Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.5 CrAccepted-AOC 801 VENUS BENECIA PAKVAN DINING LANE OPP RAJPATH CLUB S G HIGHWAY BODAKDEV AHMEDABAD 380053 | AHMADABAD | GUJARAT | 380053 | ₹1.5 Cr | L1 | Accepted-AOC L1 Bidder |
| 2 | L2₹1.5 Cr+₹2.5 L (1.66%)Rejected-Finance | ₹1.5 Cr+₹2.5 L (1.66%) | L2 | Rejected-Finance Not Lowest |
| 3 | L3₹1.5 Cr+₹4.0 L (2.69%)Rejected-Finance | ₹1.5 Cr+₹4.0 L (2.69%) | L3 | Rejected-Finance Not Lowest |
| 4 | L4₹1.5 Cr+₹4.9 L (3.30%)Rejected-Finance OLD JAIL ROAD NEAR JILA GARDEN RAJKOT 360001 | RAJKOT | GUJARAT | 360001 | ₹1.5 Cr+₹4.9 L (3.30%) | L4 | Rejected-Finance Not Lowest |
| 5 | L5₹1.5 Cr+₹5.7 L (3.80%)Rejected-Finance 218 2ND FLOOR U S COMPLEX 120 MATHURA ROAD NEW DELHI 110076 | SOUTH | DELHI | 110076 | ₹1.5 Cr+₹5.7 L (3.80%) | L5 | Rejected-Finance Not Lowest |
Tender Value
₹1.8 Cr
EMD Value
₹3.7 L
Closing Date
12 Jul 2022, 4:00 pmClosed
AGM(E-E)
JPNI Airport, Patna 1st Floor Electrical Department
Annual Maintenance Contract of Electrical Mechanical Installations for Non Operational Area at JPNI Airport Patna For the year 2022 24
2022_AAI_120835_1
AAI/ER/PAT/AGM(E-E) /AMC of Non-operational/e-NIT-
Open Tender
AMC/ Maintenance Contracts
Item Rate
730 days
JPNI Airport
Please refer Tender documents.
17 documents required · 17 mandatory
₹1,120
Yes
₹3.7 L
Yes
1 Aug 2022
1 Jul 2022
13 Jul 2022
1 Jul 2022
12 Jul 2022
1 Jul 2022
1 Jul 2022 - 7 Jul 2022
Amount
Providing Annual maintenance services of Electrical and Mechanical Installations for Power House area i.e Sub-Station, Power House, DG room, CISF Barrack, Project office, Colony Area,Roof top Solar Plant of TB, Pump Room, STP, Car Park Area, street light etc. covering the scope of operation, prevntive and breakdown maintenance, taking rectification action, ensuring serviceability, satisfactory working condition of the system, preventive maintenance, maintenance of records/documents etc. by engaging manpower round the clock basis on all days including sundays & holidays as per detailed specifications, terms & conditions covered under this contract.
For Two Years(Period:- 2022-2024)
Rewinding of the following with Cu-winding wires of required size including less for dismantled copper wire i/c transportation etc. as required (Dismantle cu-wire need not to return).
Ceiling fans (Upto 1400mm Sweep)
Exhaust fans (Upto 300 mm Sweep)
Replacement of bearings(2nos.)/bushes for above fans
Rewinding of burnt motor of submersible pump motor set capacity upto 3 HP of single/three phase with suitable size of Cu-winding wires including sealing of pump motor with sealant material, testing i/c transportation etc. as required. (Burnt Cu Wire need not to return)
Rewinding of burnt motor of submersible pump motor set size 12.5/15HP with suitable size of Cu-winding wires including sealing of pump motor with sealant material, testing i/c transportation etc. complete as required. (Burnt Cu Wire need not to return).
Supply of 12 volt 180 Ampere hour capacity lead acid heavy duty battery without initial charging as reqd.(Make: Exide Xpress Model:-XP-1800 or equivalent approved)
Supply of 12 volt 80 Ampere hour capacity lead acid heavy duty battery without initial charging as reqd.(Make: Exide Xpress Model:-XP-800 or equivalent approved)
Supplying & topping of new insulating transformer oil (ISI mark conforming to IS 335-1993) having BDV not less than 50 KV on existing 11 KV Transformer, AVR etc. complete as required.
Servicing of existing ACB's of various make having capacity of 800A to 1600A i/c drawing out of breaker,cleaning of all contact parts, applying gel, termination of all control wires etc. Repositioning the same, testing and commissioning the breaker, submission of reports etc complete as required as directed by EIC.(Spares will be supplied by AAI ).
Servicing of existing 11 KV VCB's of various make i/c drawing out of breaker, cleaning of all contact parts, applying gel, termination of all control wires etc. Repositioning the same, testing and commissioning the breaker, submission of reports etc complete as required as directed by EIC. (Spares will be supplied by AAI ).
Filteration of transformer oil including dehydration & removal of carbon particles in order to improve the Breakdown voltage strength of the oil including BDV testing before & after filteration and submission of test report for existing 11KV Transformer, HT AVR etc. complete as required as directed by EIC.
Calibration and testing of IDMT relays through secondary injection machine which is having valid calibration certificate and submission of test reports as required.
Calibration and testing of measuring instruments i.e Insulation tester, Clip on Meter, Earth Tester etc and submission of test reports as required.
Calibration and testing of Buchlotz Relay for 11/.433 KV Indoor Oil Cooled Transformers and submission of test reports as required.
Dismantling,Lifting,repairing and lowering capacity upto 3 H.P. submersible pump motor set i/c column pipe,cable, ,jointing of submersible cable and sealing of pump motor with sealant material, testing commissioning including arranging of tripod stand, chain pulley block etc.complete as required.
Dismantling,Lifting, repairing and lowering of capacity upto 15 H.P. submersible pump motor set i/c column pipe,cable, jointing of submersible cable and making connection,testing commissioning including arranging of tripod stand, chain pulley block etc.complete as required.
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required. Group B
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
4 X 2.5 sq. mm + 2 X 2.5 sq. mm earth wire
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
4 X 4 sq. mm + 2 X 4 sq. mm earth wire
2 X 6 sq. mm + 1 X 6 sq. mm earth wire
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed PVC conduit as required.
3 x 1.5 sq. mm
3 x 2.5 sq. mm
3 x 4 sq. mm
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
5/6 amps switch
15/16 amp switch
3 pin 5/6 amp socket outlet
6 pin 15/16 amp socket outlet
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.
3 Module (100mmX75mm)
6 Module (200mmX75mm)
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
12 way, Double door
Supplying and fixing following way, vertical type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
4 way (4 + 12), Double door
8 way (4 + 24), Double door
Exacavation for cable trenches in soft soil, depth upto 1.2 m including refilling of soil, dressing of sides i/c ramming, watering and getting out of disposal of surplus excavated soil as directed, within a lead of 50 metres.
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required.
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
3.5C X 35 sq. mm (32mm)
3.5C X 70 sq. mm (35mm)
3.5CX 95 sq. mm (38mm)
3.5C X 120 sq. mm (45mm)
3.5C X 185 sq. mm (57mm)
3.5C X 240 sq. mm (62mm)
Servicing of existing all type desert water cooler including supply of new suitable khash, repairing/replacement of water pump, repairing/rewinding of motor, repairing for water leakage, cleaning, painting of inside & outside surface by metal enamel paint etc. complete as required.
Supply of Khash
Supply of Water Pump
Repairing/Rewinding of Motor
Inside & Outside surface of Metal enemal paint.
SAURABH ENTERPRISES
Ruhi Electronics
DOSHI ELECTRIC ENGG. CO.
CIS GLOBAL INFRATECH PRIVATE LIMITED
SRS ENGINEERS
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .