Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.4 CrAccepted-AOC FLAT NO 304 SN TOWERS JAGANNADHAPURAM JUNCTION AKKAYYAPALEM VISAKHAPATNAM 530 016 | VISAKHAPATANAM | ANDHRA PRADESH | 530016 | ₹6.4 Cr | L1 | Accepted-AOC Accepted being lowest quoted bidder |
| 2 | L2₹6.8 Cr+₹41.0 L (6.43%)Rejected-Finance MIG 1 12 GULLALAPALEM VUDA COLONY SRIHARIPURAM MALKAPURAM POST VISAKHAPATNAM 530 011 | VISAKHAPATNAM | VISAKHAPATNAM | ANDHRA PRADESH | 530011 | ₹6.8 Cr+₹41.0 L (6.43%) | L2 | Rejected-Finance other than lowest quoted bidder |
| 3 | L3₹6.8 Cr+₹42.0 L (6.59%)Rejected-Finance | ₹6.8 Cr+₹42.0 L (6.59%) | L3 | Rejected-Finance other than lowest quoted bidder |
Tender Value
Refer Docs
EMD Value
₹6.7 L
Closing Date
3 Oct 2020, 6:00 pmClosed
CE Navy Visakhapatnam
CE Navy Station Rd Visakhapatnam 530004
PROVISION OF DEFICIENT SINGLE LIVING ACCOMMODATION FOR SAILORS WITH RELATED INFRASTRUCTURE AT INS KARNA BHEEMUNIPATNAM
2020_MES_353757_2
CE(NAVY)/VIZ/TOKEN NO 27 OF 2019-20
Open Tender
Civil Works
Lump-sum
456 days
INS Kalinga Bheemunipatnam
Please refer tender documents
11 documents required · 11 mandatory
₹3,000
GE P NAVY KALINGA
₹6.7 L
12 Nov 2020
12 Sept 2020
5 Oct 2020
12 Sept 2020
3 Oct 2020
18 Sept 2020
Amount
Schedule "A" Part – I to Schedule "A" Part – XV: NOTE: Schedule "A" Part – I to Part – XIII are prepriced by MES. Bidders shall insert their Lumpsum amount in Green coloured field under Column - 6 only
Lumpsum price worked out by the contractor for "BUILDINGS & STRUCTURES", as listed in Schedule "A" Part – I
Lumpsum price worked out by the contractor for "SITE CLEARANCE / AREA DEVELOPMENT/EARTH WORK/EXCAVATION", as listed in Schedule "A" Part – II
Lumpsum price worked out by the contractor for "ROAD /PATH/CULVERT", as listed in Schedule "A" Part – III
Lumpsum price worked out by the contractor for "AREA DRAINAGE", as listed in Schedule "A" Part – IV
Lumpsum price worked out by the contractor for "SEWAGE DISPOSAL", as listed in Schedule "A" Part – V
Lumpsum price worked out by the contractor for "RAIN WATER HARVESTING", as listed in Schedule "A" Part – VI
Lumpsum price worked out by the contractor for "INTERNAL WATER SUPPLY", as listed in Schedule "A" Part – VII
Lumpsum price worked out by the contractor for "INTERNAL ELECTRIFICATION", as listed in Schedule "A" Part – VIII
Lumpsum price worked out by the contractor for "EXTERNAL WATER SUPPLY", as listed in Schedule "A" Part – IX
Lumpsum price worked out by the contractor for "EXTERNAL ELECTRIFICATION", as listed in Schedule "A" Part – X
Lumpsum price worked out by the contractor for "SOLAR WATER HEATER/COOLING APPLIANCES", as listed in Schedule "A" Part – XI
Lumpsum price worked out by the contractor for "LIGHTENING PROTECTION", as listed in Schedule "A" Part – XII
Lumpsum price worked out by the contractor for "RETAINING WALL", as listed in Schedule "A" Part – XIII
Schedule "A" Part - XIV: [Miscellaneous Items] [Road/Path Culvert,Sewage Disposal, Internal Electrification,External Electrification, Solar Water Heater/ Cooling Appliances, External water supply, Lightening Protection, Arboriculture]:
ROAD/PATH CULVERT
M&L for road marking strips, lines, dashes, arrows, letters etc. of 2.5mm thick (reflective type) on new surfaces of road/pavements and the like exc. 10 cm wide with hot thermo plast material @ 5 Kg/Sqm of white or golden yellow, by fully automatic thermoplastic paint applicator machine, fitted with profile shoe, glass beads dispenser, propane tank heaters and profile shoe heater etc. driven by the skilled operator on road surface complete all as per MORTH specifications and complete all as specified.
S&F dual directional reflective cat eye (Road Glow Stud) of impact resistant ABS plastic 100x90x16mm, of ultra violet resistant yellow colour, having micro prismatic/cube corner reflectors suitable for fixing with epoxy/bitumen adhesive as per manufacturer's specification/instructions complete all as specified. Note: Appropriate epoxy adhesive on the road surface shall be provided as per manufactures specifications/ instructions before fixing the cat eye and the same is deemed to be included in the unit rate quoted.
SEWAGE DISPOSAL
M & L for Underground drainage double wall corrugated HDPE pipe 150 mm dia SN4 confirming to IS : 16098(PART II) single socketed in any length laid in trenches or floors etc complete all as specified.
INTERNAL ELECTRIFICATION
Point Wiring complete with 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable, confirming to IS - 694 drawn through and including heavy duty PVC Conduit, 20 mm dia including all accessories concealed in Walls / Roofs / Floors / Ceiling etc. and pressed GI modular box of 2.0 mm thick and suitable size as required at site and suitable for modular brackets for fixing modular switches, fittings, regulators etc concealed in walls, including 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable as earth continuity conductor with colour coding and connecting to Earth Dolly for One Light / Fan Point / Bell Point controlled by One Switch complete all as specified.
Point Wiring complete with 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable, confirming to IS - 694 drawn through and including heavy duty PVC Conduit, 20 mm dia including all accessories concealed in Walls / Roofs / Floors / Ceiling etc. and pressed GI modular box of 2.0 mm thick and suitable size as required at site and suitable for modular brackets for fixing modular switches, fittings, regulators etc concealed in walls, including 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable as earth continuity conductor with colour coding and connecting to Earth Dolly for One 3 Pin Switch Socket Outlet 5 Amps on Independent Board complete all as specified.
Point Wiring complete with 1100 Volts, FRLS Grade, 4.0 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable, confirming to IS - 694 drawn through and including heavy duty PVC Conduit, 20 mm dia including all accessories concealed in Walls / Roofs / Floors / Ceiling etc. and pressed GI modular box of 2.0 mm thick and suitable size as required at site and suitable for modular brackets for fixing switches sockets, etc concealed in walls, including 1100 Volts, FRLS Grade, 4.0 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable as earth continuity conductor with colour coding and connecting to Earth Dolly for One 3/5 pin 15 Amp socket outlet point controlled by one modular switch of 15/16 Amp as directed on independent board
Point Wiring complete with 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable, confirming to IS - 694 drawn through and including heavy duty PVC Conduit, 20 mm dia including all accessories concealed in Walls / Roofs / Floors / Ceiling etc. and prefabricated pressed GI modular box of 2.0 mm thick and suitable size as required at site and suitable cover plate with frame for fixing modular switches, fittings, regulators etc concealed in walls, including 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable as earth continuity conductor with colour coding and connecting to Earth Dolly for One Light Point controlled by Two Nos. of, Two way Switches complete all as specified.
S & F MCB DB double door Single pole and neutral 06 way sheet steel phosperised powder painted with 200 amps rated bus bar 240 Volts neutral link, IP : 43 protection, double door flush mounting type, making good the disturbed area as per existing surface complete all as specified and as directed (Internal Electrification)
S & F LED 3 Watt wall mounted bedside light with complete fitting. Make Philips Model No 48042 complete all as specified and as directed (Internal Electrification)
Point wiring for flame proof fittings with 1.5 sqmm FRLS PVC insulated and unsheathed copper conductor multistranded 1100 volts grade, ISI marking drawn through and including concealed stove enamelled steel metallic conduit and metal steel conduit accessories, medium grade, ISI marking, concealed, including one run of 1.5 sqmm PVC insulated unsheathed copper cable for earth continuity, connected to earth duly complete all as specified and directed for the following :- (a) One light/bell/fan/ Ex/fan point controlled by one switch (Internal Electrification)
Flame proof LED light fitting 1 X 16/20 Watt with tube, 240volts with IP65 protection with complete set, and complete all as specified and directed
Flame proof exhaust fan heavy duty metal encloser of size 300 mm sweep or nearest size and making good the disturbed surface as per existing area complete all as specified and directed
Switch flame proof rotary type with termination box in LM6, upto 16A, single Pole, 240V Complete all as specified and directed
Energy efficient LED light fitting with tube 2 x 19/20 watt or nearest size ,230V surface mounted LED batten type with extruded aluminium/CRCA housing and robust construction with necessary acrylic cover as diffuser complete with mounting bracket etc including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed
S & F Energy efficient LED light fitting with tube minimum 1x 20 watt ,230V surface mounted LED batten type with extruded aluminium/CRCA housing and robust constrution with necessary acrylic cover as diffuser complete with mounting bracket etc including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified. MAKE : Crompton model No. LDL-20-CDL or equivalent model in Bajaj/Philips/Havells.
S & F Energy efficient LED light fitting with tube minimum 1 x 40 watt ,230V for trunking based solution for large open area with high cieling with extruded aluminium/CRCA housing and robust constrution with necessary acrylic cover as diffuser complete with mounting bracket etc including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified. MAKE : Crompton model No. LDL-40-WW or equivalent model in Bajaj/Philips/Havells.
S & F Energy efficient LED ceiling light fitting minimum 09 watt , integral round shape , 230V surface mounted with necessary diffuser complete with mounting bracket etc including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified.MAKE : Crompton model No. LCDE-09-CDL or equivalent model in Bajaj/Philips/Havells
S & F Energy efficient LED light fitting with tube minimum 2x36 watt ,230V ceiling light surface type including connecting up with twin core twisted flexible copper conductor cable with suitable size.( Porch light) complete all as specified.
S & F Energy efficient LED mirror light fitting with luminare minimum 10 watt , 230V surface mounted with necessary diffuser complete with mounting bracket etc including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified.
S&F LED Security light fitting with tube minimum 20W New generation Energy saving &environmental frindly long life versatile pressure die cast aluminium luminiare with mid power LEDs as source and HF electronic driver pre wired with 1.5 Sq mm copper conductor cable upto connector including 2 Mtr long GI Tubing medium grade 32mm dia bend to shape fixing on wall with suitable MS brackets complete all as specified. MAKE : Crompton model No. LST-20-CDL-M or equivalent model in Bajaj/Philips/Havells.
Supply and Fix ceiling fan 1200 mm sweep complete AC single phase 230 Volt 50 HZ ,5 star rated, connecting with flexible cable 3 core copper conductor of size 23/0.0076 of suitable length from ceiling rose to ceiling fan including all hanging arrangement complete all as specified and as directed
S&F Exhaust fan 300 mm sweep or nearest size, plastic body, complete with louvers suitable for operation on 230 V AC, 50 Hz AC supply fixed on wall making opening,fixing and making good the distrubered surfaces etc complete all as spcified.
S&F Exhaust fan heavy duty 380 mm sweep or nearest size, metal body(Heavy duty), complete with louvers suitable for operation on 230 V AC, 50 Hz AC supply fixed on wall making opening,fixing and making good the distrubered surfaces etc complete all as specified.
LT panel made out of CRCA sheet 2.00 mm thick indoor Pedestal type totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of Switcher gear about termination of switch gear, and the nuts/ bolts etc used are to be made of rust proof material incl as per IS: 8623 tinned copper bus bar with insulators suitable for three phase and four wire LT AC, 50 Hz 415 V 200 A capacity complete with powder coating, with synchroscope, voltmeter, frequency meters load sharing relay and other accessories necessary internal electric connection as required and provision of the following:( Main Panel bldg)
Incoming: MCCB 100 Amp 25 kA, 4 Pole, thermal magnetic release, with adjustable type overload protection, short circuit protection, with necessary CTs, meters and cable boxes. Outgoing; (a) MCCB 63 Amp 16 kA, 3 Pole, thermal magnetic release, with adjustable type overload protection, short circuit protection, with necessary CTs, meters and cable boxes. - 4 Nos (for Ground , Ist , IInd floor & one Spare) (b) Intelligent Panel Digital meter to measure voltage, current, frequency, power factor, etc with all connected CTs . (c)LED indicating lamps with colour Red, Yellow, Blue of 02 Sets
S&F Vertical on load MCCB TPN DB 4 way 415V, 50Hz double door, IP 43 protection with 200A rated bus bar for provision as incommer and MCBc for outgoing circuits complete, fill empty with blanks, making good the disturbed area as per existing surface complete all as specified.
Supply and fix Telephone jack with shutter glossy white RJ45 complete all as specified.
M&L for earthing complete with GI earth plate electrode 60cmX60cmX6mm thick, burried directly in ground (earth pit not less than 2.25 metres deep below ground level)with top edge of the plate not less than 1.5 metres below normal groundlevel, connected to GI earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No-3 of SSR Part-I connected to earthing test point all as specified or indicated including excavation and connected earth work in hard/dense soil, PCC 1:3:6 type C-1 as in pit, 20mm dia GI pipe medium grade for watering pipe, 15 mm bore GI medium grade earth lead protection pipe connected upto DBs, and suitable C.I top cover with handle, funnel, strainer,charcoal and testing on completion all as specified and directed. Note- Rate quoted deemed to be include excavation and earth work in any type of soil with PCC type B2 in pad and pit complete all as specified.
Earthing complete with Galvanised steel Earth plate Electrode 600 X 600 x 6 mm thick burried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of plate not less than 1.50m below normal ground level connected to 32 x 6mm thick GI strip [Earth Lead] and GI pipe 50mm, Medium Grade for earthing lead protection to the extent of maximum 7.5m, Earth plate electrode surrounded by 150mm thick packed layers of charcoal and common salt filled in alternate layers, connected to the plate by means of GI Bolts & Nuts complete all as per Electrical Plate No. 3 of SSR Part - I,connected to panel / DB including testing on completion including main earthing, Charcoal, Common Salt, PCC [1:2:4, TYpe B1] Pit with RCC 1:2:4, Type B1 Cover, 50mm thick with 6 Nos, 8mm dia TMT bars in both ways, MS frame made with 40 X 40 X 6 mm Angle Iron, MS funnel with 20mm bore, medium garde GI watering PIpe, wire mesh, earth work excavation, return filling, removal of surplus soil etc. complete all as specified.
SOLAR WATER HEATER/COOLING APPLIANCES
Supply ,install testing and commissioning Refrigerator electric driven (single phase), of capacity 547 litres double door five star rating complete all as specified and as directed .
Voltage stabilizer for automatic operation,single phase naturally air cooled indoor type & designed for input variation between 170 V to 270 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 4 KVA complete all as specified.
Voltage stabilizer for automatic operation,single phase naturally air cooled indoor type & designed for input variation between 170 V to 270 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 2 KVA complete all as specified.
EXTERNAL WATER SUPPLY
Material and Labour for brick masonary of size 900 x 900 x 900 mm valve chamber of the following sizes including necessary excavation, PCC foundation, brick work, Plastering and MS sheet cover of 6mm thick including locking arrangement with two coats of red oxide primer and one coat of synthetic enamel paint of approved colour complete all as specified.
Material and Labour for brick masonary of size 450 x 450 x 450 mm valve chamber of the following sizes including necessary excavation, PCC foundation, brick work, Plastering and MS sheet cover of 6mm thick including locking arrangement with two coats of red oxide primer and one coat of synthetic enamel paint of approved colour complete all as specified.
M & L for cutting existing CI Line 150mm dia bore including insertion of TEE of size 150x150x100mm dia for branch connection with necessary CI specials as required at site including and excavation and earth work complete all as specified.
EXTERNAL ELECTRIC SUPPLY
Supply and fixing LED street light fitting pressure die cast aluminium housing heat resistant tounghned glass IP 65 protection LED street light luminaires complete all as specified and as directed including clamp and necessary nut and bolts of 48 watt, complete all as specified.
Supply and fixing HOT moulded (FRP) junction box for street light pole with locking arrangement with IP 65 protection of size 280 x 200 with 16 Amp 4 Way heavy duty terminal blcok with 6 Amp MCB SP and two number of cable entry gland of standard size with suitable stainless steel bracket to fix with pole complete all as Specified.
ARBORICULTURE
Supply Approved good quality fertile earth suitable for carpet grass including spreading and levelling
Supply, plantation and developing of Korean Carpet Grass including necessary earthwork excavation to a depth of 30cm in any type of soil, removing the roots and vegetation and filling of good earth, cow dung and watering etc. and applying soil pesticide, transplanting of Korean Grass, planting, routing etc. including cost of manuring the soil, pesticides, grass, manure etc. complete all as specified.
Supply only approved vermi compost of best quality (Bag of 50kgs)
Supply only approved manure (cow dung) best quality suitable for arboriculture.
Supply, plantation and developing of Ashoka Plant[height of plant not less than 450 mm above ground level] including preparation of ground upto 300mm deep and of size 600 X 600mm complete all as specified and directed.
Supply, plantation and developing of Gulmohar Plant [height of plant not less than 450 mm above ground level] including preparation of ground upto 300mm deep and of size 600 X 600mm complete all as specified and directed.
Supply, plantation and developing croton hedges [height of plant not less than 300 mm above ground level] including preparation of ground upto 600mm deep complete all as specified and directed.
PHASE – II: SCHEDULE "A" PART – XV: MAINTENANCE OF ARBORICULTURE WORKS EXECUTED UNDER PHASE – I (Ser Nos, 53, 56, 57 & 58) Maintenance of Arboriculture as provided under Serial Item No. 53 & 56 to 58 of BoQ by weeding, hosing, saucer melding once in every 15 days, planting new plants / grass in place of dead plants / grass of same species and height with out any extra cost to the department and as directed complete for the period of maintenance period of 12 Months complete all as specified and as directed. Note: Rate quoted shall be deemed to include for all labour, materials, tools & plants and regular watering, using sprinklers, including supply and spreading / spraying organic manure, chemical fertilisers, pesticides to the required extent complete all as specified.
S A R CONSTRUCTIONS
CIVILEC ENGINEERING WORKS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .