Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹20.5 LAccepted-AOC | ₹20.5 L | L-1 | Accepted-AOC As per CWC-I held on dated 21/06/2025 |
| 2 | L-2₹21.2 L+₹76,585 (3.74%)Rejected-AOC | ₹21.2 L+₹76,585 (3.74%) | L-2 | Rejected-AOC As per CWC-I held on dated 21/06/2025 |
| 3 | L-3₹22.1 L+₹1.6 L (7.94%)Rejected-AOC | ₹22.1 L+₹1.6 L (7.94%) | L-3 | Rejected-AOC As per CWC-I held on dated 21/06/2025 |
| 4 | L-4₹22.6 L+₹2.1 L (10.5%)Rejected-AOC | ₹22.6 L+₹2.1 L (10.5%) | L-4 | Rejected-AOC As per CWC-I held on dated 21/06/2025 |
Tender Value
₹24.9 L
EMD Value
₹50,000
Closing Date
28 Apr 2025, 3:00 pmClosed
CHIEF GENERAL MANAGER
O.F.Bhandara
Repairing of electric wiring, switches, holders, Power Supply system, digging and laying of underground cables, street lights, LP finals etc in the area of R substation inside factory area bldgs., at O.F. Bhandara.
2025_MIL_232967_1
EO/51/RD2414/BF
Open Tender
Electrical Works
Item Rate
365 days
O.F.Bhandara
AS per Tender document
7 documents required · 7 mandatory
₹0
₹50,000
Yes
26 Jun 2025
17 Apr 2025
30 Apr 2025
17 Apr 2025
28 Apr 2025
17 Apr 2025
Amount
S & F of modular switch one way 10 amp,1 module, make -Cona/Legrand/C&S/Havells/Anchor or equivalent.
S & F of modular switch one way 16 amp,1 module, make -Cona/Legrand/C&S/Havells/Anchor or equivalent.
S & F of modular socket , multipurpose 3 pin,6/16A amp combined make -Cona/Legrand/C&S/Havells/Anchor or equivalent.
S & F of modular Bell push 6 Amp ,1 module , make -Cona/Legrand/C&S/Havells/Anchor or equivalent.
S & F of modular socket , 6A - 2 &3 pin combined 2 module . make -Cona/Legrand/C&S/ Havells/Anchor or equivalent.. (As per directed by EIC)
S & F Bell push ,flush type , 5 Amp, make -Cona/Legrand/C&S/Havells/ Anchor or equivalent.
S & F Switch piano flush button single pole one way 5 Amp, Anchor /CONA/Havells/ Legrand make or equivalent make.
S & F Switch socket combination 3 pin, flush type,5 Amp, Anchor /CONA/Havells/ Legrand or equivalent make
S & F Switch socket combination 2 in 1 ,3 Pin, 5 and 15 Amp flush type universal, Anchor /Cona/Havells/ Legrand make or equivalent make
S & F Lamp Holder PVC /Poly carbonate type, Angle / batten type . Anchor /CONA/Havells/ Legrand Make or equivalent.
S & F celing rose,2/3 point/PVC/Polycarbonate ,isolated body.Anchor /CONA/Havells/ Legrand Makeor equivalent make
S & F of Bell / Buzzer/Ding Dong bell etc., AC,230 Volts
Fixing of repaired ceiling fan and connecting up including provision of cable from ceiling rose or connector to fan.
Fixing of Exhaust Fan and connecting up including provision of cable from ceiling rose or connector to fan
S & F Air termination ,single point aluminium rod 12 mm Dia,300 mm Long
S & F Aluminium strip 25 X 3.15 mm with saddles and fixing screws etc. for roof conductors and down conductors above ground for Lightning conductors.
S & F only Earth continuity conductor,25 X4 mm G.I strip on wall /recess/chases/buried in ground/drawn in conduit or pipe etc as directed by EIC.
Supply & Fixing for wiring for circuit/ submain wiring along with earthwire with the following sizes of FR PVC insulated copper conductor (multistrand), make :-Polycab/Finolex/V-Guard/HPL/L&T or equivalent, single core cable in surface / recessed( concealed) as required in steel conduit, size 2 x 1.5 sq. mm + 1 x 1.0 sq. mm earth wire ( suitable metal union and bend should be provided) Steel conduit should be FLP type / Heavy duty .
Taking down carefully copper/aluminium point wiring (light,fan, socket or power) complete, ( fittings such as switches,ceiling roses,pendants,regulators, sockets etc to be measured separaetly ) removing materials to store for keeping in safe custody for re-use at site and making good disturbed surfaces of walls ,floors etc.
Taking down carefully by unscrewing from boards/out-let boxes ,fittings and fixtures such as switches,sockets,ceiling roses,lamp holders,brakets,ceiling fittings,bulk head fittings, tube light fittings and regulators etc. for re-use at site or carrying to the store ( to be measured only when found serciable in all respects complete for re-use)
M&L point wiring for one light point or one fan point controlled by one switch with 2.5 sq mm copper conductor,1100 V, FR PVC insulated cable Polycab/Finolex/HPL/V-Gaurd make or equivalent in PVC conduit with 1.5 sq.mm copper FR PVC insulated earth conductor & accessories.
M&L point wiring for one light point or one fan point controlled by one switch with 1.5 sq mm copper conductor,1100 V, FR PVC insulated cable, Polycab/Finolex/HPL/V-Gaurd make or equivalent in PVC conduit with 1.0 sq.mm copper FR PVC insulated earth conductor & accessories.
M & L for wiring for circuit/submain wiring alongwith earthwire with the 2 X 1.5 sq.mm+1X1.0 sq.mm earth wire of FR PVC insulated copper conductor,Polycab/Finolex/HPL/V-Gaurd make or equivalent , single core cable in surface/recessed and in steel conduit.
M & L for wiring for circuit/submain wiring alongwith earthwire with the 2 * 2.5 sq.mm+1*1.5 sq.mm earth wire of FR PVC insulated copper conductor, Polycab/Finolex/HPL/V-Gaurd make or equivalent ,single core cable in surface/recessed and in steel conduit.
M & L for earthing complete with using steel earth plate electrode 60x60 cm x6 mm thick ,buried directly in ground ( earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level, connected to galvanised strip 32x6 mm as earthing lead by means of bolts,nuts,ckeck nuts and washers of galvanised iron or steel including upto 7.5 mtr length/test point as per IS:3043/1987 and SSR-2020 Plate no.3 & indicated including testing on completion and as directed by EIC
Excavation in hard dense soil 1.5 mtr wide & 2.5 mtr deep for earth pits
Supply & fixing of G,I Pipe medium grade 25 mm Dia with GI nuts & bolts ,2 nos of clamp ,funnel etc as watering pipe in earth pits.
Material and labour for PCC of 1:2 : 4 of type B -2 Using 40mm graded aggregate for making foundation of LP finilal/steel tubelar swaged pole .
demolition /dismantelling cement concrete(unreinforced) in building pavements,gantries up to 15 cms thick (below or above ground level)
Painting of steel & Iron surfaces ( Electrical apparatus like Street Light DBs, HT/ LT Panels,Feeder Pillars ,Transformers etc. ) and one coat of synthetic enamel light grey /smoke grey /siemens grey colour . ( Whenever required painting shall be done through applying Suitable Painting Brush /Spray painting or as directed by EIC.)
Rough excavation intrenches not exceeding 1.5 wide and not exceeding 1.5 m in depth in hard dense soil and getting out for laying of cable
back filling of excavation including soft soil/loose soil spreading, levelling, watering and well ramming in layers not exc 25 cm.
M & L for sand filling in cable trench.
M & L for reinforced precast concreate cable covers, class LV, Type 1, flat, size 250 x 150x 40mm.
supply and fixing of GI pipe medium grade 80 mm dia under road / culvert etc.
Supply & fixing of support/clamp of MS angle 50x50x6mm size and back/top plate(size 50x50x6mm) fabricated from structural steel section inclding barass or stainless steel nut,bolt,washer,welding,bending cold or hot,drilling holes with drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, oneunder coat and one finishing coat ofpaint(as directed by EIC/SIC).
Supply & Fixing 9 mtr long steel tubelar swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP-31 with painting and as per directed by EIC.
supplying and fixing 1100 volt grade heavy duty cable PVCinsulated 4.0 sq.mm aluminium solid conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 meter apart including 4 mm suspension wire one twin core cable flat or circular
Supply and Laying in trench/ fixing of cable on wall using saddles and making connection, XLPE insulated heavy duty ,XLPE electric cables with Aluminium Conductor, Size 4 C x 10 sq.mm ,1100 Volt grade, GI strip/wire armoured and with cable size, make and length marking on every 1 meter of cable conforming to IS:7098 (part-I) .Make-Gloster/ Polycab/ Uniflex/Havells or equivalent.
M&L for plate, plane or chequrred ,Fe 410-W (Gde-E- 250 ) quality-A, not less than 10mm channels square cut or notch ( ordinary and counter sunk) forming holes 18mm and with proper continuos seam welding(as directed by EIC/SIC).
M&L for Round blocks 10 CM dia and 5 CM depth or equivalent
Fixing back in due repairs to Switch unit/ Switch fuse unit (DP/TPN fused and neutral link), any voltage, any Amp.
Fixing back with due repairs Replacement of Bulb/CFL/T-5/LED lamp, LED Tube light only ( Materials will be provided by Factory)
Repairing & fixing back of Flamepoof & weatherproof rotary type switch/switch socket combination,16A, 250V , double pole of any make or as directed by EIC. ( Material will be provided by OFBa)
Fixing only Flameproof junction boxes up to 100/120 mm dia, 2/4 way ( Material will be provided by OFBA)
Fixing only single /double compressor gland FLP/NON FLP size 19/25 mm dia
Repairing /replacement of LED/CFL lamps of FLP/WP well glass/bulk head fittings or as directed by EIC ( Material Will be provided by OFBa)
Repairing of FLP/WP tube light fitting by replacing LED tube provided by O.F.Bhandara at various locations as directed by EIC.
Removing & Fixing back with due repairs HPSV/HPMV/MH/FTL/LED Street light fitting/SEARCH LIGHT of any rating including replacement of LED panel , Driver etc of any wattage rating .( Materials will be provided by O.F.Bhandara)
Taking down tube light fitting, FLP (1 x 40 W) for repairing.
Repairing of FTL fitting, FLP(1 x 40 W) by replacing tube,electronic choke,rotor holder etc.
Fixing back FTL tube light fitting, FLP (1x 40 W) for repairing.
Fixing only well glass LED light fitting 1x35W ,FLP-WP as per directed by EIC /site incharge.
M & L for sheet metal enclosure DB for MCBs SPN 2 way, single phase and neutral. HPL/Havells / L& T or its equivalent .
M & L for sheet metal enclosure DB for MCBs 4 way,415V, 200A bus bar,Tripple pole and neutral, Double door.HPL/Havells / L & T or its equivalent.
supply & Fixing outdoor type distribution box made out of CRCA sheet metal 2mm thick on pole 415 V consisting of 1 nos. of 63 A connector and one no. of 6 A MCB SPN with bottom cable plate drilled, danger sticker 415 V and fixed with rubber gourments. the DB cover will have lockable arrangements. The DB should CRCA sheet metal 2mm thick, on pole;size-300x300x150 mm, 2 Nos. of GI clamp of 25 X 5mm dully painted to be provided to fixed the DB on pole.
supply & Fixing of straight through heat shrinkable cable jointing kit suitable for 10 sq.mm-25 sqmm XLPE LT cable 4 core. Make REPL/Raychem RPG/3-M or equivalent.
supply & Fixing straight through heat shrinkable cable jointing kit suitable for 95 sq.mm to 400 sq.mm XLPE LT cable 3.5 core. Make REPL/Raychem RPG/3-Mor equivalent.
supply & Fixing straight through heat shrinkable cable jointing kit suitable for 35 sq.mm-70 sqmm XLPE LT cable 4 core. Make REPL/Raychem RPG/3-Mor equivalent.
Shifting & Laying in cable trench / fixing by means G.I Saddle of LT Cables Sizes from 1.5 Sq.mm to 25 Sq.mm ( Cable will be provided by O.F.Bhandara).
Shifting & Laying in cable trench / fixing by means G.I Saddle of LT Cables Sizes from 35 Sq.mm to 400 Sq.mm ( Cable will be provided by O.F.Bhandara).
Maintenance and testing of LT Air Circuit Breakers in sub-stations (Range 630A to 4000 A).
S & F of open type PVC Modular plate with PVC surface frame 12 module make - Cona/ Legrad/C&S/Havells/ Anchor or equivailent ( as per directed by EIC)
S & F of open type PVC Modular plate with PVC surface frame 8 module make - Cona/ Legrad/C&S/Havells/ Anchor or equivailent ( as per directed by EIC)
S & F of G.I pipe medium grade 25 mm dia with GI nuts & bolts, 2 nos clamp and 1.5 mtr, bent to shape as per required for bracket of street light /perimeter light ( as per directed by EIC)
S & F of FRP / DMC conical insulator M6*30 HT, rated volt 440 V, test volt 2 KV for 1 min, size base diameter 30 mm, height not less than 60 mm from base, top face diameter not less than 20 mm effective threaded length not less than 8 to 10 mm with brass /stainless steel nut, bolt & washer.( fixing of insulator as directed by EIC)
S & F of FRP / DMC conical insulator M12*60 HT, rated volt 440 V, test volt 2 KV for 1 min, size base diameter 60 mm, height not less than 60 mm from base, top face diameter not less than 40 mm effective threaded length not less than 16 to 19 mm with brass /stainless steel nut, bolt & washer.( fixing of insulator as directed by EIC)
S & F of Bombay nail 100mm length as directed by EIC /SIC
repairing /replacement of existing Air termination ,single point aluminium rod 12 mm Dia,1.5 m Long ( materials will be provided by factory))
Supply & Fixing of separator / Insulator for LP strip , Power earthing strip as per directed by EIC
Supply & fixing of 3 core 1.5 sq. mm flexible multistrand copper cable ( as per directed by EIC)
M B ELECTRICALS (BID ID -844006)
RAJESH ELECTRICAL CONSTRUCTION (BID ID -843520)
PEEW PREM ELECTRICAL ENGG. WORKS PVT. LTD. (BID ID -845405)
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .