Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.8 LAdmitted-Finance B 39 UPPER GROUND FATEH NAGAR NEW DELHI 110018 | WEST | DELHI | 110018 | ₹26.8 L | L1 | Admitted-Finance |
| 2 | L2₹27.3 LAdmitted-Finance 274 210 DAFNALA ROAD SHAHIBAUG AHMEDABAD GUJARAT 380009 | AHMADABAD | GUJARAT | 380009 | ₹27.3 L | L2 | Admitted-Finance |
| 3 | L3₹32.6 LAdmitted-Finance | ₹32.6 L | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Abhishek Enterprises L1 | DATTA SURYAKANT CHAUDHARI L3 | ALBA AC AND REF SERVICES L2 |
|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches by man power to avoid any damage on exisying and electric , water , sewer line ,NFS cable and PNG gas lne services for not exceeding 1.5 m wide and not exceeding 1.5 m in depth for Repair of cable by getting out the any type soil, protection cable cover/bricks and sand and kept it in stack for reuse after repair / replacement of cable etc any damage to existing services by contractor labour / man power / contractor shall be responsible to rectify the same without any extra cost . all cost for man and material for repair of existing services is deemed to included in quoted rate it is also noted that existing services shall be rectified immediately to avoid loss to govt ,.complete all as specified. | 585 | CUM | 310 ₹1,81,350 | 280 ₹1,63,800 | 198 ₹1,15,830 |
| 2.00 | Returning, filling in including spreading, levelling, watering and well ramming excavated soil in layers not exceeding 25 cm thick each, back in trenches after cables have been laid and tested,poles, stays , struts have been erected and tested all as specified and directed. | 235 | CUM | 90 ₹21,150 | 50 ₹11,750 | 63 ₹14,805 |
| 3.00 | Removing excavated surplus soil (Soft/hard soil) obtained from excavation to a distance not exceeding 50 mtr and deposting where directed at a level not exceeding 1.5m above the starting point all as specified and directed. | 350 | CUM | 60 ₹21,000 | 50 ₹17,500 | 72 ₹25,200 |
| 4.00 | Supply and laying sand cushioning for cable protection in trenches 8 cm before laying cable and 15 cm deep over the cable all as specified. | 225 | CUM | 950 ₹2,13,750 | 900 ₹2,02,500 | 891 ₹2,00,475 |
| 5.00 | Supplying and laying un-reinforced precast concrete cable cover, class LV, Type 1, flat with peak, size 250mm x 150mm x 40mm complete all as specified and directed. | 1,500 | EACH | 30 ₹45,000 | 28 ₹42,000 | 27 ₹40,500 |
| 6.00 | Labour Only for laying sand cushioning for cable protection in trenches 8 cm before laying cable and 15 cm deep over the cable all as specified. | 5 | CUM | 550 ₹2,750 | 200 ₹1,000 | 250 ₹1,250 |
| 7.00 | Labour Only For Laying Cable Cover/ Old Serviceable Brick Retrived From Ser No. 1 laid flate in trenches as protection to LT cable complete all as specified and as directed. | 4 | PER 1000 NOS | 3,200 ₹12,800 | 1,000 ₹4,000 | 10 ₹40 |
| 8.00 | Material Labour For Laying Brick laid flate in trenches as protection to LT cable complete all as specified and as directed. | 10 | PER 1000 NOS | 7,000 ₹70,000 | 9,000 ₹90,000 | 10 ₹100 |
| 9.00 | Material and labour for Repair/ replacement of LT cable, laying and testing of cable XLPE Insulated , galvanized steel strip or wire armoured,heavy duty LT electric power cables 1100 Volts grade with stranded aluminium conductor of size 3.5 Core x 50 Sqmm complete all as specified and directed. | 200 | RM | 535 ₹1,07,000 | 575 ₹1,15,000 | 483 ₹96,600 |
| 10.00 | Material and labour for Repair/ replacement of LT cable, laying and testing of cable XLPE Insulated , galvanized steel strip or wire armoured,heavy duty LT electric power cables 1100 Volts grade with stranded aluminium conductor of size 3.5 Core x 35 Sqmm complete all as specified and directed. | 200 | RM | 235 ₹47,000 | 432 ₹86,400 | 362 ₹72,400 |
Tender Value
Refer Docs
EMD Value
₹55,000
Closing Date
10 Jun 2026, 6:00 pmClosed
GE ARMY GANDHINAGAR
GE ARMY GANDHINAGAR PO BSF CAMPUS GANDHINAGAR 382045
SPECIAL REPAIR TO LT SERVICE CABLE AND CONTROL SWITCHGEARS OF OTM AND MD ACCN AND REPLACEMENT CONVERSION OF UNSV AIR CONDITIONERS AND DESERT COOLERS AT MIL STN GANDHINAGAR
2026_MES_766926_1
GE(A)/GNR/TOKEN/31 of 2026-27
Open Tender
Electrical and Maintenance Works
180 days
MIL STN GANDHINAGAR
AS PER TENDER DOCUMENTS
6 documents required · 6 mandatory
₹500
GE ARMY GANDHINAGAR
₹55,000
Yes
3 Jul 2026
21 May 2026
17 Jun 2026
21 May 2026
10 Jun 2026
4 Jun 2026
21 May 2026 - 2 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Excavation in trenches by man power to avoid any damage on exisying and electric , water , sewer line ,NFS cable and PNG gas lne services for not exceeding 1.5 m wide and not exceeding 1.5 m in depth for Repair of cable by getting out the any type soil, protection cable cover/bricks and sand and kept it in stack for reuse after repair / replacement of cable etc any damage to existing services by contractor labour / man power / contractor shall be responsible to rectify the same without any extra cost . all cost for man and material for repair of existing services is deemed to included in quoted rate it is also noted that existing services shall be rectified immediately to avoid loss to govt ,.complete all as specified. | 585 | CUM | - | - |
| 2 | Returning, filling in including spreading, levelling, watering and well ramming excavated soil in layers not exceeding 25 cm thick each, back in trenches after cables have been laid and tested,poles, stays , struts have been erected and tested all as specified and directed. | 235 | CUM | - | - |
| 3 | Removing excavated surplus soil (Soft/hard soil) obtained from excavation to a distance not exceeding 50 mtr and deposting where directed at a level not exceeding 1.5m above the starting point all as specified and directed. | 350 | CUM | - | - |
| 4 | Supply and laying sand cushioning for cable protection in trenches 8 cm before laying cable and 15 cm deep over the cable all as specified. | 225 | CUM | - | - |
| 5 | Supplying and laying un-reinforced precast concrete cable cover, class LV, Type 1, flat with peak, size 250mm x 150mm x 40mm complete all as specified and directed. | 1,500 | EACH | - | - |
| 6 | Labour Only for laying sand cushioning for cable protection in trenches 8 cm before laying cable and 15 cm deep over the cable all as specified. | 5 | CUM | - | - |
| 7 | Labour Only For Laying Cable Cover/ Old Serviceable Brick Retrived From Ser No. 1 laid flate in trenches as protection to LT cable complete all as specified and as directed. | 4 | PER 1000 NOS | - | - |
| 8 | Material Labour For Laying Brick laid flate in trenches as protection to LT cable complete all as specified and as directed. | 10 | PER 1000 NOS | - | - |
| 9 | Material and labour for Repair/ replacement of LT cable, laying and testing of cable XLPE Insulated , galvanized steel strip or wire armoured,heavy duty LT electric power cables 1100 Volts grade with stranded aluminium conductor of size 3.5 Core x 50 Sqmm complete all as specified and directed. | 200 | RM | - | - |
| 10 | Material and labour for Repair/ replacement of LT cable, laying and testing of cable XLPE Insulated , galvanized steel strip or wire armoured,heavy duty LT electric power cables 1100 Volts grade with stranded aluminium conductor of size 3.5 Core x 35 Sqmm complete all as specified and directed. | 200 | RM | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.45 MB
BOQ_858905.xls
BOQ • 0.43 MB
TenderDocuments.pdf
Tender Documents • 0.87 MB
Download all tender documents and submit your bid