| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.7 LAccepted-AOC PERUMKUNNAPALA HOUSE NELLIPARAMBA KUTTIYERI 670141 | KUTTIYERI | KANNUR | KERALA | 670141 | L1 | Accepted-AOC L1 | |
| 2 | L2₹4.8 L+₹8,237.79 (1.75%)Rejected-Finance MOORKOTH HOUSE MUZHAPPILANGAD PO KANNUR | KANNUR | KANNUR | KERALA | L2 | Rejected-Finance L2 |
Tender Value
₹5.0 L
EMD Value
₹12,470
Closing Date
13 Jul 2020, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EXECUTIVE ENGINEER LSGD KANNUR
EXECUTIVE ENGINEER LSGD KANNUR
Kannur DP Proj. No 40/20-21 KPR Gopalan Smaraka GHSS Maintenance in Kallyasseri GP
2020_LSGD_370184_5
D/TN/1(3)/2020-21
Open Tender
Civil Works - Buildings
Item Rate
180 days
kannur
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,128
Yes
online
₹12,470
Yes
2 Nov 2020
6 Jul 2020
16 Jul 2020
6 Jul 2020
13 Jul 2020
6 Jul 2020
60 days
Amount
School Maintenance.
60.7.1 : DRY RUBBLE MASONRY _ Dry rubble without concrete levelling course masonry with good quality blasted rubble including packing to compactness to lines and levels cost and conveyance of all materials labour charges etc. complete as per direction of Departmental officers at site
5.1.3 : Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
5.9.5 : Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
od753984/2020_2021 : Modified 50.6.7.1 Laterate masonry with neatly dressed laterate stone of size 35x20x20cm or nearest size in cement mortar 1:6 for <br> foundation and basement including all cost of materials, labour charges etc.<br><br>
50.2.25.1 : Filling with contractor's own earth ( excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-charge
4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
15.56 : Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.
13.1.1 : 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
11.37 : Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints with white cement and matching pigment etc., complete.
13.43.1 : Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer
13.60.1 : Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work
50.18.8.3.1 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 25 mm pipe 12 kgf/cm2
50.18.9.18.2 : Providing and fixing PVC pipes including fixing the pipe with clamps/Clips at 1.00 m spacing. This included jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 75 mm dia 4 Kfg/cm2 - External work - Exposed on wall
od757524/2020_2021 : Providing and fixing S.D.B Tap 15mm.<br>
15.31 : Dismantling tiled roofing with battens, boarding etc. complete including stacking of serviceable material and disposal of unserviceable material within 50 metres lead.
15.57 : Dismantling aluminium / Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable surplus material and stacking of serviceable material with in 50 metres lead as directed by Engineer - in-Charge
od755372/2020_2021 : Modified 50.12.4.1 Providing and fixing departmental false ceiling with 7.5mm thick PVC plain panel board ceiling of approved quality in Al frame work with necessary screws etc complete. (Al frame work shall be paid separately.)
50.10.2 : Steel work for purlin/single section with G I pipes including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete
od754091/2020_2021 : <br>Providing Alu Zinc roofing including vertical curved<br>surface fixed with polymer coated J or L hooks, bolts and nuts<br>8mm diameter with bitumen and GI limpet washer or with GI limpet <br>washers filled with white lead, including a coat of approved steel primer,<br>and two coats of approved paint on overlapping of sheet complete,<br>(upto any pitch in horizontal/vertical or curved, surfaces), <br>excluding the cost of purlins, rafters and trusses and including, <br>cutting to size and shape wherever required. 0.40mm Alu-Zinc sheet.
od754166/2020_2021 : :Providing and fixing Alu zinc sheet 0.40 mm thick using self drilling / self tapping<br>screws complete<br>Ridges plain (500-600 mm)
od754676/2020_2021 : Providing and fixing 150 mm split pipe over flat iron brackets 20x5 mm size
50.18.7.6.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing . This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 50 mm dia 6 Kgf/cm2 - Internal work- Exposed on wall
50.18.9.7.1 : Providing and fixing PVC pipes includings of pipes with one step PVC solvent cement, trenching refilling & testing of joints complete as per direction of Engineer in Charge. 63 mm dia 6Kgf/cm2
VINEEP M
Bidder Name
P PRABHAKARAN
VINEEP M
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_524039.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .