| 1.00WIRING IN STEEL & PVC CONDUIT | |||||||
| 1.01Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. | |||||||
| 1.01 | Group C | 25 | Point | 1,400 ₹35,000 | 1,005 ₹25,125 Lowest | 1,100 ₹27,500 | 1,106 ₹27,650 |
| 1.02Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. | |||||||
| 1.02 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire | 10 | Metre | 500 ₹5,000 | 417 ₹4,170 | 285 ₹2,850 | 272 ₹2,720 Lowest |
| 1.02 | 4 X 6 sq. mm + 2 X 6 sq. mm earth wire | 20 | Metre | 850 ₹17,000 | 810 ₹16,200 | 510 ₹10,200 Lowest | 521 ₹10,420 |
| 1.02 | 4 X 16 sq. mm + 2 X 6 sq. mm earth wire | 25 | Metre | 1,400 ₹35,000 | 1,568 ₹39,200 | 1,250 ₹31,250 Lowest | 1,627 ₹40,675 |
| 1.03Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. | |||||||
| 1.03 | 3 x 1.5 sq. mm | 225 | Metre | 130 ₹29,250 | 92 ₹20,700 | 130 ₹29,250 | 73 ₹16,425 Lowest |
| 1.03 | 3 x 2.5 sq. mm | 220 | Metre | 150 ₹33,000 | 144 ₹31,680 | 160 ₹35,200 | 110 ₹24,200 Lowest |
Tender Value
₹7.7 L
EMD Value
₹15,400
Closing Date
18 Sept 2025, 6:00 pmClosed
Director
NIT Calicut, NIT Calicut Campus PO, Kerala, 673601
Electrical Works for Dynamics and Vibration Laboratory in E-Cube Resource Building
2025_NITC_875033_1
Engg/EMU/JE03/0019/Dynamics and Vibration Lab and Engg/EMU/JE03/0020/Incomer Dynamics Lab
Open Tender
Electrical Works
Item Rate
45 days
NIT Calicut, NIT Calicut Campus PO, 673601
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹15,400
Yes
10 Oct 2025
28 Aug 2025
22 Sept 2025
28 Aug 2025
18 Sept 2025
28 Aug 2025
Amount
WIRING IN STEEL & PVC CONDUIT
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Group C
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
2 X 6 sq. mm + 1 X 6 sq. mm earth wire
4 X 6 sq. mm + 2 X 6 sq. mm earth wire
4 X 16 sq. mm + 2 X 6 sq. mm earth wire
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
3 x 1.5 sq. mm
3 x 2.5 sq. mm
3 x 4 sq. mm
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
1 or 2 Module (75mmX75mm)
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc., including supplying and fixing ball and socket arrangement, 2 Nos. down rods of 20 mm dia X 1.6 mm thick steel conduit upto 30 cm length, painting and wiring the down rods and connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
Supplying and fixing extra down rod of 10 cm length G.I. pipe ,15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.
Group A
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings).
MCCB, MCB & DB'S
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
8 way , Double door
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MOB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MOB TPDB is normally used where 3 phase outlets are required.)
8 way (4 + 24), Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MOB DB complete with connections, testing and commissioning etc. as required.
Single pole
Double pole
Triple pole
Triple pole and neutral
Supplying and fixing single pole blanking plate in the existing MOB DB complete etc. as required.
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supply Installation Testing and Commissioning of 28W 1200 mm sweep 5 Star rated BLDC ceiling fan with input voltage range (140-285V), 380 rpm, Air delivery 235 m3/min, regulator supported type, Aluminium Blade material ,white colour,with 3 years onsite warranty, conforming to IS:374:2019 latest including, required length, painted down rod (GI) providing and fixing Suitable type fan hooks including connections,welding etc. as required.
FAN HOOK
Supplying and fixing of 8/10 mm "S" type steel fan hook including chipping,welding, painting making good the damages etc. as required
LIGHTING
RECESS TYPE LED
Supply and fixing of 1X4 LED Recess Mount Luminaires (Crompton Span, LCTLRNE-40-CDL(1X4) or equvalent) with Efficacy >100 lm/W, CCT>5600K ANSI.Including necessory clamps, screws, fastners etc. as required.
LED TUBELIGHT
Supply of box type tube fittings (Batten ) compatible for fixing 2 T8 LED tube light, complete with side holders etc, as required.(Batten- IGP162LT8-16 2XT8 or compatible)
Supply and fixing of 18/20 watt 4 feet T8 LED tube with efficacy 100lm/W. (T8 LED-Crompton LGT8-20-865-2 or compatible)
SWITCH AND SOCKETS
Supplying and fixing 20/25 A modular DP switch on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
Supplying and fixing 3 pin 25 A modular socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
HORIZONTAL DB
Supplying and fixing 4 way, single pole and neutral Double door, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
REMOVAL
Charges for removing the existing switchboards and making good the damages including paintings other accessories wirh out any damage and conveyance of the materials to the godown etc as required.
Charges for removing the existing light fittings( PVC conduit/ wires) and making good the damages including paintings other accessories wirh out any damage and conveyance of the materials to the godown etc as required.
Removal of existing 1 Phase, SPN DB, making good the damges of the wall/floor including cement,sand, paint and other accessories without any damages and conveyance of the materials to the godown etc as required
SUBMAIN TERMINATION
Supplying and making end termination of PVC insulated copper conductor 4x16+ 2x6 sqmm submain wiring with suitable size Copper lugs including connection etc as required.
Supply, Installation, Testing and Commissioning of Sub-Main distribution Board on surface/recessed with 250A MCCB as incomer-1 No and 8 Nos of 100 A MCCB as outgoings, sheet steel, powder coated and suitable busbar rating for operation on 440V,50Hz, 3 phase AC supply. Without MCCB and extension boxes, complete connections, Danger sign board, Stickering, etc, as required/directed by the EIC.(Compatible L&T SMDB Enersys-S or Equivalent).
Supply, Installation, Testing and Commissioning of Bottom Cabling Box suitable for Sub- Main Distribution Board on surface/recessed with 250A MCCB as incomer-1 No and 8 Nos of 100 A MCCB as outgoings (Compatible L&T SMDB Enersys-S or Equivalent).
Supply and fixing of 250A 3 pole MCCB suitable for SMDB, with thermal magnetic protection including necessory arrangement for fixing on exixting Panel/SMDB etc. as required.
Supply and fixing of 63-100A 3 pole MCCB suitable for SMDB, with thermal magnetic protection including necessory arrangement for fixing on exixting Panel/SMDB etc. as required.
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel,fabrication works ,connecting MCCB to copper busbar link(suitable size Cu link to be supplied) and making connections, etc. as required.
250 A,36KA,FPMCCB
100 A,30KA,FPMCCB
Supply and fixing of Rotary Handle Extended ROM suitable for switches rated up to 250A including necessory arrangement for fixing on exixting panel etc. as required.
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.
300 mm width X 50 mm depth X 1.6 mm thickness
Supplying and fixing 3 phase 8 way , double door, suface/recess mounting, vertical type, 415 V, TPN distribution board with provision for fixing MCCB as incomer and TP MCB as out going, complete with 200 A tinned copper bus bar, common neutral link, earth link, din bar for mounting MCBs, detachable gland plate, interconnections, earthing, phosphatized and powder painted, fixing using bolt and nut, giving connections etc. as required. (But without MCCB, MCB)
Supplying and fixing 100A, 16kA, 4 pole (Three pole and Neutral), 415 V, Moulded casing circuit breaker (MCCB) in the existing MCCB DB , complete with connections, testing and commissioning etc, as required.
Supplying and fixing 40-63A , Triple pole, 430 V, C curve Miniature circuit breaker (MCB) in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supply of 1.1 kV grade 3.5C x 70 sq.mm, Aluminium conductor XLPE insulated PVC sheathed armoured power cable as required.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.
Above 95 sq. mm and upto 185 sq. mm
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.
Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)
Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
3.5C X 70 sq. mm (38mm)
3.5C X 35 sq. mm (32mm)
3.5C X 150 sq. mm (50mm)
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.
Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
Supply of 1.1 kV grade 3.5C x 150 sq.mm, Aluminium conductor XLPE insulated PVC sheathed armoured power cable(as per IS ) as required.
Supply and laying one number of the 8 SWG good quality bare copper wire along the cable with connections etc. as required
Supplying and fixing 4 way, single pole and neutral Double door, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
4 X 6 sq. mm + 2 X 6 sq. mm earth wire
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MOB DB complete with connections, testing and commissioning etc. as required.
Triple pole and neutral
Nev Tech (BID ID -3284334)
JAITECH ENGINEERS (BID ID -3277779)
LAMOS TECHNOLOGY SOLUTIONS PVT LTD (BID ID -3284705)
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .