Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.5 LAccepted-AOC | L1 | Accepted-AOC 1st Lowest | |
| 2 | L2₹46.0 L+₹5.5 L (13.6%)Rejected-AOC | L2 | Rejected-AOC 2nd Lowest |
Tender Value
₹41.3 L
EMD Value
₹50,000
Closing Date
1 Nov 2024, 3:00 pmClosed
The Executive Engineer Electrical HEED Harbour Eng
O/o The chief Engineer, Harbour Engineering Electrical Division, Kamaleswaram, TVPM
PMMSY_Expansion of Kasaragod Fishing Harbour_Upgradation of electrical installation and providing additional light mast_General Electrical Work
2024_HED_698547_1
HED/CEHED/TR/289/2024_6_5_4/1
Open Tender
Electrical Works
Item Rate
60 days
Kasaragod
Please refer Tender documents.
7 documents required · 7 mandatory
₹2,760
₹50,000
20 Jan 2025
21 Oct 2024
4 Nov 2024
21 Oct 2024
1 Nov 2024
21 Oct 2024
Amount
Yard Lighting and Cable Laying
1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
1.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm
1.17.30:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 6 sq. mm
1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
1.24.3:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
2.21:Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
1.28.1:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.1 or 2 Module
1.28.2:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.3 Module
14.12:Providing 15mm thick cement plaster of mix 1:4(1 cement: 4 fine sand) at all levels
14.7:Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc including form work etc as required.
14.1:Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres.
90.15.4.11:Supply Conveyance, installation, testing and commissioning of 200W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
90.6.6.1:Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes.1.50 sq mm
90.14.10.1:Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.16 A-100A, 16 kA (Ics=100%Icu), 3 pole, current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL
14.13.1:Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required50 mm dia
7.5.1:Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Upto 35 sq. mm
90.12.7.42:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 25 sq mm with factory made clamp
90.12.7.41:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp
90.12.7.40:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with factory made clamp
90.12.7.39:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 6 sq mm with factory made clamp
90.12.5.41:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.4 core 16 sq mm
90.12.5.42:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.4 core 25 sq mm
90.12.5.40:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.4 core 10 sq mm
90.12.5.39:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.4 core 6 sq mm
9.1.21:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 35 sq. mm (32mm)
90.3.18.3:Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut and welded to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required.40 mm dia with clamps made from 20 x 3 mm MS flat
9.1.34:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 25 sq. mm (28mm)
9.1.33:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)
9.1.32:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)
90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
90.16.1.5:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.75 mm copper conductor (6 SWG)
5.17:Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
5.13:Providing and laying earth connection from earth electrode with 4.00 mm dia copper wire in 15mm dia G.I. pipe from earth electrode including connection with copper thimble excavation and re-filling as required.
5.14:Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
5.5:Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt ) as required.
5.3:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt ) as required.
90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)
90.16.5.4:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.4.00 mm (8 SWG)
90.16.5.5:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.4.75 mm (6 SWG)
7.10:Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required.
90.12.9.2:Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench50/38 mm or nearest size
90.12.9.3:Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench63/50 mm or nearest size
2.10.4:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole
2.10.3:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole
OD1159/2024-2025:Supplying and fixing surface /recess mounting Vertical TPN distribution board with Double door , dust and water proof IP 66 Hensel make FP VN 0412 opaque or equivalent , 8+12 4 way DB of poly carbonate inclusive of tinned copper 250A busbar, common neutral link, earth bar, din bar for mounting MCB's with provision for MCCB as incomer.
90.10.1.2:Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )2 module moulded plastic box on surface
90.10.1.3:Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )3 module moulded plastic box on surface
90.12.7.28:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 35 sq mm with factory made clamp
90.14.10.3:Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.16 A-100A, 16 kA (Ics=100%Icu), 4 pole, current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL
90.15.2.3:Supply installation testing and commissioning of High Mast using Octogaonal Pole made single/two sections of hot dip galvanised GI sheet 100mm top diameter, 360mm bottom diameter thickness 3mm mm suitable for wind speed as per IS 875 Part III with head frame assembly two point suspension system with steel wire rope 5mm dia double drum winching system w and including round arm galvanized luminary carriage suitable to install 6/8 nos luminaries in symmetrical arrangement control gear box and lighting spikes with single phase operation power tool installed inside the base compartment including connector foundation bolt 4 nos fixed in existing RCC foundation and junction box etc, complete 12 Meters
OD1160/2024-2025:Supply and installation of wall mounting cubicle type dust and vermin proof size 4 , 600x300x214 mm, Mi2410 thermoplastic meterbox with provision for fixing KSEB meter.Supply and providing 3 Nos of 63A HRC porcelain fuse units with 40A HRC fuse link and 1No 63A 2way porcelain neutral link in the meter portion. Necessary holes are to be provided in the box for entry and exit of wire The inter connection should be done using 10.0 sq.mm copper wire.
OD1165/2024-2025:Supply and installation of wall mounting cubicle type dust and vermin proof size 4 , 600x300x214 mm, Mi2410 hinged type thermoplastic box with 25A,16 kA,TP MCCB with 32A 2 way porcelain neutral link and rotary handle , one set phase indication lamp,2A C-curve MCB - 3 Nos ,Panel surface mounting 96sq.mm backlit LED Multifunction meter three line display to read V,A,KVA,,PF and frequency of make Schneider or equivalent suitable for 415V ,50Hz - 1 No,30/5 tape wound class 1 CT -3 Nos. Sufficient holes for fixing phase indication lamp, multifunction meter and rotary handle in the thermoplastic box are to be provided. Necessary interconnection with suitably rated copper conductor with copper socket are to be provide.
OD1804/2024-2025:Supply and fixing of 20/5, 30/5, 40/5 A, 5 VA, accuracy class 5, Tape wound Metering CT
OD1803/2024-2025:Supply and fixing 50/5, 75/5 A, 5 VA, accuracy class 3, Tape wound Metering CT
OD1800/2024-2025:Supplying 16mm dia LED type Phase indication lamp(Red , Yellow ,Blue & Green)
OD1799/2024-2025:Supply and installation of Three phase 4 wire electronic 5A kwh panel mounting 96x96mm meter
OD1795/2024-2025:Supply and installation of Panel surface mounting 96 sqmm LED Multi function meter to read V,A, kVA, kVAr, PPF and frequency suitbale for 415 volts, 50 Hz
OD5375/2024-2025:Engaging labours for dismantling the light fittings, checking the electrical installations, rectifying defects, etc if any as per the direction of the departmental officers at the site - Wireman
OD5376/2024-2025:Engaging labour for replacing the existing installations like removing old SB , DB, etc complete as directed by the engineer in charge and stacking the materials in safe place complete. Khallasi
OD1505/2024-2025:Scaffolding charges for dismantling and repairing work and replacing damaged flood lights complete with all charges at site as required.
OD1385/2024-2025:Scrapping and cleaning the surface and painting two coats of best quality synthetic enamel paint of approved color over two coat of epoxy based industrial primer on electrical panel /street light pole etc including all cost of labour and materials complete as required .
OD5514/2024-2025:Supply and providing 12 mm thick,1m x 2m electrical grade Checkered type rubber mat to withstand 15 KV dielectric strength conforming to IS 5429 / 1969.
OD5531/2024-2025:Supply and providing 6Kg stored pressure ABC Powder type Fire Extinguisher with hose and clamps including all fixing accessories and fixing it to wall as directed by Department officials complete.
OD5381/2024-2025:Supply and providing 25x6 mm brass bolt and nut with washers on the existing MS box / earth bus etc. as required including drilling necessary holes as required
OD1140/2024-2025:Supply and fixing IP 65 HENSEL 1 row 9 module( Model No KV 7109) KV thermoplastic circuit breaker boxes with PE + N Terminals on the surface using suitable size stainless steel screws.
OD5676/2024-2025:Supply and installation of wall mounting cubicle type dust and vermin proof 300x600x170 mm, Hensel make polycarbonate Enclosure - IP66 size 4 box K0400 or equivalent in wall with all fixing accessories and cutting holes for bus bar arrangement and sealed with suitable binding agent including 5 pole terminal set 2 nos suitable for 10sqmm cable and .3mtr. 20x6mm cu strip as earth bus complete as required.
OD1149/2024-2025:Supply and installation of wall mounting cubicle type dust and vermin proof size 4, 600x315x214 mm, Hensel Mi 9410 make thermoplastic meter box with provision for fixing KSEB meter, cut out & Neutral link, with sufficient holes for fixing KSEB electronic energy meter, cut-outs and neutral link. Supply and provide 1No of 20A,16kA, Triple Pole MCCB with rotary drive kit, 1 No of 32A HRC fuse units with 20A HRC fuse link, and 1No 32A 2way neutral link in the meter portion. Necessary holes are to be provided in the box for the entry and exit of the wire. The interconnection should be done using 4.0 sq.mm copper wire.
OD1133/2024-2025: Supply of 16M High mast shaft in two sections suitable for wind speed as per IS Standard, with raising lowering system comprising, head frame, luminaries carriage suitable to install 08 nos luminaries in symmetrical arrangement, double drum winch, 5mm diameter SS wire rope, trailing cable, connector, integral power tool motor, manual handle, junction box, lightning finial. (Wiring material from JB to individual luminaire & MCB in base compartment are not included and are a part of installation).Supply of foundation bolts manufactured from special steel along with nuts, washers, anchor plate and common template.Supply and installation of 8 numbers of LED floodlight type BENP 20FL 350W LED.Supply of LED type single dome aviation obstruction light.Supply of outdoor stand mounted feeder pillar with 32A TPN MCB incomer, single dial time switch, 25A TP contactor for the automatic switching of luminaries, power tool control with 2 no 9A contactors and raise lower push button, Incoming 35 sq. mm and out going 16 & 2.5 sq. mm terminals.Erection part: Construction of shallow foundation with M20 grade concrete for the highmast considering the safe soil bearing capacity at site as 10T/sqmtr at 2 metre depth with all materials and labour. Erection of the high mast with the help of suitable tools and plants, wiring of luminaires with all wiring materials like PVC insulated PVC sheathed flexible cable of suitable copper conductor cores of 1.5 sq.mm, lugs, MCB and all labour. Provision of GI pipe earthing for High mast with 2 M long 40 mm dia GI Pipe including connection to High mast earth terminal with 25 x 3mm GI flats with all materials and labour. (2nos per mast required). Installation of the mast feeder pillar by grouting the stand in concrete.
OD5293/2024-2025:Supply and installation of Extra length of foundation bolt of size 24mm diameter , 385mm pitch circle diameter manufactured from special steel in existing concreate with suitable stiffener piece complete as required.( suitable for 12 M highmast system)
OD5374/2024-2025:Supply and installing RCC precast well steining of size 900mm dia and 300m height complete with all expense at site.
OD1154/2024-2025:Supplying and making end termination nickel plated single compression brass cable gland for 2 core 2.5 sq mm PVC insulated and PVC sheathed armored copper conductor cable 1.1 KV grade, including providing earth clip and superior quality copper cable socket.
OD5227/2024-2025:Supply and fixing Cable Junction Boxes IP 65 for outdoor applications (Thermoplastic Polycarbonate ) suitable for cable sizes 2.5 sq.mm ,80 X 80X 52 mm Cape model Abox i025 or equivalent and accessories for Cable Junction Boxes such as Copper Terminal Set 2.5 sq.mm 5 Pole 1 No,Support for Terminal 1No including fixing the accessories using suitable size Stainless steel Bolt and nut, giving necessary connections, making good the damages etc. as required
OD1152/2024-2025:Supply and fixing Cable Junction Boxes IP 66 for outdoor applications( with metric knock outs for cable entry - Black Color)) suitable for cable sizes up to 16/25 sq.mm, 200 X 160 X 98 mm Hensel model No KF 5255 or equivalent and accessories for Cable Junction Boxes such as Terminal Set 2.5 sq.mm / 4 sq.mm including giving necessary connections, making good the damages etc. as required.
OD1135/2024-2025:Supply of 4 core 2.5 sq mm PVC insulated and PVC sheathed armoured copper control cable
OD1722/2024-2025:Supply of 2 core 2.5 sq mm PVC insulated and PVC sheathed armored copper control cable
OD1134/2024-2025:Supplying and making end termination nickel plated single compression brass cable gland for 4 core 2.5 sq mm PVC insulated and PVC sheathed armoured copper conductor cable 1.1 KV grade, including providing earth clip and superior quality copper cable socket.
OD1142/2024-2025:Supplying and fixing of surface/ recess mounting, vertical type, 415 volts,Dust and waterproof ,IP66 Hensel make or equivalent FPVN 0811 opaque door( 8 + 24 way) VTPN poly carbonate distribution board , with provision for MCCB as incomer .
OD1145/2024-2025:Supply and installation of wall mounting cubicle type dust and vermin proof size 4 , 600x300x214 mm, Mi2410 thermoplastic box including supply and fixing 63A, 25kA,4pole MCCB with BUC rotory drive kit , 230V ac shunt release ,ELR with CBCT including giving connection using 10.0 sq.mm pvc insulated copper wire, and 2A SPMCB with RYB indication lamp and wiring the circuit with 2.5 sqmm copper wire complete.
OD1739/2024-2025:KSEB Documentation Charge for new connection or enhancing the load including all essential documentation fees file work giving application follow up for getting connection / expansion all work complete
Gate House Electrification
1.10.1:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group A
1.10.2:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group B
1.10.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C
1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
1.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm
1.17.30:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 6 sq. mm
1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
1.25:Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
1.26:Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
1.49:Numbering of ceiling fan / exhaust fan/ fluorescent fittings as required.
1.27.1:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)
1.31:Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
1.32:Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
1.33:Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
1.34:Supplying and fixing brass batten/ angle holder including connection etc. as required.
2.11:Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.14.1:Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps
5.3:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt ) as required.
5.13:Providing and laying earth connection from earth electrode with 4.00 mm dia copper wire in 15mm dia G.I. pipe from earth electrode including connection with copper thimble excavation and re-filling as required.
5.14:Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
5.17:Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
90.16.5.4:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.4.00 mm (8 SWG)
90.4.1:Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required.
90.4.5.4:Supply, Installation, testing and commissioning of ceiling fan of following sizes including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. 1200mm sweep - ceiling fan complete with service value minimum 4.0(cub meter/minute/Watt), Air delivery minimum 210(cubic meter/minute), Copper winding suitable for 230V/240V single phase AC supply
90.3.19.3:Supply conveyance, installation, testing and commissioning the light fittings of following types made from CRCA sheet 0.5mm thickness with all accessories and lamps directly on wall and giving connections with 16/0.20 mm 3 core PVC insulated and sheathed round copper conductor flex wire or extending the original wiring and giving connections as required1200 mm 1X20W LED Lamp with box type fixture
OD5304/2024-2025:Supply and installation of wall mounting cubicle type dust and vermin proof CAPE make BRES 43,or equivalent. 400 x 300 x 200 mm Glass Fibre Reinforced Polyester Enclosure with hinged door, IP66, IK 10 outdoor meter box or equivalent with base plate for fixing KSEB meter, cut out &Neutral link and 20A , 10kA SPN MCB, C curve , with sufficient holes for fixing KSEB electronic energy meter, cut outs and neutral link. Supply and providing 1No 20A,10kA ,SPNMCB C curve , 1 No 32A HRC fuse units with 20A HRC fuse link and 1No 32A 2way neutral link in the meter portion. Necessary holes are to be provided in the box for entry and exit of wire. The inter connection should be done using 4sq.mm copper wire.
OD5307/2024-2025:Supply and installing 7+/-2W LED bulkhead fitting (IP 65), housing made of die cast aluminium with 6500K colour temperature with a lumen output minimum 100lumen/Watt, CRI>80,beam angle 120 degrees, suitable for outdoor applications, including all connections etc. as required. Make -Philips -Vista glow or equivalent
90.15.4.1:Supply Conveyance, installation, testing and commissioning of 20W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD Less than10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
90.3.18.3:Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut and welded to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required.40 mm dia with clamps made from 20 x 3 mm MS flat
OD5378/2024-2025:Supplying and fixing HENSEL make KV -thermoplastic circuit breker boxes IP65 with metrick knock out for cable entry, 1 row 12 module size 295x333x129 KV9112 M with PE+N terminals
OD5379/2024-2025:Supply of Philips or equivalent 7/9-Watts Multipack B22 LED Cool Day White LED Bulb.
OD5382/2024-2025:Supply and providing 25x6 mm brass bolt and nut with washers on the existing MS box / earth bus etc. as required including drilling necessary holes as required
Toilet Block Electrification
1.10.1:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group A
1.10.2:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group B
1.10.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C
1.25:Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
1.33:Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
1.34:Supplying and fixing brass batten/ angle holder including connection etc. as required.
1.26:Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
1.27.1:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)
1.31:Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
1.49:Numbering of ceiling fan / exhaust fan/ fluorescent fittings as required.
90.3.19.3:Supply conveyance, installation, testing and commissioning the light fittings of following types made from CRCA sheet 0.5mm thickness with all accessories and lamps directly on wall and giving connections with 16/0.20 mm 3 core PVC insulated and sheathed round copper conductor flex wire or extending the original wiring and giving connections as required1200 mm 1X20W LED Lamp with box type fixture
90.4.1:Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required.
90.4.5.4:Supply, Installation, testing and commissioning of ceiling fan of following sizes including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. 1200mm sweep - ceiling fan complete with service value minimum 4.0(cub meter/minute/Watt), Air delivery minimum 210(cubic meter/minute), Copper winding suitable for 230V/240V single phase AC supply
90.4.8:Charges for cutting holes suitable for accommodating exhaust fans up to 305mm sweep including plastering colour washing etc. as required.
90.3.17.2:Supply, conveyance and erection of the following sizes of 'B' class GI pipe in single section for post top lantern of all types on concrete base (excluding charges for concrete base and excavation) and painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer etc. as required.40 mm dia GI pipe
90.15.4.1:Supply Conveyance, installation, testing and commissioning of 20W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD Less than10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
OD5306/2024-2025:Supply and installation of Heavy duty exhaust fan with metal blade, totally enclosed continuously rated capacitor started and run of 300mm ,1400Rpm,240V,90W, Max air delivery of 1710 m3/hr with louvers ,fixing accessories complete as required.
OD5383/2024-2025:Supply and installing 7+/-2W LED bulkhead fitting (IP 65), housing made of die cast aluminium with 6500K colour temperature with a lumen output minimum 100lumen/Watt, CRI>80,beam angle 120 degrees, suitable for outdoor applications, including all connections etc. as required. Make -Philips -Vista glow or equivalent
OD5384/2024-2025: Supplying and fixing Osram /Philips or equivalent CLASS A B22 7/9-Watt LED Lamp
Auction Hall Electrification
7.7.1:Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Upto 35 sq. mm (clamped with 1mm thick saddle)
1.10.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C
1.26:Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
1.17.30:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 6 sq. mm
1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
1.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
1.24.3:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
1.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
1.24.5:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
1.33:Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
1.41:Installation, testing and commissioning of pre - wired, fluorescent fitting/ compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
2.13.1:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.15.2:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
14.7:Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc including form work etc as required.
14.12:Providing 15mm thick cement plaster of mix 1:4(1 cement: 4 fine sand) at all levels
90.3.18.3:Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut and welded to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required.40 mm dia with clamps made from 20 x 3 mm MS flat
90.4.1:Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required.
90.15.4.2:Supply Conveyance, installation, testing and commissioning of 36/40W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
90.4.2:Supply and installation of suitable size MS belt type fan clamp fabricated from flat iron 40 x 6 mm, 150mm long x 2 Nos with M.S. rod bent to shape, neatly painted with 2 coats of enamel paint over a coat of red oxide primer as per IS 732 as required.
90.15.4.7:Supply Conveyance, installation, testing and commissioning of 100W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
90.10.1.2:Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )2 module moulded plastic box on surface
90.10.1.3:Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )3 module moulded plastic box on surface
90.10.1.5:Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )6 module moulded plastic box on surface
OD5226/2024-2025:Supply and fixing Cable Junction Boxes IP 65 for outdoor applications (Thermoplastic Polycarbonate ) suitable for cable sizes 2.5 sq.mm ,80 X 80X 52 mm Cape model Abox i025 or equivalent and accessories for Cable Junction Boxes such as Copper Terminal Set 2.5 sq.mm 5 Pole 1 No,Support for Terminal 1No including fixing the accessories using suitable size Stainless steel Bolt and nut, giving necessary connections, making good the damages etc. as required
OD5386/2024-2025:Fabricating, supplying, and fixing tubular post of overall height of 3m using 65mm Heavy G.I. Pipe having ISI mark and of approved quality as per the drawing, with a 12mm thick GI flange and Table E dummy Flange suitable for 65mm heavy duty C class pipe at the top of the post and 75mm x 40mm C channel welded on the top of the flange with bolt holes to fix the lamps and fixing 2 Nos clamp made out of 50 x 6 mm GI flat at the bottom using 8 Nos 12mm stainless steel screws and fixing the pole on the top of the roof by drilling concrete through roof slab along the side of the pillar up to 60 cm length onwards.The post is to be painted with two coats of best quality industrial epoxy paint over two coats of industrial epoxy primer .Cable entry provision by inverted Y arrangement d at the top making good the damages by filling the hole with 1:1.5:3 concrete mix , plastering ,colour washing etc complete
OD5413/2024-2025:Supply and installation of IP65 rated, LED 70w,270V,50Hz,5700 K Highbay LED, Bay light , System efficacy is 150 lumens/watt, with driver .Designed for operations under diverse environments ranging from -10C to 50C, IK08 polycarbonate cover provides strong protection under harsh conditions, Aluminium die-cast ADC1 - alloy grade (EN AC-47100) Pressure die-cast housing offers excellent corrosion-resistance and robustness have Mounting device like Eye-Bolt with all accessories complete as required. Preferred make Philips Green Perform Prime or equivalent.
OD5414/2024-2025:Supplying and making end termination nickel plated single compression brass cable gland for 2 core 2.5 sq mm PVC insulated and PVC sheathed armored copper conductor cable 1.1 KV grade, including providing earth clip and superior quality copper cable socket.
OD5415/2024-2025:Supply of 2 core 2.5 sq mm PVC insulated and PVC sheathed armored copper control cable
1.28.1:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.1 or 2 Module
1.49:Numbering of ceiling fan / exhaust fan/ fluorescent fittings as required.
90.6.5.11:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sq mm
90.6.6.1:Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes.1.50 sq mm
90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)
1.28.2:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.3 Module
1.28.4:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.6 Module
OD5532/2024-2025:Supply and providing 25x6 mm brass bolt and nut with washers on the existing MS box / earth bus etc. as required including drilling necessary holes as required
OD5533/2024-2025:Engaging labourers for dismantling the light fittings, checking the electrical installations, rectifying defects, etc if any as per the direction of the departmental officers at the site - Wireman
OD5388/2024-2025:Conveyance, installation, testing and commissioning of departmentally supplied flood light luminaire with lamp and control gear on the existing tubular post of height up to 15m from ground level
OD5385/2024-2025:supply of weather proof LED luminaire having power consumption not more than 40 W and light output not less than 4500 lm with system efficiency >120 lumens/watt. Luminaire housing made from superior quality of polycarbonate extrusion IP65 and and IK 08 protection. The luminaire should be having minimum 30000 Burning hours with CRI >=80 and co related colour temperature(CCT)of 6500K. Preferred make Philips WT 150C LED 40S-6500 PSU L120 or equivalent
OD5534/2024-2025:Engaging labour for replacing the existing installations like removing old SB , DB, etc complete as directed by the engineer in charge and stacking the materials in safe place complete. Khallasi
Netmending Shed Maintenance
OD5296/2024-2025:supply of weather proof LED luminaire having power consumption not more than 40 W and light output not less than 4500 lm with system efficiency >120 lumens/watt. Luminaire housing made from superior quality of polycarbonate extrusion IP65 and and IK 08 protection. The luminaire should be having minimum 30000 Burning hours with CRI >=80 and co related colour temperature(CCT)of 6500K. Preferred make Philips WT 150C LED 40S-6500 PSU L120 or equivalent
1.41:Installation, testing and commissioning of pre - wired, fluorescent fitting/ compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
OD5411/2024-2025:Engaging labourers for dismantling the light fittings, checking the electrical installations, rectifying defects, etc if any as per the direction of the departmental officers at the site - Wireman
OD5412/2024-2025:Engaging labour for replacing the existing installations like removing old SB , DB, etc complete as directed by the engineer in charge and stacking the materials in safe place complete. Khallasi
Civil work
5.22.1:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelMild steel and Medium Tensile steel bars
15.2.1:Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
15.3:Demolishing R.C.C. work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material with in 50 metres lead as per direction of Engineer -in-Charge.
SAFIYULLA K V
Bidder Name
M K V Engineering
SAFIYULLA K V
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1090136.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .