Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance 284 CHAND KUTI OPP SHIV TEMPLE RATANADA JODHPUR RAJ | JODHPUR | JODHPUR | RAJASTHAN | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
₹17.5 L
Closing Date
13 Sept 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
XEN ELECTRIC-II
JDA JODHPUR
ELECTRIC EQUIPMENT MAINTENANCE AND WIRING, LIGHT, MOTOR, BATTERY AND GENERATOR AND AIRCONDITIONER MAINTENANCE, REPAIRING AND NEW INSTALLATION AS PER DEMAND AT BARKATULLAH KHAN STADIUM (ANNUAL CONTRACT)
2021_JDAJO_238786_1
JoDA/Nit-06/Elect-II/2021-22
Open Tender
Electrical and Maintenance Works
Percentage
365 days
jodhpur
Please refer Tender documents.
2 documents required · 2 mandatory
₹500
secretary jda jodhpur500 and mdrisl jaipur 500
Exempted
14 Sept 2021
3 Sept 2021
14 Sept 2021
3 Sept 2021
13 Sept 2021
3 Sept 2021
50 days
Amount
BIDDER SHOULD FILL PER MONTH RATE IN COLUMN 13 FOR SR.NO. 2,3,4 AND 8 AND REST SR.NO. BIDDER FILL PER ITEM RATE.
Repair & maintenance of existing Aqua Guard R.O. system inclusive of all spare parts such as carbon candle, Sediment filter, U.V. Lamp etc. (12 Month)
Repair & maintenance of existing water cooler inclusive of all spare parts such as capallary, strainer filter, compressor cooling coil, thermostat, Running capacitor etc.(12 Month)
Regularly Operation & Maintenance of existing LED lights (20-25 watt, 30-40 watt, 80-90 watt, 110-120 watt and LED Flood light) with replacement of defective accessories as per direction of engineering incharge (12 Month)
Supply of Universal AC Remote Control for Split Air Conditioner with Wall Mount, Universal ac remote is compatible with almost all split air conditioners, Long range, durable, soft rubber keypad, plastic body with lcd display, Equipped with different buttons and controls, the remote lets you adjust setting
Supplying & fixing of 150AH, 12V,Lead acid batteries on buy back basis for replacing the existing old batteries. [The old battery shall be retained by contractor.
Supplying and installation of submersible motor pump sets ISI marked (IS : 8034-1989) of approved make connection suitable for T.W./D.C.B./Open well. The job includes lowering of riser pipe. g.I./H.D.P.E. pipe with rope, calbes, installation of complete fitting and accessories, jointing of electrical cables up to switch board. All labour for testing of submersible pumps set and supply of water to water mains, complete in all re3spect. 150mm diameter Submersible pump shall have following HP Rating, phase, Head, minimum Discharge repectively 20.0 HP, 3-Ø, (64-104) Mtr, (400-167) LPM
Regularly operation & maintenance of electronics pole mounting dusk down photo cell timer, clock type timer, ON-OFF panel 63/100 amp rating Main switch. By required replacement all defective accessories which are bumet. broken and mixxing such as air break, contractor, (L&T/BCH male) 3 Pole MCCB, single pole MCCB, solar plate, electronic/micro controller, copper strip lead wire insulator, hard ware. Upto supply sources. And also regularly maintain log sheet of time ON-OFF and must be intimate to site incharge/engineering incharge & if any type of need from JVVNL immediate to inform related office and any type required help to take them. (12 Months) 1) For 63/100 Amp rating (3 Phase)
Servicing of 380 KVA D.G. Set at Site with all material should be change for service of D.G. Set Like :- 1. K-Oil 50 Ltr. premium 2. Oil Filter DV0.014.11 3. Oil Filter DV0-014.27 4. Fuel Filter DV0.020.03.0.00 5. Air Filter DV8.505.74.0.00 6. Air Filter DV8.505.75.0.00 7. K cool 26 Ltr.
Servicing of 250 KVA D.G. Set at Site with all material should be change for service of D.G. Set Like :- 1. B check Kit 6 CTA 2. Element Air Cleaner-2 Nos. 3. Inhibitor, corrosion 10 Ltr. 4. Battery Pulse Lite 12V 65 AH 5. Valvoline premium blue 7800 plus 1/20 Ltr. 6. Valvoline premium blue 7800 plus 1/10 Ltr. 7. Service charge S-2800
SITC if need to be replaced during/at the time of servicing of 380 KVA D.G.set V belt dv0.0016 (Code 40169320)
SITC if need to be replaced during/at the time of servicing of 380 KVA D.G.set Water pump assy (Code 84133020)
SITC if need to be replaced during/at the time of servicing of 380 KVA D.G.set L.L.O.P. Sensor (Code 85371000)
SITC if need to be replaced during/at the time of servicing of 380 KVA D.G.set Hose for reditors (Code 40169320)
SITC if need to be replaced during/at the time of servicing of 380 KVA D.G.set Hose for air cleaner (Code 40169320)
SITC if need to be replaced during/at the time of servicing of 380 KVA D.G.set H.P. pipe (Code 84099990)
SITC if need to be replaced during/at the time of servicing of 380 KVA D.G.set Rellay 24 volt (Code 85371000)
SITC if need to be replaced during/at the time of servicing of 380 KVA D.G.set R.R. Assy (Code 85371000)
SITC if need to be replaced during/at the time of servicing of 380 KVA D.G.set Magnetic pick up unit (Code 85381010)
SITC if need to be replaced during/at the time of servicing of 380 KVA D.G.set Fuel Pipe (Code 84099990)
SITC if need to be replaced during/at the time of servicing of 380 KVA D.G.set Unit 545 unit (Code 85371000)
SITC if need to be replaced during/at the time of servicing of 380 KVA D.G.set Preline filter cartridge (spin on) (Code 84212300)
Bidder Name
Amount
NIRMAN ELECTRIC STORE(GSTN-08AOIPS5332P1Z8)
GUNGUN ELECTRICALS(GSTN-08BCWPM9476K1ZD)
NIRMAN ELECTRIC STORE
NIRMAN ELECTRIC STORE
stage.html
html • 0.02 MB
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .