Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.0 LAccepted-AOC V P O TEHSIL JAWALAMUKHI DISTT KANGARA HP | L1 | Accepted-AOC accept | |
| 2 | L2₹16.1 L+₹13,500 (0.85%)Rejected-AOC 0 MATADIN KAKRAHI KAKRAHI BHARTHANA ETAWA ETAWAH UTTAR PRADESH 206242 | ETAWAH | UTTAR PRADESH | 206242 | L2 | Rejected-AOC accept | |
| 3 | L3₹16.2 L+₹22,500 (1.41%)Rejected-AOC | L3 | Rejected-AOC accept |
Tender Value
₹12.5 L
EMD Value
₹25,029
Closing Date
18 Dec 2020, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer JSV Division Thural
O/O The Executive Engineer JSV Division Thural
Providing LWSS to SC habitation Saloh,Bhatton, Raipur,Nanoun ,Sullah Thamba in Tehsil Palampur Distt Kangra. H.P.
2020_HPIPH_43178_1
THL-KNG05-729 (14716-765 dated 11.12.2020))
Open Tender
Civil Works - Water Works
Lump-sum
365 days
Providing LWSS to SC habitation Saloh, Bhatton, Ra
Please refer Tender documents.
10 documents required · 10 mandatory
₹400
₹25,029
Yes
12 Apr 2021
11 Dec 2020
19 Dec 2020
11 Dec 2020
18 Dec 2020
11 Dec 2020
120 days
Amount
Design and construction of RCC in M-25 design mix circular over head storag tanks of various capacity 10.00 mtrs staging height at different node/ location of the schemes including site development cost of excavation in all kind of soil cost of construction material necessary arrangement of inlet ,outlet ,over flow & scour pipe along with sluice valve chamber box & other fixtures & fitting including cost of pipe & Aluminum added (The design and drawing shall be got approved from competent authority before execution)
Construction of RCC over head tank with 10 mtrs staging height of 45000 litres capacity at node No1
Note:-The work shall be carried out as per Techanical . Specifcation attached in the NIT &direction of the Engineer-in-charge.All the surrounding shall be levelled & made good & brought in proper shape as per direction of Engineer in charge RCC structure shall be designed IS 456-2000,IS 3370 IS 1893 & other relevent IS code (b) Providing laying and jointing of inlet ,out let,scour and over flow MSERW pipe 4.8 mm wall thickness conforming to IS /IOS 3183 or GI pipe (MC) conforming t o IS 1239( latest )dully flanged (Table-5 ) of appropriate diametre (refer chpter-1)complete with all necessary fitting such as Tees,Bends,Tail pieces,Flanges & valves etc subject to approved of the Engineer in charge.There shall be a by pass arrangement,flute type connection arrangement of outlet pipe with distribution main & over flow pipe connection with any suitable destribution /delivery pipe and all the pipes emanating from the tank shall be painted with appropriate coloures as per directon of the Engineer in charge (c) Providing and fixing of cast iron manhole cover conforming to IS 1726-1991 with upto date ammendments,minimum two numbers of 500 mm internal dia including frame of midium duty (d) Cast iron ventilating pipe with cowl and mosquito prov cover of sufficient length suitable for overhead tank as per standerd Engineering subject to approval of the Engineer in charge (e)All other required accessrioes/aplliances such as lighting cundutor of approved specification ,bell mouth ,control valves (for inlet,outlet & scour arrangement )of cast iron (class PN 1.6) and water level guard (indicator )etc,Which shall be provided (f) Suitable RCC sprial stair case 90 cm wide for access upto the top of the Tank for over head tanks and MS ladders 45 cm wide shall be provided inside the reservoir from top of tank to its botom (g) The tank shall b e painted with water proofing cement paints outside complete in all respect (h) There shall be 1 mtr wide gallery all around the cotainer with provision of fnecessary railing for overhead storage tanks.Dia of piping arrangement :- Inlet pipe = 80mm dia G.I. pipe Medium class,Outlet pipe = 80mm dia G.I. pipe Medium class,Scour pipe = Not less than 80mm dia G.I. pipe.
sanjeev kumar
Shashank Jagota Govt. Contractor
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .