Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.6 LAccepted-AOC HOUSE NO 43 VPO KOT DISTRICT PANCHKULA 134118 | PANCHKULA | PANCHKULA | HARYANA | 134118 | ₹17.6 L | L1 | Accepted-AOC LOA |
| 2 | L2₹18.6 LRejected-Finance H NO 255 SEC 11 PANCHKULA 134109 | PANCHKULA | PANCHKULA | HARYANA | 134109 | ₹18.6 L | L2 | Rejected-Finance Highest |
| 3 | L3₹19.6 LRejected-Finance | ₹19.6 L | L3 | Rejected-Finance Highest |
| 4 | L4₹19.7 LRejected-Finance 2ND FLOOR PLOT NO 338 UDHYOG VIHAR PHASE IV GURUGRAM 122015 HARYANA | GURUGRAM | HARYANA | 122015 | ₹19.7 L | L4 | Rejected-Finance Highest |
| 5 | L5₹20.7 LRejected-Finance S O DALIP SINGH TEJA KHERA DABWALI 125101 | DABWALI | SIRSA | HARYANA | 125101 | ₹20.7 L | L5 | Rejected-Finance Highest |
| Sl No | Description | Qty | Unit | M/S Mohan Lal Gupta L2 | Nardev Singh Contractor L3 | Netromics Engineering Solutions Private Limited L4 | M/S GARG ELECTRICAL L1 | Dekhora Power & Contructions Private Limited L5 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | [20.71.1]Supply, erection, testing of Ceiling fans IS marked (as per IS code 374) with suitable GI pipe complete in all respects complete as per directions of Engineer-in-charge 1. 48" (1200mm) [Through Rate] | 20 | Each | 1,850 ₹37,000 | 1,950 ₹39,000 | 2,018 ₹40,360 | 1,700 ₹34,000 | 2,185 ₹43,700 |
| 2.00 | [20.72]Supplying, errection, testing of Exhaust fan (as per IS code 374) having a capacity of 45 cubic metre per minute complete with suitable G.I sheet ducting in structure confirming to latest IS specifications complete in all respect to satisfaction of Engineer-in-charge. [Through Rate] | 10 | Each | 1,450 ₹14,500 | 1,450 ₹14,500 | 1,319 ₹13,190 | 1,300 ₹13,000 | 1,445 ₹14,450 |
| 3.00 | [23.20]Fixing of LED Tube light/ 2*2 ft square panel fitting directly on wall /ceiling or false ceiling including making connections etc as required [Through Rate] | 270 | Each | 60 ₹16,200 | 70 ₹18,900 | 65 ₹17,550 | 50 ₹13,500 | 95 ₹25,650 |
| 4.00 | [23.22.1.12]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.12. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 300 to 400 amp , 50 KA [Through Rate] | 2 | Each | 20,250 ₹40,500 | 22,000 ₹44,000 | 20,018 ₹40,036 | 18,000 ₹36,000 | 21,535 ₹43,070 |
| 5.00 | [23.22.1.3]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.3. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. TRIPLE POLE MCCB 16 to 100 Amp, 25 KA [Through Rate] | 12 | Each | 4,600 ₹55,200 | 4,600 ₹55,200 | 4,550 ₹54,600 | 4,500 ₹54,000 | 4,795 ₹57,540 |
| 6.00 | [23.22.1.5]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.5. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. TRIPLE POLE MCCB 200 to 250 Amp, 25 KA [Through Rate] | 4 | Each | 8,500 ₹34,000 | 8,550 ₹34,200 | 8,438 ₹33,752 | 8,500 ₹34,000 | 8,875 ₹35,500 |
| 7.00 | [23.22.1.9]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.9. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 6 amp to 100 amp , 25 KA [Through Rate] | 1 | Each | 5,500 ₹5,500 | 6,000 ₹6,000 | 6,013 ₹6,013 | 5,000 ₹5,000 | 6,225 ₹6,225 |
| 8.00 | [23.22.2.1]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 2.1. MCCB Enclosure made of Sheet Steel suitable for mounting MCCB of following ratings MCCB up to 125 A FP [Through Rate] | 1 | Each | 1,800 ₹1,800 | 1,850 ₹1,850 | 1,782 ₹1,782 | 1,500 ₹1,500 | 1,870 ₹1,870 |
| 9.00 | [23.22.5.1]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.1. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Single Pole [Through Rate] | 6 | Each | 140 ₹840 | 150 ₹900 | 144 ₹864 | 120 ₹720 | 165 ₹990 |
| 10.00 | [23.22.5.8]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.8. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 40 amp to 63 amp. MCBs FOUR POLE [Through Rate] | 1 | Each | 1,290 ₹1,290 | 1,240 ₹1,240 | 1,272 ₹1,272 | 1,000 ₹1,000 | 1,225 ₹1,225 |
Tender Value
₹20.1 L
EMD Value
₹40,100
Closing Date
15 Jan 2026, 5:00 pmClosed
NAVEEN RATHEE
ED - Ambala
Construction of Old Age Home (Now Mata Mansa Devi Shrine Yatri Niwas) in Shri Mata Mansa Devi Shrine Board, Complex, Panchkula (E.I, Street Light and LED Fixtures).
2026_HRY_495826_1
2026EC228D84 F2BF 430C BE8E 8F4B7D920005663BAR
Open Tender
Civil Works
150 days
Ambala
Construction of Old Age Home (Now Mata Mansa Devi Shrine Yatri Niwas) in Shri Mata Mansa Devi Shrine Board, Complex, Panchkula (E.I, Street Light and LED Fixtures).
2 documents required · 2 mandatory
₹1,000
₹40,100
Yes
19 Mar 2026
8 Jan 2026
16 Jan 2026
9 Jan 2026
15 Jan 2026
9 Jan 2026
Amount
[20.71.1]Supply, erection, testing of Ceiling fans IS marked (as per IS code 374) with suitable GI pipe complete in all respects complete as per directions of Engineer-in-charge 1. 48" (1200mm) [Through Rate]
[20.72]Supplying, errection, testing of Exhaust fan (as per IS code 374) having a capacity of 45 cubic metre per minute complete with suitable G.I sheet ducting in structure confirming to latest IS specifications complete in all respect to satisfaction of Engineer-in-charge. [Through Rate]
[23.20]Fixing of LED Tube light/ 2*2 ft square panel fitting directly on wall /ceiling or false ceiling including making connections etc as required [Through Rate]
[23.22.1.12]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.12. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 300 to 400 amp , 50 KA [Through Rate]
[23.22.1.3]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.3. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. TRIPLE POLE MCCB 16 to 100 Amp, 25 KA [Through Rate]
[23.22.1.5]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.5. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. TRIPLE POLE MCCB 200 to 250 Amp, 25 KA [Through Rate]
[23.22.1.9]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.9. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 6 amp to 100 amp , 25 KA [Through Rate]
[23.22.2.1]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 2.1. MCCB Enclosure made of Sheet Steel suitable for mounting MCCB of following ratings MCCB up to 125 A FP [Through Rate]
[23.22.5.1]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.1. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Single Pole [Through Rate]
[23.22.5.8]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.8. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 40 amp to 63 amp. MCBs FOUR POLE [Through Rate]
[23.27.2]Supply and erection of Godrej Almirah typeM.S. pedestal made of 50 mm x 50 mm x 6 mm angle iron frame with 3.00 mm thick M.S. sheet covering including shutters with suitable hinges and locking arrangement with Godrej type handle including round bars . The top covering should have downward overhang of 75 mm on all sides of pedestal , having two sets of water proof ventilation holes of suitable size on the sides , at top and bottom , each set containing four Nos. holes to discharge the heat produced by the current . The shutters fixed with rubber gasket of superior quality and of suitable size to make it water proof . The pedestal duly painted both inside and outside with two coats of approved paint and primary coat and its legs are embeded upto the entire depth in 1:2:4 cement concrete block , projected 75 mm all around the pedestal and and 200 mm above the ground level including the cost of all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-in-charge of the work:- 2. M.S. pedestal of size 750 mm wide , 900 mm high , 300 mm deep and bottom totally open , duly embeded in cement concrete block of size 900 mm x 450 mm x 200 mm above ground level , having a base of size 1050 mm x 600 mm x 250 mm below ground level . 0 0 [Through Rate]
[23.4.1.2]COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT (SURFACE/RECESS) 1.2. Wiring for Light/Fan/call bell point with modular type switch/socket and GI box, Modular type face plate etc in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC conduit pipe. Group B [Through Rate]
[23.4.4.2]COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT (SURFACE/RECESS) 4.2. Wiring in PVC conduit system for 3-pin 5amp. Plug point by using 2 no 1.5 sqmm FRLS copper wire and 1 no 1.5 Sqmm FRLS copper wire , including providing 1 no 5/6 Amp 3/5 pin Modular type socket and 1 no 5/6 Amp Modular type switch required GI Box ,modular face plate etc complete as required Group B [Through Rate]
[23.4.5.2]COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT (SURFACE/RECESS) 5.2. Wiring in PVC conduit system for 3-pin 15amp. Plug point by using 2 no 4 sqmm FRLS copper wire and 1 no 4 Sqmm FRLS copper wire for earthling , including providing 1 no 15/16 Amp 3/6 pin Modular socket and 1 no 15/16 Amp Modular switch required GI Box , modular face plate etc complete as required Group B [Through Rate]
[23.5.6.1]COPPER WIRING IN EXISTING PVC/MS CONDUIT PIPE SURFACE/RECESSED FOR ELECTRICAL POINTS 6.1. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. 1 run of Size 1.50 Sqmm(1/1.40mm) [Through Rate]
[23.5.6.3]COPPER WIRING IN EXISTING PVC/MS CONDUIT PIPE SURFACE/RECESSED FOR ELECTRICAL POINTS 6.3. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. 1 run of Size 4 Sqmm(1/2.24mm) [Through Rate]
[23.7.6.2]PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.2. Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 25 mm dia. [Through Rate]
[24.1.1]EARTHING AND LIGHTENING ARRESTOR 1. Earthing with GL earth pipe 4.5 m long and 40 mm dia with masonry enclosures on the top etc. (but without charcoal or coke and salt) as required. [Through Rate]
[24.1.13]EARTHING AND LIGHTENING ARRESTOR 13. Providing and fixing 4.00 mm dia G1. Wire on surface or in recess for loop earthing as required. [Through Rate]
[24.1.2]EARTHING AND LIGHTENING ARRESTOR 2. Extra for using salt and char coal/coke for pipe earth electrode as required. [Through Rate]
[24.13.32]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 32. 25 Sq mm 4 core (Arm.) [Through Rate]
[24.4.8.3]STREET LIGHT 8.3. Supply and erection of Hot Dip Galvanized octagonal pole of 3mm thickness, with base plate including cost of nut and bolts , earthing studs, Integral Cable termination arrangement 5 mm thick Bakelite base plate on suitable welded MS/GI bracket 32 A four way connector 2 no 10 A SP MCB , end cover and all accessories as supplied by the manufacture including Providing RCC foundation of M25 grade (1 Cement:1 Stone aggregate: 2 Coarse sand) i/c excavation, steel reinforcement (Fe 500) @80 kg/cum of concrete contents, concrete cover 50mm, anchor bolts etc. over a bed of PCC 1:5:10 of required dimensions for octagonal poles of various heights as per following specifications complete in all respects and as per directions of Engineer-in-charge 5 Metre Long pole with top dia 65 mm and bottom dia 130mm with base plate of size 250 x 250 x 16 mm [Through Rate]
[24.5.2.3]MISCELLANEOUS ITEMS 2.3. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work. DWC/HDPE pipe 63/50 mm outer dia/inner dia [Through Rate]
S/E of LED Street Light 45 Watt with innovative, aesthetic and robust design with pressure die cast aluminium housing with UV stabilized PC IP diffuser for better light distribution including all labour and petty material required to complete the job in all respect upto the entire satisfaction of Engineer-in-Charge of work. Make as per approved list.
S/E of LED Post Top 20Watt 5700K Aesthetically designed IP65 LED Post Top light luminaire comprises of spun aluminum top cover, aluminum heat sink, frosted polycarbonate diffuser and die cast aluminum mounting base including all labour and petty material required to complete the job in all respect upto the entire satisfaction of Engineer-in-Charge of work. Make as per approved list.
Supply and Erection of 11.1 Volt 46AH Lithium Ion Battery 36 Hr Backup ,Driver , Motion Sensor ON/OFF Button including all labour and petty material required to complete the job in all respect upto the entire satisfaction of Engineer-in-Charge of work. Make as per approved list.
S/I/T/C of 2x2 LED Panel of IP20 recessed LED 600x600mm with minimum 45mm width fitting made of CRCA with PS diffuser. Fixture should have minimum efficiency @system lumen output of 4200 lumens and maximumum system wattage of 36W. Luminaire should have life of 50000 hours @ L70b50 lumen maintaince, CCT upto 6500k( SDCM (5), THD (10% at full load, CRI) 80, PF) 0.95 and an operating voltage range of 140-270 internal surge protection 4kv Lumainre should have SDCM (5) the fixture should comply with the parameters as per IS 10322. Manufacturer shall have in house lab approved by NABL or ministry of science of Govt of India and also should in house facility of manufacturing of driver LM79 and LM80 reports need to be submitted from a NABL/UL accreditted lab to verify above parameters including all petty material and labour required to complete the job in all respect up to the entire satisfaction of Engineer-in Charge of the work.
S/I/T/C of IP20 recessed LED 18/20 Watt aluminium housing downlighter. Lumainire should have life of 50000 hours @ L70b50 lumen maintaince, CCT upto 6500k (SDCM (5), THD (10% at full load, CRI) 80, PF) 0.95and an operating voltage range of 140-270 internal surge protection 4kv. Lumainre should have SDCM (5 the fixture should comply with the parameters as per IS10322. anufacturer shall have in house lab approved by NABL or ministry of science of Govt of India and also should in house facility of manufacturing of driver LM79 and LM80 reports need to be submitted from a NABL/UL accreditted lab to verify above parameters including all petty material and labour required to complete the job in all respect up to the entire satisfaction of Engineer-in Charge of the work.
S/I/T/C of Fancy Wall Light having specifications with IP code - IP20 / Finger protected, Lumen output fixture - 700 Lumens, Bulb technology - LED, Light color - 3000K, Voltage - 220-240 Volts, Energy class included light source - Built in LED, Wattage bulb included 10W - 15W, Class of protection - Class I - Earthed including all petty material and labour required to complete the job in all respect up to the entire satisfaction of Engineer-in Charge of the work. Make as per aprroved list
S/I/T/C of LED Strip light (Warm White) having specification with Rated wattage 60-100 Watt, Rated voltage 12V DC, rated Lumens per meter 960 Lumens, LED Numbers in per meter 240, Strip length 5 meter, Strip width 9.5 ± 2mm and Adopter having Rated wattage 60-100 Watt, Rated voltage 12V DC including all petty material and labour required to complete the job in all respect up to the entire satisfaction of Engineer-in Charge of the work. Make as per approved List
S/I/T/C of 60 Ltr Mini Refrigarator including all petty material and labour required to complete the job in all respect up to the entire satisfaction of Engineer-in Charge of the work. Mini Refrigarator following specifications is as under:- 1) Energy saving. 4 cm insulation and removable magnetic gaskets, mini -fridge ensures lower energy usage and optimal long-term performance. 2) Eco-friendly. Refrigerator runs on R600A refrigerant gas, an eco-friendly and energy-efficient. 3) Operating temperature. Refrigerator temperature range between plus 0°C and plus 10°C, easily adjustable via a manual thermostat. 4) Ambient temperature. For optimal performance, the ambient room temperature should not exceed 25°C. 5) Compact design. Refrigerator measures 43 x 50 x 51 cm (W x D x H) and includes 4 adjustable feet, making it easy to fit into any layout. 6) LED lighting. Iintegrated LED lighting system improves visibility inside the mini fridge. 7) Minimum and Maximum Input Voltage Range (Volts) 240 to 240 Volts 8) Input Voltage Frequency 50Hz Make as per approved List
M/S Mohan Lal Gupta (BID ID -1407130)
Nardev Singh Contractor (BID ID -1406697)
Netromics Engineering Solutions Private Limited (BID ID -1404984)
Dekhora Power & Contructions Private Limited (BID ID -1407356)
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.14 MB
BOQ_574320.xls
BOQ • 0.26 MB
Download all tender documents and submit your bid