| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹49.3 LAccepted-AOC 200 NAVAGAM NAVAGAM TA SAYLA SURENDRA NAGAR GUJARAT 363430 | SURENDRANAGAR | GUJARAT | 363430 | L1 | Accepted-AOC L1 | |
| 2 | L2₹50.7 L+₹95,990 (1.93%)Rejected-Finance | L2 | Rejected-Finance L2 | |
| 3 | L3₹64.3 L+₹14.6 L (29.4%)Rejected-Finance B 39 UPPER GROUND FATEH NAGAR NEW DELHI 110018 | WEST | DELHI | 110018 | L3 | Rejected-Finance L3 | |
| 4 | L4₹66.0 L+₹16.3 L (32.8%)Rejected-Finance 274 210 DAFNALA ROAD SHAHIBAUG AHMEDABAD GUJARAT 380009 | AHMADABAD | GUJARAT | 380009 | L4 | Rejected-Finance L4 | |
| 5 | L5₹66.9 L+₹17.2 L (34.5%)Rejected-Finance | L5 | Rejected-Finance L5 |
Tender Value
₹49.1 L
EMD Value
₹98,140
Closing Date
11 Feb 2023, 6:00 pmClosed
GE (AF) CHILODA
GE (AF) Chiloda, Lekawada Patia, PO CRPF Campus, Gandhinagar (Gujarat)-382042
SPECIAL REPAIR OF UNDERGROUND CABLE, PROVN OF ANTI SUICIDE RODS, POWER SOCKETS AND CONNECTED ITEMS IN MD ACCN AND PROVN OF EMERGENCY BELL ALARM SYSTEM AT HQ SWAC VSN GNR AND PROVN OF SOLAR WATER HEATER AND ELECTRIC WATER HEATER AT AF STN GANDHINAGAR
2023_MES_574405_1
8883/2022-23/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
VSN
As per NIT
7 documents required · 7 mandatory
₹500
GE (AF) CHILODA
₹98,140
Yes
23 Feb 2023
11 Jan 2023
13 Feb 2023
11 Jan 2023
11 Feb 2023
25 Jan 2023
11 Jan 2023 - 24 Jan 2023
Amount
Excavation in trenches not exceeding 1.5m width and not exceeding 1.5 m in depth and getting out in soft/loose soil for taking up/laying cable/pipe etc complete all as specified and directed.
M & L for dry Sand cushioning to underground cable with screened, washed river sand, including punning gently complete all as specified and directed. Note: - Thickness after punning will be measured for payment.
Returning, filling including spreading, leveling watering & well ramming in laying for not exc. 25 cm thick for soft/ loose soil complete all as specified and directed.
Removal of excavated material at a distance not exc 50 mtr and dipositing where directed at a level not exc. 1.5 mtr above the starting point for soft/loose soil complete all as specified and directed.
Labour only for boring under road/drain by manual method for inserting the light grade pipe GI tubing up to 100 mm dia for cable protection complete all as specified and directed by Engineer In Charge.
Labour only for boring under road/drain by manual method for inserting the light grade pipe GI tubing up to 50 mm dia for cable protection complete all as specified and directed by Engineer In Charge.
Taking down / out underground cable of aluminium conductor of any size and core after disconnecting from sheet metal encloser / panel board and taking out from trenches including taking out brick cable cover complete all as specified and directed.
Supply and laying of cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 300 sq mm 3.5 core laid in trenches / duct passing through pipe / duct/roof or fixed on wall including necessary clamp Nut and bolt and connecting and testing complete all as specified and as directed by Engr-in-Charge. Note:- Excavation / earth work will be measured and paid separately.
M&L in trenches in road cross/ floors /wall /ceiling of tube galvanised iron light grade 100 mm dia with all fittings for protection of cable including clamp, nut and bolt complete all as specified and directed by Engr-in-Charge.
Supply and fix in repair ON load change over switch of 320 Amp Capacity with sheet steel enclosure complete all as specified and directed by Eng-In- Charge.
Supply & install, testing & commissioning AMF LT panel box compartmental type for outdoor installation, Lockable fabrication with dimension 1100(H) x 550(W) x 400(D) made by 3.15 mm thick sheet CRCA approved weather proof design framed on angle iron (50mmx50mmx5mm) double door front and rear openable both side opening shutters duly painted two coat with siemens gray color, cable entry with glands, foundation /grouting on & including PCC as per site requirement Rate including for removal and taking out existing old/rusted LT Panel board of any type any size complete all as approved and comprising as under :- (a) Al bus bar 600 Amp - Set of 4 Strips (b) Automatic transfer Switch 400 Amp - 1 Nos (c) MCB SPN DP 16 Amp, - 2 Nos(Outgoing) (d) SPP - 01 Nos (e) Internal wiring 4 Sqmm copper wire (f) indicating Lamp LED type R,Y,B - 3 Nos (g) Voltmeter 0-500 Volt-01 Nos (h) Amperemeter 0-500 Amps-01 Nos (j) Control Relay 2 NO + 2 NC - 01 Nos
Out going :- a) MCCB 4 Pole, current rating 200 Amp, With Thermal Magnetic release, breaking capacity 25 kA at 415V, 50Hz - 04 Nos. b) MCCB 4 Pole, current rating 160 Amp, With Thermal Magnetic release, breaking capacity 25 kA at 415V, 50Hz - 01 Nos. c) Angle iron base frame as reqd size as per above panel, total leg height 600 mm and grouting in side PCC 150 mm legs and made out of ISA5050, 50 x 50 x 6 mm thick angle iron duly painted - 01 No. d) M & L for necessary excavation and as required PCC 1:3:6 (40 mm graded aggregate) Type C2 for foundation of angle iron legs frame work complete - 01 job
Supply & install, testing & commissioning AMF LT panel box compartmental type for outdoor installation, Lockable fabrication with dimension 1100(H) x 550(W) x 400(D) made by 3.15 mm thick sheet CRCA approved weather proof design framed on angle iron (50mmx50mmx5mm) double door front and rear openable both side opening shutters duly painted two coat with siemens gray color, cable entry with glands, foundation /grouting on & including PCC as per site requirement with the following (Location HQ SWAC Alpha Block and AFNET DG):- (a) Al bus bar 400 Amp - Set of 4 Strips (b) Automatic transfer Switch 250 Amp - 1 Nos (c) MCB SPN DP 16 Amp, - 2 Nos(Outgoing) (d) SPP - 01 Nos (e) Internal wiring 4 Sqmm copper wire (f) indicating Lamp LED type R,Y,B - 3 Nos (g) Voltmeter 0-500 Volt-01 Nos (h) Amperemeter 0-500 Amps-01 Nos (j) Control Relay 2 NO + 2 NC - 01 Nos
Supply & install, testing & commissioning AMF LT panel box compartmental type for outdoor installation, Lockable fabrication with dimension 1100(H) x 550(W) x 400(D) made by 3.15 mm thick sheet CRCA approved weather proof design framed on angle iron (50mmx50mmx5mm) double door front and rear openable both side opening shutters duly painted two coat with siemens gray color, cable entry with glands, foundation /grouting on & including PCC as per site requirement with the following (Location HQ SWAC Alpha Block and AFNET DG):- (a) Al bus bar 300 Amp - Set of 4 Strips (b) Automatic transfer Switch 125 Amp - 1 Nos (c) MCB SPN DP 16 Amp, - 2 Nos(Outgoing) (d) SPP - 01 Nos (e) Internal wiring 4 Sqmm copper wire (f) indicating Lamp LED type R,Y,B - 3 Nos (g) Voltmeter 0-500 Volt-01 Nos (h) Amperemeter 0-500 Amps-01 Nos (j) Control Relay 2 NO + 2 NC - 01 Nos
M & L for Earthing complete in repairs with galvanised steel earth electrode 60 cm x 60 cm x 6 mm burried directly in ground vertically to a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below ground level connected to and including galvanised earth lead as eGI strip of 32X6mm dia by means of bolts,nuts, check nuts and washer etc made of galvanised iron and connected to earthing test point all as shown in electrical plate No.3 of SSR Part I 2009 and as specified or indicated and testing on completion including excavation/earth work in any type of strata, PCC (1:3:6) type C1 earthing chamber, precast RCC slab 50 mm thick in reinforced cement concrete (1:2:4) type B1 reinforced with welded steel wire fabric (XPM jali weight not less than 4 Kg/Sqm), cast iron frame, funnel with wire mesh, 40 mm bore medium grade GI watering pipe, lugs, 15 mm bore medium grade GI protection pipe, test point etc. complete all as specified and as directed by Engr-in-Charge. Note :- (i) Item includes the cost of 7.5 metre GI pipe for protection of earth lead. Any addition in length shall be adjusted through deviation order. (ii) necessary excavation wk is included in this item.
Supply and lay burnt brick sub class `B' old size in trenches abouting each other width equal to length of brick etc complete all as specified and directed.
Supply and laying in trenches in road cross / floors 40 mm bore tube galvanished iron light grade with all fittings for protection of cable complete all as specifed and as directed.
Supply and laying XLPE insulated PVC inner sheathed, armoured with galvanised steel strip or wire heavy duty underground cable with aluminium multi stranded conductor 1100 volt grade of size 25 Sqmm 3 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing complete all as specified and as directed. Note:-Excavation, earthwork, will be measured and paid separately under respective items of this Schedule.
Supply and fixing rigid non-metallic PVC conduit heavy duty exclusive of boxes, but inclusive of all tees,bends,elbows,reducers and all fixing accessories of size 20 mm on wall/floor etc complete all as specified and as directed.
Supply and fix 2.5 Sqmm three core PVC insulated, unsheathed multistranded copper conductor flexible cable 1100 volts grade complete all as specified and directed by Engr in Charge.
Supply & fix bell buzzer (6 inch) electric steel type AC 230V complete all as specified and directed by Eng-In-Charge.
S&F Modular bell push 6A,1 Module, complete all as specified and directed by Eng-In-Charge.
S & F white cover plate with frame, 1 module complete all as specified and directed by Eng-In-Charge.
S & F Modular metal flush box , 1 module complete all as specified and directed by Eng-In-Charge.
Supply and fix MCB’s single pole with neutral, 6 to 32 Amps, 230 volts complete all as specifed and directed by Engr-in- charge.
Material & Labour for earthing complete in repairs with galvanized iron earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m deep below normal ground connected to galvanised earth lead wire 4.0 mm by means of bolts nuts check nuts and washer of galvanized steel, watering pipe of 20 mm bore, galvanised iron, medium grade, and 40 mm bore galvanised iron light grade for earth wire protection including all excavation earth work in any type of soil, PCC pit with RCC pit cover charcoal salt, funnel complete all as shown in the electrical plate No 3 of SSR part – I and tested on completion including taking down complete all as specified and directed by Engr-in-Charge.
S&F cable jointing kit heat shrink type for 1100 volts grade cable for straight through joints with jointing material and accessories suitable for LT armoured aluminium conductor cable of size up to 25 Sqmm 3.0 core complete all as specified and directed by Eng-In-Charge.
S & F Cable route indicator for LT Cable made of RCC (size 0.2 mtr x 0.1 mtr x 0.75 mtr ) 1:2:4 type B1 (using 20 mm graded crushed stone aggregate) reinforced with 8 mm dia TMT bars 100 mm c/c horizontally vertically with CI Plate route indicator marked/embossed with HT CABLE sign, voltage & cable size mentioned in bold letters painted with brown paint & back ground with two coats of yellow paint in foundation PCC 1:3:6 type C1 using 20 mm graded crushed stone aggregate of size 0.3 mtr x 0.2 mtr x 0.3 mtr including necessary excavation & earth work removal complete all as specified and directed by Eng-In-Charge. Note:The rates quoted by the tenderer shall be deemed to be inslusive of the cost involved for tracing the route of cable by cable route locator.
Supply & fixing for storage water heater (Geyser) 25 Ltr of capacity verticle mounting type electric driven (single phase), not less than 5 Star rating (BEE) and grouting new suitable size anchor fastner in wall and mounting geyser on anchor fastner and writing MES No on geyser and testing complete all as specified and directed.
Material & Labour for wiring using two single core FRLS PVC insulated, unsheathed stranded copper conductor cable of size 2.5 Sqmm of voltage rating upto and including 1100 Volts drawn in and including PVC casing capping of size not less than 20 mm with standard accessories fixed on walls / ceiling surface along-with one run of FRLS PVC (green colour) insulated, unsheathed, stranded copper conductor of size 2.5 Sqmm as earth continuity conductor complete all as specified directed.
All as per item No 31 here in before but for using 4.0 sqmm
Supplying & fixing for switch socket outlet combination, multipurpose, three pin, 15 Amps & three pin 5 Amps controlled by one switch , flush type, 230 volts AC circuit complete all as specified & directed
Supplying and laying of 20mm dia CPVC pipes ( Hot & cold type) SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling/ trench or laying in floors complete all as specified and directed.
S & F for Bib taps, fancy type cast copper alloy with fancy type crutch or butterfly handle, screwed for 15 mm bore of pipe complete all as specified and directed.
S & F Ball valve (brass inserted) of size for 20mm dia CPVC pipe complete all as specified and directed.
Supply & fixing PVC flexible connection pipe nylon braided hot & cold type 15 mm dia 600 mm long with brass fly nut at both ends complete all as specified and directed.
Supply, install, testing and commissioning of solar water (Evacuated Tube Collector) based on direct transferring of heat of capacity 100 LPD solar water stainless steel tank with mounting structure and electric backup, complete all as specified and directed by Engineer-in-Charge.
M&L for point wiring for modular accessories with modular metal flush box and cover plate with frame of suitable size complete with 1.5 Sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLS cable 1100 volts grade drawn through metallic rigid / PVC heavy duty concealed conduit/ casing capping/open coduit with 1.5 sqmm, single core, PVC insulated but unsheathed multistranded copper conductor FRLS cable 1100 volts grade as earth continuity wire terminated in new modular sunken boxes and modular metal flush box as required size at site incl all connected accessories , box made from not less than 1.6mm GI sheet factory made complete all as specified and directed by Eng-In-Charge for the following. (a) One 3 pin socket out let 5 Amps on the independent board.
All as per item No 39 here in before but with cable of size 2.5 Sq mm PVC insulated on independent board for power plug 15 Amps complete all as specified and directed by Eng-In-Charge.
S&F Modular switch one way 6A,1 Module complete all as specified and directed by Eng-In-Charge.
S&F modular switch one way 16A,1 Module complete all as specified and directed by Eng-In-Charge.
S&F Modular socket 6/10A-2/3 pin combined 2 Module complete all as specified and directed by Eng-In-Charge.
S&F Modular socket 16/15A-2/3 pin combined 2 Module complete all as specified and directed by Eng-In-Charge.
Supply & Fix switch socket combined universal 2 in 1, 6 pin, 5 Amps Box type complete all as specified and directed by Eng-In-Charge.
Supply & Fix switch socket combined universal 2 in 1, 6 pin, 15 Amps Box type complete all as specified and directed by Eng-In-Charge.
M&L for Sub main wiring complete with two run of 6 Sqmm single core, PVC insulated but unsheathed, multistranded copper conductor FRLS 1100 Volts grade cable drawn through in and including non metallic, rigid, PVC heavy duty surface conduit/casing capping (ISI marked) with wall thickness not less than 1.8mm complete with all accessories like bends, tees, junction boxes fixed on wall, ceiling and incl sunken type pressed steel terminal boxes with 3mm thick bakelite white/coloured (as approved) top cover including 6 Sqmm single core PVC insulated but unsheathed multistandard copper conductor FRLS 1100 Volts grade cable as earth continuity wire and connected to earth dolly . Note :- Two run of 6 Sqmm cable incl one run of earth wire and PVC conduit and its accessories shall be measured and paid as one length. complete all as specified and directed by Eng-In-Charge.
M&L sub main wiring complete with PVC insulated cable two run of 04 Sq mm (FRLS) 1100 volts grade with multi stranded copper conductor for drawn through and including PVC casing -capping with accessories incl 4 Sq mm unsheathed multi stranded copper conductor as on earth wire complete all as specified and directed by Eng-In-Charge. Note :- Two runs of 4 sqmm cable with one run of earth continuity cable including PVC casing -capping and its accessories will be measured and paid as one unit
Supply and fixing TPN double door DB 4 way incl civil work copmlete all as directed by Engineer-in-Charge.
Supply and fixing sheet metal enclosure, single phase, double door DB, flush to wall mounting for MCB fitted with 200 Amp rated bus bars and neutral links ( without MCB's) 8 ways SPN complete all as specified and directed by Eng-In-Charge.
All as per item No 50 here in before but but 4 way
Supply and fixing factory made single pole and neutral sheet metal enclosure with a two Pin Socket plug and socket with one single pole MCB 240Volts, 20 Amps, capacity complete all as specified and directed by Eng-In-Charge.
Supply and fixing MCB, TPN 415 volts, 63 Amps capacity complete all as specified and directed by Engineer-in-Charge.
Supply and fixing MCB, SPN 240 volts, 40 Amps capacity complete all as specified and directed by Engineer-in-Charge.
Supply and fixing MCB, SP 240 volts capacity 5 - 32 Amps current rating, 10KA breaking capacity complete all as specified and directed by Engineer-in-Charge.
Taking down ceiling fan any size /sweep from different location in station dismantling and removing fan rod to store and reassembling and refixing the fan at its original location after placing smart fan rod and new fan clamp and rubber grommets ,split pin,shackle spindle ,nut bolts safety pin hanger clamp complete all as specified and directed . Note : - Old MS fan rod to be deposited to MES Store yard.
S&F Smart fan down rod (Anti suicide fan rod) 12" length complete all as specified and directed .
Supply and fix flexible cord of 230 volt grade size 0.5 sqmm two core multi stranded copper conductor cable complete all as specified and directed by Engr in Charge.
Supply and fix 1.5 Sqmm 3 core PVC insulated, unsheathed multistranded copper conductor flexible cable 1100 volts grade complete all as specified and directed by Engr in Charge.
Supply and fix 2.5 Sqmm 3 core PVC insulated, unsheathed multistranded copper conductor flexible cable 1100 volts grade complete all as specified and directed by Engr in Charge.
S&F PVC insulated unsheathed multi stranded copper conductor single core of capacity 1.5 sq mm FRLS cable complete all as specified and directed by Eng-In-Charge.
S&F PVC insulated unsheathed multi stranded copper conductor single core of capacity 2.5 sq mm FRLS cable complete all as specified and directed by Eng-In-Charge.
S&F Casing capping patti of any size up to 50 mm dia including all its tee, bends etc of white/ivory/gray colour complete all as specified and directed by Eng-In-Charge.
TECH SERVE SOLUTIONS
Abhishek Enterprises
ALBA AC AND REF SERVICES
Shree Builders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .