| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.0 LAccepted-AOC PATEL NAGAR SUNDAR NAGAR BHURKUNDA RAMGRAH | NA | NA | 825101 | ₹35.0 L | L1 | Accepted-AOC As per NIT |
| 2 | L2₹35.5 LRejected-Finance | ₹35.5 L | L2 | Rejected-Finance As per NIT |
| 3 | Rejected-Technical | - | - | Rejected-Technical As per NIT |
| 4 | Rejected-Technical | - | - | Rejected-Technical As per NIT |
| Sl No | Description | Qty | Unit | M/S RAJENDRA CIVIL AND ELECTRIC WORKS L1 | M/S SANTOSH ELECTRIC L2 |
|---|---|---|---|---|---|
| 2.00 | Wiring for circuit/sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor single core cable in surface/recessed PVC conduit as required. 2 X 6 sq. mm + 1 X 6 sq. mm earth wire | 3,200 | Mtrs | 400 ₹12.8 L | 405 ₹13.0 L |
| 3.00 | Wiring for circuit/sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor single core cable in surface/recessed PVC conduit as required. 4 X 16 sq. mm + 2 X 6 sq. mm earth wire. (Main switch to DB Box) | 60 | Mtrs | 1,250 ₹75,000 | 1,275 ₹76,500 |
| 4.00 | Supplying and fixing of following ways surface/recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 8way(4+24)Double door. | 20 | Nos | 9,500 ₹1.9 L | 9,750 ₹1.9 L |
| 5.00 | Supplying and fixing 5 Amps to 32 Amps rate 240 V ‘C’ series MCB suitable for inductive load of following poles in the existing MCB DB complete with connections testing and commissioning etc as required. Double Pole. | 120 | Nos | 650 ₹78,000 | 650 ₹78,000 |
| 6.00 | Supplying, installation, testing and commissioning of following capacity TPN tap off box made of 1.6 mm thick sheet steel enclosure duly painted with power coating on existing rising mains complete with TPN disconnector FUS and HRC fuses, connections, earthing etc as required. 100 amp TPN. | 20 | Nos | 13,000 ₹2.6 L | 13,200 ₹2.6 L |
| 7.00 | Laying of one number PVC insulated and PVC insulated and PVC Sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation , sand cushioning , protective covering and refilling the trench etc as required. up to 35 sq.mm. | 320 | Mtrs | 375 ₹1.2 L | 390 ₹1.2 L |
| 8.00 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. up to 35 sq. mm (clamped with 1mm thick saddle). | 440 | Mtrs | 60 ₹26,400 | 75 ₹33,000 |
| 9.00 | Supplying and making end termination with brass compression gland and aluminum lugs for following size of PVC insulated and PVC sheathed / XLPE aluminum conductor cable of 1.1 KV grade as required. 4x25 sq. mm (28 mm) | 40 | Nos | 400 ₹16,000 | 400 ₹16,000 |
| 10.00 | Earthing with G.I. earth Plate 600 mm x 600 mm x 6 mm thick including accessories, and providing masonry with cover plate heaving locking arrangement and watering pipe of 2.7 metre long etc . with charcoal/coke and salt as required . | 40 | sets | 7,000 ₹2.8 L | 7,500 ₹3 L |
| 11.00 | Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required. | 400 | Mtrs | 170 ₹68,000 | 165 ₹66,000 |
Tender Value
₹32.2 L
EMD Value
₹40,300
Closing Date
26 Mar 2026, 10:00 amClosed
STAFF OFFICER ENM
CRS Barkakana
Replacement of damaged Sub main wiring, Main switch, Distribution Board and MCB of 20 Nos. Blocks (120 Units) 1B type of NTS Colony, Barkakana.
2026_CCL_356789_1
CRS/BRK/ SO(EnM)/NIT/2025-26/18
Open Tender
Electrical and Maintenance Works
15 days
CRS BARKAKANA
Please refer Tender documents.
2 documents required · 2 mandatory
₹40,300
9 Jun 2026
16 Mar 2026
27 Mar 2026
17 Mar 2026
26 Mar 2026
17 Mar 2026
17 Mar 2026 - 23 Mar 2026
Wiring for circuit/sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor single core cable in surface/recessed PVC conduit as required. 2 X 6 sq. mm + 1 X 6 sq. mm earth wire
Wiring for circuit/sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor single core cable in surface/recessed PVC conduit as required. 4 X 16 sq. mm + 2 X 6 sq. mm earth wire. (Main switch to DB Box)
Supplying and fixing of following ways surface/recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 8way(4+24)Double door.
Supplying and fixing 5 Amps to 32 Amps rate 240 V ‘C’ series MCB suitable for inductive load of following poles in the existing MCB DB complete with connections testing and commissioning etc as required. Double Pole.
Supplying, installation, testing and commissioning of following capacity TPN tap off box made of 1.6 mm thick sheet steel enclosure duly painted with power coating on existing rising mains complete with TPN disconnector FUS and HRC fuses, connections, earthing etc as required. 100 amp TPN.
Laying of one number PVC insulated and PVC insulated and PVC Sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation , sand cushioning , protective covering and refilling the trench etc as required. up to 35 sq.mm.
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. up to 35 sq. mm (clamped with 1mm thick saddle).
Supplying and making end termination with brass compression gland and aluminum lugs for following size of PVC insulated and PVC sheathed / XLPE aluminum conductor cable of 1.1 KV grade as required. 4x25 sq. mm (28 mm)
Earthing with G.I. earth Plate 600 mm x 600 mm x 6 mm thick including accessories, and providing masonry with cover plate heaving locking arrangement and watering pipe of 2.7 metre long etc . with charcoal/coke and salt as required .
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
Providing of PVC/XLPE insulated PVC sheathed aluminum armoured conductor cable 1100V, 25 sq.mm, 3.5 Core. (Reputed Make).
Total impact of GST for the purpose of CTC
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 2.55 MB
BOQ_369651.xls
BOQ • 0.25 MB
Download all tender documents and submit your bid