Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹51.7 LAccepted-AOC 2ND FLOOR PLOT NO 338 UDHYOG VIHAR PHASE IV GURUGRAM 122015 HARYANA | GURUGRAM | HARYANA | 122015 | L1 | Accepted-AOC Lowest | |
| 2 | L2₹71.9 L+₹16.6 L (30.0%)Rejected-Finance 315 INDUSTRIAL AREA II PANCHKULA 134113 | PANCHKULA | HARYANA | 134113 | L2 | Rejected-Finance Highest |
Tender Value
Refer Docs
EMD Value
₹89,580
Closing Date
8 Dec 2020, 5:00 pmClosed
Ritesh Nandal
Executive Engineer, Electrical Division, PWD B and R Br., Ambala Cantt.
Construction of Mukund Lal Civil Hospital at Yamuna Nagar (Pdg. LAN and EPABX system).
2020_HRY_151704_1
PWD/Elect-KNL/Elect-AMB/110123
Open Tender
Construction Works
Works
60 days
Ambala Cantt
Please refer Tender documents.
3 documents required · 3 mandatory
₹5,000
₹89,580
19 Apr 2021
25 Nov 2020
9 Dec 2020
25 Nov 2020
8 Dec 2020
25 Nov 2020
Amount
NS-1 SITC of STP Cat 6 UTP Cable, Transmission frequency of 250 MHz (Minimum),Cable should have 69% NVP. Cable should be FR-PVC and EIL certified.(R&M/Systimax/Seimon).
NS-2 SITC of information outlet belongs to Category 6, EIA/TIA 568-C.2 Information outlets along with dual port face plate in PVC material. Should accept cables from 22-24 AWG copper, Should be PCB free and Tool less will be added advantage, Information outlet should be of Halogen Free material, Should be Certified by independent labs like ETL/GHMT/3P for compliance. Make:(R&M/Systimax/Seimon).
NS-3 SITC of CAT6 UTP 24 AWG Patch Cord - 2 mtr with cross separator with IDC certified , Cable should be onforming to the following standards like EN 50173, ISO/IEC 60603-7 & 11801/IEC 60332-1, UL VW-1 Complete as per specification / approved & desired by the Engineer in charge. Make R&M//Systimax/Beldon
NS-4 SITC of 2-port with dust cover faceplate including back box and all other accessories As per specification. Make & Model: R&M/AMP/Beldon
NS-5 SITC of 24-port 19" 1 U jack panel which Should Be made of sheet steel 1.5 mm, Should be 19" 1U straight Patch Panel, 24-port, Should have integral cable management Metal shelf,Should accept Shielded as well as Unshielded jacks which should be toolless termination. Should have rear cable management shelf metallic powder coated. Make: (R&M/Systimax/Seimon)
NS-6 SITC of 0.5 Mtr UTP Cat6 cable which Should be Compliant with Cat.6 requirements of ISO/IEC 11801, EN 50173, EN 50168 and EIA/TIA 568.C.2, Should be stranded bare copper, Should be unshielded. Make:(R&M/Systimax/Seimon)
NS-7 SITC of OFC Armoured outdoor SINGLE MODE 6 CORE - OS2 . Should be ISO.IEC 11801 - 2nd Edition, type OS2 and ITU-T REC G 652D. Tube Idenification :Single tube/Multiple tube. Fibre protection (Tube) : Polybutylene Terephthalate (PBT). Water Blocking :Thixotropic Gel (Tube) and Petroleum Jelly (Interstices). Core Wrapping : Polyethylene Terephthalate . Armouring : Corrugated Steel Tape Armour (ECCS Tape). Strength Member: Two Steel wires on periphery/Two FRP rods on periphery /Central Strength Member FRP. Sheath : UV Stabilized Polyethylene (HDPE). Maximum. Tensile Strength-Short Term : 1500N or better. Mass (Nominal) : minimum 95 kg/km Make:(R&M,Siemon,Systimax)
NS-8 SITC of 24 Port fiber LIU which have sufficient slots to accommodate 24/12 Duplex LC/SC Ports ,Should have fiber management provision inside with splice tray and other accessories, Should be rack mountable 1U,Should have Splice holder for minimum 24 Fiber cores ,Should be made of Cold Rolled Steel ,Material Should steel: 1.5 mm with powder-coated. LIU should have rack mount with channel with uppersheet openable for fiber management. Make:(R&M,Siemon,Systimax)
NS-9 SITC of 6 Port fiber LIU which have sufficient slots to accommodate 24/12 Duplex LC/SC Ports ,Should have fiber management provision inside with splice tray and other accessories, Should be rack mountable 1U,Should have Splice holder for minimum 12 Fiber cores ,Should be made of Cold Rolled Steel ,Material Should steel: 1.5 mm with powder-coated. LIU should have rack mount with channel with uppersheet openable for fiber management. Make:(R&M,Siemon,Systimax)
NS-10 SITC of optical fiber patch leads shall comprise of Singlemode category Jacket should be LSZH sheath,Connector: Zirconia ceramic ferrule,Conector type Duplex LC-LC with length of 3 mtr.Make:(R&M,Siemon,Systimax)
NS-11 SITC of fiber adaptor which have LC Duplex singlemode adapter with Quick mounting clip integrated.Protection class of IP-20 rated with Material :fiber- (halogen-free )Make:(R&M,Siemon,Systimax)
NS-12 SITC of fiber pigtail which have Connector type LC, Fiber Type SM OS2,Compact design (SFF). 1.25 mm ferrule technology, Length 1meter/1.5 meter.Make:(R&M,Siemon,Systimax)
NS-13 SITC of 9U wall mount rack with 500 depth. Rack have loaded accessories like FAN with 5 socket PDU with 15 AMP DP for power surge safty. With pole mount accessories. Rack should ISObe certified. Make: Valrack,Netrack,Rittal
NS-14 SITC of 27U indoor rack with 800X800 high density rack with framework with 2 Horizental and 2 Vertical channel with 4 FAN tray roof cabinet. 1 Top Cover and 1Bottom Cover with gland plate and rubber grommets for cable entry provisions,4 Recess mounting angles, with PVC cable separation cable manager. Rack should be certified. Make: Valrack,Netrack,Rittal
NS-15 SITC of splicing and Optical connectivity test report for per core of OFC
NS-16 SITC of Single mode fiber module with with 1000 base ( Module should be of same OEM as quoted for switch)
NS-17 SITC of Layer-2 managed Gigabit Ethernet 1RU chassis with 24 port 10/100/1000 BaseT ports and 2 Gigabit SFP ports. Includes an internal AC power supply 380W power budget) with a power cord, manuals access card, and RJ-45 to DB-9 adaptor. The Access Switch should have 4 ports of 1 G SFP. The Access Switch should provide Non-Blocking switch fabric capacity of 56 Gbps or more. L-2 switch should provide wire-speed packet forwarding of 41 Mpps or more. L-2 Switch should support min 16K MAC addresses and min 4000 active VLANs. The Access Switch Should be EAL2/EAL3/NdcPP certified Make: Cisco/ Juniper/Alcatel/Extreme.
NS-18 SITC of Layer-3 24-port giga managed switch with 4 nos SFP and 4 nos SFP plus.Switch should have Switch should be Manged, IEEE 802.3az EEE support,IEEE 802.3x flow control,IEEE 802.3z 1000BASE-X,IEEE 802.1p CoS,IEEE 802.3af PoE, IEEE 802.3at PoE Plus, IEEE802.1Q VLAN Tagging, Minimum 8 VLAN supportPort based VLAN, IEEE802.3ad link aggregation should be MAC based Switching Capacity 165 Gbps,Packet buffer 192KB,MAC address support 4K Jumbo frame support 9K, Should support loop detection,Should support Broadcast storm control QoS Support (WRR and strict priority) Port based QoS 20 Multicast group or higher, Maximum power consumption 72W,Operating temperature 0°C to 40°C Storage Temperature -40°C to 70°C Certification: CE, FCC, C-Tick, , LVD EN60950-1, ROHS compliant.Switch Should be EAL2/EAL3/NdcPPd be built-in IEEE 802.3az Energy Efficient Ethernet (EEE). Make:Cisco/Juniper/Alcatel/Extreme
NS-20 SITC of IP-Phone with LED screen and 2 port lines with call transfer facility and should be certified EN 61000-6-1 (Immunity for residential and commercial environments ) Make:Alcatel/Cisco/Avaya
NS-21 SITC of IP-Phone with LED screen and 1 port lines and should be certified EN 61000-6-1 (Immunity for residential and commercial environments ) Make:Alcatel/Cisco/Avaya
31.44 (ii) Supply and erection of PVC pipe ISI marked ( Medium ) recessed in wall / ceiling etc. including the cost of PVC bends , inspection boxes , iron hooks and cement concrete etc. complete in all respect upto the entire satisfaction of Engineer-in-charge of work. 25 mm dia. (Rates as per HSR 31.44)
Insat Techno Services
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .