| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.7 LAccepted-AOC CHENNAI TAMIL NADU 600015 | CHENNAI | TAMIL NADU | 600015 | L1 | Accepted-AOC L1 | |
| 2 | L2₹17.1 L+₹2.4 L (16.4%)Rejected-Finance 10 646 F MAROTTIKKALS AMINA TOWER MANJUMMEL MANJUMMEL ERNAKULAM KERALA 683501 | ERNAKULAM | KERALA | 683501 | L2 | Rejected-Finance documents verified | |
| 3 | L3₹17.9 L+₹3.3 L (22.2%)Rejected-Finance | L3 | Rejected-Finance documents verified | |
| 4 | L4₹20.4 L+₹5.8 L (39.3%)Rejected-Finance 47 MURUGESA NAICKER COMPLEX GREAMS ROAD THOUSAND LIGHTS CHENNAI TAMIL NADU 600006 | CHENNAI | TAMIL NADU | 600006 | L4 | Rejected-Finance documents verified | |
| 5 | Rejected-Technical | - | Rejected-Technical document verified |
Tender Value
Refer Docs
EMD Value
₹18,000
Closing Date
24 Jul 2021, 5:00 pmClosed
REGISTRAR
KFRI, PEECHI
Providing 4 and 16 degree cold room at Seed center, KFRI, Peechi.
2021_KCSTE_429581_1
KFRI/957/2021 TOE/cold rooms
Open Tender
Electrical Works
Item Rate
30 days
KFRI, PEECHI
Please refer Tender documents.
7 documents required · 7 mandatory
₹2,400
₹18,000
Yes
28 Oct 2021
10 Jul 2021
26 Jul 2021
10 Jul 2021
24 Jul 2021
10 Jul 2021
Amount
Supplying and fixing 60 mm thick PUF panels on wall and ceiling,with painted coat SS 0.4mm sheet both inside and outside, bolted to the roof and walls with necessary angles , channels, silicon sealant, GI rods, nuts, bolts, washers etc.. complete.
Supply and fixing PUF Insulated Stainless Steel finished door of size .90X 2 mtr with all fittings like SS hinges, SS lock etc. Complete including accessories anti condensation door heater, part lock system, auto recloser, human safety release knob
providng and laying in position specified grade of reinforced cement concrete excluding the cost of centering shuttering finishing and reinforcement 1:3:6
Providing and laying 12 mm cement plaster of mix 1:4
SITC of factory assembled DX type 30,000 btu Refrigeration unit operating temperature +2 to 16 degre ) on R404 complete as specified and comprising as under .All frames supports shall be of Galvanised steel all units shall comply to ECBC norms with regard to its energy efficiancy…Hermetically sealed energy efficiant reciprocating compressor as specified operating on R 404......Air cooled condensor with low noise fan and corrossion resistant blue fins ...Indoor unit(4500 cfm) with centrifugal DIDW blowers , high efficiancy DX cooling coil , 20 micron washable flat pre filters , insulated sanviched drain pan and pendant remote control.... Indoor and out door units casing shall be of GSS construction with powder coated finish....Necessaray mountig arrangements for indoor and out door units with suitable vibration isolaters......Micro processor based control centre with all necessary controls and protecive devices, thermal protection for compressor......Insulated refrigerant piping out of soft drawn copper pipes using 5/8" and 3/8"duly insulated with13 mm nitrile rubber pipe sleeves.1 year warranty
Wiring for light point/fan point/exhaust fan point/ call bell point with 1.5 sq mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit , with modular switch, modular plate , suitable GI box and earthing the point with 1.5 sq. mm. FRLS PVC insulated copper conducter single core cable etc. are required.
Supplying and drawing following sizes of FRLS PVC insulated copper coductor, single core cable in the existing surface/recesed PVC conduit as required 5X4 sq. mm
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
double pole
Tripple pole
Tripple pole and Neutral
Supplying and fixing following rating, four pole, (3 phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40A
Supplying and fixing following way prewired TP&N MCB distribution board Vertical Type of steel sheet for 415 volts on surface/ recess complete with loose wire box, terminal connectors for all incoming and outgoing circuits, duly prewired with suitable size FRLS PVC insulated copper conductor up to terminal blocks, tinned copper bus bar, neutral link, earth bar, din bar, detachable gland plate, interconnections, powder painted including earthing etc. as required.(But without MCB/ RCCB/ Isolator). 8 way (4 + 24), Double door
Providing and fixing 2mm thick aluminium chequered plate of approved pattern & design after laying puf slab and mica sheets, made out of machine cut aluminium sheet and machine holed for receiving dash fastener, over expansion joints on vertical surfaces/ ceiling and floors, the fixing on plate in one row on one side of joint only shall be done with stainless steel dash fastners of 8 mm dia and 75 mm long bolt including providing aluminium - washers 2 mm thick 15 mm dia, at a staggered pitch of 200 mm centre to centre including drilling holes in the receiving surface and providing expandable plastic sleeves in holes etc. complete as per direction of Engineer -in-charge.
Eakcon systems pvt ltd
Eco Cooling Solutions
NEW THRISSUR ASSOCIATES
BEARDSELL LIMITED
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.PDF
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .