Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.2 LAccepted-AOC 43 SABJI MAHAL ORDERLY BAZAR PO BARRACKPORE DIST 24 PARGANAS N KOLKATA 700120 | KOLKATA | 24 PARGANAS N | WEST BENGAL | 700120 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹19.3 L+₹2.6 L (15.7%)Rejected-AOC | L2 | Rejected-AOC High rate | |
| 3 | L3₹20.1 L+₹3.4 L (20.2%)Rejected-AOC GOALAPARA MONIRAMPUR PO BARRACKPORE DIST 24 PARGANAS NORTH KOLKATA 700 120 WB | KOLKATA | 24 PARGANAS NORTH | WEST BENGAL | 700120 | L3 | Rejected-AOC High rate | |
| 4 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification | |
| 5 | Not Admitted-Fee/PreQual/Technical E 140 2010 BKP VILL AMTALLA PO DUMARCHIR DIST PAKUR PIN 814111 JHARKHAND | PAKUR | PAKUR | JHARKHAND | 814111 | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
Refer Docs
EMD Value
₹30,000
Closing Date
5 Mar 2021, 6:00 pmClosed
GE AF Barrackpore
GE AF Barrackpore Post Barrackpore Dist 24 Parganas North Kolkata 700120
AMC FOR FIRE ALARM SYSTEM AT 6 WING, JAFFARPORE AT AF STN BARRACKPORE UNDER GE (AF) BARRACKPORE
2020_MES_364432_4
8241/BKP/AF OF 2020-21
Open Tender
Civil Works
Item Rate
334 days
6 WING AF BARRACKPORE
Please refer tender doucments
5 documents required · 5 mandatory
₹500
GE AF Barrackpore
₹30,000
Yes
4 Aug 2021
20 Feb 2021
8 Mar 2021
20 Feb 2021
5 Mar 2021
21 Feb 2021
Amount
1. Carry out comprehensive maintenance of Fire Alarm System in 6 Wing for Site I & Site II for following Items- (a) Fire & smoke Detection and alarm system along with gas based fire suppression/extinguishing system with connected accessories at Site I & Site II- 02 Nos (b) Intelligent Adressable Microprocessor based fire alarm panel-02 Nos (c) Intelligent Addressable microprocessor smoke detectors -40 Nos (d) Intelligent Addressable Heat with built in fault isolator - 01 No (e) Intelligent Addressable Manual Call point with built in fault isolator - 06 Nos (f) Active intelligent addressable Interface Unit for Gas extinguishing system -06 Nos (g) Fire Alarm Hooter/Beacon with built in fault isolators for indoor -09 Nos (h) Response Indicator, ceiling mounted -14 Nos (j) Active intelligent addressable Interface Unit for AC/AHU tripping with built in fault isolators -02 Nos (k) 67.5 Ltr capacity Main Cylinder filled with 47 Kg fire Suppression system Gas-2 no (l) 67.5 Ltr capacity Main Cylinder filled with 52 Kg fire Suppression system Gas -2 no (m) 100 Ltr capacity Main Cylinder filled with 81 Kg fire Suppression system Gas-6 no (n) 46.5 Ltr capacity Stand by Cylinder filled with 32 Kg fire Suppression system Gas-02 Nos (o) 80 Ltr capacity Stand Cylinder filled with 66 Kg fire Suppression system Gas-02 Nos (p) Main cylinder acecessories -05 Nos (q) Gas discharge Nozzles-14 Nos (r) Sinorix Check Valve -03 Nos (s) Abort Switch- 05 Nos (t) Release Switch -05 Nos (u) Cylinder manifold -01 No (A) MONTHLY INSPECTION AND PREVENTIVE MAINTENANCE -: Contractor shall provide qualified trained authorised service Engineer from Honeywell Fire Systems and technicians to visit at site with material & labour, testing equipment to check /inspection and routine maitenance the following :-(i) To visit & check the operating parameters of the chillers, all saftey and indicating devices and measuring of voltage, amps and all other parameters every month and (ii) Review the previus months operating log records and alarm history (iii) Inspect the unit for any unusaual vibration, noise etc.(iv) Check for a sign of leakage with the system pressure only the rectifying the same. (Leak repair shall be at extra charges).(v) Check the proper functioning of microprocessor and take control test (If required).(vi) Check/calibrate the flow switch for proper functioning (If required). (vii) Check the LP/HP cut out switches and to replace the same, if found defective.(viii) Check the water flow across the cooler/condenser by checking the pressure drop across the shell.(ix) Periodical software up-gradation.(x) Replacement of spares including any type of labour charges as per Sr No-02 (B) QUARTERLY INSPECTION AND PREVENTIVE MAINTENANCE-:(i) Cleaning of Pot Strainers in water circuit.(ii) Checking of safety control and switches/replacement if required.(iii) Calibration of meters and gauges/replacement if required.(iv) Cleaning of contact switches, checking of relays, timer etc. replacement if required (v) Clean/check the electrical panel of the chiller with air blower. (C) HALF YEARELY INSPECTION AND PREVENTIVE MAINTENANCE-:Testing of Fire Alarm system to the full satisfaction of Users. Note- The arrangement of gas and the T&P for testing is the responsibility of contractor.This gas is in addition to the gas for Comprehensive Maintenance. (D) SPECIAL INSEPECTION AND MAINTENANCE-During operation if machine become unserviceable for that Contractor shall provide qualified trained authorised service Engineer and technicians from Honeywell Fire Systems to visit at site with material & labour, testing equipment to check and attend complaints as and when called and rectify the fault within 24 hours of the Fire Alarm system by following all the recommendations and instruction given in the mannual and service instructions for the product including tags and levels affixed to the equipment, and to comply with all other relevant safety regulation and as directed by Engr - in Charge. (E) Following will also be part of maintenance :-(i) Cost all consumable item like grease, cotton vest, Cleaning agent etc shall be included in quoted rate.(ii) Spares required for carry out Monthly, Quarterly, Annual and Special maintenance (iii) Cost of any type Testing equipment / Tools required for carry out Quarterly, Annual, Special maintenance shall be included in quoted rate.(iv) Cost of any type transportation required for carry out Quarterly, Annual, Special maintenance shall be included in quoted rate(v) Cost of any type Visit charges required Service Engineer and technicians for carry out Quarterly, Annual, Special maintenance shall be included in quoted rate.(vi) Cost of any type consultancy charges required for carry out Quarterly, Annual, Special maintenance shall be included in quoted rate.
Supply only the following items of fire& smoke detection and alarm system along with gas based fire suppression/extinguishing system (a) Alarm Add Detector smoke with base EN54S54310-F1-A1+S54319-F11-A1_IC3428 Make;Siemens or equivalent model of Esser/Honeywell
(b) Alarm Add Detector Heat static +ROR with Base EN54S54310-F4-A1+S54319-F11-A1_IC1899 Make;Siemens/ equivalent model of Esser/Honeywell
(c )Alarm Add Module four input/four output 24V DC/ 230V AC EN54_IC1901 Make;Siemens/ equivalent model of Kider/Chemetron
(d) Alarm Add Soundercum Beacon with Base EN54A5Q00023093+A5Q00012741_IC1902 Make;Siemens/ equivalent model of Esser/Honeywell
(e) Alarm Add Response Indicator EN54_IC1903 ceiling mounted complete with all accessories Make Siemens / equivalent model of Esser/Honeywell
(f) Alarm Add Module control output ONE input/ONE output 24V DCEN54S54312-F2-A1_IC1904. Make;Siemens / equivalent model of Esser/Honeywell
(g) Suppression TFC Cylinder with valve 67.5 Ltrs_IC1748 Make;Siemens,Sinorix 1230 or equivalent of Kider/Chemetron
(h) Suppression TF Gas Sinorix 1230_IC2597 Make-Siemens/Sinorix
(i) Suppression TF Master Cylinder Acc Single *Pr.Gauge+Low Pressure Supervisory switch*Electromagnetic Actuator,*Pneumatic Actuator,*Manual Pneumatic Actuator*Flexible Discharge Hose,*Flexible Actuation Hose*Union 7/16 JIC1/8_IC2582 Make;Siemens,Sinorix or equivalent of Kider/Chemetron
(j) Suppression TF Slave Cylinder Acc Comprising below items: *Pr.Gauge+Low Pressure Supervisory switch,*Pneumatic Actuator,*Flexible Discharge Hose,*Flexible Actuation Hose (+1 No.Extra)*Tee*Elbow_IC1329.Make;Siemens,Sinorix or equivalent of Kider/Chemetron
(k) Suppression TF Check Valve_IC1330 Make;Siemens,Sinorix or equivalent of Kider/Chemetron
(l) Suppression TF Nozzles_IC1331 Make;Siemens,Sinorix or equivalent of Kider/Chemetron
(m) Suppression TFCylinder manifold Make;Siemens,Fabricated/Sinorix or equivalent of Kider/Chemetron
(n) Supression TF Cylinder Rack Support_IC2074 Make;Siemens,Fabricated,Sinorix or equivalent of Kider/Chemetron
(o) Alarm Conv Manual Release Switch_IC3491 Make;Siemens,Sinorix or equivalent of Kider/Chemetron
(p) Alarm Conv Manual Abort Switch_IC3492 Make;Siemens,Sinorix or equivalent of Kider/Chemetron
SANKAR TRADERS
JADAV CONSTRUCTION
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .