Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹57.3 LAccepted-AOC INDEX NO B 48 HQ CE SWC JAIPUR A 202 RATHRAM PANORAMA GALA GIMAKHANA ROAD NEAR AMMANJARI BUNGLOWS SOUTH BOPAL AHMEDABAD 380058 | AHMEDABAD | AHMEDABAD | GUJARAT | 380058 | L1 | Accepted-AOC L1 AND ACCEPTABLE | |
| 2 | L2₹58.1 L+₹79,024.70 (1.38%)Rejected-AOC | L2 | Rejected-AOC NOT L1 | |
| 3 | L3₹59.4 L+₹2.1 L (3.61%)Rejected-AOC 274 210 DAFNALA ROAD SHAHIBAUG AHMEDABAD GUJARAT 380009 | AHMADABAD | GUJARAT | 380009 | L3 | Rejected-AOC NOT L1 | |
| 4 | L4₹61.6 L+₹4.3 L (7.43%)Rejected-AOC H NO 209 D SHRI SHIVA NAGAR IV MANCHARA SIKAR ROAD JAIPUR | JAIPUR | JAIPUR | RAJASTHAN | 302013 | L4 | Rejected-AOC NOT L1 | |
| 5 | Rejected-Technical | - | Rejected-Technical TWO CLASS BELOW |
Tender Value
₹59.5 L
EMD Value
₹1.1 L
Closing Date
26 Mar 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE AHMEDABAD
CWE AHMEDABAD
ADDN/ ALTN TO BLDG NO NP-176, 812 FD WKSP COY AT AHMEDABAD
2022_MES_505534_1
87067
Open Tender
Civil Works
Item Rate
240 days
AHMEDABAD
Please refer Tender documents.
6 documents required · 6 mandatory
₹1,000
GE (ARMY) AHMEDABAD
₹1.1 L
25 May 2022
3 Feb 2022
28 Mar 2022
3 Feb 2022
26 Mar 2022
14 Mar 2022
60 days
Amount
Providing and applying 4 mm thick epoxy self-smoothening flooring on concrete surface having moisture content less than 5% as per the following specification:- (a) Surface Preparation – Carry out surface preparation including grinding of concrete surface, proper cleaning, removing of loose mortar, paint residuals, curing compound residues. (b) Joints, Pot hole filling finishing & Crack Sealing – Repairing of floor cracks and dents using epoxy putty. Opening up construction joints, cracks (if any) on floor in V-groove type and fill up the same using epoxy mortar to avoid cracks in epoxy flooring system. Potholes will also be treated by epoxy mortar. (c) Applying one coat of epoxy penetration primer to seal the microporosity in concrete and again applying one coat of sealer coat solvent free epoxy primer in floor by brushor roller all as per manufacture and instruction as directed by Engr-in-Charge. (d) Applying high performance 2 mm thick self level epoxy screed coat comprising of a 3 component system comprising resin base, resin hardener and fillers, carried out on the cured Primer Coat to minimize the undulations in the floor. It should be applied as per manufacture instruction through authorised applicators as directed by Engr-in-Charge. (e) Applying 2.0 mm thick Epoxy top coat laid on the cured screed system consisting of graded aggregates bound in a pigmented epoxy resin binder to be supplied as a four component system, pre-weighted for on-site mixing, to provides a smooth, light reflective surface. The colour of finished surface shall be as approved by GE. The entire epoxy flooring shall provide abrasion resitstance and good aesthetic appearance to the satisfaction of GE. Material consumptions and application shall be as per manufacture instruction through authorised applicators as directed by Engr-in-Charge. Makes for Epoxy Flooring :- M/s Fosroc Chemicals, M/s STP Limited, M/s Choksey Chemicals Pvt. Ltd., M/s Thermax Ltd., M/s BOSTIK India Pvt. Ltd., M/s Sika India Pvt Ltd.
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for. Complete all as specified and as directed.
Excavation in trenches n. exc. 1.50 m wide and n exc 1.5 m in depth and getting out in hard/ dense soil. Complete all as specified and as directed.
Removing excavated material exc 50 m & not exc 250 m and depositing where directed (soils) at a level not exc. 1.5 mts above the starting point. Complete all as specified and as directed.
Material & Labour for broken stone hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete. Complete all as specified and as directed.
Material & Labour for 100mm thick PCC 1:3:6 type C2 (40 mm graded aggregate) as in Sub base floor finished even and rough to receive the top layer. Complete all as specified and as directed.
Material & Labour for 200mm thick PCC 1:2:4 type B2 (40 mm graded aggregate) as in floor finished even and fair. Complete all as specified and as directed.
Material & Labour for complete removal of the existing treatment on internal walls and preparation of old surfaces and applying two coats of oil bound distemper over a coat of primer. Complete all as specified and as directed.
Material & Labour for Preparing old steel surfaces girth exc. 10 cm girth and applying one coat of synthetic enamel paint. Complete all as specified and as directed.
Hacking out old broken glass (any thickness, size, quality or description) from metal frame including punching or drilling out old glazing pins/spring clips and providing and fixing new ones. Complete all as specified and as directed.
Supply & Fixing of sheet glass ordinary quality 3 mm thick in squares n. exc. 0.50 sqm in each pane and glazing with oil putty complete. Complete all as specified and as directed.
Material & Labour for point wiring with 1100 volts grade PVC insulated FRLSH multistranded copper conductor cable 1.5 sqmm (Phase - R,Y,B, Neutral - Black) and earth continuity conductor 1.5 sqmm (Green) drawn into and including concealed in PVC concealed/ conduit and pressed steel terminal boxes (for mounting switches/ sockets/ regulators/ ceiling roses etc) PVC conduit medium grade not less than 20 mm dia ISI marked ivory colour with all conduit fittings/ fixing accessories and sunken galvanized pressed steel terminal boxes of thickness not less than 1.2 mm covered with suitable a required size of Hylum sheet 3 mm thick top, for mounting switches, sockets, fan regulators complete including making good the wall surfaces with matching colour on wall for the following:- Note : The wast of this item will including Cutting chases,pinning in ,making good for facings where required and pointing the cement mortar 1:3 to ends or edges of landings, steps, cills, sun shades, shelves, lintels etc and cutting chases for concealed conduit wiring etc and making good, cutting not exceeding 10 cm grith. Complete all as specified and as directed.
One light point or one fan point controlled by one switch SP one way 230 Volts. Make Havells/ Polycab/ Finolex/ RR Kabel. Complete all as specified and as directed.
One socket outlet 6 amp controlled by one switch on the same board with other switches. Make Havells/ Polycab/ Finolex/ RR Kabel. Complete all as specified and as directed.
One socket outlet 6 amp controlled by one switch on indepdendent board. Complete all as specified and as directed.
All as per srl item No 12.00 here in above but for one 3 pin 15 Amps socket outlet independent with 4 sqmm PVC insulated unsheathed copper conductor single core multi strand flexible cable and 4 sqmm PVC insulated unsheathed copper conductor single core cable (green color) as earth lead. Complete all as specified and as directed. Make Havells/ Polycab/ Finolex/ RR Kabel
Material & Labour for switch Piano flush type single pole one way 5/6 Amp Make:Anchor/ Havells/ Legrand. Complete all as specified and as directed.
Material & Labour for switch,socket combination 2 in 1, 3 pin, 5 and 16 Amp flush type all as specified and directed. Make:Anchor/ Havells/ Legrand. Complete all as specified and as directed.
Material & Labour for socket outlet 2 in 1, 3 pin, 5 Amp flush type all as specified and directed. Make:Anchor/ Havells/ Legrand. Complete all as specified and as directed.
Supply and fixing of fan regulator electronic type with hum free with 4/5 steps 240 volts complete all as directed. Make:Anchor/ Havells/ Legrand. Complete all as specified and as directed.
Material & Labour for ceiling rose 2-3 terminal size 65 x 20 mm. Complete all as specified and as directed. Make:Anchor/ Havells/ Legrand.
Supply & fixing of sheet metal enclosure with SPN DB's 8 way (grouted in walls) double door type IP-43 Protection. Isolated Neutral, Door earthing, cement spill protector, IK-08 complete including cutting chases to wall for fixing DB and making good the disturbed wall surface all as required at site and as directed by Engr-in-Charge (Outgoing MCB will be measured separately). Make: Legrand/ Hager/ Indoasian. Complete all as specified and as directed.
Supply & Fixing of distribution board iron clad, with double door 4 way with IP-43,IK-09 protection suitable for MCCB as incommer AC 415 Volts four pole with thermal release adjustable type (80% to 100 % ) and MCB as outgoing ,complete with appropriate size copper bus bar and neutral link complete with one MCCB 4 pole 415 Volts 160 Amps rating with rupturing capacity 36 KA of the same make as of distribution board & including cutting chases to wall for fixing DB and making good the disturbed wall surface all as required at site or directed by Engr-in-Charge (Outgoing MCB will be measured separately). Make:Legrand/ Hager/ Indoasian. Complete all as specified and as directed.
Material & Labour for 6 to 32 Amps MCB SP ( ISI Marked) 50 C/S 10 KA 'C' Curve all as specified all as directed. Make:Legrand/ Havells/ Indoasian. Complete all as specified and as directed.
Supply & fixing of MCB 6 to 32 Amp SPN 50 C/S 10 KA 'C' Curve all as specified all as directed. Make:Legrand/ Havells/ Indoasian. Complete all as specified and as directed.
Supply & Fixing of Sheet metal metal box 32 amp, single pole and neutral, socket outlet, (3P+N+E), metal enclosed plug top in power coated CRCA steel sheet enclosure recess mounted with chained cover for the socket outlet with and including one number TPN 'C' series MCB 32 amp as required. Make:Legrand/ Hager/ Indoasian. Complete all as specified and as directed.
Supply and Fixing of Alluminium Batten LED 20 watt tube light fiiting complete with decorative type fitting 4 feet long with Light Linear with its bright light output at 100 lumen/ watt give ultra wide light distribution batten type built in electronic driver, open circuit protection surge voltage protection upto 10kv complete including all accessories prewired and connecting electrically to ceiling rose using PVC insulated and overall sheathed flexible copper conductor cable of size 0.75 sqmm 3 core 6500K (Note:- fittings shall be fitted on two plastic square/ round block. Note power factor should not be less than 0.90 all as required and specified at site or directed. Complete all as specified and as directed.
Supply & Fixing of Highbay/ Mediumbay LED 60 watt energy saving, environment friendly and robust, luminaire with high efficacy , made out of aluminium alloy pressure die casted housing, powder coated of colour grey finish & control gear box of , tempered protective toughened glass, built in electronic driver open circuit protection, surge voltage protection upto 10 KV with built in SPD as per IS with mounting suspended by means of heavy duty nickel plate. Complete all as specified and as directed. Make: Philips Model No-BY416P LED 230S CW SK60 FGPSU GR or Equilent in Havells/ Wipro
Material & Labour for Sub main wiring in PVC concealed conduit with 2 Nos single core FRLSH PVC insulated copper conductor cable FR-LSH size 4 sqmm (Phase - R,Y,B, Neutral - Black) multistrand in concealed conduit with 4 sqmm FR-LSH PVC insulated FR-LSH as earth continuity wire using suitable size of copper thimble including provn of PVC coduit heavy duty ISI marked of adequate size. Complete all as specified and as directed. Make-Havells/ Polycab/ Finolex/ RR Kabel
Material & Labour for Sub main wiring in PVC concealed conduit with 4 Nos single core FRLSH PVC insulated copper conductor cable FR-LSH size 6 sqmm (Phase - R,Y,B, Neutral - Black) multistrand in concealed conduit with 2X6 sqmm FR-LSH PVC insulated FR-LSH as earth continuity wire using suitable size of copper thimble including provn of PVC coduit heavy duty ISI marked of adequate size. Complete all as specified and as directed. Make-Havells/ Polycab/ Finolex/ RR Kabel
Material & Labour for Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (Earth pit not less than 2.25 Mtr deep below normal ground level) with top edge of the plate not less than 1.5 Mtr below normal ground level connecting with galvanized iron GI earth wire 4 mm dia by means of bolt nut check nuts and washers of galvanized iron and provision of GI tubing medium grade (ISI marked) of size 15mm for protection of GI earth wire upto test point, 20 mm dia GI light grade watering pipe with funnel and wire mesh, RCC pit cover of size 300 x 300 x 40 mm reinforced with XPM having weight not less than 4Kg/ sqmm including 6 mm thick MS bar handle made to shape, PCC pit with 1:3:6 type C1 with angle iron frame made of angle iron of size 40x40x4mm, adequate qty of charcoal dust and salt layers all around the earth plate, excavation , earth work in any type of soil, removal of excavated soil and returning filling in all as required at site complete all as specified in plate No 3 of SSR Part-I and all as specified or indicated including testing on completion.NOTE :-Rates inclusive of necessary excavation in any type of soil, earth work, PCC pit, RCC cover, funnel with watering pipe, GI earth strip upto 10 m long for connecting to test point etc. all as required at site for complete earthing). Complete all as specified and as directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 Sqmm 3.5 core. Complete all as specified and as directed.
Excavation in trenches in any type of hard/ dense soil n exc 1.5 mtr in width and n. exc 1.5 mtr in depth and getting out all as required for laying of cables, Foundation filling of poles or stays. Complete all as specified and as directed.
Returning filling, in including spreading ,leveling, watering and well ramming in layers not exc 25 cm each all as required. Complete all as specified and as directed.
Removing excavated material to a distance not exceeding 50 meters and depositing where directed at a level not exc 1.5 mtr above the starting point. Complete all as specified and as directed.
Material & Labour for good quality dry sand cushioning to under ground electric cable on layer of 8 cm thick before laying the cable and second layer of 15 cm thick after laying the cable all as specified in clause 19.75 of MES Schedule part-I (2009) Note : Sand shall be fined sand as specifed and punned thickness shall be measured and paid. Complete all as specified and as directed.
Supply and laying sub class 'B' bricks of old size (230 x 115 x 75 mm) or of size locally available, laid along alignment of cable as protection to cable in trenches. Complete all as specified and as directed.
Taking down carefully aluminium or copper submain wiring with PVC casing caping/ PVC surface conduit and making good disturbed surfaces complete. Complete all as specified and as directed.
Taking down carefully surface aluminium or copper point wiring with PVC casing-caping (light, fan, socket, bell or power) including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc and making good disturbed surfaces complete. Complete all as specified and as directed.
Material & Labour for taking out of unserviceable LT cable XLPE, aluminium armoured type size 35 Sqmm, 3.5 core complete all as directed. Complete all as specified and as directed.
Supply & Fixing of steel tubes light grade galvanized 100 mm bore ISI marked with all fittings fixed to walls/ floors/ road crossing, poles as required. Complete all as specified and as directed.
Material & Labour for Labour & tools for horizontal boring through road/ path/ floor for passing UG cables by using trenchless technology as per codes of practice of trenchless technology suitable to geographical condition and using HDD machine with walk over locating system/ wire line locating system/ gyro based locating system for laying upto 100 mm dia GI pipe. Complete all as specified and as directed. Note : GI pipe will be measured and paid seperately.
Tacon Infrastructure Pvt. Ltd.
ALBA AC AND REF SERVICES
Satish kumar and company
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .