Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.7 CrAdmitted-Finance | ₹2.7 Cr | L1 | Admitted-Finance |
| 2 | L2₹2.7 Cr+₹55,621.24 (0.21%)Admitted-Finance | ₹2.7 Cr+₹55,621.24 (0.21%) | L2 | Admitted-Finance |
| 3 | Rejected-Technical | - | - | Rejected-Technical Bid is non responsive |
| 4 | Rejected-Technical 3 7 PADI GALI VIKAS NAGAR DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | - | - | Rejected-Technical Bid is non responsive |
| Sl No | Description | Qty | Unit | sushilprasad L1 | M/S AJAY CHAUDHARY L2 |
|---|---|---|---|---|---|
| 1.00 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. For thickness of tiles above 25 mm and up to 40 mm | 1,360 | Sqm | 77.88 ₹1,05,916.8 Lowest | 90 ₹1,22,400 |
| 2.00 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. | 6 | Cum | 1,335.85 ₹8,015.1 Lowest | 1,500 ₹9,000 |
| 3.00 | Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : | 46 | No. | 127.86 ₹5,881.56 Lowest | 130 ₹5,980 |
| 4.00 | Treatment of soil under floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor : With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration | 1,360 | sqm | 206.34 ₹2,80,622.4 | 200 ₹2,72,000 Lowest |
| 5.00 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size). | 291 | cum | 5,261.6 ₹15,31,125.6 Lowest | 5,500 ₹16,00,500 |
| 6.00RENFORCED CEMENT CONCRETE WORK | |||||
| 7.00Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.“(Note :- Cement content considered in this item is @ 330 kg/cum.“Excess/ less cement used as per design mix is payable/recoverable separately). | |||||
| 8.00 | Work above to plinth level upto floor V level | 144.06 | Cum | 8,543.51 ₹12,30,778.05 | 8,500 ₹12,24,510 Lowest |
| 9.00Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. | |||||
| 10.00 | Above Plinth | 169.76 | qtl | 7,588.49 ₹12,88,222.06 Lowest | 7,800 ₹13,24,128 |
Tender Value
Refer Docs
EMD Value
₹5.3 L
Closing Date
10 Dec 2020, 3:00 pmClosed
PROJECT MANAGER BRIDCUL
BRIDCUL, AWASTHAPNA BHAWAN OPP GOVT ITI NIRANJANPUR DEHRADUN
Renovation work for Hemwati Nandan Bahuguna Medical University Dehradun, Uttarakhand
2020_BRID3_27678_1
1026/BRIDCUL/233/2020 DATED 12.11.2020
Open Tender
Civil Works - Buildings
Item Rate
180 days
dehradun
Please refer Tender documents.
3 documents required · 3 mandatory
₹5,900
PROJECT MANAGER BRIDCUL DEHRADUN
₹5.3 L
BRIDCUL DEHRADUN
15 Dec 2020
23 Nov 2020
10 Dec 2020
23 Nov 2020
10 Dec 2020
26 Nov 2020
25 Nov 2020
Amount
Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. For thickness of tiles above 25 mm and up to 40 mm
Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.
Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead :
Treatment of soil under floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor : With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size).
RENFORCED CEMENT CONCRETE WORK
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.“(Note :- Cement content considered in this item is @ 330 kg/cum.“Excess/ less cement used as per design mix is payable/recoverable separately).
Work above to plinth level upto floor V level
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete.
Above Plinth
Centring and shuttering for Columns, Pillars, Piers, Abutments, Posts and Struts
Centring and shuttering for Lintels, beams, plinth beams, girders, bressumers and cantilevers
Centring and Shuttering for Suspended floors, roofs, landings, balconies and access platform
Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured). 5.11.1 Suspended floors, roofs, landing, beams and balconies (Plan area to be measured)
MASONRY & PLASTER WORK
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand)
Half brick masonry with F.P.S. bricks of class designation 75 in superstructure 1:4 (1 cement : 4 coarse sand)
Extra for providing and placing in position 2 Nos. 6mm dia. M.S. sq.m bars at every third course of half brick masonry (with F.P.S. bricks).
12 mm cement plaster of mix 1:6 (1 cement : 6 fine sand)
15 mm cement plaster on rough side of single or half brick wall of mix 1: 6 (1 cement: 6 fine sand)
6 mm cement plaster of mix 1:3 (1 cement: 3 fine sand)
FLOORING
Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints with white cement and matching pigments etc., complete.
Providing and fixing Ist quality ceramic glazed wall tiles conforming to sq.m IS : 15622 (thickness to be specified by the manufacture ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm
Kota stone slab flooring over 20 mm (average) thick base laid over an jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick
Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.
WOODEN FLOORING 25 mm wooden planking, tongued and grooved in flooring, including fixing with iron screws complete with - Second class teak wood
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade Area of slab upto 0.50 sqm
Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth. White Agaria Marble Stone
DOOR & WINDOW WORK
Providing and Fixing factory made uPVC door frame, made of uPVC exturded sections , of size 65 mm x 55 mm with wall thickness 2.0 mm (± 0.2 mm), corners of the door frame to be mitred cut and jointed with plastic brackets and stainless steel screws, reinforcing hinge side vertical of the frames with PVC profile of Size 28 mm x 30 mm having wall thickness 2 mm (±0.2 mm), including providing & fixing 3 nos of 125 mm long stainless steel hinges to the frame, fixing the frame with jamb with required number & size of anchor dash fastners, all complete as per manufacturer's specification and direction of Engineer-in-charge.
Providing and fixing 37 mm thick factory made PVC Door shutter, styles and rails made of PVC hollow extruded printed and laminated section having overall dimension 115 mm x 37 mm with wall thickness 2 mm (± 0.2 mm) with inbuilt beading on one side, the styles and rails mitred cut and joint at corners by inserting 2 nos PVC profile reinforcement of size 75 mm x 200 mm long with cross section size of 28 mm x 30 mm having wall thickness 2 mm (± 0.2 mm). Styles, rails and reinforcements to be fusion welded together. Only hinge side vertical style to be reinforced with PVC profile reinforcement in full length. Printed and laminated PVC lock rail of size 110 mm x 37 mm having wall thickness 2 mm (± 0.2 mm) to be welded horizontally with the vertical styles after inserting PVC profile reinforcement as in styles and rails, providing with PVC snap fit beading, panels of 100 x 20 mm printed & laminated and inserting 2 nos 6 mm dia bright steel rod horizontally with both side threaded and tightened with check nuts and washers complete, all as per manufacturer's specification and direction of engineer-in-charge.
Casement window single panel with S.S. friction hinges (300 x 19 x 1.9 mm), made of (small series) frame 47 x 50 mm & sash 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glass pane glazing bead of appropriate dimension. (Area of window upto 0.75 sqm.)
Casement window double panels with top fixed with S.S. friction hinges (350 x 19 x 1.9 mm) made of (small series) frame 47 x 50 mm, sash 47 x 68 mm & mullion 47 x 68 mm all having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area of window upto 2.50 sqm).
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :
Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double action hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-incharge (Door handle, lock and stopper etc.to be paid separately).
Door Fittings (Aluminium)
Providing and fixing aluminium handles ISI marked anodised (anodic coating not less than grade AC 10 as per IS 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : (125mm)
Same as above but 75mm
Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete (200X10mm)
Same as above but (150X10mm)
Same as above but (100X10mm)
Providing and fixing aluminium sliding door bolts, ISI marked anodised anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 300x16 mm
Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles with necessary screws etc. complete (best make of approved quality).
Providing and fixing ISI marked aluminium butt hinges anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary or shade with necessary screws etc. complete: Same as above but 100x75x4 mm
Same as above but 75x63x4 mm
Providing and fixing aluminium casement stays, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.
Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc.
Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.
Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge. With brass cover plate minimum 1.25 mm thickness
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):
Providing and fixing fly proof galvanized M.S. wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm all complete. With 12 mm mild steel U beading
M.S. & STEEL WORK
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding
Steel work welded in built up section/framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, kilogram gates and similar works.
FININSHING & PAINTING WORK
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade New work (two or more coats) over and including priming coat with cement primer
Distempering with 1st quality acrylic distember (Ready mix) having VOC content less than 50 grams/ litre of approved brand and manufacture to give an even shade :Old work (one or more coats)
Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture.
ROOFING WORK
Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per sqm including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24 mm of all Tsections shall be pre-painted with polyster baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in Charge.
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 110 mm diameter
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories Bend 87.5° 110 mm bend
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories 110 mm Shoe (Plain)
PANELING WORK
Providing and fixing specified wood frame work consisting of battens 50x25 mm fixed with rawl plug and drilling necessary holes for rawl plug etc. including priming coat complete. Kiln seasoned and chemically treated hollock wood
Providing and fixing 2nd class teak wood plain lining tongued and grooved on and including wooden plugs complete with necessary screws and priming coat on unexposed surface 12 mm thick
Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete. 2nd class teak wood 50 x 20 mm
French spirit polishing : Two or more coats on new works including a coat of wood filler
sanitary and water supply
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, including cutting and making good the walls etc. Iinternal work - Concealed pipe with anti corrosive bitumastic paint, cutting chases and making good the wall
15 mm dia. nominal bore
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. (external work)
20 mm dia. nominal bore
25 mm dia. nominal bore
Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 15 mm nominal bore
Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15mm nominal bore
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 15 mm nominal bore
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. Flexible pipe 32mm dia
Providing and fixing uplasticised PVC connection pipe with brass unions 45 cm length 15 mm nominal bore
Providing and fixing ball valve (brass) of approved quality complete High or low pressure with plastic floats 20 mm nominal bore
Providing and fixing brass stop cock of approved quality 20 mm nominal bore
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) 25 mm nominal bore
Providing and fixing white vitreous china pedestal type water = closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid
Providing and fixing toilet paper holder :C.P. brass
Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100mm White Vitreous china Orissa pattern W.C. pan of size 580x440mm with integral type each foot rests
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps,32 White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass each pillar tap
Providing and fixing kitchen sink with C.I. brackets, C.P. brass chain with rubber White glazed fire clay kitchen sink of size 600x450x250 mm
Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required : Single half stall urinal with 5 litre P.V.C. automatic flushing cisternn
Providing and fixing PTMT 15 mm Urinal spreader size 95x69x100 mmwith 1/2" BSP thread and shapes, weighing not less than 60 gms.
Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shades with 6 mm thick hard board backing: of Rectangular shape 453x357 mm
Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank
Providing and fixing M.S. holder-bat clamps of approved design to Sand Cast For 100 mm dia. Pipe
Providing and fixing PTMT towel ring trapezoidal shape 215mm long, 200mm wide with a minimum distances of 37mm from wall face with concealed fittings arrangement of approved quality and colours weighing not less than 80 gms than 106 gms.
Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102 mm, height of 75mm with concealed fitting arrangements weighing not less
Providing and fixing PTMT grating of approved quality and colour. Circular type.
100 mm nominal dia.
125 mm nominal dia with 25 mm waste hole
Providing and fixing trap (75 mm dia)
Providing and fixing trap (110 mm dia)
Providing and fixing PVC Coupler (75 mm dia)
Providing and fixing PVC Coupler (110 mm dia)
Providing and fixing PVC Shoe (Plain) (75 mm dia)
Providing and fixing PVC Shoe (Plain) (110 mm dia)
Providing and fixing PVC plain bend of required degree. ( 75 mm dia)
Providing and fixing PVC plain bend of required degree. ( 110 mm dia)
Providing and fixing PVC Single tee with door required degree access door 75x75x75x110mm
Providing and fixing PVC Single tee with door required degree access door 110x110x100x110mm
Providing and fixing on wall face unplasticised Rigid PVC pipes (75 mm dia)
Providing and fixing on wall face unplasticised Rigid PVC pipes (110mm dia)
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes (110mm dia) For External Work
Provinding & Fixing Bib Cock with wall flange including all materials T & P etc. Complete. Jaquar Make CON - 047KN
Provinding & Fixing long nose bib cock with wall flange including all materials T & P etc. Complete. Jaquar Make CON - 107KN
Provinding & Fixing Piller cock including all materials T & P etc. Complete. Jaquar Make ALI - 85001
Providing and fixing C.P. brass Wall Mixture with Provision for Overhead Shower with 115mm Long Bend Pipe on Upper Side, Connecting Legs & Wall Flanges. Jaquar Make FLR - 5273 UPR
Providing and fixing Central Hole Basin Mixture with popul waste Syatem with 450 mm long Braided Hoses including all materials T & P etc. Complete Jaquar Make FLR - 5169 NB
Providing and fixing Sinkn Mixture with including all materials T & P etc. Complete Jaquar Make CON - 309 KN
Provinding & Fixing Anguler Cock with wall flange including all materials T & P etc. Complete. Jaquar Make CON-059KN
Providing and fixing white European wall hung water closet of size 770X365X635 mm (Jaquar Make CNS-WHT-3535 PPZ) with Softclosed Seat Cover, wall hung Cistern with installation Kit including all materials T & P etc. Complete
Providing and fixing white European water closet pan Couple Closet . of size 720X410X800 mm (Jaquar Make VGS-WHT-81751 P18OUFSM) with Cistern (VGS-WHT-81201), Softclosed Seat Cover & Health Faucet 2 mtr long PVC tube & Wall Hook (ALD-CHR-563) including all materials T & P etc. Complete
Provinding & Fixing White Vitreous China Under Counter basin with including all materials T & P etc. Complete. Jaquar Make Size (195X555X425 mm) Counter top basin (Jaquar Make FLS - WHT - 5701) including all materials T & P etc. Complete..
Provinding & Fixing White Vitreous China basin with Full Padestal including all materials T & P etc. Complete. Jaquar Make Size (210X565X440 mm) Counter top basin (Jaquar Make FLS - WHT - 5801) & Padestal (Jaquar Make FLS - WHT - 5301)
Providing and fixing C.P. brass shower rose with size 105 mm dia (Jaquar Make OHS-1709) including all materials T & P etc. Complete.
Providing and fixing C.P. brass shower Arm with size 20 mm & 450 mm long round Shape single flow with self cleaning function (Jaquar Make SHA CHR 479L450)
Providing and fixing 600mm long towel rail without hanger total length of 600mm, including all materials T & P etc. Complete. (Jaquar Make AKP-35711P)
Providing and fixing towel ring round with Round Flangincluding all materials T & P etc. Complete. (Jaquar Make AKP-35721P)
Providing and fixing toilet paper holder including all materials T & P etc. Complete. (Jaquar Make AHS-1551)
Providing and fixing Soap dish including all materials T & P etc. Complete. (Jaquar Make AHS-1531)
Providing and fixing Glass Self including all materials T & P etc. Complete. (Jaquar Make AKP-35771P)
Development work
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.All kinds of soil
Supplying and stacking at site 63 mm to 45 mm size stone aggregate
Supplying and stacking at site 53 mm to 22.4 mm size stone aggregate
Laying, spreading and compacting stone aggregate of specified sizes to WBM specifications in uniform thickness, hand picking, rolling with 3 wheeled road / vibratory roller 8-10 tonne capacity in stages to proper grade and camber, applying and brooming requisite type of screening / binding material to fill up interstices of coarse aggregate, watering and compacting to the required density .
Providing and laying design mix cement concrete of M-30 grade, in roads/ taxi tracks/ runways, using cement content as per design mix, using coarse sand and graded stone aggregate of 40 mm nominal size in appropriate proportions as per approved & specified design criteria, providing dowel bars with sleeve/ tie bars wherever required, laying at site, spreading and compacting mechanically by using needle and surface vibrators, levelling to required slope/ camber, finishing with required texture, including steel form work with sturdy M.S. channel sections, curing, making provision for contraction/ expansion, construction & longitudinal joints (10 mm wide x 50 mm deep) by groove cutting machine, providing and filling joints with approved joint filler and sealants, complete all as per direction of Engineer-in-charge (Item of joint fillers, sealants, dowel bars with sleeve/ tie bars to be paid separately). Cement concrete prepared with batch mixing machine
septic tank
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size).
Brick work with F.P.S. bricks of class designation 75 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand)
Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement 12 mm cement plaster
Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality 19.19.1 L D- 2.5 Square shape 450 mm internal dimensions
Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey With F.P.S. bricks
Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement With 20x20 mm square bar
landscaping
Trenching in ordinary soil up to a depth of 60cm including removal and stacking of serviceable materials and then disposing of by spreading and neatly levelling with in a lead of 50m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge or/and manure before and after flooding trench with water (excluding cost of imported earth, sludge or manure).
Supplying and stacking of good earth at site including royalty and carriage up to 1 km (earth measured in stacks will be reduced by 20% for payment).
Supplying and stacking sludge at site including royalty and carriage up to 1 km (sludge measured in stacks will be reduced by 8% for payment).
Uprooting weeds from the trenched area after 10 to 15 days of its flooding with water including disposal of uprooted vegetation.
Fine dressing the ground.
Spreading of sludge, dump manure and / or good earth in required thickness as per direction of Officer-in-charge (Cost of sludge, dump manure and / or good earth to be paid separately).
Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge..
Grassing with ‘Doob’ grass including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn free from weeds and fit for mowing including supplying good earth if needed (the good earth shall be paid for separately). In rows 5 cm apart in either direction. In rows 7.5 cm apart in either direction.
Preparation of beds for hedging and shrubbery by excavating cu.m 60cm deep and trenching the excavated base to a further depth of 30cm, refilling the excavated earth after breaking clods and mixing with sludge or manure in the ratio of 8:1 (8 parts of stacked volume of earth after reduction by 20% : one part of stacked volume of sludge or manure after reduction by 8%), flooding with water,filling with earth if necessary, watering and finally fine dressing, leveling etc. including stacking and disposal of materials declared unserviceable and surplus earth by spreading and leveling as directed, within a lead of 50m lift up to 1.5 m complete (cost of sludge, manure or extra earth to be paid for separately).
Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately) Holes 60 cm dia, and 60 cm deep.
Providing and fixing M.S. flat iron tree guard 60 cm dia and 2 m high, above ground consisting 4 nos 25 x 6 mm, 2.25 m long and 8 nos 25 x 3 mm 2 m long verticals M.S. flats, riveted to 3 nos 25 x 6 mm M.S. flat iron rings in two halves, fixing together at site with required six numbers of 8 mm dia. and 30 mm long bolts, including painting two coats with synthetic enamel paint of approved brand and manufacture over a coat of primer. One name plate of 1 mm thick M.S. sheet of size 250x100 mm shall be welded to the tree guard near the middle height and lettered CPWD / PWD/ any other approved name. The tree guard shall be suitably fixed to the ground by embedding four legs of tree guard in pits of suitable dia and to a depth of 25 cm, refilling the pits with soil and ramming, complete in all respect as per satisfaction and direction of Officer-in-charge.
Boundary wall
Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size).
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.“(Note :- Cement content considered in this item is @ 330 kg/cum.“Excess/ less cement used as per design mix is payable/recoverable separately).
Work Up to plinth Level
Work Up to plinth level upto floor V level
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete.
Centring and shuttering for foundations, footings, bases of columns etc. for mass concrete
Centring and shuttering for Columns, Pillars, Piers, Abutments, Posts and Struts
Centring and shuttering for Lintels, beams, plinth beams, girders, bressumers and cantilevers
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand)
12 mm cement plaster of mix 1:6 (1 cement : 6 fine sand)
15 mm cement plaster on rough side of single or half brick wall of mix 1: 6 (1 cement: 6 fine sand)
Finishing walls with Acrylic Smooth exterior paint of required shade New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including base coat of water proofing cement paint applied @ 2.20 kg/ 10 sqm).
Steel work welded in built up section/framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, kilogram gates and similar works.
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade Two or more coats on new work over an under coat of suitable sq.m shade with ordinary paint of approved brand and manufacture.
Electrical Work
Wiring for light point/ fan ponit/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, with modular switch, modular plate, suitable Gl box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group( B)
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. Group( B)
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, 2 way modular switch, modular plate, suitable Gl box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc
Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. Group( B)
Wiring for light/ power plug with 2x4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit alongwith 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required.
2X1.5 sq.mm. + 1X 1.5 sq.mm earth wire
2X2.5 sq.mm. + 1X 2.5 sq.mm earth wire
2X4 sq.mm. + 1X 4 sq.mm earth wire
2X6 sq.mm. + 1X 6 sq.mm earth wire
4 X 4 sq. mm + 2 X 4 sq. mm earth wire
4 X 6 sq. mm + 2 X 6 sq. mm earth wire
4 X 10 sq. mm + 2 X 6 sq. mm earth wire
4 X 16 sq. mm + 2 X 6 sq. mm earth wire
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
3 x 1.5 sq. mm
3 x 2.5 sq. mm
3 x 4 sq. mm
S/L following 2 pair, 0.5 sq mm FRLS PVC insulated copper conductor, unarmoured telephone cable in the existing PVC conduit as required.
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required.
S/L co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing PVC conduit as required.
S/F of following sizes of PVC conduit along with accessories in surface/recess including cuttting the wall and making good the same
S/F suitable size Gl box with modular plate and cover in Front on surface or in recess, including providing and flxing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection, painting etc. as required
S/F suitable size GI box with modular plae and cover in FRLSont on surface or in recess, including providing and flxing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection, painting etc. as required.
S/F call bell/ buzzer suitable for D.C/A.C single phase, 230 volts, complete as required.
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, “C” curve including connections, painting etc. as required.
S/F 5 amps to 32 amps rating, 240 volts, 'C' series, miniature circuit breaker suitable for lighting and other loads Single pole and neutral in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single Pole
Double Pole
Triple pole and neutral
Supplying and fixing following rating, double pole, (single phaseand neutral), 240 V, residual current circuit breaker (RCCB),having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required
Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator
4 way (4+12) , Double door
6 way (4+18) , Double door
8 way (4+24) , Double door
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
12 way , Double door
S/F single pole blanking plate in the existing MCB DB complete etc. as required.
Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
Supplying and fixing PVC batten/ angle holder including connections etc. as required.
S/F following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. as required.
5/6 amps switch
3 pin 5/6 amp socket outlet
Telephone socket outlet
TV antenna socket outlet
Supply and fixing of following size/ modules, GI box along with modular base & cover plate for modular switch/ regulator in recess, including connection as required.
1or 2 module (75mmx 75mm)
Installation, testing & commissioning of pre-wired, fluorescent fitting / compact fluoroscent/LED fitting of all type, complete with all accessories & tubes etc. directly on ceiling / wall, including connection with 1.5 sq.mm. FRLS PVC insulated, copper condutor, single core cable and earthing etc. as required.
Installation, testing & commissioning of ceiling/wall fan including wiring the down rods of standard length ( upto 30 cm) with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as reqd.
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450 mm sweep
Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings)
FIRE ALARM & PA SYSTEM
Supplying, installation, testing & commissioning of heat detector operating at 54ºC/57ºC with rate of rise cum fixed temperature (dual thermistor) type with mounting base complete with all connection etc. as required.
Supplying, installation, testing & commissioning of smoke detector with builtin LED and mounting base complete with all connections etc. as required.
Supplying, installation, testing & commissioning of manual call boxes of MS construction in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. as required.
Supplying, installation, testing & commissioning response indicator on surface/recess MS box having two LEDs metallic over complete with all connections etc. as required
Supplying, installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted in M.S. box (16 SWG) with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete as required.
Supplying, installation, testing & commissioning talk back slave station in surface/recess suitable for operation on simplex mode complete with P.T.T. knob & speaker/microphone enclosed in a M.S.(16 SWG)/ ABS box with break glass in front etc. complete as required.
Supplying, installation, testing & commissioning sector panel suitable for following zones, complete with visual indications for short circuit fault, open circuit fault, fire condition and all other standard facilities as per IS:2189 with mimic diagram for all area/zone covered, complete with all connections, interconnections as required.
Supplying, installation, testing & commissioning of 6 zone, voice alarm controller with USB, MP3 player (including 6 zone button paging station) with seamless integration facility with main fire alarm panel for voice evacuation complete as required .
Supplying, installation, testing & commissioning of 6 inches dia, 2 watts, 70/100 volts ceiling speaker complete as required.
Supplying, installation, testing & commissioning of ceiling/wall mounted loud speaker, 3/1.5 Watt in ABS enclosure complete as required
Supplying, installation, testing & commissioning of digital audio amplifier 75 Watt, 25V rms operating at 240 Volt AC Supply complete as required.
Supplying, installation, testing & commissioning of Voice command keypad 6 zone, with microphone assembly complete as required.
Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required
Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface / recessed steel conduit of following pairs, cores and size including connections and interconnections etc. as required.
speaker cable Two pair, 2-core, 1.5 sqmm
speaker cable Three pair, 2-core, 1.5 sqmm
Supplying and fixing 25 mm dia MS flexible pipe with PVC coating along with all ancillaries and accessories like coupler etc. as required.
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.
EARTHING SYSTEM
Earthing with G.I. earth Plate 600mm x 600mm x 6mm thick including accesssories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal or coke and salt as required.
Providing and fixing 25 mm x 5 mm GI strip in 40 mm dia GI pipe from earth electrode including connection with brass nut , bolt , spring , washer , excavation and re filling etc. as required.
Providing and fixing 25 mm x 5 mm G.I. strip on surface or in recess for connections etc. as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required.
Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required.
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
LAYING OF UNDERGROUND LT & HT CABLES
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required.
Upto 35 sq. mm
Above 95 sq. mm and upto 185 sq. Mm
Supplying & making of end terminations with brass compression gland and Al. lugs for following sizes of PVC insulated and PVC sheathed/ XLPE Al. conductor cable of 1.1 KV grade as required.
3.5 C x 120 sq mm Al Ar. Cable
Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required
50 mm dia
100 mm dia
STREET LIGHT POLE ERECTION
Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required.
Above 4.5 meter and upto 6.5 meter
Providing and laying in position reinforced cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of octagonal poles base. including form work etc. as required (excluding reinforcement) (For LED octagonal Poles)
Supplying and embedding following dia G.I. pipe (medium class) in pole collar/ foundation (during casting) for cable entry including bending the pipe to the required shape complete as required. 32 mm dia (for LED octagonal Poles)
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required
2 x 1.5 sq. mm
Supplying of Linear & compact 9W,4000 K mirror light with decorative grey end caps, polycarbonate body and ribbed opal diffuser Or as approved by the architect as per site condition
Supplying of Surface and wall mounted 20/22 W LED batten, extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser & integrated electronic driver with industrial grade heavy duty driver having THD<10%
Supply of 250 mm sweep non metallic ventilation Exhaust Fan
Supply of 1200 mm sweep ceiling fan , 5 star - BEE star rated
Supply of 10 w LED ball Lamp for mounting on Brass/PVC batton Holder. .
Supplying of Aesthetically designed 2"x2" (600mmx600mm) LED Flat panel which provides soft-light and glare free symmetrical illumination..(34 W , 5700 K )
Supply of Ultra modern, compact surface mounted Aesthetically designed 4"x1" LED Flat panel which provides soft-light and glare free symmetrical illumination SMD LEDs 34W LED 4000K (4x1’). as approved by Engineer in charge complete in all respect.
Supplying of High efficacy 1"x1" (300mmx300mm,) recess LED flat panel with high brightness LED for glare-free homogenous illumination.n.(15 W ,)
Supply,installation, testing & commissioning of IP CAMERA INDOOR 2MP
Supply, installation, testing and commissioning of IP CAMERA OUTDOOR 2MP
Supply, installation, testing and comissioning of Digital Video recorder NVR 8 channel: video mode: NTSC/ PAL, operating system: Embedded Linux, compression: H-264/ G.723 (audio), video input: 16Ch, video output : 16 loop out, 1 BNC, 1 VGA, 1Spot, Recording: 480 fps (NTSC), 400= Fps 240 (PAL), speed recording : 480 dps (NTSC), 400 fps 240 fps (PAL), recording resolution : NTSC-D1(704 X 480), Field (704X 240), CIF(352X240), PAL-D1(704X576), Field D1 (704X288),CIF(352X 288)Live display: 1/4/9/ sequence, LCD display REsolution: SXGA (1280X 1024), TV Display Resoltion: NTSC- SDTV (720 X 480), PAL- SDTV (720 X 576) Recording Mode : Auto, Continuous, Motion. Sensor, Audio : input (4Ch), output (1Ch), TTL (3 Ch), HDD Capacity : Max. 2HDD, Backup: USB 2.0, DVD- RW, Network, Network: ASDL, Cable Modem, Lan (ethernet), power Supply: DC 12V/5A, power consumption: 40W,operating temperature: 5-400 c, weight: 400gms, Dimensions: 430(W)X 86(H)X 270(D)mm.
Supply, installation, testing and comissioning of hard disc 4TB
Supply, installation, testing and comissioning of SWITCH 8 port POE
Supply, installation, testing and comissioning of SMPS
Supply, installation, testing and comissioning of Back Box
Supply, installation, testing and comissioning of 21" LED Monitor for Observation and reviewing
Supply, fixing, testing & commisssioning of Modular RJ-45 with data outlet socket with grid & cover plate in suitable size of 16 SWG GI box. Including crimping of Cat 6 Cables
Supply, installation, testing and commissioning of following Category 6 IDC patch panel prepackaged with wiring block with legs insert labels, label holders, jumper troughs, metal back panel, duct assembly, screws, washers and an instruction sheet for termination of incoming pairs. Quoted price shall include suitable lockable enclosure etc. as required.
48 port jack panel-
24 port jack panel-
Supply & instalation of 9U rack
Supply & instalation of 6U rack-
Supply & instalation of CAT6 UTP patch panel UnLoaded-Copper cables terminating within the floor distributor shall be terminated onto patch panels with RJ45 presentation, by means of an insulation displacement connector. The Patch Panel jacks shall be shuttered to prevent the ingress of dust and other contaminants.
Supply & instalation of Cat6 UTP XL Keystone connector
Supply & instalation of CAT6 UTP PATCH CORD 1M - Rack end- The work area equipment cords shall, at a minimum Comply with ANSI/TIA/EIA-568-C.2 Commercial Building Cabling Standards Transmission Performance Specifications for 4 pair 100 Ohm Category 6 Cabling. Category 6 equipment should be industry standard patch cords: • Shall be round, and consist of eight insulated 24 AWG, stranded copper conductors, arranged in four colour-coded twisted-pairs. • Equipped with modular 8-position modular plugs on both ends, wired straight through with standards compliant wiring. • Should have 50 micro inches of gold plating over nickel contacts. • Modular cords should include a moulded strain relief boot.
Supply & instalation of CAT6 UTP PATCH CORD 2M - User end- The work area equipment cords shall, at a minimum Comply with ANSI/TIA/EIA-568-C.2 Commercial Building Cabling Standards Transmission Performance Specifications for 4 pair 100 Ohm Category 6 Cabling. Category 6 equipment should be industry standard patch cords: • Shall be round, and consist of eight insulated 24 AWG, stranded copper conductors, arranged in four colour-coded twisted-pairs. • Equipped with modular 8-position modular plugs on both ends, wired straight through with standards compliant wiring. • Should have 50 micro inches of gold plating over nickel contacts. • Modular cords should include a moulded strain relief boot.
Supply & instalation of dual Port Face Plate- • Modular Single Gang square (86mm x 86 mm) with 2 ports • Screw hole covers • Should be able to support variety of jacks – UTP, ScTP, FTP etc. • Should facilitate entry for shuttered jacks / information outlets • Two modules or a single module and a blank may be installed in this format. • All outlets shall have facilities for labelling on either the face plate or module. This should be protected by means of clear plastic window.
Supply & instalation of Metal Flush Box - 1/2 module
Supply & instalation of 6 core Indoor/outdoor OM3 Unarmoured Multimode Optical Fiber
Supply & instalation of 24 port fully loaded LIU.
Supply & instalation of optical fiber 3mtr. Patch cord.
Supply, installation, testing and commissioning of following krone type tag blocks enclosed in MS enclosure of suitable size with lockable cover.
50 pair tag box
20 pair Tag block
Supply, laying, testing and commissioning of following size of 0.61mm dia copper conductor multi pair telephone cable as per suitable for indoor telephone wiring conforming for ITD S/WS - 113 C and S/WS - 114 (actual qty. may vary as per site) in existing conduit/ trench/ tray.
20 pair Ar. Cable
10 pair Ar. Cable
Supply & instalation of CAT6 UTP patch panel UnLoaded
Supply & instalation of Cat6 UTP XL Keystone connector
Supply & instalation of CAT6 UTP PATCH CORD 1M
Supply and installation of Digital EPABX system Compatible with Digital PRI and Analogue Trunk Expandable Machine Configuration: 2 Trunk + 2 Digital +46 Extensions.
WITH CALLER ID ON ANALOUGE &
DIGITAL PHONE
** WITH AUTO ATTENDANT
** LEAST COST ROUTING (LCR)
** GLOBAL DIALING
** EXTERNAL CALL FORWARD
** DIRECT INWARD DIALING
** CLASS OF SERVICE
CONFIGURATION :
** 02 TRUNK LINE
** 02 DIGITAL
** 46 ANALOGUE EXTN
In built recordable Music on hold, 100% Digital and non blocking.
Supply and instalation of Digital Key Telephone with KTS console.
Supply and Installation of Telephone Insturment with Caller ID-
Supply and laying of CCTV/ LAN cable in existing conduit
Supply & instalation of Online UPS 10 KVA with 30 mins backup and required SMF Batteries,215 v,
Supply & instalation of Online UPS 25 KVA with 30 mins backup and required SMF Batteries,350v to 460volt input and 400 volt out put
Supply of following sizes of XLPE insulated Aluminum/Copper conductor strip/ wire Armoured, overall PVC sheathed 1.1 KV grade cables conforming to relevant IS code and technical specifications.
3C 2.5 sq mm Cu. Ar. Cable
3.5 C 120 sq mm Al Ar. Cable
Design, Fabrication, Supply, Erection,Testing and commisioning of Powder coated Main Distribution Panel fabricated out of 14 guage CRCA sheet steel in cubical, compartmentallised, free standing floor /wall mounted, dust and vermin proof, with reinforcement of suitable size angle iron, channel, T -iron or flats as required. Cable gland plates shall be provided on top as well as bottom of the panels. Panels shall be treated with all anti-corrosive process before painting as per specification. Panels shall be suitable for 415V, 3-Phase, Four wire, 50 Hz supply complete with earth bus and lifting hooks as required in case of large panels.Approval shall be taken for each panel before fabrication by submiiting the GA drawings to the consultant/engineer in charge . (All hardwares like nuts and bolts used shall be Galvanized and Zinc passivated).
MAIN PANEL
INCOMER
320 A, FP, MCCB ,25 KA for Mains - 1 No.
315 A, FP, Onload Changeover - 1 No.
METERING & INDICATION with each incomer
- ON/OFF phase indicating lamps with control fuses .
Multi Function Meter : measuring of V, A, F, PF, kW, kWh, etc.
BUS BAR-as per SLD
- 400 A, TPN, Al Bus Bars with heat shrinkable PVC Sleeves
OUTGOINGS
- 100A, FP, MCCB, –3 N.o.
- 63A, FP, MCB, –6 N.o.
- 32 A, FP, MCB, –3 N.o.
EXTENARL LIGHTING & POLES
Supply,Installation, testing & Commissioning of 70 W LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP Opening seperate driver compartment with IP66 protection and impact resistance of IK07 with 10KV Built-in Surge Protection Device. on 6 mtrs octagonal pole
Supply of 6 mtr galvanised Octagonal Pole with base plate 220 X 220X 12,top 70mm & bottom 130mm made up of 3mm thik suitable for max. wind speed upto 160 Km/hr.
Poles with Single bracket (1000 mm)
Supply & Installation of Street Light panel(Three Phase Upto 6 KW of Load with astronomical timer and 32TP contactor and 40 Amp MCB rating ) (Havells Cat No, IHXTS0306A or equivalent)
Supply,Installation, testing & Commissioning of 160 KVA Silent DG set comprising of Suitable Engine coupled to 415V 160 KVA alternator both mounted on common Base frame with other standard accessories i.e. Fuel tank, Batteries with leads. along with AMF standard panel . (for detailed specification please ref to Technical Specifications for Electrical Works, should be approved by CPCB
Supply,Installation, testing & Commissioning of SERVO STABLIZER ON AN COOLED - VARIAC TYPE) SITC including loading unloading and transport of 160 KVA ONAN Cooled Servo Stabilizer as per specification below Phase : 3 ph input /3 ph output Input Voltage range : 340 V to 460 V / Output Voltage range : 400V +/- 1 Input Frequency : 45 to 55 Hz / Output Frequency : 50 Hz , Cooling: ONAN ,Duty Cycle 100 % ,No Load Loss Less than 1%,Suitability Suitable for 3 phase Unbalanced/Balanced Supply, Unbalanced / Balanced Loads. High & Low Voltage Cutoff System Over Load And Short Circuit Protection Single Phase Prevention System Phase Sequence change protection Earth Fault Protection
Supply of Split Air Conditioning system Cold only 2 TR, 3 Star Rating
Supply of Split Air Conditioning system Cold only 2 TR, 3 Star Rating
Supply of Voltage Stabilizer 150 V-280 V,5 KVA Capacity
Supply of Copper tubing duly insulated in sleev type nitrile insulation (6 mm)
Supply of Outdoor Unit Frame (Wall Mount/ Floor Mount)
Supply of 20/25 mm UPVC drain pipe
Supply of Electrical Wiring 2.5sqmm x 3Core (communication Cable)
Installation, Testing & Commissioning of Split AC Indoor, out door unit and asseceries
Supply and Installation of ABC type fire extingushier 4Kg
Supply and Installation of ABC type fire extingushier 4Kg
M/S AJAY CHAUDHARY
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .