CONSTRUCTION AND IMPLIMENTATION WORK OF THE CONTINUUM BUILDING AT INDIAN INSTITUTE OF MANAGEMENT AHMEDABAD
2020_IIMA_599763_1
IIMA/Contracts/TW-030A/2020-21
Open Tender
Civil Works - Buildings
545 days
INDIAN INSTITUTE OF MANAGEMENT AHMEDABAD
As per NIT Chapter-1
5 documents required · 5 mandatory
₹0
Exempted
INDIAN INSTITUTE OF MANAGEMENT AHMEDABAD
3 Mar 2022
28 Nov 2020
22 Dec 2020
28 Nov 2020
21 Dec 2020
14 Dec 2020
28 Nov 2020 - 8 Dec 2020
8 Dec 2020
Amount
PILE WORK
Providing, driving and installing driven cast-in-situ reinforced cement concrete piles of grade M-25 of specified diameter and length below the pile cap, to carry safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of shoe and the length of pile to be embedded in the pile cap etc. all complete. (Length of pile for payment shall be measured from top of shoe to the bottom of pile cap) :
600 mm dia piles
EARTH WORK Note : Incase of over excavation, it need to be filled with Plum concrete (1:4:8) having no extra cost.
Mass Excavation including backfilling (include obtaining permission of Govt. authority and paying fees / royalty if any also providing debris management and submitting plan to local authority) in all kinds of soil, wet or dry (such as yellow murrum, hard murrum / gravel or mixture of any kind, etc.), in loose and slushy condition, including soft rock, to the required level by mechanical equipments (JCB / Poclain) for foundation trenches, rafts of walls, plinths, including carting away and disposing off surplus excavated material (outside IIMA Campus at locations approved by local authority as per their rule) as directed by PM including removal of vegetation, shrubs and debris, spreading, levelling, watering and compacting in layer not exceeding 150mm in depth in each layer and stacking of excavated material for back filling within the premises; if required, dewatering by bailing/pumping out water to keep the site dry at all times, making temporary stepping / sloping, shoring with planking, strutting, sectioning, trimming, dressing of sides, levelling or grading, cleaning, removing and excavating loose pockets and consolidating them by backfilling as directed by the PM. Further Rate shall include manual excavation and final dressing to arrive at required level. Rate should include breaking clods, watering, compacting each layer with vibratory compactor and at inaccessible places with wooden/steel rammers to achieve 95% proctor density at optimum moisture content; dressing up embankments; if required, bailing/pumping out of water to keep site dry while back filling; costs includes conveyance of all materials, labour, machinery etc. complete. Rate shall also inclusive of removal of foundation of existing boundary wall.
Up to 0.00 M TO 1.5 M
From 1.5M to 3.00 M
From 3.00 M to 4.50 M
From 4.50 M to 6.00 M
Providing, diluting and injecting chemical emulsion for pre-constructional anti-termite treatment and creating a continuous chemical barrier under and around the column pits, wall trenches, basement excavation, top surface of plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surroundings of pipes and conduits etc. complete. Work to be carried out as per IS : 6313 (Part II), as per approved manufacturer's instructions and recommendation, and installed by manufacturer's approved agency with a guarantee of 10 years, all to the satisfaction of the PM. (Plinth area in plan at ground level shall be measured for payment).
STRUCTURAL WORK CEMENT CONCRETE (CAST – IN- SITU)
Providing, machine mixing and laying Plain cement concrete (PCC) of required thickness including compacting, curing, dewatering where required and vibrating, cleaning, preparing surfaces, junctions, etc.; complete at all depths and leads as per the drawing and to entire satisfaction of the Engineer in-charge.
1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size)
REINFORCEMENT CEMENT CONCRETE WORK Centering and shuttering including strutting, propping etc. and removal of form for all heights :
Foundations, footings, bases of columns, columns, beams, plinth / tie beams, slab etc.
Lintels, beams, plinth beams, girders, bressumers and cantilevers.
Columns, Pillars, Piers, Abutments, Posts and Struts.
Providing, transporting to site, storing, de-coiling (if required), straightening, cutting, bending, spirally hooping, binding and placing, in position reinforcement bars, to correct shape and size as per detailed drawings, specifications, preparing and getting approved bar-bending schedules for all reinforced concrete works with correct size of heavy duty PVC / concrete (of same grade of concrete) cover blocks and galvanized binding wire of 18 gauge, required dewatering, provide required labour and machines / equipment / tools / tackles for handling, shifting, bending, binding, etc. The rate shall include cost of concrete cover blocks, binding wire, all chairs, spacers and pins etc. all complete to the satisfaction of the PM at all depths, height, lift & leads.
Corrosion Resistance Steel with (Fe 500D) having chemical composition of Carbon - 0.25% (Max), Sulphur - 0.04% (Max), Phosphorus - 0.04% (Max) and Copper - 0.40% (Min)
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge at all heights, lead and lifts. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess / less cement used as per design mix shall not be payable/recoverable separately). Note:- Soft water shall be used for Concrete having pH 7 to 7.5
Extra for providing richer mixes at all floor levels.
Providing M-30 grade concrete instead of M-25 grade BMC / RMC. (Note:- Cement content considered in M-30 is @ 340 kg/cum. Excess / less cement used as per design mix shall not be payable/recoverable separately)
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement
1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size)
Providing, fabricating, erecting and fixing in position designed approved brand formwork system using 18mm thick plastic coated shuttering plywood PERI make or equivalent, shuttering giving fair finish concrete surfaces, making leak proof joints, using required couplers, tie bolts, M.S. ties, concrete spacer wheels or SS spacers, providing openings / cut-outs / pockets, niches, grooves, drip course, etc.; using required deshuttering emulsion which will not stain the concrete, etc. complete at all height, depths, lead & lift and required any height staging and supporting sturdy and braced. Also include removing & dismantling the aforesaid assembly after specified or as approved period from the day of casting of concrete. Shuttering design shall take into account staging, supporting, grooves as required in single or double row, construction joints in shape and forms as detailed in the Architectural drawing. The Contractor shall prepare and submit to the Architect/ EIC shuttering drawings showing mould details, its fixing, finish, construction joints proposed, leak proofing etc. all complete to the satisfaction of the Architect/ Project. The shuttering thickness, support and bracing should be as per shop drawings submitted by contractor & approved by the structural engineer. (Maximum no. of uses - 2) (Note : Diamond Core cutting / making opening for AC ducts, sleeves etc. shall not be paid extra) (For Exposed concrete)
Providing and fixing of expansion joint system related with floor location as per drawings and direction of Engineer-In-Charge. The joints system will be of extruded aluminium base members, self aligning / self centering arrangement and support plates etc. as per ASTM B221-02. The system shall be such that it provides floor to floor /floor to wall expansion control system for various vertical location in load application areas that accommodates multi directional seismic movement without stress to it’s components. System shall consist of metal profiles with a universal aluminium base member designed to accommodate various project conditions and finish floor treatments. The cover plate shall be designed of width and thickness required to satisfy projects movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self-centering arrangement that freely rotates / moves in all directions. The Self –centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminium extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. Provision of Moisture Barrier Membrane in the Joint System to have watertight joint is mandatory requirement all as per the manufactures design and as approved by Engineer -in-Charge . (Material shall confirm to ASTM 6063.)
Floor Joint of 100 mm gap
Providing and Filling the gap of expansion joint by weather/ structural non sag elastomeric PU sealant with application of primer including scraping/ removing the expansion filler materials from joints, cleaning, repairing of the edges with epoxy mortar of approved color and make, placing over backer rod of approved make and required size, fixing of abro tapes on the edges to prevent the adjoining surface, at all levels/ all floors / all height etc. complete as directed by Engineer-in-charge.
Size of expansion joint 25mm x 13 mm
Providing and fixing Premoulded Compressible, high performance closed cell, bitumen free expansion joint filler board of specified thickness in black colour of approved make, having minimum density 95 Kg/Cum, Non Staining with less than 1% water absorption & compression recovery of 93% minimum as per specifications including cutting to required size and shape, at all levels/ all floors/ all heights, etc. complete, as per drawings/ specification and as directed by Engineer In Charge.
i) 75 mm thick filler board
Preparing shop drawings, obtaining Structural Consultant's approval, designing, providing, transporting, fabricating in accordance with IS:800, delivering at site, hoisting and fixing in position at all locations and levels, including all temporary staging and supporting work and making all structural steel work in accordance with the design, drawings prepared by the Consultants. The rate of steel work shall include cutting, grinding, machining, assembly, welding, jointing, of single / building up new sections etc., cost of fasteners (nuts, bolts and washers), pre-heating the sections to temperatures up to 250oC if thickness of the section is equal to or more than 25 mm. Fabrication will involve connections using plates, channels and angles, gusset plate, foundation bolts, cleats, fasteners, stiffeners etc. as per drawing, steel conforming to IS : 226 and IS : 2062 with minimum yield strength of 250 Mpa. The rate shall also include one coat of zinc rich primer after properly cleaning the steel surface with wire brush and mild acid solution followed by washing with water and drying the surface completely, to be applied to individual fabricated parts of the structure prior to their erection & assembly in their final place. The rate shall also include the synthetic enamel paint system in approved shade and of approved make as per recommendations of paint manufacturer to the approval of PM.a) All structural steel (minimum 250 Mpa grade) in the form of plates, angels, box sections, channels, RS joists etc. shall conform to IS : 2062.
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone - III) : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
Providing and fixing Medium duty injection adhesive of approved make for rebar fixing in Dry conditions for below specified dia. Drilling hole to the required depth by rotary hammer drill, cleaning with brush and jet of clean air, filling resin and hardener with standard dispenser in hole and then fixing the re-bar, The system should be made of two foils consisting of resin and Hardener foil pack. The installation and the setting instructions should be strictly followed as per the manufacturers recommendations. Rate shall be inclusive of scaffolding and for all places and all heights etc. and work shall be carried out as per direction of Engineer. Reinforcements shall be paid in relevant tender item. (Pull out testing up to 1% of total rebar is to be produced by manufacturer)
8 mm dia bar
10 mm dia bar
12 mm dia bar
16 mm dia bar
20 mm dia bar
25 mm dia bar
Above 50mm to 75mm dia
Above 75mm to 100mm dia
Above 100mm to 150mm dia
BRICK WORK
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :
Cement mortar 1:4 (1 cement : 4 coarse sand)
Extra for brick work / AAC block masonry in superstructure above floor V level, for each four floors or part thereof by mechanical means.
Providing and laying autoclaved aerated cement blocks masonry with 100mm/ 150mm/230mm/300 mm thick AAC blocks in below plinth/ super structure at all levels with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer in- Charge.
Providing and constructing about Exposed brick masonry with approved quality modular exposed bricks of having minimum crushing strength of 5 N/sqm and water absorption maximum 10% of approved manufacturer as per sample approval by the Architect/ Project manager; for walls, columns, arches etc. including preparing surfaces, cleaning, , soaking/wetting, doing sample layout for approval of the Architect/ Engineer in charge prior to execution of main work. Masonry to be carried out with cement mortar 1:5 (Cement : 5 Coarse Sand) mixed with approved non-shrinking compound as per manufacturer’s instruction in specified courses of approved bond, raking out joints, cleaning, curing, clear pointing all complete as per specifications etc. at all heights, depths and leads. Joints in the exposed brick work shall be truly horizontal and vertical and kept uniform with the help of wooden or steel strips. The thickness of joints shall be 10mm. all in required line, level and plumb as per details / specifications / instructions, at all heights and leads, required double legged / Mason's scaffolding, tools / plants / tackles all complete. Further, masonry to be cured for at-least 7 days and then doing Beaded (extruded) pointing with cement mortar mix 1:2 (1 Cement : 2 Fine Sand) including grinding the exposed brick surface smooth and edges sharp as detailed to the approval. (Note: Contractor to protect work in progress or completed work till satisfactory handing over the work; without any extra cost) Also rate shall inclusive of providing and applying Hydrophobic Silane -Siloxane coating of Wacker BS-209 or approved equivalent make, to exposed brick masonry surfaces at all heights & leads and wherever instructed by Engineer-In-Charge. The treatment shall be in two coats wet-on-wet or as recommended by approved manufacturer including preparation of surfaces by cleaning, curing, protecting, independent double legged scaffolding etc complete. The rate includes the cost of all materials, its application by specialized applicators by spray coating with airless sprayer, cleaning the substrate of all laitance, construction dust, contaminants, double scaffolding, labour etc., all complete and at all levels, leads and heights as per particular specification & directions of EIC. Guarantee Bond in the prescribed proforma shall be executed by the contractor for the satisfactory performance of the application for 10 years.
Fixing available (stacked at site) Precast coping (Approx. 365mm wide x 90mm thick)in place as directed by Engineer in charge over 12 mm (average) thick base of cement mortar 1:5 (1 cement : 5 coarse sand) with joints finished flush.
WOOD AND PVC WORK
Providing & fixing SS 304 grade push-pull pair of handle made out of satin (brush) finish of approved make with necessary screws etc. complete for wooden doors/ aluminium doors/ metal doors as per drawing as approved by Engineer-in-charge. Rate shall be for all heights, all floors and all places. The length of handle should be perfect center to center as below specified. Eden Pull Handle (ED 12 P SS) fixed with SS screws etc. complete in all respects as per manufacturers' specifications.
Eden Pull Handle (ED 12 P SS)
Providing and fixing approved brand and manufacture Mortice Dead lock (ML102SS from Dorset) having 50mm Backset along with key cylinder fixing option along with Euro Profile Cylinder one side coin and one side Knob 60 mm (CL202SS Dorset) fixed with SS screws etc. Complete in all respects as per manufacturers' specifications and as directed by Engineer-in-charge.
Providing and fixing aluminium die cast body tubular type universal Fire Rated hydraulic door closer (FR80PDC from Dorset) (2 Hrs fire Rated) (having brand logo , embossed on the body, door weight up to 80 kg , 5 lacs Cycles Tested), with speed adjustment along with necessary accessories and screws etc. complete as per Engg. in charge
Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (DC80PDC from Dorset) (having brand logo, embossed on the body, door weight up to 80 kg, 5 lacs Cycles Tested), with speed adjustment along with necessary accessories and screws etc. complete as per Engg. in charge
Providing and fixing Mortise shaft dead bolt with key in stainless steel, SS brush finish lock as per fire norm. (8681 from DORMA) with necessary screws etc. complete as per Engg. in charge.
Providing and fixing panic bar / latch of Dorma PHCR 1-1200 series Panic Hardware consisting of Main Panic Latch, End Component, Push Bar, Striker kit, End Caps in silver finish. Complete set with screws and fixing accessories. + DORMA PHCRT 2905 External Trim Lever Type with cylinder including two keys. Finish- Silver complete set including Spindle screws and all fixing accessories as per Engg. in charge
Providing & fixing of specified height (minimum rod size shall be 10mm) SS 304 brush finish Tower bolt (barrel type) of approved make in aluminium doors/ metal doors with necessary screws etc complete as approved by Engineer-in-charge.
a) 300 mm x10 mm rod size
b) 250mm x10 mm rod size
Providing and fixing approved brand and manufacture SS304 graded or Buffer wall mounted 22 mm dia, 75 mm long (DBWC (22)) with Cover fixed with SS screws etc. complete in all respects as per manufacturers' specifications & as directed by Engineer-in-charge (Dorset)
Providing and fixing DORMA Kick plate 1020-1 with smoothened edges and rounded corners flush face fixing screws height 300mm and thickness 0.9mm in SS304 grade in satin stainless steel. Length=5mm short of the shutter width. Max door width = 900 mm as per Engg.- in - charge.
Providing and fixing SS brush finish Oval shape Concealed Handle with required accessories in order to be fixed to metal door (1207 from Dorma) as per Engg. - in -charge.
Providing and fixing RP 120 Long Double Doorset from Raven with required accessories as per Engg. - in -charge.
Providing and fixing Mortise Sash Lock of Stainless Steel along with Euro Profile Cylinder (One Side Key & Knob) and a pair of handles of (Dorset MLEDASS) along with SS screws etc. Complete in all respects as per manufacturers' specifications and as directed by Engineer-in-charge.
Providing and fixing Hollow metal fire rated doors as per IS 3614 part-2 for stability and integrity. Pressed Galvanized steel confirming to IS 277 with the following specification. Recommended fire door shall have doors tested at CBRI against Test Schedule Ref No FR/0046 for maximum rating of 2hrs tested. Doors shall be finished in Thermosetting Powder Coating desired RAL Shades. Manufacturer test certificate shall cover doors both single & double leaf doors and Hardware should pass European certificate "CE" of conformity / UL with required fire ratings. Any deviation in specification and sheet thickness other than what is mentioned in the test certificates are not allowed. Door frame shall be single rebate profile of section 100 x 57 mm made out of 1.20mm thick galvanized steel sheet with a factory pre-punched groove so as to accommodate Fire & smoke seal size 10x4mm. Frames shall be butt jointed and field assembled with bolting system for proper strength. The frames shall be finished with Thermosetting Powder Coating in desired RAL Shade. All provision should be mortised, drilled and tapped for receiving appropriate hardware. Frames should be provided with back plate bracket and anchor fasteners for installation on a finished plastered masonry wall opening. The edges should be interlocked with a bending radius of 1.4mm. For pair of doors astragals has to be provided on the meeting stile for both active and inactive leaf. Shutter shall be fixed to frame with 120 min fire rated SS 304 Ball Bearing Butt Hinges of size 100mm x 75mm x 3 mm CE marked (no of hinge as suggested by Engineer In Charge). Shutter shall be with bottom seal of approved make as per manufacturer's specification. Door leaf shall be minimum 46mm thick fully flush double skin door with or without vision lite. Door leaf shall be manufactured from 0.8mm (22 gauge) minimum thick galvanized steel sheet. The internal construction of the door should be rigid reinforcement pads for receiving appropriate hardware. The infill material shall be Rockwool treated with Viper FRS 881 LH. All doors NSD 12049 shall be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers. The edges should be interlocked with a bending radius of 1.4mm. Vision lite wherever applicable should be provided as per manufacturers recommendation with a beading and screws from inside. Door shutter shall be finished with etched primer coating, stove zinc phosphate primer and thermosetting polyurethane aliphatic grade paint of approved color. The door leaf and frame shall have passed minimum 250 hours of salt spray test as per the directions of Engineer - in- charge. Rate shall be inclusive of shutter with infill material, bottom seal, hinge, finishing cost and installation but excluding the cost of Vision panel and all hardware.
Providing and fixing glazing in fire resistant door shutters, fixed panels & partitions etc., with G.I. beading made out of 1.6 mm thick G.I. sheet (zinc coating not less than 120 gm./m²) of size 20 x 33 mm screwed with M4 x 38 mm SS screws at distance 75 mm from the edges and 150 mm c/c, including applying a coat of approved fire resistant primer/ powder coating of not less than 30 micron on G.I. beading, & special ceramic tape of 5 x 20 mm size etc. complete in all respect as per NBC 2016, IS 16231 (Part 3):2016 and as per direction of Engineer-in charge with glass of required thickness having 120 minutes of fire resistance both integrity & radiation control (EW120) and minimum 20 minutes of insulation (EI20). The manufacturer have to give test report/certification of fire glass and the glass should have the stamp showing the value of E, EW & EI. The glass shall be tested in approved NABL accredited lab or by any other accreditation body which operates in accordance with ISO/IEC 17011 and accredits labs as per ISO/IEC 17025 for testing and calibration scopes shall be eligible. The maximum glazing size shall not be more than 1100x2200 mm (w x h) or 2.42 Sqm.
Providing and fixing ISI marked 35mm thick flush door shutters (including SS butt hinges with screws) conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters including pressed steel frame, 2nd class teak wood lipping and 1mm thick high pressure laminate as per followings a) Pressed steel door frames (Profile B) conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge fixed with adjustable lugs with split end tail to each jamb. b) Lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters c) 1mm thick decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality.
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.
In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.
80x1.25 mm M.S. laths with 1.25 mm thick top cover
Providing and fixing ball bearing for rolling shutters.
Extra for providing grilled rolling shutters manufactured out of 8 mm dia M.S. bar instead of laths as per design approved by Engineer-in- charge, (area of grill to be measured).
Providing & fixing Divyang Toilet set with European Closet (P Trap) & wall mount wash basin & all divyang requirements with dual flush tank, seat & lead (heavy duty) including C.I. Brackets, C.P. brass hinges, M.S. / C.I. painted brackets, 32mm CP waste Coupling, 32mm size CP bottle trap, CP brass Spatula Faucet, etc. all Internal fittings complete with S.S grab rails etc. rubber buffers, C.P nuts, bolts etc. making holes in walls & floors, & finishing for ready to use. The rate includes all necessary connection charges as per product detail to the satisfaction and as directed by the Engineer-in-charge.
Providing & fixing Fire Barrier mortar with minimum 2 hours fire rating when tested in accordance with BS 476 part 20 and UL 1479 for horizontal openings in fire rated floors or slabs and vertical openings in walls for passing service shafts. The service lines could be of various types like electrical cables trays, metal pipes, Ducts for AC, etc. The product shall be age tested as per Dafstb and DIBT standards. The product should be tested for mould resistance rating of 0 as determined by ASTM G21-96. The product shall be tested and approved by third party agencies such as UL and FM. The mortar should be tested in accordance with IEC 60068-2-57:1999-11 (Environmental Testing) as per Part 2-57: Test for Vibration-Time-history method and VERTEQII for relevant seismic zone. The product shall bear the UL and FM approval logo on the packing where applicable.
FLOORING flooring (for all type of flooring) shall be as drawing provided by Architect. The contractor shall prepare mock-up prior to execution of work for the approval of the architect/EIC.
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :
a) Mirror polished minimum 25mm to 30mm thick (550mm x 550mm size)
b) Honed finish minimum 25mm to 30mm thick (1000x300mm size)
Kota stone slabs 20 mm thick in risers of steps, dado, skirting and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.
a)Mirror polished minimum 25mm to 30mm thick
b) Honed finish minimum 25mm to 30mm thick
Making 3 nos. of anti skid grooves 3mm x 3mm deep on top of stair case tread at front as shown in the drawing in kota / granite stone. (Measurement will be done in Rmt for a set of 3 no grooves together)
Providing and laying tactile tile (for vision impaired persons as per standards) of size 300x300x9.8mm having with water absorption less than 0.5% and conforming to IS:15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge.
Providing & laying in required position flooring / finishing layer of broken china mosaic in white colour (broken pieces of glazed tiles 15mm and above but less than 40mm in size) over brickbat coba as per item 1.0 above or any other location in palin / curved surfaces as directed, including bedding mortar of 1 : 6 (1 cement : 6 Coarse Sand) admixed with pure acrylic Polymer Modified Cementitious water proofing compound (pure acrylic co-polymer), grey cement slurry @ 2.75kg per sqm, filling the joints with white cement, giving proper slopes, compaction with wooden rammer, rounding of the junctions and extending upto 15 cm along the parapet wall, curing, finishing and cleaning with oxalic acid etc. complete as directed by the engineer-in-charge. (Only plan area shall be measured for the payment.)
Providing and laying vitrified floor tiles (any texture glossy/ matt/ anti skid) in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours, texture and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/Sqm including grouting the joints with white cement and matching pigments and with necessary cutting for floor trap etc., complete.(Consider Basic rate of Vitrified tile Rs. 100/- per Sqft.)
a) With vitrified tile of size 600 x 600 mm of same product batch, even shade and as per approved sample.
Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colors such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/Sqm including pointing the joints with white cement and matching pigment etc., complete. (Consider Basic rate of Ceramic tile Rs. 80/- per Sqft.)
Providing and fixing Its quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer) of approved make in all colors, shades except burgundy, bottle green, black of 600mm x 300mm size as approved by Engineer-in-Charge, in skirting, risers of steps and dados with cement based high polymer modified quick-set tile adhesive (Water based) conforming to IS: 15477, in average 3mm thickness including pointing in white cement mixed with pigment of matching shade and with necessary making holes for tap etc., complete.(Consider Basic rate of Ceramic tile Rs. 80/- per Sqft.)
a) 300mm x 300mm size Ceramic tile
b) 300mm x 600mm size Ceramic tile
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Also including edge moulding to 18 mm thick granite stone counters including machine polishing to edge to give high gloss finish etc. and fixing granite stone facia and drops of width upto 150 mm with epoxy resin based adhesive, including cleaning etc. complete as per design approved by Engineer-in-Charge. Further providing opening of required size & shape for wash basin sink in vanity counter in Granite including necessary holes Granite of any color and shade for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. (Consider Basic rate of Granite Rs. 150/- per Sqft.)
Area of slab over 0.50 Sqm
Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth. (Consider Basic rate of Granite Rs. 150/- per Sqft.)
Granite Stone of approved shade
Providing and laying Polished Granite stone flooring / treads in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. (Consider Basic rate of Granite Rs. 150/- per Sqft.)
Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
Providing and fixing Granite stone slabs 18 mm thick in risers of steps, dado, skirting and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. (Consider Basic rate of Granite Rs. 150/- per Sqft.)
Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer's specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.
Providing and installing 15mm thick Mikasa or equivalent make Engineered Wooden flooring with plank width of 185mm / 135mm and length of 1800mm / 2100mm and top layer up to 3mm Oak natural Veneer. Surface of Top layer shall be pre-finished with several layer of UV hardened Acrylic lacquer. Strictly Free from Formaldehyde and solvents. Flooring plank shall be interlocked using Plank Lock locking system in a glue less floating manner. Engineered wood planks shall be a composition of 3 layer of Pine wood with direction of each layer oriented at right angle to the adjacent layer of natural strain in Lacquer and Non Bevelled / Bevelled in length and width as specified by the approved manufacturer's specification and as per Engineer-in-charge.
Providing and fixing 15mm thick Mikasa or equivalent make Engineered Wood Stair Nose with Plank LOC Locking system on both the edges so as to make it easier to lock as it at the same level as that of floor once locked. The top layer up to 3mm Oak/Walnut natural Veneer etc. as specified by the approved manufacturer's specification and as per Engineer-in-charge. Also providing and fixing staircase edge lipping (4mm thick x 40mm wide) where one or both sides of the stairs are exposed.
Providing and laying approved Red Dholpur stone (matching with existing stone shade) flooring / treads in required design and patterns, all complete as per the architectural drawings with 25 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:5 (1 cement : 5 coarse sand) with joints finished flush etc. all complete as specified and as directed by the Engineer-in-Charge.
Providing & laying approved Red Dholpur stone flooring 25 to 32 mm thick laid as per existing pattern & size over average 20 mm thick cement mortar bedding 1:5 (1 cement : 5 coarse sand) including filling joints with cement slurry pigmented to match the shade of the slabs
Providing and laying ready to fix lawn turf in slabs or rolls- spreading layer of red hill earth and cow dung manure mixture in 2:1 proportion up to 30cm depth and laying of carpet lawn/passlum lawn over it complete as drawing with levelling, watering and rolling etc. complete.
FINISHING WORKS
Providing and applying Hydrophobic Silane - Siloxane coating of Wacker BS-290 make or approved equivalent make, to exposed concrete surfaces at all heights & leads and wherever instructed by Engineer-In-Charge. The treatment shall be in two coats wet-on-wet or as recommended by approved manufacturer including preparation of surfaces by cleaning, curing, protecting, independent double legged scaffolding etc complete. The rate includes the cost of all materials, its application by specialized applicators by spray coating with airless sprayer, cleaning the substrate of all laitance, construction dust, contaminants, double scaffolding, labour etc., all complete and at all levels, leads and heights as per particular specification & directions of EIC. Guarantee Bond in the prescribed proforma shall be executed by the contractor for the satisfactory performance of the application for 7 years.
Providing and applying 12mm thick plaster in cement mortar mix ratio CM 1:4 (1 cement : 4 sand) mixed with approved polypropylene fibres as per instruction of the approved manufacturer, to internal surfaces of concrete and masonry work; including raking out joints, hacking concrete surfaces and applying approved chemical bonding agent and applying a scratch coat over concrete surfaces by bonding / adhesive chemical coat as directed by approved manufacturer to create a key, cleaning / grooving deep junctions of concrete & masonry, grouting them back by mortar mixed with non shrinking compound along with packing of clean, fresh square cut aggregate; further providing 150mm wide 20 gauge GI chicken mesh at junctions of concrete and masonry work, including preparing and finishing jambs, sills, grooves, pattas, wattas, rounding of corners, etc. all complete as per architectural drawings, specifications and finished smooth with wooden rundha etc. or as specified by the PM at all leads, depth and lifts, doing independent double-legged scaffolding, cleaning of surfaces, curing, etc. complete as per specification and to the approval of the PM.
Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :
Two or more coats on new work
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :
New work (two or more coats) over and including water tinnable priming coat with cement primer
Finishing walls with water proofing cement paint of required shade :
New work (Two or more coats applied @ 3.84 kg/10 Sqm)
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :
Two or more coats on new work (on MS railing)
Providing and fixing Toilet cubical systems of approved equivalent make and manufactured in standard dimensions of 600mm ± 10mm width door size with 12mm thick solid Compact Laminate panels made of KRAFT paper impregnated with Phenolic resins under high pressure and temperature, including doors, pilasters & intermediate panels, which should be resistant to heat, bacteria, water, chemical, scratch and impact. Finished product should be as per approved texture, shade & drawing, detailing and developed according to IS-2046 and BS-476/97 standards. The toilet cubicle setup shall include necessary hardware fittings, made out of stainless steel (Grade-304), as per manufacturer’s specifications and approved by Engineer-in-charge. Hardware fittings should consist of (1) Stainless steel Adjustable foot/ pedestal of SS 316 grade to give 150mm clearance from bottom and of weight not less than 600grams (2) Stainless steel U-channels of 20 gauge and 12 x 20mm size (3) Stainless steel Top rail pipe (OD:24mm of 18 gauge) with corner connectors (4) Stainless Steel Head Rail Tubular Holder (5) Stainless steel Gravity hinges (3 nos.) not less than 75mm length and weight not less than 210 grams of weight not less than 200 grams. (6) Stainless steel Coat hook with nylon door stopper (7) Stainless steel Door knob (8) Stainless steel Thumb-turn lockset with occupancy indicators (9) Wall bracket SS 304 (10) Corner Connector (11) Rubber noise deafening tape (12) Stainless steel 304 Screws and PVC wall plugs. The top fitting arrangement shall comprise of stainless steel (round) top rail, fixed to pilasters and stainless steel tubular holder. Stainless steel wall fixing roses shall be used on the wall to hold the top rail. In absence of brick walls, stainless steel corner bends (connected to the top rail) will be used on the corners of the cubicle. All screws should be of stainless steel (Grade-304). All pilasters will be supported by stainless steel adjustable foot. The base of the stainless steel bottom cladding will be anchored to the floor with a clearance height of 150mm.The intermediate panel shall be of one continuous panel without any joint. All visible edges will be chamfered.
a) L-Shape Toilet cubicle with standard dimensions of 2000 ± 25mm (Height) x 1000mm (Width) x 1550mm (Depth) consisting of 600 ± 10 mm width of door. The rate includes cost of 12mm Solid compact laminate board along with all necessary fixtures mentioned above
Fire Paint & Primer Works Step 1 (Done at paint booth / closed premises (fabrication yard) Supply and applying fire retardant paint comprising of the following :- Surface treatment: -Abrasive blast cleaning as per ISO 8501-1988 to SA 2 1/2 Standard. 1st Coat: Providing & applying Two Component Zinc Phosphate cured Epoxy Primer. The primer shall be applied by airless spray. Brush shall be used for strip coatings to cover edges, weld seams,etc.The Dry film thickness (DFT thickness) shall be 75 microns. For Internal Surface :The recoat interval shall be maximum 10 Hrs at 23 Deg C . External Surface : Minimum recoat interval of not more than 2 hrs at 23 Deg C. Step 2 (Done at site - post erection) 2nd Coat :- Solvent Born or Water Born thin film single pack (from one part material) Intumescent Paint of approved make. The number of coatings and DFT (Dry film thickness) shall be as per particular specifications provided and manufacturer's specification to meet fire rating mentioned below: Finish Coat :- One-pack hard and glossy topcoat Poly Urethane based paint with good weather resistance (VOC Less than 250 g/l as per EPA method 24).The product hard dry time should not be more than 1.5 hrs @ 23 degree C. The Dry Film thickness shall be 60microns.The product should exhibit Gloss between 88% to 90% as per ASTM D 523 and gloss retention of a minimum 80% after 2000 hrs, exposure to UV-A Florescent lamp, as per ASTM D 587. The rate includes cost of preparation surface for receiving intumescent paint, including cost of supplying and applying a mist coat of suitable surface tolerant primer at site before applying fire paint, cost of all paints i.e. both Intumescent paint and PU paint, all cost of application of both Intumescent paint and PU paint,cost of all scaffolding, labour charges for working at all leads, levels & heights etc. complete as per particular specifications & as per direction of Engineer-In-Charge. The certificate of fire rating as per approved norms shall be submitted by the contrcatorin approved format. Measurement: Surface Area painted (only exposed area i.e. one time measurement after completion of Top coat) shall be measured and paid.
Fire rating of 120 minutes
WATERPROOFING WORK
Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc. consisting of following operations: a) Applying a slurry coat of neat cement using 2.75 kg/Sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls up to 300 mm height including cleaning the surface before treatment. b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls up to 300 mm height including rounding of junctions of walls and slabs c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ Sqm of cement admixed joint less cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer in-Charge :
With average thickness of 120 mm and minimum thickness at khurra as 65 mm.
Providing and laying of light weight Concrete fill on structural slab using light weight aggregates of perlite having higher compressive strength and highest fire resistance with thermal / acoustic insulation properties, anti-corrosion, anti-condensation, etc. of perlite in the required proportion to get the desired density, mixing, transportation, placing, compacting and finishing to the required level with necessary side supports, equipments, etc. complete. Rate shall include for preparation of surface, protecting the laid pipes and sanitary fittings, finishing the surface smooth to receive the top coat of water proofing application etc. complete and all as directed by Engineer in-charge. (600 Kg/ Cum density)
Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/Sqm mixed with water proofing cement compound @ 0.253 kg/Sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg/Sqm mixed with water proofing cement compound @ 0.126 kg/Sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.
Providing and filling light weight AAC bats (of size 40-60 mm) with cement mortar mixed in the ratio 1:3:6 (1 cement : 3 coarse sand : 6 block bats) including mixing of approved water proofing compound in recommended proportion. The laid brick bat mix shall be well rammed and compacted as required. Further surfaces shall be screened with cement concrete mix 1:1.5:3 (1 cement : 1.5 coarse sand : 3 stone grit of size 6 mm and below by volume) admixed with approved integral water proofing compound in recommended proportion, laid to an average thickness of 25mm and finished smooth or ready to receive finish material as specified. Care shall be taken prior to filling all pipes passing through sunk portion such that the pipes are pressure tested by maintaining pressure for 24 hours and junctions of pipes passing through walls, slabs are well grouted and sealed. This shall be tested by ponding water for required depth and maintaining for 72 hours.(Rate includes cost of AAC bats, cement mortar, top screed, labour charges for working at all levels, leads and heights). For payment the area of sunken slab and the depth of filling including the thickness of screed shall be measured.
Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservoir, sewage & water treatment plant, tunnels/ subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fibre brush. The material shall meet the requirements as specified in ACI - 212-3R-2010 i.e. by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guaranteed for 10 years against any leakage.
For vertical surface two coats @0.70 kg per Sqm per coat (Location:-Water tanks)
For horizontal surface one coat @1.10 kg per Sqm.(Location:-Water tanks)
Providing and applying of swellable type water stop tape, 19mm x 25mm thick in linear meter (expansive nature) for construction joints treatment of RCC structure such as raft slab, retaining walls, water storage tank and at the junctions of raft slab with the retaining walls etc.. After cleaning the surface, one coat of required primer for swellable water stop tape shall be applied throughout the length of the joint @3.78 litre per 240 running meter. Over the primed surface swellable type water stop tape shall be placed. The work shall be carried out all complete as per specification and the direction of the Engineer-In-Charge. The product performance shall carry guarantee for 10 years against any leakage.
ROOFING & CEILING
Providing and fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanizing @ 120 grams per Sqm including both side) consisting of main 'T' runner suitably spaced at joints to get required length and of size 24x38mm made from 0.33 mm thick (minimum) sheet,pre-coated steel of size (24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450mm centre to centre with 25mm spaced 1200mm centre to centre, and cross "T" of size 24x28mm made out of 0.33mm (Minimum) sheet, 1200mm long spaced between main 'T' at 600mm centre to centre to form a grid of 1200x600mm and secondary cross 'T' of length 600mm and size 24 x 28mm made of 0.33mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600mm panel to from grid of size 600x600mm, resting on periphery walls /partitions on a Perimeter wall angle long dry wall screws @ 230mm interval and laying 15mm thick densified edges calcium silicate ceiling tiles of approved texture (Spintone / Cosmos/hexa) in the grid including, cutting/ making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required, Main 'T' runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6mm fixed to ceiling with 12.5 mm dia and 50mm long dash fasteners, 4mm G.I. adjustable rods with galvanized steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200mm centre to centre along main 'T' , bottom exposed with 24mm of all T-sections shall be pre-painted with polyester baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-charge Note :- Only calcium silicate false ceiling area shall be measured from wall to wall. No deduction shall be made for exposed frames/opening (cut outs) having area less than 0.30 sqm. The calcium silicate ceiling tile shall have NRC. value of 0.50 (Minimum), light reflection > 85%, non - combustible as per B.S. 476 part IV, 100% humidity resistance and also having thermal conductivity < 0.043 w/m 0 KC.
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with :
12.5 mm thick tapered edge gypsum moisture resistant board
PLUMBING WORKS
SUB-HEAD: I :SANITARY INSTALLATION :-
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug & 40mm waste coupling including painting of fittings and brackets, cutting and making good the walls wherever required. ( make- JAYNA CAT. MODEL SBSD 09 A (DX))
Kitchen sink with drain board, 510 x 404 mm bowl depth 250 mm
Providing & fixing white vitreous china Wall hung type European type water closet with C.P. bolts, nuts with hanging arrangement, including solid plastic seat and cover with lid, C.P. brass hinge rubber buffers, with accessories,i/c fixing with nuts & bolts drilled & grouted to walls at required spacing, including cutting and making good the wall and floors wherever required. (Make:HINDWARE ESSENCE 92051 with Seat cover and Accessories Or Equivalent model of Cera or Parryware).
Providing and Fixing Concealed in wall Flush, flush valve with auto stop function, noise less and fast action with all component parts of high quality complete including fixing .(Make:JAQUAR FLV-1095SQ Or Equivalent model of Cera or Parryware)
Providing and Fixing Vitreous china Counter based Wash Basin of size 580 x 430 mm with brackets painted white and connection pipe to wall with C.P. wall flange and rubber adopter for waste connection complete, including cutting and making good the walls wherever required .(Make - HINDWARE IMMACULA 91205 Or Equivalent model of Parryware)
Providing and fixing of C.P./S.S. waste Coupling for wash basin suitable with oval type wash basin including all necessary fittings making good wherever required complete as per instructions of the engineer-in-charge (Make-HINDWARE F850002 Equivalent model of Cera or Parryware)
Providing and Fixing vitreous china flat back urinal of size: 610x410x380 mm with CP Cast Bottle Trap, C.I. hangers, 15mm dia inlet to built in spreaders with inbuilt waste with C.P flange, complete including cutting and making good the walls and floors wherever required .(Make: HINDWARE DYNA STANDARD URINAL (ART) STARWHITE-60010 , Cera cat no 5001 Or Equivalent model of Parryware & Bottle Trap: Vijay "ADS” 565 & 552 Or Equivalent model of Hindware ,Cera or Parryware)
Providing and Fixing electrical operated concealed automatic flushing system for urinals, including front S.S plate 125 x 125mm chrome sensor with CP brass body, ball valve etc,complete in all respect including cutting and making good the walls wherever required electrical connection complete. (Make: HINDWARE ELECTRIC SENSOR Or Equivalent model of Cera or Parryware)
Providing and Fixing CP Bottle Trap with 300 mm long connection pipe and wall flange 32 mm size complete as per instructions of the engineer-in-charge (Make: HINDWARE F-850015 Or Equivalent model of Jaquar & Parryware)
Providing and fixing manual CP soap dispenser with liquid soap (including one time soap fill) including cutting and making good the walls, wherever required complete as per instructions of the engineer-in-charge (Make: Jaquar Cat No:SDR-WHT-DJ0010F OR Vijay Cat No: 428 OR Equivalent) (For Common Toilet)
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 (Make: JAQUAR FLR-5053N or equivalent model of Hindware ,Cera or Parryware).
a) 15mm Nominal Bore
Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931(Make: JAQUAR-FLR-5047N. or equivalent model of Hindware ,Cera or Parryware). (For Utility)
a) 15mm Nominal Bore
Providing and Fixing central hole C.P. brass Sink mixer with Swinging Casted spout & connecting legs and flanges and flexible net connection (if required )including cutting and making good the walls wherever required (Make: JAQUAR FLR-5319NB or equivalent model of Hindware ,Cera or Parryware).
Providing and Fixings of 15mm pillar tap for wash basin with flexible net connection of approved quality , including cutting and making good the walls wherever required :(Make-JAQUAR FLR-5011N Or Equivalent model of hindware & Parryware).
Providing and fixing straight/offset type Macfit single body push fit type WC Pan Connector with factory supplied spring loaded seal guard with integrated single mould sealing fins made of flexible EVA Body, including bush/adaptor for use with CI Pipe as supplied with Pan Connector (For European water closet) [Make : McAlpine, UK/Equivalent].
Providing and fixing of CP brass health Faucet with 1.5 mtr long flexible tube, wall hook, spray nozzle , wall flange etc., complete all accessories of approved make. (Jaquar Cat No .ALD-CHR-573)
Providing, of vertical / horizontal storage type hot water heater fixed to wall with anchor bolts & nuts, 20mm CP brass cock and 20mm non return valve complete including making connection with 15 mm dia CP connecting pipe on Inlet and Outlet, suitable length of power cable and 15A plough (for kitchen & Toilets). Make-Jaquar INSTA (3L)/ Havells/ Racold
Providing and fixing C.P cast brass Double coat hook fixed to PVC cleats with C.P. brass screws complete as per instructions of the engineer-in-charge (Make: jaquar Cat No:ACN 1161N ,Cera cat no CA 408 Or Equivalent model of Jaquar & Parryware)
Providing & Fixing of C.P brass toilet paper holder Including cutting hole in the masonry/R.C.C wall and making good with cement mortar.
Providing and Fixing Over head shower 100 mm dia with Shower Arm complete as per instructions of the engineer-in-charge (Make:HINDWARE F-160051CP (over head shower ) & HINDWARE F-110023CP(shower arm) Or Equivalent model of Grohe or Kohler).
Providing and Fixing CP wall mixer with facility of over head shower bend with wall flange complete as per instructions of the engineer-in-charge or as per equivalent make .(Make: JAQUAR Florentine Cat No.-FLR-CHR-5281N Or Equivalent model of Grohe or Kohler)
Providing fixing C.P. brass towel rack fixed to wooden cleats with CP brass Screws complete as per instructions of the engineer-in-charge (Make: HINDWARE F840010 Or Equivalent model of Jaquar & Parryware)
Providing and Fixing CP Soap dish complete as per instructions of the engineer-in-charge(Make JAQUAR ACN1131N or equivalent )
SUB-HEAD: II: SOIL WASTE AND VENT PIPE :-
Providing and fixing sound insulated Polypropylene piping (PP) system as per ON EN 1451-Part 1-6 & EN 12056 Part 1-5 EN 752, DIN 1986-100 - class B/D, with 3 layer pipe made of PP-C + PP-MV + PP-C in Blue Ral 5014 (halogen and calcium free) colour, push-fit type, food safe, having high impact and stiffness, offering sound levels of not more than 22 dBA as per DIN 4109 at a flow rate of 4 l/s and having pipe ring stiffness as per 1S0/DIS 9969 and tightness as per EN 1277/B and C and DIN 19560, density of pipe to be 1.25gms/cm3, elongation = 0.05mm/m0K and tensile strength > 24 N/mm2,with all necessary fittings in blue colour, fitted with factory fitted lip ring, inclusive of all necessary specials like bends, tees, offsets, junctions, door piece, cop, etc., laid under the slabs/ Walls , Suspended on ceiling level with suitable clamps, Pedestals and specials curing etc., complete . Fabricated MS bracket of suitable size to be provided for pipes (Pipes for soil , waste vertical shafts) (Pipes for soil , waste , vent & rain water vertical shaft) For soil, waste and vent & Rain water pipes
Providing and fixing Polypropylene P trap (FLOOR TRAP) of self cleaning design with screwed down or hinged grating without vent arm complete including cost of cutting and making good the walls and floors.
Providing and Fixing CP Grating with frame and SS Screws SS heavy duty 140 mm dia including cutting and making good the walls and floors wherever required complete in all respects (Make: Vijay Cat No: 1262 Or Equivalent model of Hindware ,Cera or Parryware).
Providing and fixing uPVC floor drain with supporting clamp ceiling or in sunken portion including cutting and making good the walls and floors wherever required complete in all respects.
100 x50 mm outlet(UPVC. Elbow)
Providing and fixing M.S structural work fabricated from standard sections e.g. M.S rounds, angles, plates, channels, R.S. joints, GI clamps including cutting to size, drilling, welding, insert plates, dash fasteners of required specification in R.C.C. structural masonry members as directed by Engineer- in- charge including cutting and making good the walls and floors and painting with two coats of enamel paint over primer coat after rubbing and cleaning for pipe supports, clamps etc. wherever required .
Providing & laying UPVC pressure pipes of 6Kg/Sq.cm pressure rating class V (IS : 4985-2000) including fittings, tees, bends, clamps, coupling and adaptors supports, and jointing with solvent joint, testing and necessary earth work in excavation, backfilling, disposal of surplus earth with a lead up to 100m complete, compaction and consolidation Including sand bedding all around UPVC pipe & fittings and thrust blocks at bends as per standard design. (For Rain water)
SUB-HEAD: III: INTERNAL WATER SUPPLY :-
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.
20 mm nominal outer dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge..
15 mm nominal outer dia Pipes (Rate only)
25 mm nominal outer dia Pipes
32 mm nominal outer dia Pipes
40 mm nominal outer dia Pipes
50 mm nominal outer dia Pipes
Providing and fixing CPVC (Chlorinated Poly Vinyl Chloride) water supply pipes with pipe as per CTS SDR 11 at working pressure of 400 PSI at 23. Deg.C & 100 PSI AT 82 Deg. C & SCH 40 pipe as per ASTM F441 & fittings as per ASTM F439 shall be used for higher diameter of cPVC pipes & fittings in size 65 mm, 80 mm & 100 mm.using solvent welded CPVC fittings l.e. Tees, Elbows, Couplers, Union, Reducers, brushings etc. including transition fittings connection between CPVC & metal pipe/G.l i.e. Brass Adaptors (Both male & Female threaded) with only CPVC solvent cement with fabricated and subsequently hot dip galvanised clamps / structural steel supports as required / directed at site including cutting chase and fitting the same with cement concrete cement mortar as required. All termination points for installation of faucets shall have brass termination fittings. Installation shall be to the satisfaction of the Engineer-In-Charge. (for domestic and flushing water supply inside the shafts and ceiling floor) Internal work - Inside the shaft & terrace
a) 65 mm dia
b) 80 mm dia
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge..
a) 15 mm dia (Rate only)
b) 20 mm dia
c) 25mm dia
d) 32mm dia
e) 40mm dia
Providing and fixing C.I butterfly valve, wafer end type class PN 1.6 as per I.S:13095 or BS:5155, including necessary nuts, bolts, gaskets, flanges etc., complete as required and as specified.
a) 65 mm nominal bore
b) 80 mm nominal bore
Providing and fixing 750 mm long hot dipped G.I. Puddle flanges for water tanks as per I.S. 1239 (Class C) with 6mm thick M.S. Plate of suitable size and welded all-round the pipe fixed in walls, beams and top slab of R.C.C tanks, complete with all details in all respects and as per drawing.
25 mm dia (6 mm Thick)
32 mm dia (6 mm Thick)
40 mm dia (6 mm Thick)
65 mm dia (8 mm Thick)
80 mm dia (8 mm Thick)
providing and fixing motorised butterfly valve rating PN 1.0 with float type sensors suitable for 240 volts with working pressure rating of not less than 5 kg/cm2 with cont0l panel and sensors to open valve when water level is low in tanks and to close when water level is high in water tanks including butterfly valves, necessary cables, conduits, upto junction box etc. complete. (upto 6 mt qty approx.)
40 mm dia (OHT Filling)
50 mm dia (OHT Filling)
Y - STRAINER of Ductile CI Body flanged ends with stainless steel strainer for chilled / hot water circulation including insulation as specified.
80 mm dia
Supplying and fixing C.I. cover without frame for manholes :
560 mm diameter C.I. cover (heavy duty) the weight of the cover to be not less than 108 kg
SUB-HEAD: IV: EXTERNAL WATER SUPPLY :-
Providing & laying UPVC pressure pipes of 10Kg/Sq.cm pressure rating class V (IS : 4985-2000) including fittings, tees, bends, clamps, coupling and adaptors supports, and jointing with solvent joint, testing and necessary earth work in excavation, backfilling, disposal of surplus earth with a lead up to 100m complete, compaction and consolidation Including sand bedding all around UPVC pipe & fittings and thrust blocks at bends as per standard design. (For Garden Hydrant System) ( External work)
25 mm dia
32 mm dia
65 mm dia
Excavating trenches of required width for pipes, cables, etc, including excavation for sockets, depth upto 1.5 m, including getting out the excavated materials, returning the soil as required in layers not exceeding 20 cm in depth, including consolidating each deposited layers by ramming, watering etc., stacking serviceable material for measurements and Disposal of unserviceable material/Carting away surplus soil outside IIM A Campus at locations approved by local authority as per their rule.
Pipes, cables etc. not exceeding 80 mm dia
Providing & laying UPVC pressure pipes of 10Kg/Sq.cm pressure rating class V (IS : 4985-2000) including fittings, tees, bends, clamps, coupling and adaptors supports, and jointing with solvent joint, testing and necessary earth work in excavation, backfilling, disposal of surplus earth with a lead up to 100m complete, compaction and consolidation Including sand bedding all around UPVC pipe & fittings and thrust blocks at bends as per standard design. (For Garden Hydrant System)
75 mm outer dia
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : (For Garden Hydrant & Riser System)
20 mm dia
40 mm dia
50 mm dia
Providing and fixing C.I butterfly valve, wafer end type class PN 1.6 as per I.S:13095 or BS:5155, including necessary nuts, bolts, gaskets, flanges etc., complete as required and as specified.
a) 65 mm nominal bore
Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design : (For Garden Hydrant System)
With common burnt clay F.P.S.(non modular) bricks of class designation 7.5
Providing and fixing dual plate wafer type C.I. non-return valve conforming to IS: 5312 rated to PN 1.6. with bolts, nuts, 3mm thick gasket and matching flanges as per table 'E' complete.
40 mm nominal bore
50 mm nominal bore
65 mm nominal bore
SUB-HEAD: V: SEWERAGE DRAINAGE :-
Providing and fixing uPVC SN 8 conforming to IS : 15328 PVC-U underground Pipes for sewerage and drainage system including connection to existing sewage network with all fittings with solvent cement joint interconnection complete as directed by manufacturer's /EIC recommendations.
160 mm diameter
200 mm diameter (rate only)
250 mm diameter
300 mm diameter
Excavating trenches of required width for pipes, cables, etc, including excavation for sockets, depth upto 1.5 m, including getting out the excavated materials, returning the soil as required in layers not exceeding 20 cm in depth, including consolidating each deposited layers by ramming, watering etc., stacking serviceable material for measurements and disposal of unserviceable material as directed, within a lead of 50 m : (Disposal of unserviceable material/Carting away surplus soil outside IIM A Campus at locations approved by local authority as per their rule. )
Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia.
Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design :
With common burnt clay F.P.S.(non modular) bricks of class designation 7.5
Constructing brick masonry road gully chamber 50x45x60 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm pre-cast R.C.C. horizontal grating with frame complete as per standard design :
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:
100x100 mm size P type, With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) up to haunches of S.W. pipes including bed concrete as per standard design :
b)160 mm dia diameter
d) 250mm dia diameter
d) 300mm dia diameter (Rate only)
Constructing Brick Masonry Rectangular type manhole 0.9 x 0.8 m internal dimension at bottom and 0.56m dia at top in cement mortar 1:4 (1 cement : 4 Coarse sand), inside cement plaster 12mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size) and making necessary channel in Cement Concrete 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone aggregate 20mm nominal size) finished with a floating coat of neat cement all complete as per standard design. upto 0.91m deep with SFRC cover and frame (heavy duty HD-20 grade designation) 560mm internal diameter conforming to I.S:12592, total weight of cover and frame to be not less than 182Kg. fixed in cement concrete 1:2:4 mix (1 Cement: 2 Coarse sand: 4 Graded stone aggregate 20mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12 mm thick cement plaster at the external surface shall be paid for separately)
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Extra depth for rectangular type manhole 0.9 x 0.8m (at bottom) beyond 0.91m to 2.5m
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Providing and fixing in position, FRP (Fiberglass Reinforced Polymer) Manhole cover with frame design as per EN 124 Standard C250 Class , in removable sections with matching frames of MS angles or making a similar size of offset in floor trimix / concrete, over open channel / chamber as per the drawings and designs and approved by architect and testing of joints complete as per direction of Engineer in Charge. (Basement & ground Civil drain line ).
600 x 600 mm Cover
450 x 450 mm Cover Wide
Rain Water Harvesting system : Providing & constructing brick masonary recharge pit of 2.0m dia x 2.5 m depth with brick work in cement mortar 1:4 (1 cement : 4 coarse sand) with 100mm dia weep holes at side walls @ 500 mm vertically & horizontally center to center, 200 mm thick RCC top slab in cement concrete (1:2:4) along with peripheral & two nos. of intermediate RCC beams of size 250 x 450mm R/ F of slab 12 mm tor steel at bottom and 10 mm at top with a spacing of 125 mm c/c, 4 nos 16 mm tor steel bars at bottom & 2 nos. 12 mm tor steel bars at top for beams with 8 mm stirrups @ 150 mm c/c, 2 nos. heavy duty SFRC cover of 560 mm dia,poly propelene coated rungs @ 300 mm c/c embedded in CC ( 1 : 2 : 4 ) blocks of 200 x 200 x 200 mm, 150 mm thick PCC in 1: 4 : 8 below footing with 150 mm projection, internal & external plaster in CM 1 : 4, necessary excavation, backfilling & disposal of surplus earth upto a lead of 50m complete in all respect as per direction of engineer-in- charge.
De-Silting Chamber: Providing and constructing brick masonry desilting chamber of size 120 x 120 x upto 150 cms depth inside with 75 class designation brick work 345mm/230mm thick in cement mortar 1:4 (1cement:4 coarse sand) with weep holes all around, SFRC cover heavy duty 560mm dia and 150 mm thick R.C.C. top slab 1:2:4 mix(1 Cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) including necessary excavation, back filling, disposal of surplus earth as directed, foundation concrete 1:5:10 mix (1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size) below masonry walls with 150mm projection at either side including necessary baffle wall inside , excavation, back filling and disposal of surplus earth upto a lead of 200 mtr., poly propelene coated rungs @ 300 mm c/c.
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level. All types of soil
300 mm dia
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge.
200 mm nominal size dia
Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete :
For pipes 250 to 300 mm diameter
SUB-HEAD: VI: PUMPING SYSTEM :- Hydro pneumatic Pumping System Hydropneumatics Pumping System
Supply, Installation, Testing and Commissioning of compact packaged type skid mounted, self contained fixed frequency drive hydropneumatics system complete as required & as per specification with the following:- (i) In- line vertical multistage centrifugal clear water pump set with SS-304 casing, SS-304 impeller with SS-316 shaft ,CI base with CED coating complete directly coupled with TEFC induction motor of class "F" insulation & efficiency class EFF-1, 2900rpm, suitable for operation on 415 Volts ±10%, 3 phase, 50 Hz A.C. supply complete. (ii) The entire system shall be mounted on a common base frame i/c common suction and common delivery of G.I heavy class pipe headers with flanges, interconnecting piping with all required Control Valves, Non-return valves, pressure gauge with isolation cock etc. and all required accessories. (iii) Pressure vessel of non corrosive FRP composite construction lined with NSF and/or FDA listed material, like high density polyethylene with fully replaceable polyurethane. Air cell burst pressure of minimum of 5 times the vessel operating pressure and cycle tested for 80,000 cycles with charging connections to discharge pipe line with necessary flanges, gaskets, isolating valve, nuts/ bolts etc. with suitable foundation bolts & other accessories, complete. (iv) Control Panel with programmable logic controller (PLC) for cyclic operation of pumps + Variable Frequency Drive. The Pump working sequence should change after every operation. Contractor overload relays and MCBs should confirm to IEC 898 – 1995/ specifications. Blinking indications for pumps start, trip, low level trip, health supply should be provided in the panel along with the ammeter & voltmeter. Control panel should also consist of cooling fan. (v) Pressure switches bellow type fitted with micro switch and having maximum pressure and differential scale should confirming BS-6134 standards and IP55 protection class. (vi) All required Ball Valves, Non-return valves, flexible connectors etc. and all required accessories, Heavy Duty G.I. Manifold to make the system completely operational as a skid mounted system. Ball valves to be used should be Hot Pressed brass OT-58 with stainless steel ball and P.T.F.E seal and O-Ring. NRVs to be used should be with Springs and O-Ring arrangement. Complete manifold system shall be factory assembled & totally mounted on a common base frame with following duties:
Providing and fixing C.P cast brass Double coat hook fixed to PVC cleats with C.P. brass screws complete as per instructions of the engineer-in-charge (Make: jaquar Cat No:ACN 1161N ,Cera cat no CA 408 Or Equivalent model of Jaquar & Parryware) Domestic Hydropneumatic system from UGT TO OHT Floor Duty of each pump suitable for:- ( CIIE CONTINUUM Block ) No. of Pumps : 2nos. (1 W + 1 S) 1 VFD with Each pump Capacity : 300 LPM Head : 60 Meters Air Vessel : 1 No of Min. 60Liters Cap. Note:-1 set consists of 2 nos. of pumps (1Working + 1Standby+1 Air vessel)
Flushing Hydropneumatic system from TREATED WATER TANK TO OHT Floor Duty of each pump suitable for:- ( CIIE CONTINUUM Block ) No. of Pumps : 2nos. (1 W + 1 S) 1 VFD with Each pump Capacity : 200 LPM Head : 60 Meters Air Vessel : 1 No of Min. 60Liters Cap. Note:-1 set consists of 2 nos. of pumps (1Working + 1Standby+1 Air vessel)
Drainage Sump Pump Providing and fixing compact monoblock dry motor submersible pumps of suitable rating, with non-clog free flow open impeller, solid handling capacity of up to at least 40 mm suitable for operation on 415 volts +10% , 3 Phase, 50Hz, A.C supply, speed 2900 RPM including oil chamber, lowering of pump, M.S. galvanized lifting chain, Foot plate complete. The pump sets shall be supplied with required accessories & as per specification with the following : Necessary cables from pump set to control panel (position of panel marked on enclosed drawings).- 1 Set Electrical control panel suitable for controlling three pumps having all necessary accessories & safety devices of manufacturers specifications and suitable for receiving incomer and outgoing cables complete as reqd (Panels will be installed near each sump as per site conditions). --1 No. Each set consist of 2 nos.of pumps - 1 working & 1 stand by (Complete set as above with 2 nos. pumps including cost for valves, piping, Control Panel and Cabling, Level Controllers etc as required and as specified) 2.The entire system along with pumps & control panel must be sourced from single manufacturer only for unit responsibility. Sump Pump in basement (location : Pump Room )
Discharge: 250 LPM Head : 17 metre HP : 2HP or As required. Casing : Aluminium alloy /C.I Impeller & Shaft: S.S. 410 Solid Handling Capacity: 20 mm Length of GI lifting chain with each pump : 5 Meter. Level controller Quantity : 2 Nos. (1W+1S) Quantity : 2 Nos. (1W+1S)
Supplying, fixing, testing and commissioning of following valves, gauges and strainers for condenser water circulation as per specifications. BUTTERFLY VALVE (MANUAL) with CI body SS disc nitrile sheet & O - ring & PN 16 pressure rating as specified.
65 mm dia
80 mm dia
Providing and fixing gun metal non- return valve of approved quality (screwed end) :
40 mm nominal bore Horizontal
50 mm nominal bore Horizontal
65 mm nominal bore Horizontal
Providing and fixing forged brass Ball valve with forged brass ball suitable for operating pressure of not less than 16 kg / sq.cm of the following size.
25 mm dia
40 mm dia
50 mm dia
Providing and fixing reselient rubber neoprene lined arch vibration eliminators with unit control nuts, bolts, washers, companion flange as per table E complete suitable for working pressure of 15 Kg/sqcm.
40 mm dia
50 mm dia
65 mm dia
Providing and fixing of GI pipe complete with GI fittings and clamps, unions , nut & bolts including cutting and making good the wall as per direction of Engineer in Charge.
Providing and fixing GI pipes confirming to IS: 1239 heavy class complete with G.I. fittings, flanges including painting with enamel paint two or more coats over a coat of red-oxide primer ,cutting and making good the walls wherever required etc., complete.
65 mm dia
80 mm dia
Providing and fixing liquid level controller for pumps including Float type probes, wiring, cable, conduit and making connection to pump panel complete in all respects and making system functional, cutting and making good. To start the pump when water level is low in domestic water tank and to stop the pump when domestic water tank is full. Also to stop the pump when water level is low in raw water tank.
Providing and fixing G.I. fabricated hot dipped galvanized coating puddle flange comprising of 600 mm dia long M.S class 'B' pipe (screwed end up to 50 mm & flange for more than 50 mm dia) with 6 mm thick M.S plates of required size including cutting holes in centre of plate, inserting pipe & making welded (Arc) joint complete. Same shall be installed with TEC welded joint in position with reinforcement bars of RCC tank wall/slab including making cut-out in shuttering during concrete casting of tank of following diameter. (Location: underground tanks.)
25 mm dia (6 mm Thick)
32 mm dia (6 mm Thick)
40 mm dia (6 mm Thick)
50 mm dia (6 mm Thick)
65 mm dia (8 mm Thick)
80 mm dia (8 mm Thick)
100 mm dia (12 mm Thick)
150 mm dia (12 mm Thick)
250 mm dia (12 mm Thick)
Providing and fixing C.I. Y-strainer with nuts, bolts, rubber insertions etc. complete conforming to IS : 2373 :
65 mm dia
80 mm dia
ELECTRIC WORK FOR PLUMBING PUMP ROOM Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
4 x 2.5 sq. mm
3 x 4 sq. mm
3 x 6 sq. mm
Design, fabrication, assembling, wiring, supply, installation, testing and commissioning of control panels, fabricated out of 14 gauge CRCA sheet steel in cubicle compartmentised, free standing floor mounted, with a base channel of 100x 50 x 6 mm MS channel dust and vermin proof with reinforcement of suitable size angle iron channel sections and or flats wherever necessary 3mm thick cable gland plates shall be provided on top as well as at the bottom of the panels. Panels shall be treated with seven tank process before painting as per specifications and a final approved shade of powder coated paint 2 Nos earthing terminals shall be provided for all distribution panels. Panels shall be suitable for 415 V 3 phase 4 wire, 50 HZ supply system, Lifting hooks shall also be provided in case of large panels. Approval shall be taken for each panel in the form of shop drawings before fabrication. Galvanized hard wares with Zinc passivation shall be used in fabrication of panels.
SUB-HEAD: VII: REMOVING WORK EXISTING EXTERNAL SERVICES :-
Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil outside IIM A Campus at locations approved by local authority as per their rule. ( Note : Water Supply line to be removed properly and reuse this piping for new installation piping work. ) Removing of Existing drainage & water supply line )
All kinds of soil.
Providing and laying Double Flanged (Screwed/ Welded) Centrifugally (Spun) Ductile Iron Pipes of Class K - 9 conforming to IS : 8329 :
100 mm dia Ductile Iron Double Flanged
ELECTRICAL WORKS
SECTION - 1 SUBSTATION EQUIPMENT AND AUXILLARY SUPPLY & Labour charges for installation, testing and commissioning of 11 KV panel indoor drawout type VCB cubical switchboards with complete internal wiring. The rate shall include the following activities. SCOPE - SUPPLY AS PER ATTACH SPECIFICATION +GST+TRANSPORTATION +INSURANCE & AS PER SPEICIFICIATION Installation Scope - i) Unloading of panel ,Shifting of panel to the room from site stores/out side if required. ii) Opening of packing. iii)Installation of 11 KV SF6/VCB cubical switchboard on the foundation, supply & grouting of the foundation bolts including supply of foundation bolts, nuts, washers, making pockets in the floor etc. at the location shown at site/in the drawing. iv) Assembling of all the panels, connections of busbars, wiring etc. as per manufactures drawing.
SUPPLY & Installation of Indoor Drawout type - BREAKER - 11 KV VCB + ES panel (total nos of panels-3), connection of bus bar , Checking of control wiring, Setting of relay, Testing with co-ordination with H.T.Panel vendor be fore commissioning ( 2-I/C -1- O/G )
SUPPLY & INSTALLATION- OF STEP DOWN POWER / DISTRIBUTION TRANSFORMER. (DRY TYPE) SCOPE - SUPPLY AS PER ATTACH SPECIFICATION +GST+TRANSPORTATION +INSURANCE & AS PER SPEICIFICIATION SCOPE OF Labour charges for installation, testing and commissioning of following step down Distribution / power transformer as shown in the drawing. The rate shall includes the following activity and work. -Unloading & shifting to store of transformer / shifting from store to site ( If required ) i) Providing transformer on the otta/foundation with all tools, equipments and accessories. ii) Fixing of all transformer accessories etc. as per supplier drawing. iii) Testing of transformer before commissioning. iv) Locking of transformer wheels on the channel. v)- oil testing ( if Oil Type ) vi) The installation,Testing & Commissioning work shall be completed as per the technical Requirement : All hardware like Nuts, Bolts, Washers, Spring washers etc. require in the installation shall be of Hot deep galvanized. STEP DOWN DISTRIBUTION TRANSFORMER. (On Load tap changer)
SUPPLY & INSTALLATION OF 11/0.411 KV 750 KVA STEP DOWN DISTRIBUTION TRANSFORMER.WITH OLTC & RTCC PANEL ( DRY TYPE)
SUPPLY & INSTALLATION OF 11 HT (E) END TERMINATION
Supply, Termination , testing and commissioning of 11KV (E)H.T. end heat shrink type joints - outdoor type with Raychem/ 3 M make kits for 3 c x 300 sqmm AL XLPE SCOPE Includes -magger testing of cable / supply of termination kit with AL lug . Nut blots -washer / tools & teckals require for jointing
Supply, Termination , testing and commissioning of 11KV (E)H.T. end straight joints - outdoor type with Raychem/ 3 M make kits for 3 c x 185 sqmm AL XLPE SCOPE Includes -magger testing of cable / supply of termination kit with AL lug . Nut blots -washer / tools & teckals require for jointing (Rate Only)
Supply, Termination , testing and commissioning of 11KV (E)H.T. end cold shrink type joints - indoor type with Raychem/ 3 M make kits for 3 c x 185 sqmm AL XLPE SCOPE Includes -magger testing of cable / supply of termination kit with AL lug . Nut blots -washer / tools & teckals require for jointing
SUPPLY & INSTALLATION OF SAFTY EQUIPMENT
Supply & Fixing of ISI marked 6 kg Co2 type portable fire extinguisher with necessary clamps, supports and trolley in Panel room.
Supply and fixing of first aid box.
Supply & Fixing of 3 nos of fire buckets with floor / wall mounting stand and first filling of sand
Supply and fixing of 1 x 20 W FL T/L self contained emergency light with dry type maintenance free battery. (Rate Only)
Supply and fixing of 11KV / 1.1 KV grade 2mm(As Per IS-15653 2006) thick 1000 mm wide polymer silicon insulating mat
Hand gloves (11 KV grade)
Shock treatment chart with wooden frame and glass cover. (LOCAL & ENGLISH)
Modular type fire extinguisher ( Clean Agent material) with Sprinkar valve- 5 KG - which operate at 68/ 79 Dec temp with necessary fixing clamps,- for UPS room / BMS ROOM/ Electrical panel room
SECTION - 2 ELECTRICAL PANELS SUPPLY & INSTALLATION SCOPE - SUPPLY AND INSTALLATION OF L.T. PANELS AS PER ATTAH SPECIFICATION INCLUDING -GST/ TRANSPORTATION +INSURANCE + Unloading at site, shifting to final location, assembling, levelling, grouting, erecting, testing and commissioning of following panels as per drawings. Any sort of fabrication work required for erection of panel at site shall be done by the contractor. The contractor shall also check for all the loose joints and continuity of the panel. Any physical or technical defects envisaged by the contractor shall be brought to consultants and clients knowledge. All floor mounted panels shall be with 150mm height stand as per site condition. Refer SLD for quoting
MAIN LT PANEL
350KVAR APFCR PANEL
UPS INPUT PANEL
UPS OUTPUT PANEL
LIFT PANEL
PLUMBING PANEL
FLOOR PANEL-1 (GROUND to 5t& 7th 7th FLOORS - NON COMPARTMENTALIZE)
HVAC ODU PANEL-1 (TERRACE FLOOR)
FLOOR PANEL-2 (SIXTH FLOOR - NON COMPARTMENTALIZE)
HVAC ODU PANEL-2 (TERRACE FLOOR)
HVAC ODU PANEL-3 (TERRACE FLOOR)
UPS POWER PANEL (SIXTH FLOOR - NON COMPARTMENTALIZE)
SUPPLY & INSTALLATION OF FOLLOWING RATING BUS TRUNKING The rate shall include the following activities. SCOPE - SUPPLY AS PER ATTACH SPECIFICATION + GST + TRANSPORTATION +INSURANCE SPEICIFICIATION - IEC-61439 / 35 KA /600-1000 VOLT IP 55 1.6 MM G.I. CRCA SHEET POWEDER COATED INSTALLTION SCOPE - Unloading at site, shifting to final location, assembling, levelling, grouting, erecting, testing and commissioning of BBT as per drawings. Any sort of fabrication work required for erection of BBT at site shall be done by the contractor. The contractor shall also check for all the loose joints and continuity of the BBT. Any physical or technical defects envisaged by the contractor shall be brought to consultants and clients knowledge. DISTRIBUTION BUS RISER (BUS TRUNKING) - PANEL TO EVERY FLOOR Supplying, installing by suspension on ceiling/along the wall, testing and commissioning of following capacity Sandwich Type Rising Mains for use on 3 phase 4 wire 415 V, 50Hz A.C. supply with metal clad enclosure having IP-54 rating after fixing the tap off boxes and all accessories, made of 1.6mm thick steel sheet duly powder coated in convenient sections complete with 4 Nos. aluminium bus bars having current density of 130 A/ sq. cm at nominal current rating, necessary joints, elbow joints & expansion joints and bends, fire barrier at each floor, provision of tapping at every meter, adopter box and copper flexible for joints, continuous earthing with 2 Nos. aluminium strip of suitable size (one on each side) including, G.I. clamping brackets, suspenders, angle iron bracket, steel fasteners, connecting to earthing system etc. as required.support / rod use from modular type only - approved make - hitech pune / indiana / OBO
400 A, AL . Isc = 35 kA for 1 second
Tap off box for 400 amp with 63A MCB 4P 10 KA with METERING UNIT
Feed End unit with flange 400 A 4P ISOLATOR
630 A,AL . Isc = 50 kA for 1 second
Tap off box for 630 amp with 400 MCCB 4P 36 KA
Tap off box for 630 amp with 250 MCCB 4P 36 KA
Tap off box for 630 amp with 160 MCCB 4P 25 KA
Tap off box for 630 amp with 125 MCCB 4P 25 KA
Tap off box for 630 amp with 100 MCCB 4P 25 KA
Feed End unit with flange 630 A 4P ISOLATOR
SECTION - 3 CABLE TRAYS (HOT DIPPED GALVANIZED IRON CABLE TRAY) 40-60 micron Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. Support / rod use from modular type only as per approved make
100 mm width X 50 mm depth X 1.6 mm thickness
150 mm width X 50 mm depth X 1.6 mm thickness
225 mm width X 50 mm depth X 1.6 mm thickness (Rate Only)
300 mm width X 50 mm depth X 1.6 mm thickness
450 mm width X 50 mm depth X 2.0 mm thickness
600 mm width X 50 mm depth X 2.0 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray “bends” (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. Support / rod use from modular type only
100 mm width X 50 mm depth X 1.6 mm thickness
150 mm width X 50 mm depth X 1.6 mm thickness
225 mm width X 50 mm depth X 1.6 mm thickness (Rate Only)
300 mm width X 50 mm depth X 1.6 mm thickness
450 mm width X 50 mm depth X 2.0 mm thickness
600 mm width X 50 mm depth X 2.0 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray “Tee” (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. Support / rod use from modular type only
100 mm width X 50 mm depth X 1.6 mm thickness
150 mm width X 50 mm depth X 1.6 mm thickness
225 mm width X 50 mm depth X 1.6 mm thickness (Rate Only)
300 mm width X 50 mm depth X 1.6 mm thickness
450 mm width X 50 mm depth X 2.0 mm thickness
600 mm width X 50 mm depth X 2.0 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray “Cross member” (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.
100 mm width X 50 mm depth X 1.6 mm thickness
150 mm width X 50 mm depth X 1.6 mm thickness
225 mm width X 50 mm depth X 1.6 mm thickness (Rate Only)
300 mm width X 50 mm depth X 1.6 mm thickness
450 mm width X 50 mm depth X 2.0 mm thickness
600 mm width X 50 mm depth X 2.0 mm thickness
STEEL FABRICATION FOR CABLE & PANEL / BUS TRUNKING SUPPORT
Supply and erecting fabricated support works / stands etc complete fabricated as per details given from MS flat / angle / plates etc complete with 2 coats of red oxide and 2 coats of paint on the same along with mounting of supports with use of necessary hardwares complete.
HANGER SUPPORT USING FULL THREADED G.I RODS with Anchor Fastener size as per requirement (10mm/12mm with 100 mm /150 long ( Support length is not more than 1500 mm)
12 MM FULL THREADED ROD
10 MM FULL THREADED ROD
PRE FABRICATED SUPPORT - SLOTTED ANGLE / 'C' , WALL BREAKET -2-3 MM AS PER THE REQUIRMENT / other than not specified in item boq OR other service support required with cable tray
SUPPLY & INSTALLTION OF Mechanical Anchor Fastener (HILTY or fisher make) Installation of anchor fisher as per standard given by manufacture Job including supply of Anchor Fasnter / with all tool like - drill machine / & other material reuired (other than not specified in item boq )
10 mm x 100 mm
10 mm x 150 mm
12 mm x 100 mm
SECTION - 4 MCCB, MCB & DB's
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.
SITC of 125A FP MCCB, 36 kA with Thermo plastic enclosure complete.
SITC of 63 A TPN MCB , 10 kAwith Thermo plastic enclosure complete. For ODU.
SITC of 40A TPN 10KA with with Thermo plastic enclosure complete. For ODU.
Supplying and fixing following way, Single Pole and Neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required.
8 way, Double door
12 way, Double door
Supplying and fixing following way, Horizontal type Three Pole and Neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator)
4 way (4 + 12), Double door
6 way (4 + 18), Double door
8 way (4 + 24), Double door
Supplying and fixing of following ways surface/ recess mounting, Vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 80 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCCBs and incomer) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)
8 way (4 + 24), Double door (Rate Only)
12 way (4 + 36), Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single pole
Double pole (Rate Only)
Triple pole (Rate Only)
Triple pole and neutral
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
25 A RCCB
40 A RCCB
Supplying,installation,testing and commissioning of Astronomical time switch of following configuration to be mounted in feeder pillars / Lighting DBs for automatic switching On & OFF of street lights at sun set & sun rise or twilight(Auto ON, Auto OFF, Auto modes) with manual override facility with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site complete as required.
3 output (1output per phase) and suitable for three phase supply
SECTION - 5.00 H.T./L.T. XLPE CU/AL ARM. CABLES
Supply of following size of 1.1KV grade multicore Aluminium conductor XLPE insulated & PVC sheathed armoured power cable as per IS: 7098 (Part-1) 1988 complete as required.
240 sq mm x 3C 11 KV HT AL. XLPE (E) CABLE
185 sq mm x 3C 11 KV HT AL. XLPE (E) CABLE
Supply of following size of 1.1KV grade multicore Aluminium / copper conductor XLPE insulated & PVC sheathed armoured power cable as per IS: 7098 (Part-1) 1988 complete as required.
300 SQMM X 3.5C AL XLPE CABLE
185 SQMM X 3.5C AL XLPE CABLE
95 SQMM X 3.5C AL XLPE CABLE
25 SQMM X 4C AL XLPE CABLE
16 SQMM X 4C CU XLPE CABLE
10 SQMM X 4C CU XLPE CABLE
6 SQMM X 4C CU XLPE CABLE
4 SQMM X 4C CU XLPE CABLE
2.5 SQMM X 4C CU XLPE CABLE
4 SQMM X 3C CU XLPE CABLE
2.5 SQMM X 3C CU FRLS FLEXIBLE CABLE FOR FAÇADE/GARDEN LIGHTING
1.5 SQMM X 3C CU FRLS FLEXIBLE CABLE FOR FAÇADE/GARDEN LIGHTING COPPER FLEXIBLE XLPE CABLE 1100 VOLT
1C X 35 SQMM for UPS
1C X 16 SQMM for UPS
HT CABLE LAYING Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 kV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required.
Up to 120 sq. mm
Above 120 sq. mm and up to 400 sq. mm (240 sq mm x 3C 11 KV HT XLPE (E) CABLE)
MV CABLE LAYING: Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required.
Up to 35 sq. mm
Above 95 sq. mm and up to 185 sq. mm
Above 185 sq. mm and up to 400 sq. mm
Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc. as required.
Up to 35 sq. mm
Above 95 sq. mm and up to 185 sq. mm
Above 185 sq. mm and up to 400 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size in the existing RCC/ HUME/ METAL pipe as required.
Up to 35 sq. mm
Above 95 sq. mm and up to 185 sq. mm
Above 185 sq. mm and up to 400 sq. mm
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size on wall surface as required.
Up to 35 sq. mm (clamped with 1mm thick saddle)
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size on cable tray as required.
Up to 35 sq. mm (clamped with 1mm thick saddle)
Above 35 sq. mm and up to 95 sq. mm (clamped with 25x3mm MS flat clamp)
Above 95 sq. mm and up to 185 sq. mm (clamped with 25/ 40x3mm MS flat clamp)
Above 185 sq. mm and up to 400 sq. mm (clamped with 40x3mm MS flat clamp)
SECTION - 6 MV/HV CABLE JOINTING & END TERMINATION
MV CABLE JOINTING & END TERMINATION: Supplying and making end termination with double brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required.
300 SQMM X 3.5C AL XLPE CABLE
185 SQMM X 3.5C AL XLPE CABLE
95 SQMM X 3.5C AL XLPE CABLE
25 SQMM X 4C AL XLPE CABLE
16 SQMM X 4C CU XLPE CABLE
10 SQMM X 4C CU XLPE CABLE
6 SQMM X 4C CU XLPE CABLE
4 SQMM X 4C CU XLPE CABLE
2.5 SQMM X 4C CU XLPE CABLE
4 SQMM X 3C CU XLPE CABLE
2.5 SQMM X 3C CU FRLS FLEXIBLE CABLE FOR FAÇADE/GARDEN LIGHTING
1.5 SQMM X 3C CU FRLS FLEXIBLE CABLE FOR FAÇADE/GARDEN LIGHTING COPPER FLEXIBLE XLPE CABLE 1100 VOLT PVC GLAND
1C X 35 SQMM for UPS
1C X 16 SQMM for UPS
SECTION - 7 POINT WIRING : - LIGHTING & POWER
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Group A
Wiring for group controlled (looped) light point / fan point / exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.
Group A
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
3 x 1.5 sq. mm
6 x 1.5 sq. mm
9 x 1.5 sq. mm
3 x 2.5 sq. mm
4 x 2.5 sq. mm
6 x 2.5 sq. mm
3 x 4 sq. mm
4 x 4 sq. mm
4 x 6 sq. mm
Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required.
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. FOR CIRCUIT MAINS WIRING
40 mm (Rate Only)
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
TV antenna socket outlet
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required.
1 or 2 Module (75 mmX75 mm) FOR TV
3 Module (100 mmX75 mm)
6 Module (200 mmX75 mm)
8 Module (125mmX125mm)
12 Module (200mmX150mm) (Rate Only)
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. WIRING SEPARATE ITEM ( 7.3)
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. WIRING SEPARATE ITEM ( 7.3)
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
Supplying, Installation, testing and commissioning of wall bracket /ceiling fittings of all sizes and shapes containing LED fitting, complete with all accessories including connections etc. as required.
Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required.
SECTION -8.00 LIGHT FIXTURES & FANS :
Supply, Installation, testing & commissioning of standard light fittings and lighting accessories including lamp. The scope shall include, providing of all hardware such as nuts,anchor fasteners, bolts, screws, cleats, clamps, PVC insulated wires / cables from Junction box to lighting fixtures, ball and socket 'arrangement with J.B., suspension conduit pipe for drop for fluorescent fitting The cost of fabrication and installation of MS supports will be paid extra as per rates quoted elsewhere. All fixtures shall be with Electronic ballasts of APFC type. (All Light fixtures shall including High performance electronic driver, 4KV surge protection, aluminium housing with white PC finish - For External area Light fixtures - 3000K CRI; Public area Light Fixtures - 4000K CRI & For Office area Light Fixtures - 4000K/5700K/6500K CRI)
Surface mounted type 1 x 10W LED type fixture
Surface mounted type 1 x 20W LED type fixture
Surface mounted type 1 x 36W 2'x2' LED Decorative type fixture
Surface/Ceiling mounted type 1 x 15 W LED light fixture
10W LED Bulk Head fitting
Surface mounted type 1 x 10W LED type fixture
10W LED mirror light wall mounting
Circular Suspended type 1 x 32W LED type fixture (Rate Only)
Linear Suspended type 25W LED light fixture
Wall mount type 25W LED tube light fixture
Wall mount type 10W LED external grade light fixture (Rate Only)
1200 mm dia. Ceiling fan.
900 mm dia. Ceiling fan. (Rate Only)
450 mm dia. Sweep wall mount fan
35W Projector Façade Light RGBW
35 W LED decorative light fitting for path way light
Up Down wall Light fixture-5-9 W LED Type
Supply & Installation of 80 W LED Type flood light fitting with DRIVER & control gear box for facade area lighting (Rate Only)
Supply & Installation of 60 W LED Type Street light fitting with DRIVER & control gear box (Rate Only)
Supplying,installation,testing and commissioning of Passive Infrared(PIR) technology based occupancy sensor with day light dimming(lighting level shall be regulated as per availability of natural day light in an area along with occupancy detection.) having high performance, regulating programmable type, suitable for connected load up to 10 A, for mounting height up to 2.8 meter and for 5 meter diameter coverage area along with necessary fixing arrangements i/c programming at site etc. complete as required. (Rate Only)
External Lighting - Supply & Installation of Poles / Wall Bracket / Flood light pole / Decorative Poles - Civil work for Installation of Pole in scope of contractor
Supply & installation of Wall Bracket with FRP/ Thermo Plastic Junction Box for Flood light fitting ( detail as per attach sheet) (Rate Only)
Decorative Path way light poles (4 mtr height) - 100 mm dia G.I. pipe /with cap of size of as per light fitting requirement (as per attach sheet)circular and seamless in shape
SUPPLY & INSTALLATION OF STREET LIGHT POLE: Providing, erecting, testing, connecting and commissioning of M.S. tubular swagged type pole with junction box. The pole height shall be of 7.5 mtrs. ( 6 mtrs. above ground)with one/two/three/four arms. The pole shall be directly buried in the ground at a depth of 1.5 mtrs. below average ground level. The job includes excavation of earth, putting the pole in plumb, and concreting with 1:4:8 mixture of cement, grit and sand. The dimension of concrete base shall be of 750 x 750 x 1500 mm high. and bottom base shall be of 1000 x 1000 x 150 mm. thick. The job includes supply of all materials like cement, sand grit and the labours. The detail dimension of the pole is as below: Section detail: Bottom - 4.5 mtrs long - 139.2 mm dia - 4.5 mm thick. Middle - 1.5 mtr. long - 114.3 mm dia - 3.65 mm thick. Top - 1.5 mtrs. long - 88.9 mm dia - 3.25 mm thick. Over hang: 1.5 mtr. long with 80.0 mm. dia and 3.25 mm. thick. (Check With Light Fittings Before Starting Manufacturing) i) The base plate of the pole shall be of 300 x 300 x 6 mm thick M.S. plate having 4 nos stiffener. The portion of the pole, which is buried in the ground shall be applied with two coats of anticorrosive bituminous paint. The outer portion of pole above the ground shall be painted with two coats of red oxide and then two coats of epoxy paints. The job also include supply and fixing of 1" dia. G.I. pipe in the ground to take out the cable from ground to the junction box. The job includes the cost of supply & fixing of Thermoplastic or F.R.P. street light junction box WITH SP MCB/ 16 AMP Connector(CUDD4S of Elmex make or Eq.)3c x 2.5 sqmm flexible cable from J.B. to fitting as per the enclosed details. The box shall be fitted using clamps of 20x3 mm thick M.S. flats bend to the shape of the pole. ii) The rate also include the assembling, installation, testing and commissioning of 150/90/70/40 W LED Street light fixture, and required control gear box. The control gear shall be provided with control gear ignitor, capacitor, etc. The item further includes all the interconnecting flexible cables between junction box, fixture and control gear box etc. testing of fixture before and after box installation including control gear etc. As Per Attached Drawing Note: Rate should not include the cost of Lighting Fittings
SUPPLY AND INSTALLATION OF 7.5 MTR STREET LIGHT POLE (6 mtrs. Above ground) WITH DOUBLE ARM BRACKET (Rate Only)
SUPPLY AND INSTALLATION OF 7.5 MTR STREET LIGHT POLE ( 6 mtrs. Above ground) WITH ONE ARM BRACKET As Per Attached Drawing (Rate Only)
Supply of LED lamp type aviation light with mounting accessories of 3 mtr max height and control box having auto timer with day light sensor and flickering circuit meeting parameters of AAI with necessary whether proof housing for control gears & minimum 1 hour back up supply Note: Rate should not include the cost of Lighting Fittings
SECTION -9.00 EARTHING : Bore- 300mmmm, bottom 4" filling with compound paste- vertically placed electrode in center of pit(no use of hammer), make paste of compound of black soil (if available)- fill up in bore/pit, ensure no air gap in compound- use water to remove air gap. Also follow manufacture installation details to get resistance (less than 1 ohm)
Supply & making of maintenance free Earthing station with the use of 21/19MM CU ROD , 3M long- ,with 50kg- grounding material(back fill compound with moisture capture capacity and reuse soil) resistivity - scope includes supply of electrode/ back fill compound / labour charges for bore of 300- 3.5 mtrs depth/making earth chamber with 450 mm x 450 mm x CI / FRP cover Installation detail - making 3.5 m depth bore - 100 mm fill with chemical compound paste / put electrode in centre of bore / fill up balance space of bore with chemical compund / black cotton soil ( if available ) paste - careful for no air gap in paste , ALSO CHECK WITH ELECTRODE / COMPUND MANUFACTURE FOR INSTALLATION DETAIL TO ACHIVE LESS THEN 1 OHM
Supply & making of maintenance free Earthing station with the use of 50mm dia Hot Dip Galvanized pipe in Strip type (80-100 micron),3M long- ,with 50kg- grounding material(back fill compound with moisture capture capacity and reuse soil) resistivity - scope includes supply of electrode/ back fill compund / labour charges for bore of 300- 3.5 mtrs depth/making earth chamber with 450 mm x 450 mm x CI / FRP cover Installation detail - making 3.5 m depth bore - 100 mm fill with chemical compund paste / put electrode in centre of bore / fill up balance space of bore with chemical compund / black cotton soil ( if available ) paste - careful for no air gap in paste , ALSO CHECK WITH ELECTRODE / COMPUND MANUFACTURE FOR INSTALLATION DETAIL TO ACHIVE LESS THEN 1 OHM
Supply & making of maintenance free Earthing station with the use of 25 mm Dia Copper bonded Rod (250 micron) -scope scope includes supply of electrode/ back fill compund / labour charges for bore of 300- 3.5 mtrs depth/making earth chamber with 450 mm x 450 mm x CI / FRP cover Installation detail - making 3.5 m depth bore - 100 mm fill with chemical compund paste / put electrode in centre of bore / fill up balance space of bore with chemical compund / black cotton soil ( if available ) paste - careful for no air gap in paste , ALSO CHECK WITH ELECTRODE / COMPUND MANUFACTURE FOR INSTALLATION DETAIL TO ACHIVE LESS THEN 1 OHM for lighting protection
SUPPLY & FIXING OF EARTHING GRID BY COPPER (99.9 % PURE) / HOT DEEP GALVANIZED (80-100 Micron) STRIP
Supplying and laying 25 mm X 5 mm copper strip at 0.50 meter below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50 mm)
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 meter below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50 mm)
Providing and fixing 32 mm X 6 mm G.I. strip on surface or in recess for connections etc. as required.
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Providing and fixing 50 mm X 6 mm G.I. strip on surface or in recess for connections etc. as required.
SITC of 10.0 sq mm single core flexible copper wire of green colour
SITC of 6.0 sq mm single core flexible copper wire of green colour
SITC of 4.0 sq mm single core flexible copper wire of green colour
SITC of 2.5 sq mm single core flexible copper wire of green colour
Equipotential Bars
Equipotential bars - 300 x 50 x 6 mm GI.
Equipotential bars - 150 x 50 x 6 mm copper
Accessories for Lightning Protection
8 / 10 mm dia CU bonded conductor as down conductor in column
Re bar plate 150 x 150 x 10 mm SS 304 with clamp to connect with 10/8 mm copper bar in column
Connector for Cross connection for rod
Connection Clamp for earth Rod on flat conductor (copper)
8 / 10 mm dia Solid AL conductor for mash at terrace level
Air terminal 3000mm AL with Support stand (10 KG)
Down conductor clamp for 8/10 mm copper bonded rod
Roof conductor holder for 8/10 AL rod other than above any accessories required for Lighting protection any type of clamp should be including in rate
SECTION -10.0 COMPUTER/DATA NETWORKING
Supply, Installation testing and commissioning of GI floor raceway of 300 x 38 mm of 1.6 mm thickness- 3 Compartment including cutting of civil works if required.
Supply, Installation testing and commissioning of GI floor raceway of 225 x 38 mm of 1.6 mm thickness- 3 Compartment including cutting of civil works if required.
Supply, Installation testing and commissioning of GI floor raceway of 100 x 38 mm of 1.6 mm thickness- 1 Compartment including cutting of civil works if required.
SITC of 100 x 50 mm PVC raceway with partition to be fixed on wall with all necessary accessories like bends / couplers / end caps etc complete.
Supply, Installation testing and commissioning of GI floor raceway outlet junction box of 350 x 350 x 65-75 mm.
Supply, Installation testing and commissioning of GI floor raceway outlet junction box of 150 x 150 x 65-75 mm.
SECTION -10.0 COMPUTER/DATA NETWORKING
Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc. as required.
150 mm dia
300 mm dia
SITC of 38 mm PVC pipe of heavy gauge with bends / couplers etc complete with accessories to mount the same within shaft / suspend with help of threaded rod / slotted angle from ceiling etc complete.
-do as above but 50 mm dia.
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.
120 mm dia (OD-120 mm & ID-103 mm nominal) (Rate Only)
160 mm dia (OD-160 mm & ID-135 mm nominal) (Rate Only)
SITC of ISI marked 25 mm dia B-Class GI conduit with all necessary accessories, bends , couplers etc complete.
SITC of IP 65 category Thermo Plastic Material junction boxes with necessary loop in loop out connectors / busbars / internal wiring if required etc. complete. The boxes if required shall be mounted on 9" MS supports which shall be considered in cost. Rate considering terminal require up 35 sqmm cable - SIZE TO BE CHECK WITH VENDOR - NEAR SIZE TO BE CONSIDERING & MENTION IN OFFER
EXCAVATION & BACK FILLING OF TRANCHES FOR CABLE /PIPE LAYING
Excavation of cable trench of suitable size depending upon the Nos. of cables to be laid in average soil and refiling of cable trench after laying of cable including watering and removing supply earth..( FOR HT.cable - 1200 mm depth & for L.T. able 1000 mm depth)
Supplying & filling of clean river sand.200 mm
Supplying & installation of cable route markers (H.T /L.T)
SECTION -12.0 DG SET & UPS WORKS & SOLAR PANEL WORKS
Supply & installation of D.G. set of 750 KVA with acoustic enclosure, fuel piping, standard fuel tank, D.G. control panel, residential silencer,exhaust piping complete. Installation of DG SET. Scope of work. 1. Unloading 2. Shifting and final location. 3. Fixing/connecting loose points, testing and commissioning in the presence of DG set Engineer.
A.M.C. Charges for 5 Years of above D.G. Set rating
Supply & Installation of power & control AMF panel for 750 KVA as per L.T. panel specification & SLD
SITC of exhaust piping for above D.G. sets with necessary cladding / clamping on building external wall with necessary supports / insulation and foiling / civil and other associated fabrication works complete. Horizontal run for pipes from D.G. set to building face - app. 6 mtrs distance shall be done with supports at both ends. -
SUPPLY installation, testing and commissioning of 50 KVA UPS, 3 phase input and 3 phase output online with 30mins battery backup- For emergency lighting /For surveillance / computer (PARALLEL OPRATION FOR GROUND TO 5th FLOOR)
A.M.C. Charges for 5 Years of above UPS rating
SUPPLY installation, testing and commissioning of 20 KVA UPS, 3 phase input and 3 phase output online with 30mins battery backup- For emergency lighting /For surveillance / computer (PARALLEL OPRATION FOR 6th & 7th FLOOR)
A.M.C. Charges for 5 Years of above UPS rating
Supply, Installation, Testing & Commissioning of 25KW Grid Tied Solar Power Plant with Solar Panels, Solar Inverter, Module Mounting Structure and BOS.
A.M.C. Charges for 5 Years of above SOLAR rating
FIRE FIGHTING WORKS
PUMP HOUSE EQUIPMENT Supply, Installation, Testing and commissioning of Electrical Motor Driven Fire Pump Set (Factory Fitted) suitable for automatic operation consisting of the following as per the specifications of fire fighting requirements given in TAC OR LOCAL AUTHORITY APPROVAL
Supply, erection, testing & commissioning of Horizontal end suction fire pumps having cast iron casing, cast iron diffusers, bronze impellers and dynamically balanced, AISI 304/410 stainless steel shaft running in double ball bearings. Each pump shall be fitted with gland packing and shall be directly coupled on an MS fabricated common base plate to a AC 3 phase, 2900 RPM TEFC EFF - 2 motor with adequate number of Anti Vibration Mounting Pads, "DUNLOP" or equivalent make as per manufacturer's recommendations . Each pump shall be capable of delivering a capacity of 2850 LPM at a total head of 80 mtrs. ( For Hydrant System). The Pump set shall be capable to work on Auto Mode and Manual Mode.
Supply, erection, testing & commissioning of Horizontal end suction fire pumps having cast iron casing, cast iron diffusers, bronze impellers and dynamically balanced, AISI 304/410 stainless steel shaft running in double ball bearings. Each pump shall be fitted with gland packing and shall be directly coupled on an MS fabricated common base plate to a AC 3 phase, 2900 RPM TEFC EFF - 2 motor with adequate number of Anti Vibration Mounting Pads, "DUNLOP" or equivalent make as per manufacturer's recommendations . Each pump shall be capable of delivering a capacity of 2850 LPM at a total head of 80 mtrs. ( For Sprinkler System). The Pump set shall be capable to work on Auto Mode and Manual Mode.
Supply, erection, testing & commissioning of vertical multistage Jockey Pumps having cast iron casing, cast iron diffusers, bronze impellers and dynamically balanced, AISI 304/ 410 stainless steel shaft and pump base. Each pump shall be fitted with mechanical seals and shall be directly coupled on motor stool with AC 3 phase, 2900 RPM TEFC EFF - 2 motor. Each pump shall be capable of delivering a capacity of 180 LPM at 80 mtrs. head. (Common For Hydrant & Sprinkler System).The Pump set shall be capable to work on Auto Mode and Manual Mode.
Supply, erection, testing & commissioning of Horizontal end suction fire pumps having cast iron casing, cast iron diffusers, bronze impellers and dynamically balanced, AISI 304/410 stainless steel shaft running in double ball bearings. Each pump shall be fitted with gland packing and shall be directly coupled on an MS fabricated common base plate to a Diesel Engine, 1800 RPM with adequate number of Anti Vibration Mounting Pads, "DUNLOP" or equivalent make as per manufacturer's recommendations, along with Diesel Tank made from 3 mm The M.S. Sheet of 200 Ltrs . Diesel Tank shall be mounted on M.S.Fabricated stand to supply the Fuel to Engine on gravity as recommended by Engine Manufacturer. Piping of Fuel supply to Engine from the Diesel Storage tank within the Pump Room shall be included. Each pump shall be capable of delivering a capacity of 2850 LPM at a total head of 80 mtrs. (Common for Hydrant & Sprinkler System). The pump set shall supply along with Batteries of 12V / 24 V, with Battery Cable and required accessories. Battery should be mounted on Stand. The Pump set shall be capable to work on Auto Mode and Manual Mode.
CONTROL PANEL FOR FIRE PUMPS
Supply, erection, testing & commissioning of Pressure switches of diaphragm operated SPDT type IP66 suitable range (20 kg/cm² to 5 kg/cm²) for pump sets with Ball valves, Fittings like unions / collars / reducers etc.
Supply, erection, testing & commissioning of Pressure gauges of suitable range (0 kg/cm² to 21 kg/cm²) for pump sets with Ball valves, siphon, Fittings like unions / collars / reducers etc.
CABLE TRAY Supply and Erecting of LADDER type Hot dip G.I. cable tray of 14G of specific dimensions. The cable tray shall be hung from ceiling / fixed to wall with necessary ceiling suspenders, together with tees, bends etc including cost for supports as described. The tray shall be earthed. Min size (not a limitation) of supports shall be as follows (a).-up to 300mm tray 2nos. 8mm full threaded GI. rod with 2nos.anchor fastener and "C" channel support at 500mm distance (b) 450 to 600mm tray 2nos.10mm full treaded G.I. rod with 2nos. anchor fastener and "C" channel support at 500mm distance (c) 750 / 1000 mm cable tray with fabrication of 25 x 6 or 50 x 3 mm angle frame with min. 4 no's anchor fastener at 500 mm distance.
300 X 50 mm Cable Tray
150X 50 mm Cable Tray
G.I. Earthing strips of the following Sizes shall be run on floor / ceiling / walls, from the equipment to the nearest Earth pit with necessary accessories as required. ( Earth pit shall be executed by other agencies).
25mm x 5 mm thick,
250mm nominal dia
200mm nominal dia
150mm nominal dia
100mm nominal dia
80mm nominal dia
50mm nominal dia
25mm nominal dia
Supplying, Installing, testing and commissioning CI butterfly valves as per BS 5155 ( PN 16) slim seal with required flanges, nuts, bolts etc. complete.
250 mm nominal dia (Gear operated)
200mm nominal dia (Gear operated)
150mm nominal dia (Lever operated)
100mm nominal dia (Lever operated)
80mm nominal dia (Lever operated)
50mm nominal dia (Lever operated)
Supplying, installing, testing and commissioning of Gun metal chrome finished Ball valves with fittings of screwed end type. (PN 16)
15mm dia.
25 mm dia
Supplying, installing and commissioning C.I.flanged "Y" type Strainer with SS mesh, suitable flanges, nuts, bolts, gaskets etc. complete.
250 mm Dia
Supplying, installing, testing and commissioning of C.I. Non-return valves of PN16 with required flanges, nuts, bolts and gaskets etc. complete.
200 mm nominal dia
150 mm nominal dia
80 mm nominal dia
1100 V GRADE POWER / CONTROL CABLES Supplying, laying, testing & commissioning of XLPE,PVC outer sheath, steel armoured, copper conductor, 1100V grade power cables including termination with lugs and brass cable glands etc. The cables shall be laid in tray. as required. The size of the cables shall as mentioned below,
3.5C x 25 sq.mm Copper for main pumps
3 C x 6.0 Sqm. Copper for Jockey pump
2 C x 1.5 Sqmm copper armoured for Instrumentation
9 C x 2.5 Sqmm copper armoured for Instrumentation of Diesel Engine
Exhaust pipe for Diesel engine of 150 mm dia M.S. Medium grade with mineral wool insulation with aluminium sheet. 150mm dia M.S. Medium grade shall be laid above ground with structural steel supports.
HYDRANT SYSTEM
150mm nominal dia
100mm nominal dia
80mm nominal dia
50mm nominal dia
25mm nominal dia
Supplying, installing, testing and commissioning of buried M.S. Pipes confirming to IS 1239 Pt - I Heavy grade with suitable type of supports, fittings such as reducers,tees, elbows, flanges. Including cutting, Welding as per drawings. The rate quoted should be included with anti corrosive treatment with 4 mm thick polymer corrosion resistant tape, primer as per IS 10221, overlap shall be 15mm minimum.
150mm nominal dia
100mm nominal dia
80mm nominal dia
Providing, laying, jointing & Testing of Hume pipe class - NP3
300 mm dia
Supplying, Installing, testing and commissioning CI butterfly valves as per BS 5155 ( PN 16) slim seal standard lever operated / gear operated type with required flanges, nuts, bolts etc. complete.
150mm nominal dia (Lever operated)
100mm nominal dia (Lever operated) (Rate Only)
50mm nominal dia (Lever operated)
Supplying, installing, testing and commissioning of C.I. Non-return valves as per IS:5312( PN 16) swing check type with required flanges, nuts, bolts and gaskets etc. complete.
150 mm nominal dia
Supplying, Installing, testing and commissioning CI butterfly valves as per BS 5155 ( PN 16) slim seal standard lever operated / gear operated type with required flanges, nuts, bolts etc. complete.
Single headed hydrant valve as per IS 5290, made of SS with 63 mm dia instantaneous out & 80 mm dia fanged inlet inlet, blank cap , chain and hand wheel etc complete.
Supplying, installing, testing and commissioning of S.S. orifice plate of 6 mm thk. for single hydrant
Supply, erection, testing & commissioning of Stainless Steel 63 mm dia short size Branch pipe with 20mm dia nozzles
Supply, erection, testing & commissioning of 63 mm x 15 Mtrs long RRL hose pipe complete with pair of SS couplings.
Supply, erection, testing & commissioning of Hose reel drum with powder coated finish, fitted with heavy duty MS brackets, of swinging type with 25 mm dia Rubber braided hose of 36.5M. length with Gate valve (on upstream) and SS shut off nozzle, complete.
Supply, erection, testing & commissioning of Gun metal Air Purge Valve with ball valve & other accessories
25 mm dia BSP male threaded
Supply and installation of Fire Hook. Hook Head shall be made of Forged Steel. Handle Length shall be of Minimum 3 Mtrs.
FIRE BRIGADE INLET
Supply, installation & testing Providing and fixing gun metal fire brigade connection 4 way consisting of 4 nos 63 mm dia instantaneous type male coupling with built-in check valves and 150 mm dia. flanged outlet complete with bolts, nuts and rubber insertions as required as per IS:904-1983.Qouted rate shall be included with C.I. Butterfly valve, C.I. Non-return valve,M.S. cabinet of suitable size and mounting supports etc. complete.
Supply, erection, testing & commissioning of 100 dia. Two way fire brigade connection with 63 MM dia gun metal instantaneous inlet. (For fire tank filling)
SPRINKLER SYSTEM
150 mm dia
100 mm dia (Rate Only)
80 mm dia
65 mm dia
50 mm dia
40 mm dia
32 mm dia
25 mm dia
Supplying, installing, testing and commissioning of buried M.S. Pipes confirming to IS 1239 Pt - I Heavy grade with suitable type of supports, fittings such as reducers,tees, elbows, flanges. Including cutting, Welding as per drawings. The rate quoted should be included with anti corrosive treatment with 4 mm thick polymer corrosion resistant tape, primer as per IS 10221, overlap shall be 15mm minimum.
150 mm dia
Supplying, installing, testing and commissioning conventional quartzoid bulb type Sprinkler with screwed end connection. Sprinklers shall be UL Listed / FM approved with Chrome finish.
15 mm dia (Standard Horizontal side wall) ,K-5.6 (Rate Only)
Supply and installation of bourdon type Pressure Gauges of suitable range( 0 to 21 Kg/ cm2) with Ball valves, siphon, Fittings like unions / collars / reducers etc.
Supplying, installing, testing and commissioning Flow Switch on sprinkler distribution header on each floor with necessary Junction Box and shall be connected to fire alarm panel through cable. Cable shall be measured separately. Flow switch shall be "UL" Listed and FM Global approved.
150 mm dia (Rate Only)
100 mm dia (Rate Only)
80 mm dia
Supplying, installing, testing and commissioning conventional quartzoid bulb type Sprinkler with screwed end connection. Sprinklers shall be UL Listed / FM approved with Chrome finish.
15 mm dia - Rating 57°C ( Pendent Type ) K-5.6
15 mm dia (Standard Horizontal side wall) ,K-5.6 (Rate Only)
Gun metal Air Purge Valve with ball valve & other accessories - 25 mm dia BSP male threaded
Supplying, installing, testing and commissioning of 25mm dia Inspection and Testing assembly with GM sight glass, GM isolation, by pass valves and connected to drain line complete ( excluding the cost of drain pipe)
Supplying, installing, testing and commissioning of S.S. orifice plate of 6 mm thick as per TAC design having projected identification tag duly marked with K -factor ( for Sprinkler Branches)
150 mm dia (Rate Only)
100 mm dia (Rate Only)
80 mm dia
Providing and fixing 450x450x150 mm wooden cabinet having full glass front door and locking arrangement with suitable shelves for keeping 10 spare sprinklers of pendent type, operating of 570C corresponding spanner of each type properly fixed in the cabinet painting with enamel paint of approved make and shade to the approval of engineer.
Supplying, Installing, testing and commissioning CI Butterfly valves as per BS 5155 ( PN 16) slim seal standard lever operated / gear operated type with required flanges, nuts, bolts etc. complete.
150 mm dia (Lever operated)
100 mm dia (Lever operated) (Rate Only)
80 mm dia (Lever operated)
25 mm Dia Ball valves (Rate Only)
Supplying, installing, testing and commissioning of hydraulically operated 150 mm dia Sprinkler Alarm Valve/ Installation Control Valve, with water motor gong bell, test trims, wet trim kit complete with stop valve, pressure gauges, drain valves, ball valves, check valves, strainers etc. confirming to latest IS Code complete. Alarm valve shall be UL Listed / FM approved.(shall be procured after due approval from EIC)
MISCELLANEOUS WORKS
Civil Work: Excavation, Backfilling of trenches for underground mains, S.V. Chamber, Inspection & Welding pits, etc. (in dry area):
Soft soil
Supplying, installing and commissioning Portable Fire extinguishers of following type & capacity.
Carbon-di- oxide type fire extinguisher of 4.5 kgs. Capacity, CO2 gas filled in brand new seamless cylinder with powder coated finish, made out of Manganese steel, with wheel type valve, discharge nozzle, bend & horn, wall mounting bracket etc. complete, confirming to IS: 15683.
ABC powder type fire extinguisher of 6 Kgs. Capacity, with initial filling in brand new cylinder with powder coated finish, fitted with Gun metal union, high pressure CO2 gas cartridge, discharge hose, floor trolley type / wall mounting bracket etc. complete, confirming to IS:15683.
Mechanical Foam type fire extinguisher 9Lts. Capacity, with initial filling in brand new cylinder with powder coated finish, fitted with Gun metal union, high pressure CO2 gas cartridge, hose and ABS type branch pipe and wall mounting bracket etc. complete, confirming to IS: 15683.
Fire buckets round bottom type enamel painted, white inside & Red out side and Letter "FIRE" in black out side and handle with mounting bracket.
SIGNAGES
Supply, erection of emergency exit signages (To be approved by EIC)
Emergency Exit (5"X12") (Rate Only)
Fire exit (5"X12") (Rate Only)
Co2 fire extinguishers (8"X16")
ABC fire extinguishers (8'X16")
Mechanical foams fire extinguishers (8"X16")
Fire Lift (4"X12")
In case of fire do not use lift, use staircases (8"X8")
Fire hose reel. (8"X8")
Manual call point. (4"X4")
Fire alarm panel. (4"X4")
Fire hydrant (4"X4")
Route Markers (10 mtrs rolls)
Letters and Nos. (8"X3")
PASSIVE COMPONENTS Supply, erection, testing of Passive Fire Protection System ( 2 Hours Fire Rated )
Cement System
Acrylic intumescent sealants (300 ml cartridge)
Bulkhead Sealer System
Pillows
Pillow Small -100 x 250 x 30mm
Medium- 200 x 250 x 40mm
Large – 300 x 250 x 40 mm
Providing necessary design calculation, shop drawings, as built drawing and obtaining clearance from statutory agencies etc.,
Pump Trigger System
3 Core x 1.5 Sq.mm Flexible Wire with PVC Conduit
ON / OFF Switch
HVAC Supply of Variable Refrigerant System Vertical Floor Standing AHU Supply of Vertical Floor Standing Double Skin Air Handling Units with 43mm thk. PUF insulated Panels with Aluminium anodised construction and thermal break profile with FANS adequate sized multi-row DX coil of suitable TR mention for cooling application with EC fans, Inbuilt & speed Control. with Extended drain pan of 1.2mm thick S.S.304 with 19mm thick rubber form Insulation As Per Specification & of Following Capacities With 20G G.I.Plain Inner & 24G G.I. outer pre-coated with Opposed blade Airofoil design low leakage Aluminium anodized, 1.2mm thick S.S.304 with 19mm thick rubber form Insulation.The unit shall have the provision to be connected via BMS for both control and monitoring purposes, additional items required may be specified.(Kindly consider 10micron return air filter in the AHU and also consider supply air plenum on the top of the AHU) Automatic ELECTRICAL CONTROL Panel / starter Panel with following details:A Suitable rating incoming MCCB/MCB, VFD of Danfoss FC-102 or equivalent make of (380-480 volt) 415 V with communication port for communication & BMS. Phase indicating lights & control MCBs ( RYB) Push buttons for manual start/stop of motor. Indicating light for starter on/off/trip. 220/24V control transformer for 2 way motorized valve/ Expansion valve. Interlocking terminals & wiring for fire damper, motorized dampers etc. as per control scheme. Necessary cabling work from AHU starter panel to AHU with internal unit wiring and copper earthing of air handling unit motors from the panel shall be included.(up to AHU starter panel power to be provided by client /electrical vendor)
GROUND FLOOR
23.38 TR / 11745 CFM 50mm Static - CIRCUIT-1
18.50 TR / 8532 CFM 50mm Static - CIRCUIT-2
FIRST FLOOR
22.55 TR / 11326 CFM 50mm Static - CIRCUIT-3
16.34 TR / 8235 CFM 50mm Static - CIRCUIT-4
SECOND FLOOR
18.40 TR / 9281 CFM 50mm Static - CIRCUIT-5
17.58 TR / 8874 CFM 50mm Static - CIRCUIT-6
THIRD FLOOR
19.71 TR / 9936 CFM 50mm Static - CIRCUIT-7
17.84 TR / 8828 CFM 50mm Static - CIRCUIT-8
4TH FLOOR
14.08 TR / 7125 CFM 50mm Static - CIRCUIT-9
17.84 TR / 8877 CFM 50mm Static - CIRCUIT-10
5TH FLOOR
16.06 TR / 8170 CFM 50mm Static - CIRCUIT-11
17.84 TR / 8877 CFM 50mm Static - CIRCUIT-12
6TH FLOOR
17.37 TR / 9049 CFM 50mm Static - CIRCUIT-13
18.34 TR / 9423 CFM 50mm Static - CIRCUIT-14
7TH FLOOR
22.47 TR / 11943 CFM 50mm Static - CIRCUIT-15
22.65 TR / 12077 CFM 50mm Static - CIRCUIT-16
Top Discharge VRV / VRF Out-door units
Remote control
Corded remote controllers (Rate Only)
Cordless remote controllers (Rate Only)
All refrigerant Joints
Installation of Variable Refrigerant System Vertical Floor Standing AHU Installation, Testing & Commissioning of Vertical Floor Standing Double Skin Air Handling Units with 43mm thk. PUF insulated Panels with Aluminium anodised construction and thermal break profile with FANS adequate sized multi-row DX coil of suitable TR mention for cooling application with EC fans, Inbuilt & speed Control. with Extended drain pan of 1.2mm thick S.S.304 with 19mm thick rubber form Insulation As Per Specification & of Following Capacities With 20G G.I.Plain Inner & 24G G.I. outer pre-coated with Opposed blade Airofoil design low leakage Aluminium anodized, 1.2mm thick S.S.304 with 19mm thick rubber form Insulation.The unit shall have the provision to be connected via BMS for both control and monitoring purposes, additional items required may be specified.(Kindly consider 10micron return air filter in the AHU and also consider supply air plenum on the top of the AHU) (Note:- All necessary cabeling work from AHU starter panel to AHU with internal wiring. Up to AHU starter panel power to be provided by client / electrical vendor.) Automatic ELECTRICAL CONTROL Panel / starter Panel with following details: Suitable rating incoming MCCB/MCB, VFD of Danfoss FC-102 or equivalent make of (380-480 volt) 415 V with communication port for communication & BMS. Digital ammeter, CTs & control MCBs. Phase indicating lights & control MCBs ( RYB) Push buttons for manual start/stop of motor. Indicating light for starter on/off/trip. 220/24V control transformer for 2 way motorized valve/ Expansion valve. Interlocking terminals & wiring for fire damper, motorized dampers etc. as per control scheme. Necessary cabling work from AHU starter panel to AHU with internal unit wiring and copper earthing of air handling unit motors from the panel shall be included.(up to AHU starter panel power to be provided by client /electrical vendor)
GROUND FLOOR
23.38 TR / 11745 CFM 50mm Static - CIRCUIT-1
18.50 TR / 8532 CFM 50mm Static - CIRCUIT-2
FIRST FLOOR
22.55 TR / 11326 CFM 50mm Static - CIRCUIT-3
16.34 TR / 8235 CFM 50mm Static - CIRCUIT-4
SECOND FLOOR
18.40 TR / 9281 CFM 50mm Static - CIRCUIT-5
17.58 TR / 8874 CFM 50mm Static - CIRCUIT-6
THIRD FLOOR
19.71 TR / 9936 CFM 50mm Static - CIRCUIT-7
17.84 TR / 8828 CFM 50mm Static - CIRCUIT-8
4TH FLOOR
14.08 TR / 7125 CFM 50mm Static - CIRCUIT-9
17.84 TR / 8877 CFM 50mm Static - CIRCUIT-10
5TH FLOOR
16.06 TR / 8170 CFM 50mm Static - CIRCUIT-11
17.84 TR / 8877 CFM 50mm Static - CIRCUIT-12
6TH FLOOR
17.37 TR / 9049 CFM 50mm Static - CIRCUIT-13
18.34 TR / 9423 CFM 50mm Static - CIRCUIT-14
7TH FLOOR
22.47 TR / 11943 CFM 50mm Static - CIRCUIT-15
22.65 TR / 12077 CFM 50mm Static - CIRCUIT-16
Top Discharge VRV / VRF Out-door units
Remote control
Corded remote controllers (Rate Only)
Cordless remote controllers (Rate Only)
All refrigerant Joints
Supply & Installation of the following components of VRV/ VRF system:
All refrigerant piping between indoor & outdoor units of neatly brazed & should pass thru in sleeves provide in columns / beams. At terrace level & Inside the air-conditioning area refrigerant piping and cabling running should be on the perforated heavy duty cable tray. Refrigerant pipes should be insulated with 19mm Thick (Closed Cell Elastomeric/Cross Linked Closed Cell Polyethylene) Tube Insulation with painted Starbond - 30-36 fire retardant high grade flexible adhesive and sealant as per specifications.
Power & Control cables between indoor and outdoor unit laid in PVC pipe and duly epoxy coated Black painted clamped .
M.S.Structure for installing VRV outdoor units duly epoxy coated.
PVC Drain piping for the units with 6mm Thick Closed Cell Elastomeric Nitrile Tube Insulation and duly epoxy coated Black painted clamped .
Testing & Commissioning charges along with topping-up of refrigerant
EEV KITS for Ahu's connected VRV out door units (EEV Kit As per Mentioned AHU TR)
EEV KIT - 30 HP
EEV KIT - 24 HP
EEV KIT - 28 HP
EEV KIT - 18 HP
EEV KIT - 20 HP
EEV KIT - 22 HP
EEV KIT - 26 HP
AIR DISTRTIBUTION SYSTEM Supply, Installation, testing, commissioning and balancing of Pressure independent rectangular VAV (Variable Air Volume units) with integral sound attenuator made of 22G GI sheet casing length 900mm consisting of 25mm thick 48Kg/cubic meter density fibre glass wool covered with tissue paper, Elliptical volume control damper, calibrated differential pressure sensor at inlet complete with open Bacnet system Belimo controller and Thermostat. (All VAV will be factory calibrated) (Note:- Please read latest CPWD Specification for the same)
GROUND FLOOR
1ST FLOOR
2ND FLOOR
3RD FLOOR
4TH FLOOR
5TH FLOOR
6TH FLOOR
7TH FLOOR
DUCTING & LOWSIDE WORK AIR DISTRTIBUTION SYSTEM
Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gasket,elbows,splitter,hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.
Thickness 0.63 mm sheet
Thickness 0.80 mm sheet
Thickness 1.00 mm sheet
Supply, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular/round ducting complete with neoprene rubber gasket,elbows,splitter,hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.
Thickness 0.63 mm sheet
Thickness 0.80 mm sheet (Rate Only)
Thickness 1.00 mm sheet (Rate Only)
Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal Elliptical ducting complete with neoprene rubber gasket,elbows,splitter,hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.
Thickness 0.63 mm sheet (Rate Only)
Thickness 0.80 mm sheet (Rate Only)
Thickness 1.00 mm sheet (Rate Only)
Thickness 1.25 mm sheet (Rate Only)
Supply, installation, balancing and commissioning of fabricated at site GSS sheet metal Elliptical ducting complete with neoprene rubber gasket,elbows,splitter,hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.
Thickness 0.63 mm sheet (Rate Only)
Thickness 0.80 mm sheet (Rate Only)
Thickness 1.00 mm sheet (Rate Only)
Thickness 1.25 mm sheet( Rate Only)
Supplying & fixing of powder coated extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications.
Supply, installation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc., as per specifications.
Canvass Connection
INSULATION WORK
Supply and fixing of acoustic lining of supply air duct and plenum with 25 mm thick resin bonded glass wool having density of 32 kg/m³, with 25 mm X 25 mm GI section of 1.25 mm thick, at 600 mm centre to centre covered with Reinforced Plastic tissue paper and 0.5 mm thick perforated aluminium sheet fixed to inside surface of ducts with cadmium plated nuts, bolts, stick pins, CPRX compound etc. complete as required and as per specifications.
Supplying, fixing acoustic lining on wall and ceiling of AHU rooms with 50mm thick, density 32 kg/cu.m resin bonded glass fibre insulation friction fixed in 610mm x 610 mm frame work made of 25X50X50X50X25 mm made out of 0.6mm thick GI sheet U shaped channel and covered with reinforced fibre glass tissue and finished with 0.80 mm perforated aluminium sheet etc. complete as required and as per specifications.
Supplying and fixing of following thickness duly laminated aluminium foil of mat finish closed cell Nitrile rubber (Class “O”) insulation on existing duct after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required.
19 mm thickness
Round Duct: (Thermal Insulation from Inside) Thermal insulation of Ducts with Class ‘O’ Plus(in accordance to UL 94(HBF, HF 1 & HF 2), 1996) Closed Cell Nitrile Rubber with antimicrobial and antifungal properties having thickness of 13 mm as per the technical specification.
13 mm thick
Supplying, Fixing, testing and commissioning of fire dampers in supply air duct/main branch and return air path as and where required of required sizes i/c control wiring, the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications. (FOR RETURN AIR AT CABINS)
Fire damper
Supply-Installation of AIR-COOLED INVERTER DX COOLING SYSTEM
Supply of INVERTER DX System HI-WALL UNIT 1.5 TR (IT Room @ 5th Floor)
Installation of INVERTER DX System HI-WALL UNIT 1.5 TR (IT Room @ 5th Floor)
All refrigerant piping between indoor & outdoor units of neatly brazed & should pass thru in sleeves provide in columns / beams.. Refrigerant pipes should be insulated with 13mm Thick Closed Cell Elastomeric Tube Insulation with painted Starbond - 30-36 fire retardant high grade flexible adhesive and sealant as per specifications.
Control cables between outdoor unit and Indoor Unit.
25mm Dia PVC Drain piping for the units with 6 mm thick nitrile rubber as per specifications.
Fabricated M. S. ANGLE structure included with Rubber pads fabricated duly epoxy painted (Black Paint) as per the requirement at site.
Testing & Commissioning charges along with topping-up of refrigerant as per specifications.
VENTILATION WORK
Ceiling Suspended Cabinet type fan ( PUMP ROOM VENTILATION ) Supply Installation testing and commissioning of Ceiling Suspended Cabinet Type Exhaust Unit With DIDW Backward curved centrifugal fan as Per Specification with Drive & Drive Package of Following Capacities. 5700 cfm with 30 mm static pressure (Basement level)
Cabinet type Inline Type Exhaust Unit for Toilet Ceiling Suspended Cabinet Type Circular Inline Exhaust fan Unit With DIDW Backward curved centrifugal fan as Per Specification with Drive & Drive Package of Following Capacities.
600 cfm with 25mm static pressure for Toilet at GF to 7th Floor
SITC OF Ceiling Suspended Cassette Type Toilet Exhaust Air Fan
100 CFM,20mm static- Toilet- 1st, 2nd, 3rd (Pantry), 4th, 6th, 7th Floor
200 CFM,20mm static- Electrical room-7th Floor
250 CFM,20mm static- Pantry-7th Floor
DUCTING & LOWSIDE WORK
AIR DISTRTIBUTION SYSTEM Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gasket,elbows,splitter,hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.
Thickness 0.63 mm sheet
Thickness 0.80 mm sheet
Thickness 1.00 mm sheet
Supply, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular/round ducting complete with neoprene rubber gasket,elbows,splitter,hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.
Thickness 0.63 mm sheet (Rate Only)
Thickness 0.80 mm sheet (Rate Only)
Thickness 1.00 mm sheet (Rate Only)
Supplying & fixing of powder coated extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications.(Rate Only)
Supplying & fixing of powder coated extruded aluminium Return Air Grills with louvers but without volume control dampers complete as required.
PVC Pipe for Toilet exhaust
100dia (Rate Only)
LIFTWELL PRESSURIZATION
7000CFM , 50 mm static
Supplying, Fixing,testing and commissioning of fire dampers in supply air duct/main branch and return air path as and where required of required sizes i/c control wiring,the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications. (AT Terrace Level & AHU Fresh Air duct each floor)
Fire damper
FIRE ALARM & PUBLIC ANNOUNSEMENT SYSTEMS
FIRE PANEL
Supply, installation, testing & commissioning of microprocessor based min 2 loop (Expandable up to 4 loops) Networkable Analogue addressable type fire alarm control panel with LCD display/Touch Panel capable of catering to the detectors and devices as listed under Sl. No. 2 of this BOQ. The panel should be equipped with sufficient numbers of loop with 10% spare capacity in each loop. Each loop shall have a minimum capacity of 125 addressable detectors & 125 addressable devices, QWERTY style alphanumeric keypad for the field programming and control of the fire alarm system, panel shall maintain a history file of the last 2000 events, along with provision for printer connectivity, 240 volts AC power supply, automatic battery charger, 24 volts sealed lead acid maintenance free batteries sufficient for 24 hours normal working and then be capable of operating the system for 30 minutes during an emergency conditions as required.(UL Listed / FM Approved)
Supply, installation, testing & commissioning of BACNET / Modbus Gateway for Integration with BMS Systems (UL Listed / FM Approved)
Supply, Installation, Testing and commissioning of Repeater panel with backlit LCD display/ LCD Touch screen functional keys like acknowledge, signal silence, system reset, lamp test etc. (UL Listed / FM Approved)
DETECTORS & INITIATING DEVICES
Supply, installation, testing & commissioning of Analog addressable multisensing detectors with mounting based LED, Address Switch , MS Box, complete as required and as per specification (UL Listed / FM Approved)
Supply, installation, testing & commissioning of intelligent addressable Heat detectors with indicating lamp mounting base, address switch complete as required as per specification (UL Listed / FM Approved)
Supply, installation, testing & commissioning of addressable Manual Call Station for initiation of fire alarm complete as required and as per specification (UL Listed / FM Approved)
Supply, installation, testing & commissioning of addressable Beam Detector / Conventional Beam Detector with Monitor module for initiation of fire alarm complete as required and as per specification (UL Listed / FM Approved)
MODULES & NOTIFICATION DEVICES
Supply, installation, testing & commissioning of fault isolator module for isolating shorted, desired and loose circuits between two successive fault isolators with automatic resetting arrangement complete as required and as per specification (UL Listed / FM Approved)
Supply, installation, testing & commissioning of addressable control modules for driving outputs like Hooters, magnetic door hold open mechanism, fire fighter jacks etc. complete as required and as per specification (UL Listed / FM Approved)
Supply, installation, testing & commissioning of relay modules for driving outputs like Fans, AHU etc. complete as required and as per specification (UL Listed / FM Approved)
Supply, installation, testing & commissioning of addressable monitor modules to give input to FAS like Sprinkler Flow switch complete as required and as per specification (UL Listed / FM Approved)
Supply, installation, testing & commissioning of response indicator complete as required and as per specification. (Rate Only)
Supply, installation, testing & commissioning of Hooter cum Strobe with minimum 75DB output and minimum 110 cd. The strobes shall be synchronized for better evacuation, complete as required and as per specification. (UL Listed / FM Approved)
DIGITAL VOICE EVACUATION SYSTEM WITH FIRE FIGHTER COMMUNICATION SYSTEM
Supply, installation, testing & commissioning of integrated 08 channel Digital Voice Evacuation and 2 way Communication Fire Fighters System capable to supervision of all the speaker circuits, with required suitable amplifiers ( Minimum 700 Watts ) and along with Rack & accessories required to complete the system. The equipment shall be of same make as panel as per specification. (UL Listed / FM Approved)
Supply, installation, testing & commissioning of Fire panel supervised 70db-84db Ceiling Mounted Speakers as specified & same make as of panel. (UL Listed / FM Approved) (Rate Only)
Supply, installation, testing & commissioning of Fire panel supervised 70db-84db Wall Mounted Speakers as specified & same make as of panel. (UL Listed / FM Approved)
Supply, installation, testing & commissioning of 2 way communication Fire Fighter's Telephone Jack. as per specification
Supply, installation, testing & commissioning of 2 way communication Fire Fighter's Handset
CABLES AND CONDUITS
SITC of flexible 2 C X 1.5 Sq mm FRLS Twisted Pair Tinted copper multistranded cable (Red Color) for Fire & (Blue/Black) for PA System. Complete with termination and testing as per requirement and as per specification.
SITC of Heavy Duty FRLS 25 mm PVC conduit for flexible 2 C X 1.5 Sq mm FRLS cable complete with all required accessories like junction boxes, bends, tees etc as required for the installation & termination for requirement and as per specification.
Supply, Installation, Testing & Commissioning of Hot Dipped Galvanized perforated type Cable tray consisting of continuous, rigid, cable management system, to allow continuous ventilation of cables and maximum dissipation of heat. Provide splices, supports, and other fittings necessary for a complete, continuously grounded system as per the Specs and sizes mentioned
50mm X 150 mm
50mm X 300 mm
50mm X 450 mm
ICT WORKS
A: PASSIVE FOR DATA
SITC of ETL Verified Category 6A U/UTP Cable, low smoke zero halogen (IEC 60332-3-22) white jacket, 4 pair count, 1000 ft (305 m) length.
SITC of 24 Port Loaded Straight Patch panels CAT6A (1U) U/UTP, Intelligent Upgradable.
SITC of Category 6A U/UTP Information Outlet, Data Nodes (at User Side)
SITC of Cat 6A Patch Cords, U/UTP, LSZH - 3 Feet, Data Nodes (at Rack Side)
SITC of Cat 6A Patch Cords, U/UTP, LSZH - 7 Feet, Data Nodes (at User Side)
Supply of CAT6A RJ45 I/O (in a Surface Mount Box) for Wireless AP's and Camera
Dual Face plate suitable to fix Cat 6A I/o.
Single Face plate suitable to fix Cat 6A I/o.
2 Core 1.5 Sq MM Speaker Cables.
18 AWG Microphone Cable
B: FIBER BACKBONE CABLE
SITC of 24F, Single mode (OS2), Bend Insensative Fiber, Outdoor Corrugated Steel tape armor, Gel free.
SITC of 12F, Singlemode (OS2), Bend Insensative Fiber, Outdoor Corrugated Steel tape armor, Gel free.
SITC of 48-fiber LC-Style, Singlemode, 19-inch ,2U Rack mount Patch Panel loaded with LC duplex SM OS2, 48F Pigtail Cartridge with Splice tray.
SITC of 12-fiber LC-Style, Singlemode, 19-inch ,1U Rack mount Patch Panel loaded with LC duplex SM OS2, 12F Pigtail Cartridge with Splice tray.
SITC of LC-LC Single Mode 9/125 micron Duplex, Bend Insensitive Fiber, LSZH Sheath, OS 2 Patch Cord, 3 Meter
C: RACEWAY, CABLE TRAY AND CONDUIT IN FLOOR/ SCREED RACEWAY Supply & Fixing of factory fabricated pre-galvanised sheet steel raceway in 16G thickness for bottom & sides and 14G thick top cover as called for including necessary civil work such as chase cutting in screed, fixing/ jamming the raceway, aligning & levelling and finishing with sand cement plaster & chicken wire mesh. Raceways shall be complete with junction boxes of required size & required quantity to be included in the cost of the raceways:
100mm x 38mm (14G top cover)
150mm x 38mm (14G top cover)
225mm x 38mm (14G top cover)
CABLE TRAY Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. Support / rod use from modular type only - approved make - hitech pune / indiana / OBO
225 mm width X 50 mm depth X 1.6 mm thickness
CONDUIT Supply and fixing of following size of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same incase of recessed conduit as required.
D: NETWORK AND SERVER RACKS
SITC of Rack 19'' 42 U 800W/1000D with front Glass Lockable Door, perforated rear door and removable side panels with PD, Castors Set and all accessories Castor ,Tyreman,FT brake & Back STD (set of 4) Fan HSG,90 CFM,4 FAN Fan 230 VAC,90 CFM Mounting Hardware(pkt of 10) X15 Vertical Cable Manager X10 10 Socket Vertical PDUX2 Earthing kit Keyboard Shelf Stationery Shelf 1U, Single-sided horizontal cable manager, finger-duct style 20 No's
Project Management Charges, Pentascanning and OTDR Testing along with 25 years of product performance assurance warranty
ELEVATORS
Supply, installation, testing, commissioning and handing over in satisfactory working condition of Lift complete as required, as per tech specifications - Passenger Lift with following specs Number of Passengers - 15 Rated Load (KG) - 1020 Number of Stops - 8 Travel (meters) - 32 Rated Speed (mps) - 1.75 Lift Well Size (mm) - 2350 (W) X 2000 (D) Machine Room Less (MRL) Doors Center Opening Approx. Overhead (mm) - 4000 Approx. Pit Depth (mm) - 1500 Conventional Control Power Supply 415 Volts, 3 Phase, 50 Hertz AC Digital Direction and Position Indicators in car and at all landings Diffused Lighting in car
BUILDING MANAGEMENT SYSTEM
Supply, installation , testing & commissioning of Server Workstation with minimum: i7 4 core, 3.2GHz, 1 TB HDD, 16GB RAM, 52X CD Writer Drive, along with keyboard, mouse, 21" LED monitor) etc, with Original Windows lifetime license complete as per the detail technical specification and requirement
Supply, installation , testing & commissioning of 9 Inch Five Points Multi Touch Capacitive Screen (800x480 pixel,16:9),RAM: DDR3 512MB and Flash: 4GB based Portable Hand Held terminal along with mounting accessories to mount on DDC Panel if required.
Supply, installation, testing & commissioning of the following Web Based graphical Software. Providing facilities to create static & animate the graphics, navigation between the pages, display of logs, changing the time zones, popup alarms with unlimited user license & unlimited point capacity, configurable password protection for the system and should be able to communicate with LON/BACnet/MSTP devices simultaneously. This software will act as web server & no additional license should require at client side.
Supply, installation , testing & commissioning of Application Software for Building Automation System to run on Windows 10 Professional or equivalent
Supervisory Controllers & Integrators Supply, installation, testing & commissioning of Web Based Network Area Controller for Building Management System (BMS). Network Area Controller Shall support Communication with BMS Controllers (DDC controllers on BACnet/MSTP/Lon) & Other Application Controllers on BACnet, shall support intergation & Communication with Chillers, Secondary Pumps VFD's, Tertiary Pump VFD's, Cooling Towers VFD's, VSPS, AHU VFD's, PAC's, VAV's, DG's, UPS, Hydropneumatic PLC, Multifunction Energy Meters, KWH Energy Meters, Lifts, Fire Alarm Panels, Fire fighting pumps of main pump room, UPS etc on BACnet / MODBUS / LONWORKS. NAC should have dedicated one Lon, RS-485 & RS-232 Port with minimum of 128 MB Flash RAM with Inbuilt WEB Server. (Complete as detailed out in I/O Summary)
For VRV/VRF Units
For VAV Boxes
For VFD's
For DG's
For Energy Meters
For UPS System
For Fire Alarm System
Lift Integration
For All Ceiling Suspended Units / Air Handling Units etc. as required. Not more than 2 AHU's to be clubbed on one Controller
For All Fresh Air Fan Units & Exhaust Air Units etc. as required.
For All Fire Fighting Pump Units etc. as required.
For Plumbing, Water Management System, STP Pumps etc.
For All DG Sets
For Electrical System
Ambient air temperature and humidity sensor
Dual Level IP 67 Level switch for tanks
Differential pressure switch for AHU blower status (0-400 pascals)
Differential pressure switch AHU filter status (0-200 pascals)
Duct type Temperature sensor for supply air temperature monitoring
Wall Type / Duct type Temperature sensor for Return Air Temperature Monitoring
Differential Pressure Transmitter
Level switch for DG fuel tanks (Flame Proof)
DC Voltage Transducer (0-30V DC)
Water Pressure Sensor ( 0 to 10 Kg/cm2)
Wall Mount /Duct type CO2 Sensor
Supply & laying of cabling :
Supply, Installation, Testing & Commissioning of Armoured Communication Cabling, 2Cx1.0 Sqmm twisted pair flexible conductor multi-stranded shielded Insulated FRLS cable complete with erection accessories as required.
Supply, Installation, Testing & Commissioning of Armoured Signal Cabling, 8Cx1.0 Sqmm flexible conductor multi-stranded Insulated FRLS cable complete with erection accessories as required.
Supply, Installation, Testing & Commissioning of Armoured Signal Cabling, 4Cx1.0 Sqmm flexible conductor multi-stranded Insulated FRLS cable complete with erection accessories as required.
Supply, Installation, Testing & Commissioning of Armoured Signal Cabling, 2Cx1.0 Sqmm flexible conductor multi-stranded Insulated FRLS cable complete with erection accessories as required.
Supply, Installation, Testing & Commissioning of Armoured Power Cabling, 3Cx1.5 Sqmm flexible conductor multi-stranded shielded Insulated FRLS cable complete with erection accessories as required.
Hot Dipped Galvanized perforated type Cable tray consisting of continuous, rigid, cable management system, to allow continuous ventilation of cables and maximum dissipation of heat. Provide splices, supports, and other fittings necessary for a complete, continuously grounded system as per the Specs and sizes mentioned
50mm X 50 mm
50mm X 100 mm
50mm X 300 mm
FAÇADE WT 01 Toggle based Curtain wall glazing with Cover Cap Design wind load: 1.74 Kpa and proof load of : 2.61 Kpa . Design, Fabrication,Supply, Installation,Testing, Protection, Cleaning & Handover of glazed Curtain wall system custom designed to with stand the design wind pressure as mentioned above, with microwave cured EPDM gaskets, aluminium chromatised toggles & ss screws. weather sealants, backer rod,MS hot dip galvanized insert channel Bracketing system designed to accommodate seismic movements , with washers, fasteners & nylon separators to prevent bi-metallic contact, Aluminium trims and flashings to seal the gaps between curtain wall and the building structure all complete required to perform as per specification and drawing in conjunction with BOQ. The system shall accommodate IGU of 28mm and 50mm thick aluminium sandwich panel in spandrel area as shown in drawings. The system shall be designed of floor height units spanning between the floors 6 and 7 with face / Slab mounted insert channel brackets, with provision to accommodate seismic movement at all floor levels and at every grid panels horizontally. System shall be mounted on to the bracket arrangement with the help of Anchor Fastener / bolting. The Bracketing system with Aluminium Alloy / MS HDG with built in serration & serrated washers. Brackets to ensure bi metallic corrosion seperators to be in place , and should provide improved thermal performance. The system design shall ensure structural stability, be based on closed joint system & design shall include pressure equalization with minimum 3 barrier gaskets for improved weather performance, drainage at all floor levels. The design to accommodate building movements, thermal expansions & the seismic movements. The system shall be designed considering surface temperatures of 80-90 deg Cel & temperature differential of 25 deg cel without creating excess stress in the system. All metal joints in the wet area shall be small joint sealant applied to ensure water tightness. The system shall be designed to accommodate 28mm IGU in vision area & 6mm heat strengthened glass with Rockwool panel in GI panel in spandrel area . The spandrel panel shall have aluminium adaptor profile to balance the IGU and panel thickness in black anodised. All fix vision glass and openable shall look similar in the elevation. Each glass panel shall be structurally fixed on the main profile using appropriate number and length of chromatised toggle of the system . Each glass panel shall be supported for dead load at the bottom of glass with black anodised glass retainers two per panel. Spandrel shall consist of G.I tray panel coated of approved with 50mm rockwool filling to absorb heat.
The Top Hung Open Out (operable) vent should be with, accessories with heavy duty self balancing stainless steel friction hinges with provision to hold open at 250mm .Vent locking accessories with cremone lock and handle with multi point locking mechanism to keep the vent weather tight. The vent shall comprise of Aluminium outer frame with drainage provisions, crimped corner & shutter frame with Euro grooves with crimped corners. The outer frame fixed to the unitised profile system with necessary SS screws & weather sealant applied from outside. The stepped glass design vent shall have ceramic frit in black at the portion of the stepped unit in case of high light transmission glass to reduce banding effect in the glazing. The three barrier gasket system consists of 1st Barrier of Silicon gasket and 2nd & 3rd barrier of EPDM gaskets to achieve the required compression & seal in the system. EPDM Gaskets shall be of micro cured (Online Curing) with shore A hardness of 60-65. All perimeter to have EPDM membrane sealing done. External groove between glass to be covered with EPDM gasket to give uniform look as well as weather seal. Flashing / Trim / Floor Closure at Parapet level, floor level, beam bottom level and required flashings shall be provided continuously with required GI / Aluminium sheet. Internal & External concealed Flashings shall be 1.0mm thk GI sheet. External exposed flashing shall be 3mm thk. Aluminium sheet with PVDF coated matching with external Aluminium profiles. Internal exposed flashing shall be 2mm thk. Aluminium sheet with powder coated matching with internal aluminium profiles. The fire stop for 2 hr Fire rating with smoke seal at all floor slab levels required as per local fire authority. 100mm thk and 100 Kg/m3 density of Rockwool slab with 1.5mm GI flashing to hold the assembly shall be fixed in compressed form between the gap of Building RCC and Curtain wall system at floor level. Smoke seal intumecent of 10mm shall be applied in the gap of GI flashing and curtain wall assembly. The whole assembly also to act as acoustic assembly between the floors. The fire stop assembly shall run vertical side where there is a shear wall condition or break in horizontal fire stop. The floor closure shall be provided continuously at floor level with 1mm thk GI flashing closing gap between transom and building line with minimum of 10mm gap filled with smoke seal intumecent , sprayable Fire-rated joint spray to provide minimum 2 hours of fire rating when tested as per UL 2079 standard . The product to have up to +_50% Movement Capability and Sound Insulation of 55db as per ASTME-90. The product shall have passed the requirement as specified by ASTM E 1399 class II. The product shall be mould resistant with rating of 0 as per ASTM G21-96 . The product shall carry test certificate as per ASTM E 1399 class II for movement capability. Applicator needs to provide complete installation report for inspection purpose.
The extruded aluminium sections of Alloy 6063 T5 / T6 & tolerances confirming to DIN / EN standard from approved extruder. The structural profiles shall have minimum 2.5mm wall thickness. All the internal visible surfaces shall have high Durability (Akzonobel) / Super durable (Jotun) Powder coating of 60 - 80 micron confirming to AAMA 2604 & all externally visible surfaces shall have PVDF finish with minimum 35 micron confirming to AAMA 2605. The non visible aluminium surfaces shall have minimum chromatizing treatment. All Material Make / Vendor list / Supplier list shall be as per tender specification. (Annexure 1) All shade approval shall be as per Architect's Approval. The system shall demonstrate performance for air seal / water seal / structural /seismic requirement . The system performance test shall be mandatory to verify the design performance meeting the requirement. The performance test shall be carried out at NABL accredited laboratory having fully automised data acquisition system with provision to capture all values directly in the test results sheet . The sequence of test and standard shall be ASTM E 283, ASTM E 331, ASTM E 330 , AAMA 501.1 , AAMA 501.4 Sequence of testing and criteria shall be as per tender Specification. (Annexure 3). No fabrication / installation at site shall be allowed without successful completion of laboratory performance test. Onsite test for workmanship verification shall be carried out in stages for water penetration hose test as per AAMA 501.2 at minimum 6 locations. The quote rate shall include all design, engineering & shop drawing approval from architect & consultant. The quote rate shall include all Taxes, duties, statutory obligations and safety code compliance as per PMC.
Toggle based curtain wall system for types listed below
Spandrel panel : Extra over A.1 Quote extra over on item (a.1) for providing and fixing the spandrel panel with the fire rated Aluminium sandwich panel of 50mm thick. The 50mm thk panel consists of 1mm outer skin of Aluminium with kynar 500 based PVDF paint confirming to AAMA 2605 standard + 48mm FR Grade PUcore material (It shall be Chlorofluorocarbon (CFC) free and self-extinguishing and shall conform to IS 12436: 1988) +1 mm aluminium skin with service coat. (Rate Only) WT-02 and WT-06A
Fire Stop : Extra over A.1 Quote extra over on item (a.1) for providing and fixing the fire stop for 2 hour Fire rating with smoke seal at all floor slab levels required as per local fire authority. - as described above.
Side Hung Operable vent Quote extra over on item (A.1) for providing & fixing the Side Hung Open Out (operable) vent, accessories with heavy duty self balancing stainless steel friction hinges with provision to hold open at 250mm - Gl-8e
"Vision Glass : 28mm IGU Providing & fixing the vision glass on the unitized panel" 6mm performance glass HS + 16mm airgap + 6mm clear FT confirming to the below mentioned parameters SHGC value- .34 and U value 0.58 BTU/hr/ft2F
Z louvers Quote extra over on item (A.1) for providing & fixing powder coated z louvers as shown in the drawings GL-08d
Quote rate for complete system as mentioned above under (B).
Vision Glass : 28mm IGU Providing & fixing the vision glass on the unitized panel
6mm performance glass HS + 16mm airgap + 6mm clear FT confirming to the below mentioned parameters. SHGC value- .34 and U value 0.58 BTU/hr/ft2F
Side Hung Operable vent
Quote extra over on item (B.1) for providing & fixing the Open Out (operable) vent, accessories with heavy duty self balancing stainless steel friction hinges with provision to hold open at 250mm - Gl-1a,Gl-3a,Gl-3c.Gl-4a,Gl-4d
Z louvers Quote extra over on item (B.1) for providing & fixing powder coated z louvers as shown in the drawings
WT-03 Fixed partition walls with Curtain wall system and Patch Fitting doors. Design wind load: 1.1 Kpa and proof load of : 1.55 Kpa . Design, Fabrication,Supply, Installation, Protection, Cleaning & Handover of internal glazed wall system custom designed to with stand the design pressure as mentioned above, with microwave cured EPDM gaskets, & ss screws. sealants, aluminium Bracketing system designed to accommodate seismic movements , with washers, fasteners & Aluminium trims and flashings to seal the gaps between curtain wall and the building structure all complete required to perform as per specification and drawing in conjunction with BOQ. The system shall accommodate IGU of 28mm and 12mm thick TOUGHENED GLASS DOORS area as shown in drawings. The system shall be designed of floor height units spanning between the floors with Slab mounted ALUMINIUM brackets, with provision to accommodate seismic movement at all floor levels and at every grid panels horizontally. System shall be mounted on to the bracket arrangement with the help of Anchor Fastener / bolting. The Bracketing system with Aluminium Alloy with built in serration & serrated washers. Brackets to ensure bi metallic corrosion seperators to be in place , and should provide improved thermal performance. The system design shall ensure structural stability, be based on closed joint system & design shall include pressure equalization with minimum 3 barrier gaskets for improved weather performance, drainage at floor levels. The system shall be designed considering surface temperatures of 10-40 deg Cel & temperature differential of 25 deg cel without creating excess stress in the system. All metal joints in the wet area shall be small joint sealant applied to ensure water tightness. The system shall be designed to accommodate 28mm IGU in vision area & will be a glass to glass memberless joint. All fix vision glass and openable shall look similar in the elevation. Each glass panel shall be structurally fixed on the main profile using appropriate number and length of chromatised toggle of the system . Each glass panel shall be supported for dead load at the bottom of glass with black anodised glass retainers two per panel. Spandrel shall consist of G.I tray panel coated of approved with 50mm rockwool filling to absorb heat. The three barrier gasket system consists of 1st Barrier of Silicon gasket and 2nd & 3rd barrier of EPDM gaskets to achieve the required compression & seal in the system. EPDM Gaskets shall be of micro cured (Online Curing) with shore A hardness of 60-65. All perimeter to have EPDM membrane sealing done. External groove between glass to be covered with EPDM gasket to give uniform look as well as weather seal.
Flashing / Trim / Floor Closure at floor level, beam bottom level and required flashings shall be provided continuously with required Aluminium sheet. Internal & External concealed Flashings shall be 1.0mm thk GI sheet. External exposed flashing shall be 3mm thk. Aluminium sheet with PVDF coated matching with external Aluminium profiles. Internal exposed flashing shall be 2mm thk. Aluminium sheet with powder coated matching with internal aluminium profiles. The extruded aluminium sections of Alloy 6063 T5 / T6 & tolerances confirming to DIN / EN standard from approved extruder. The structural profiles shall have minimum 2.5mm wall thickness. All the internal visible surfaces shall have high Durability (Akzonobel) / Super durable (Jotun) Powder coating of 60 - 80 micron confirming to AAMA 2604 & all externally visible surfaces shall have PVDF finish with minimum 35 micron confirming to AAMA 2605. The non visible aluminium surfaces shall have minimum chromatizing treatment. All Material Make / Vendor list / Supplier list shall be as per tender specification. (Annexure 1) All shade approval shall be as per Architect's Approval. The quote rate shall include all design, engineering & shop drawing approval from architect & consultant. The quote rate shall include all Taxes, duties, statutory obligations and safety code compliance as per PMC.
Toggle based curtain wall system for types listed below
Vision Glass : 28mm IGU Providing & fixing the vision glass on the unitized panel
6mm performance glass HS + 16mm airgap + 6mm clear FT confirming to the below mentioned parameters SHGC value- .34 and U value 0.58 BTU/hr/ft2F
WT-04 Fixed rectangular extruded aluminium fin Design wind load: 1.55 Kpa and proof load of : 2.35 Kpa . Design, Fabrication,Supply, Installation of powder / PVDF coated tube fins on the glazed wall system custom designed to with stand the design pressure as mentioned above, with microwave cured EPDM gaskets, & ss screws. sealants, aluminium Bracketing system designed to accommodate seismic movements , with ss nuts and bolts and silicon sealing to seal the gaps between fin joint and curtain wall complete required to perform as per specification and drawing in conjunction with BOQ. The system shall be designed of floor height units spanning between the floors with Slab mounted / glazing mounted ALUMINIUM brackets, with provision to accommodate seismic movement at all floor levels and at every grid panels horizontally. System shall be mounted on to the bracket arrangement with the help of ss 316 bolting. The Bracketing system with Aluminium Alloy with built in serration & serrated washers. Brackets to ensure bi metallic corrosion seperators to be in place , and should provide improved thermal performance. The system design shall ensure structural stability, be based on system & design at floor levels. The system shall be designed considering surface temperatures of 10-40 deg Cel & temperature differential of 25 deg cel without creating excess stress in the system. All metal joints shall be small joint sealant applied to ensure water tightness. Each fin shall be structurally fixed on the main profile using appropriate number and length of chromatised sword system . Each fin may be supported for dead load at the bottom with black anodised retainers .
Providing & fixing the coated extruded fins on the glazing as shown in drawings
Aluminium fin of size 75 x 250x 3 thick
SKYLIGHT GLAZING SYSTEM: Design, Supply and install skylight glazing system on top of atrium roof to with stand design wind pressure of 190kg/ sq.mtr confirming to IS -875 part III. ( the system must pass the proof load at 1.5 times design wind pressure without any failure ). The profile system shall be based on Conventional skylight system with drainage in Mullion and transom with transom profile stepping on mullion. Provision for condensation drainage in the profile system is must. The system shall be supported on structural steel members & shall accommodate 15.52mm laminated glass held on the grid work by means of mechanical pressure cap on vertical sides and on horizontal sides with structural sealant and Non staining Weather sealants on top side groove or approved make, backer rod, clamping system with hot dip galvanized brackets. The system design shall be designed and proven for use as skylight, meant for use with glass system and to accommodate 15.52mm laminated glass. It will have gaskets for improved thermal performance and weather performance, design shall have transom stepping on to mullion for effective drainage and sufficient gutter size in mullion design to provide continuous drainage from top to bottom, to accommodate building movements, thermal expansions and the seismic movements including thermal stresses created by surface temperature of outer skin material going up to 80-90 deg Cel. without any failure. All metal joints in the wet area shall be small joint sealant applied to ensure water tightness. The design will be completed with provision for ventilation cowl for heat extraction. The structural steel members shall be supported on RCC upstand . Skylight MS structure is made of ISMC sections / Angles / Box sections of Sail or Jindal steel make of first quality confirming to IS 1161 , Secondary members to support the Aluminium grid work for skylight glass. The finish to the exposed steel shall be 1 coat of Epoxy primer and 2 coat of Polyurethane paint. All inline with General arrangement shown in drawing. Steel design and execution shall be part of facade contractor scope. All gaskets in 1st & 2nd barrier shall be made out of EPDM micro cured gasket. Steam cured or nitrite cured gaskets will not be acceptable. Amee rubber ,Goldseal , osaka or Equivalent with micro curing facility shall be approved suppliers. . Anchor bolts shall be of SS 316 grade of make or equivalent. Fasteners shall of SS 316 grade with Dom nut . The Exposed cap profile shall have Anodised paint finish in solid or metallic colors. Internally visible profiles shall have Super durable power coating finish. All external flashing shall be in Anodised paint finish and Internal flashing shall match with the profile finish from inside. The extruded aluminium sections shall be of Alloy 6063 T6 & T5 and tolerances confirming to DIN standard from approved extruder. All the internally visible surfaces shall have Super Durable Powder coating finish of 60-70 micron thickness & all externally visible profile surface with minimum 35 microns Anodised finish. The non visible aluminium surfaces shall have minimum chromatizing treatment. The quote rate shall include all design, engineering & shop drawing approval from architect & consultant. The quote rate shall include all Taxes, duties, statutory obligations and safety code compliance as per PMC.
Skylight system ( as shown) :
Quote rate for complete system as mentioned above under E
Quote rate forms WORKS FOR system as mentioned above .
VISION GLASS:(GLS-1) 15.52mm Laminated :Providing and fixing vision glass on the system.
6mm thk.Clear Fully Tempered Glass + 1.52mm SGP + 8mm thk.Clear Fully Tempered Glass
3 metre aluminium body of dimensions as mentioned in J , with safety brales, 4 number wire ropes of length mentioned, with switching and emergency braking panel provided,. Tested, certified , commissioned for handover
DEMOLITION AND DISMANTLING WORK
Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material outside IIM A Campus at locations approved by local authority as per their rule.
Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material outside IIM A Campus at locations approved by local authority as per their rule.
Carefully removing existing Precast coping (Approx. 365mm wide x 90mm thick), cleaning and stacking at designated place
Dismantling Dholpur stone flooring laid in cement mortar with PCC base including stacking of serviceable material and disposal of unserviceable material outside IIM A Campus at locations approved by local authority as per their rule.
PSP Projects Ltd
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Download all tender documents and submit your bid