ₹4,00,000 | 1,70,000 ₹3,40,000 |
Tender Value
₹36.8 L
EMD Value
₹73,600
Closing Date
4 Dec 2025, 6:00 pmClosed
GE UTILITY AMBALA
GE UTILITY AMBALA CANTT 133001
REPAIR PROVN OF RETROFIT EMISSION CONTROL DEVICE RECD IN DG SETS OF WATER SUPPLY AND SEWAGE INSTALLATION UNDER GE UTILITY AMBALA CANTT
2025_MES_739447_1
CA NO GE U AMB 66 OF 2025-26
Open Tender
Civil Works
Item Rate
240 days
GE UTILITY AMBALA CANTT
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
GE UTILITY AMBALA CANTT
₹73,600
7 Jan 2026
12 Nov 2025
6 Dec 2025
12 Nov 2025
4 Dec 2025
27 Nov 2025
12 Nov 2025 - 19 Nov 2025
Amount
Supply, Installation, testing and commissioning of retrofit emission control device (RECD) based on catalytic conversion technology for 82.5 KVA diesel generator set suitable to reduce particular matter (PM 2.5), Carbon Monoxide and Hydrocarbons emitted from Diesel Engine. Retrofit device is to be installed in place of existing silencer. No soot is to be collected in the retrofit device. The device including enclosure should include an Oxidation chamber and Passive Regeneration Trap. RECD shall be suitable to reduce Min Particular Matter Reduction 85%, Min Carbon Monoxide Reduction 90% and Min Hydrocarbon Reduction 90%. Maximum back pressure exerted by the Emission Control retrofit device at max prescribed load by DG OEM (as per the capacity of the DG set) should be under limit and display panel to be provided for back pressure and exhaust temperature limit complete all as specified and directed. Make of RECD : Manufacturer certified for RECD's applicable to DG Engine as per CPCB norms. Notes:- (i) Type Approval & COP Compliance: A valid Type Approval Certificate and Conformity of Production (COP) issued by a recognized agency must be submitted with tech bid to confirm compliance with prescribed emission norms. (ii) Device should be as per the System and Procedure of Central Pollution Control Board for Emission Compliance Testing of Retro-fit Emission Control Devices (RECD) For Diesel Power Generating Set Engines, Dated 01/02/2022, vide Pollution Control Series PCLS/12/2021-22 (iii) Noise Test Reports: Noise test reports from any CPCB-approved laboratory for RECDs up to 500 KVA should be submitted before commission of RECD. (iv) National Accreditation Board for Testing and Calibration Laboratories (NABL) testing certificate before and after installation of RECD in the device should be provided by the contractor. The rate of the test shall deemed to be included in the quoted rate by the contractor.
(v) Device should be 'Type Approved' as per the System and Procedure of Central Pollution Control Board for Emission ComplianceTesting of Retro-fit Emission Control Devices (RECD) for Diesel Power Generating Set Engines Dated 01/02/2022, vide Pollution Control Series PCLS/ 12/2021-22. Adhering to this, RECD to be 'Type Tested for an equivalent KVA family as per the System and Procedure from any one of the four Central Pollution Control Board. Govt of India recognized/ approved test agencies/ laboratories as given below:- (a) Automative Research Association of India, Pune (Maharashtra) (b) International Centre for Automotive Technology, Manesar (Haryana) (c) Indian Oil Corporation, Research and Development Centre, Faridabad (Haryana) (d) Indian Institute of Petroleum, Dehradun (Uttarakhand) (e) Vehicle Research Development Establishment, Ahmednagar (Maharashtra) (vi) General Technical Requirements (GTR)/ Commissoning:- (a) Emission Control retrofit device shall be complete with safety precautions to ensure no damage should be done to the DG set operations under any circumstances. The Emission Control retrofit device should be closely coupied with the DG exhaust to ensure 100% of teh exhaust passses through the Emisson Control retrofit device. (b) Anit Vibration mountings shall be provided for complete Emission Control retrofit device in case of flexible coupling with the diesel generator exhaust. (c) Emission Control retrofit device should have protection against under voltage, over voltage, under frequency, over frequency, new battery voltage, over current, earth-fault, short circuit, phase sequence change etc. (d) The Emission Control retrofit device shall be with corrosion resitive and HR paint. (e) The contractor shall provide the trial run (Testing) of Emisson Control retrofit device. The contractor shall conduct trial run of the Emission Control retrofit device with the available electrical load at site. The trial run shall be for Two hours. The electrical loading shall not be more than the rated capacity of the DG set. (f) Exhaust piping, civil work, distribution board and other any mounting/accessories shall be provided by the contractor and shall be included in quoted rates.
All as per Srl Item No. 1.00 here in before but for capacity 65.5 KVA DG Set.
All as per Srl Item No. 1.00 here in before but for capacity 50 KVA DG Set.
All as per Srl Item No. 1.00 here in before but for capacity 40 KVA DG Set.
All as per Srl Item No. 1.00 here in before but for capacity 30 KVA DG Set.
All as per Srl Item No. 1.00 here in before but for capacity 20 KVA DG Set.
Vijaypower Generators Limited (BID ID -3489855)
R. S. Associates (BID ID -3489966)
GEPS PROJECTS (BID ID -3490366)
M/s SS Engineering Enterprises (BID ID -3492235)
DHEER ENGINEERING (BID ID -3488814)
Jain Traders (BID ID -3490716)
M/S Konark Electric Sales Corporation (BID ID -3492342)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.52 MB
Tender.pdf
Tender Documents • 0.38 MB
BOQ_827988.xls
BOQ • 0.54 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .