Loading…
Loading…
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
30 Sept 2026, 4:00 pmDue tomorrow
Published by the portal on this tender, for queries and grievance redressal.
OPD INSTRUMENTS
9865941
GEM/2026/B/8013091
Two Packet Bid
epidural sets
Mahesana, Gujarat
Item wise evaluation
BOQ
7 documents required · 7 mandatory
3 yrs
₹36 L
₹3 Cr
10%
CDMO, West, Health & Family Welfare Department Gujarat, General Hospital Mehsana,, (Jilla Rogi Kalyan Samiti Genaral Hospital Mehsana)
Exempted
Yes
15 Sept 2026
15 Sept 2026
1 Oct 2026
| Item No | Item Title | Description | Qty | Unit | Consignee | Delivery (days) |
|---|---|---|---|---|---|---|
| 1 | epidural sets | Sterile singleuse Epidural Anaesthesia Set
Intended Use For administration of epidural anaesthesiaanalgesia by qualified medical professionals
Epidural Needle Tuohytype epidural needle 18G approx 8090 mm length
Needle Material Medicalgrade stainless steel corrosion resistant
Needle Tip Smooth atraumatic Tuohy curved tip with clearly visible markings
Needle Hub Transparentcolourcoded hub with secure Luer connection
Epidural Catheter Radiopaque sterile epidural catheter medicalgrade biocompatible material
Catheter Size 20G or equivalent suitable for use through 18G epidural needle
Catheter Length Minimum 90100 cm
Catheter Markings Clearly visible depth markings for accurate placement
Catheter Connector Secure leakresistant Luerlock connector
Bacterial Filter Sterile 02022 micron epidural bacterial filter
LossofResistance Syringe Sterile 510 mL syringe Luerlock type
Injection Syringe Sterile Luerlock syringe as required for catheter primingadministration
Epidural Drape Sterile fenestrated drape
Dressing Sterile transparent adhesive dressing for catheter fixation
Skin Preparation Sterile antiseptic preparationswab where included by manufacturer
Connector Cathetertofilterextension connector with secure locking
Extension Tubing Sterile kinkresistant epidural extension tubing where included
Sterility Sterile and EO sterilized or equivalent validated sterilization method
Single Use Singleuse only shall not be reused or resterilized
Latex Latexfree
Packaging Individual sterile peelopen packaging with lotbatch number manufacturing and expiry dates
Quality Standard Manufactured under an appropriate medicaldevice quality management system preferably ISO 13485
Regulatory Compliance CE marked or applicable regulatory approval as required for the offered device
Shelf Life Minimum 1 years from date of manufacture or as per manufacturer standard
Warranty Manufacturers replacement warranty against manufacturing defects
Country of Origin To be declared by the bidder | 5 | pieces | Saiyad Imranali Akramali 384001,General Hospital Mehsana, Opp ST Bus Station Nr Rajmahel Road, Mehsana 384001 | 15 |
| 2 | spinal sets | Sterile singleuse Spinal Anaesthesia Set
Intended Use For administration of spinalsubarachnoid anaesthesia by qualified medical professionals
Spinal Needle 25G or 26G pencilpointatraumatic type
Needle Length 90120 mm suitable for adult spinal anaesthesia
Needle Material Medicalgrade stainless steel corrosion resistant
Needle Tip Atraumatic pencilpoint tip for reduced risk of postdural puncture headache
Needle Hub Transparent ergonomic hub with secure Luer connection
Introducer Needle Compatible introducer needle supplied with spinal needle
Introducer Size Approximately 20G or manufacturercompatible size
Syringe Sterile Luerlock syringe for drug preparationadministration
Syringe Capacity Minimum 5 mL andor 10 mL as appropriate
Skin Preparation Sterile antiseptic swabpreparation where included
Sterile Drape Sterile fenestrated drape
Dressing Sterile dressinggauze for puncturesite dressing
Sterility Sterile supplied in individual sterile packaging
Sterilization Method EO sterilized or equivalent validated sterilization method
Single Use Singleuse only shall not be reused or resterilized
Latex Latexfree
Packaging Individual peelopen sterile packaging with lotbatch number manufacturing and expiry dates
Quality Standard Manufactured under ISO 13485 quality management system preferred
Regulatory Compliance CE marked or applicable regulatory approval for the offered medical device
Shelf Life Minimum 1 years from date of manufacture or as per manufacturer standard
Warranty Manufacturers replacement warranty against manufacturing defects
Country of Origin To be declared by the bidder | 1 | pieces | Saiyad Imranali Akramali 384001,General Hospital Mehsana, Opp ST Bus Station Nr Rajmahel Road, Mehsana 384001 | 15 |
| 3 | close disposable circuit | close disposable circuit | 12 | pieces | Saiyad Imranali Akramali 384001,General Hospital Mehsana, Opp ST Bus Station Nr Rajmahel Road, Mehsana 384001 | 15 |
| 4 | close disposable circuit pediatric | Closed Disposable Pediatric Breathing Circuit
Intended Use Suitable for pediatric patients during mechanical ventilation and anaesthesia
Patient Category Pediatric
Circuit Type ClosedCoaxial breathing circuit with separate inspiratory and expiratory gas pathways
Tubing Type Medicalgrade flexible lightweight and kinkresistant tubing
Tubing Diameter 15 mm or pediatriccompatible size
Circuit Length Minimum 15 m or as required for clinical use
Patient Connection Standard pediatric 15 mm connector
Machine Connection Compatible with standard anaesthesia machineventilator breathing system
Connectors Standard 15 mm22 mm connectors as applicable
Elbow Connector Flexibleswivel elbow connector preferred
Gas Sampling Port Integrated gas sampling port with secure cap
Pressure Monitoring Port Provision for airway pressure monitoring
Reservoir Bag Compatible pediatric reservoir bag minimum 051 L as applicable
WaterCondensate Management Provision for condensate collectiondrainage
HMEHMEF Compatibility Compatible with standard pediatric HMEHMEF filters
Leak Resistance Leakproof construction under normal operating pressure
Material Medicalgrade nontoxic latexfree material
Tubing Transparency Transparent tubing for visual monitoring of condensate and contamination
Dead Space Lowdeadspace design suitable for pediatric patients
Compliance Lowcompliance tubing suitable for pediatric ventilation
Sterility Sterile or supplied as per manufacturers validated intended use
Single Use Singleuse disposable shall not be reused or resterilized
Packaging Individually packedprotectively packed with batchlot number and expiry date
Quality Standard Manufactured under ISO 13485 quality management system
Regulatory Compliance CE marked or applicable regulatory approval for the offered product
Shelf Life Minimum 1 years from date of manufacture or as per manufacturer standard
Warranty Manufacturers replacement warranty against manufacturing defects
Country of Origin To be declared by the bidder | 4 | pieces | Saiyad Imranali Akramali 384001,General Hospital Mehsana, Opp ST Bus Station Nr Rajmahel Road, Mehsana 384001 | 15 |
| 5 | disposable circuit adult | Disposable Adult Breathing Circuit
Intended Use Suitable for adult patients during mechanical ventilation and general anaesthesia
Patient Category Adult
Circuit Type Duallimb disposable breathing circuit with inspiratory and expiratory limbs
Tubing Type Medicalgrade flexible lightweight and kinkresistant tubing
Tubing Diameter 22 mm
Circuit Length Minimum 15 m or as required for clinical use
Patient Connection Standard 22 mm 15 mm patientend connector
Machine Connection Compatible with standard anaesthesia machines and ventilators
Connectors Standard 22 mm connectors with 15 mm patientend compatibility
Elbow Connector Swivelflexible elbow connector preferred
Gas Sampling Port Integrated gas sampling port with secure cap
Pressure Monitoring Port Provision for airway pressure monitoring
Reservoir Bag Compatible adult reservoir bag 2 L or as appropriate
Condensate Management Provision for collectiondrainage of condensate
HMEHMEF Compatibility Compatible with standard adult HMEHMEF filters
Leak Resistance Leakproof construction under normal operating pressure
Material Medicalgrade nontoxic latexfree material
Tubing Transparency Transparent tubing for visual inspection of condensate and contamination
Compliance Suitable for adult mechanical ventilation and anaesthesia applications
Sterility Sterile or supplied according to manufacturers validated intended use
Single Use Singleuse disposable shall not be reused or resterilized
Packaging Individualprotective packaging with batchlot number and expiry date
Quality Standard Manufactured under ISO 13485 quality management system
Regulatory Compliance CE marked or applicable regulatory approval for the offered product
Shelf Life Minimum 1 years from date of manufacture or as per manufacturer standard
Warranty Manufacturers replacement warranty against manufacturing defects
Country of Origin To be declared by the bidder | 20 | pieces | Saiyad Imranali Akramali 384001,General Hospital Mehsana, Opp ST Bus Station Nr Rajmahel Road, Mehsana 384001 | 15 |
| 6 | disposable circuit pedia | Disposable Pediatric Breathing Circuit
Intended Use Suitable for pediatric patients during anaesthesia and mechanical ventilation
Patient Category Pediatric
Circuit Type Duallimb disposable breathing circuit with inspiratory and expiratory limbs
Tubing Diameter 15 mm or pediatriccompatible size
Circuit Length Minimum 15 m
Material Medicalgrade nontoxic latexfree flexible and kinkresistant
Patient Connector Standard 15 mm pediatric connector
Machine Connector Compatible with standard anaesthesia machines and pediatric ventilators
Elbow Connector Swivelflexible elbow connector
Gas Sampling Port Integrated gas sampling port with secure cap
Pressure Monitoring Port Provision for airway pressure monitoring
Reservoir Bag Pediatric reservoir bag approximately 051 L
HMEHMEF Compatibility Compatible with standard pediatric HMEHMEF filters
Dead Space Lowdeadspace design suitable for pediatric patients
Compliance Lowcompliance tubing suitable for pediatric ventilation
Condensate Management Provision for condensate collectiondrainage
Tubing Transparent tubing for visual inspection of condensate
Leak Resistance Leakproof construction under normal operating conditions
Sterility Sterile or supplied according to manufacturers validated intended use
Single Use Singleuse disposable shall not be reused or resterilized
Packaging Individually packedprotectively packed with batchlot number and expiry date
Quality Standard Manufactured under ISO 13485 quality management system
Regulatory Compliance CE marked or applicable regulatory approval
Shelf Life Minimum 1 years from date of manufacture or as per manufacturer standard
Warranty Manufacturers replacement warranty against manufacturing defects
Country of Origin To be declared by the bidder | 10 | pieces | Saiyad Imranali Akramali 384001,General Hospital Mehsana, Opp ST Bus Station Nr Rajmahel Road, Mehsana 384001 | 15 |
| 7 | j r circuit | JR JacksonRees Modified Ayres TPiece Breathing Circuit
Intended Use Suitable for pediatric and neonatal anaesthesia and assisted ventilation
Circuit Type JacksonRees Modified Ayres Tpiece system
Patient Category Pediatric Neonatal
Tubing Diameter 15 mm or pediatriccompatible size
Circuit Length Minimum 15 m
Tubing Material Medicalgrade flexible lightweight kinkresistant and latexfree
Patient Connector Standard 15 mm patientend connector
Machine Connection Compatible with standard anaesthesia machines and breathing gas outlets
Reservoir Bag Latexfree collapsible reservoir bag approximately 500 mL capacity
Bag Connector Secure connector compatible with JR circuit
Pressure Monitoring Provision for airway pressure monitoring where applicable
Gas Sampling Port Provision for capnographygas sampling where applicable
Dead Space Low deadspace design suitable for pediatric patients
Resistance Low resistance to gas flow
Transparency Transparent tubing for easy visual inspection
Leak Resistance Leakproof connectors and joints
Sterility Sterile or supplied according to manufacturers validated intended use
Single Use Disposable singleuse shall not be reused or resterilized
Packaging Individual sterileprotective packaging with batchlot number and expiry date
Quality Standard Manufactured under ISO 13485 quality management system
Regulatory Compliance CE marked or applicable regulatory approval
Shelf Life Minimum 1 years from date of manufacture or as per manufacturer standard
Warranty Manufacturers replacement warranty against manufacturing defects
Country of Origin To be declared by the bidder | 4 | pieces | Saiyad Imranali Akramali 384001,General Hospital Mehsana, Opp ST Bus Station Nr Rajmahel Road, Mehsana 384001 | 15 |
| 8 | magils forceps | Magills Intubation Foreign Body Forceps
Intended Use For manipulation of endotracheal tubes removal of foreign bodies and guiding materials during airway procedures
Size Adult approximately 250 mm 10 inch
Material Highquality Stainless Steel surgical grade
Construction Onepiecerobust construction with smooth rounded atraumatic jaws
Jaw Design Angulated jaws suitable for oral and pharyngeal procedures
Jaw Tip Smooth blunt and atraumatic
Handle Ergonomic ringtype handle for secure grip and controlled manipulation
Surface Finish Highquality satinmirror polished finish
Corrosion Resistance Rust and corrosion resistant
Joint Smoothaction joint with accurate jaw alignment
Locking Mechanism No locking mechanism required smooth opening and closing
Sterilization Suitable for repeated sterilization by autoclave
Temperature Resistance Suitable for standard hospital sterilization cycles
Cleaning Easy to clean and compatible with standard enzymatic cleanersdisinfectants
Reusability Reusable surgical instrument
Quality Standard Manufactured under appropriate medicaldevice quality system preferably ISO 13485
Regulatory Compliance CE marked or applicable regulatory approval
Warranty Minimum 1 Year against manufacturing defects
Country of Origin To be declared by the bidder | 4 | pieces | Saiyad Imranali Akramali 384001,General Hospital Mehsana, Opp ST Bus Station Nr Rajmahel Road, Mehsana 384001 | 15 |
| 9 | poratable suction | Portable Electric Medical Suction Apparatus
Intended Use Suitable for suction of blood mucus secretions vomitus and other body fluids in emergency ICU OT labour room ward ambulance and bedside applications
Pump Type Oilfree maintenancefree pistondiaphragm vacuum pump
Maximum Vacuum Minimum 600 mmHg 80 kPa
Air Flow Minimum 20 Lmin
Vacuum Adjustment Continuously adjustable vacuum regulator
Vacuum Gauge Integrated analogdigital vacuum gauge
Collection Jar Minimum 2 1 L autoclavable collection jars or equivalent
Jar Material Transparent impactresistant polycarbonate
Overflow Protection Automatic overflow shutoff system
Bacterial Filter Hydrophobic bacterialviral filter provided
Suction Tubing Medicalgrade flexible kinkresistant siliconePVC tubing
Tubing Length Minimum 15 m
Operation Continuous operation suitable for hospital use
Noise Level 60 dB preferred
Power Supply 220240 V AC 50 Hz
Battery Backup Rechargeable battery backup preferred for emergencyambulance use
Battery Operating Time Minimum 30 minutes on battery if batteryoperated model is offered
Charging Automatic battery charging system
Body Highimpact ABSplastic or powdercoated metal housing
Portability Compact construction with integrated carrying handle
Mobility Suitable for tabletopbedside use trolley option if specified
Safety Thermal overload protection and motor protection
Cleaning Easy to clean and compatible with standard hospital disinfectants
Quality Standard ISO 13485 Certified Manufacturer preferred
Regulatory Compliance CE marked or applicable regulatory approval
Warranty Minimum 1 Years Comprehensive Warranty
Country of Origin To be declared by the bidder | 4 | pieces | Saiyad Imranali Akramali 384001,General Hospital Mehsana, Opp ST Bus Station Nr Rajmahel Road, Mehsana 384001 | 15 |
| 10 | resuscitation set | Complete Emergency Resuscitation Set
Intended Use For emergency airway management ventilation and cardiopulmonary resuscitation in hospitals emergency rooms ICU OT labour room ambulance and wards
Carrying Case Durable impactresistant washable medicalgrade carrying case with organized compartments
Adult Ambu Bag Selfinflating resuscitator adult size minimum 1600 mL capacity
Pediatric Ambu Bag Selfinflating resuscitator pediatric size approximately 500 mL capacity
Neonatal Ambu Bag Selfinflating resuscitator neonatal size approximately 250 mL capacity
Face Masks Transparent anatomical reusablesterile masks in adult pediatric and neonatal sizes
Oxygen Reservoir Oxygen reservoir bagtubing supplied with resuscitators
Oxygen Tubing Medicalgrade oxygen tubing with standard connectors
Airway Oropharyngeal airways Guedel type in multiple sizes
Nasopharyngeal Airway Suitable sizes for adultpediatric use where included
Laryngoscope LEDFibreoptic laryngoscope with adult and pediatric blades
Laryngoscope Blades MacintoshMiller blades in appropriate sizes
Endotracheal Tubes Cuffed and uncuffed ETTs in assorted adultpediatric sizes
Stylet Compatible ETT stylets in adult and pediatric sizes
Suction Catheters Assorted sizes suitable for airway suction
Yankauer Suction Sterilemedicalgrade Yankauer suction handle with tubing
Magill Forceps Adult andor pediatric Magill forceps
Lubricating Jelly Sterile watersoluble lubricant
TapeFixation Medical adhesive tape for securing airway devices
Oxygen Connection Standard oxygen inlet connector compatible with hospital oxygen supply
Pressure Relief Resuscitator shall include appropriate pressurerelief valve particularly pediatricneonatal units
Construction Medicalgrade latexfree durable and easytoclean components
Sterilization Reusable components shall be autoclavablecompatible with recommended hospital sterilization method
Portability Complete set shall be compact and readily transportable during emergencies | 10 | pieces | Saiyad Imranali Akramali 384001,General Hospital Mehsana, Opp ST Bus Station Nr Rajmahel Road, Mehsana 384001 | 15 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_9865941.pdf
GEM_BID • 0.40 MB
atcthree_2026-09-08-19-09-05_faeabbde5aebc806ba31d52ba447fd54.pdf
BOQ • 3.47 MB
boq_item_sample_file_2026-09-08-19-09-05_6c8e9cd0fc2f1113211dbfd3ae6158a2.csv
BOQ • 0.06 MB
GEM_OTHER • 3.47 MB
gtc.pdf
GEM_OTHER • 0.71 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .