Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.9 LAccepted-Finance | L1 | Accepted-Finance L1 | |
| 2 | L2₹14.5 L+₹58,474.60 (4.21%)Accepted-Finance | L2 | Accepted-Finance L2 | |
| 3 | L3₹18.9 L+₹5.0 L (35.8%)Accepted-Finance 18 19 MUNESWAR PURAM PARA ALAMNAGAR BIHIND ROSE CHILDREN ACADEMIC LUCKNOW UTTAR PRADESH 226017 | LUCKNOW | UTTAR PRADESH | 226017 | L3 | Accepted-Finance L3 |
Tender Value
₹20.4 L
EMD Value
₹21,000
Closing Date
25 Apr 2024, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SE ETC I, Lucknow
Pareshan Bhawan, Vibhuti Khand, Lucknow
work
2024_UPTCL_921957_1
short e-tender 01/2024-25
Open Tender
Electrical Works
Piece-work
30 days
Lucknow
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
A/c No 2408002190005438, IFS PUNB0691100, PNB, Lk
₹21,000
24 May 2024
10 Apr 2024
26 Apr 2024
10 Apr 2024
25 Apr 2024
10 Apr 2024
Amount
SUPPLY:
33 K.V. Isolator Clamp duly made of Aluminium Alloy (LM 6), suitable for 33 K.V. Isolators and Twin ACSR 'Panther' Conductor, complete with HDG Bolts - Nuts - Washers, as per sample.
33 K.V. C.T. Bi-metallic Clamp duly made of Aluminium Alloy (LM 6), suitable for 33 K.V. CTs and Twin ACSR 'Panther' Conductor, complete with HDG Bolts - Nuts - Washers, as per sample.
33 K.V. C.B. Bi-metallic Clamp duly made of Aluminium Alloy (LM 6), suitable for 33 K.V. VCBs and Twin ACSR 'Panther' Conductor, complete with HDG Bolts - Nuts - Washers, as per sample.
P.G. Clamp made of LM - 6 Alloy having suitable for ACSR 'Moose' to 'Panther' Conductor, complete with Bolt - Nut - Washers (4 No. Nut & Bolts), as per sample.
P.G. Clamp made of LM - 6 Alloy having suitable for ACSR 'Panther' to 'Panther' Conductor, complete with Bolt - Nut - Washers (4 No. Nut & Bolts), as per sample.
Bolted type Tension Fitting suitable for ACSR `PANTHER' Conductor without Turn Buckle for 33 K.V. Bus Bar suitable for 70 KN Disc Insulators complete with Hardware Fittings, D-Shackle, I-socket, Ball Hook, Yoke Plate, I-clapit, Tension Clamp etc.
33 K.V. L.A. Clamp duly made of Aluminium Alloy (LM 6), suitable for 33 K.V. LAs and ACSR Twin 'Moose' Conductor, complete with HDG Bolts, Nuts & Washers.
33 K.V. Bus Post Insulator Clamp duly made of Aluminium Alloy (LM 6), suitable for 33 K.V. Post Insulator and ACSR Twin 'Panther' Conductor, complete with HDG Bolts, Nuts & Washers.
SCADA Items
Supply of Armoured Fibre optical cable (6 fibre) suitable for communication between LIU to SAS/SCADA system
Supply of Fibre Optical multimode patch card for ST-MTRJ port (each 3/5 mtr)
Supply of Fibre Optical multimode patch card for LC-LC port (each 10 mtr)
Supply of Fibre Optical multimode patch card for ST-ST port (each 10 mtr)
Following works are to be carried out at 132 KV S/S Jehta Lucknow for the construction of 33 KV 'Basantkunj Yojan Sector-I&J" along with associated works including all cost of men, misc, consumables, T&P, Crane etc. to complete the Job satisfactorily
Safe Loading, Carriage of various euipments like- 33 KV VCB, Control cables of various size, MS Flat of various size, 33 KV CT etc. required for construction of 33 KV `Basantkunj Yojan Sector-I, from 132 K.V S/S TRT, 220 KV S/S Hardoi Road, 132 K.V S/S SGPGI and 132 KV S/S Mohan Road, Lucknow to 132 K.V Mehtab Bagh, Lucknow and Unloading at storage place as per direction of Supervising Engineer including cost of Hydra, Carriage vehicle, Men, Misc. consumables, T&P, making coil of cables before loading etc. required for satisfactory completion of Job.(01 Job for all items)
Proper Shifting, sorting, counting weighing, loading & stacking of Stubs/ Gantry Structures on Trucks arranged by the contracotr including transportation from storage location to the loading site.
Safe carriage of theStubs/ Gantry Structures loaded on trucks duly arranged by the Contractor from Stockyard/Stores of E.F.U. Naini Allahabad to 132 KV S/S Jehta (approx. dist 240 km), with all due care of safety & precautions during transit required for the job including the fare/ toll tax etc. of all the trucks.
Unloading of Structures at the 132 KV S/S Jehta including transportation of the structures from the unloading site to the main work site.
Erection of main and auxiliary structures
Main & Auxiliary Structure Lattice type
Erection of following Equipments as per instruction manual and technical specifications including shifting of materials from Central Stores to Erection Site including all associated works.
33 KV VCB with structure
33 KV CT Junction Box.
33 KV PT Junction Box.
33 KV BI without earth blade
33 KV LI with earth blade
33 KV Post Insulator
Jumpering of various equipments with Twin ACSR "Panther Conductor " in after due cutting and bending of conductor and fixing & tightening etc of the Conductor/ Clamps/Connectors/Spacers etc.
Laying of following sizes Control Cables in the Cable Trenches from Control and Relay Panels in Control Room to various Equipments, Junction Box etc. in Swithcyard as per cable schedule, its sddling with 25X3 mm size including carriage of Cable Drums from Stores to work site & shifting back to stores including allother associated works required for the satisfactorily completion of the Job as per technical specification.
Laying of 2X2.5 sq. mm size Control Cable
Laying of 4X2.5 sq. mm size Control Cable
Laying of 6X2.5 sq. mm size Control Cable
Laying of 10X2.5 sq. mm size Control Cable
Interconnection & termination of of the above laid control cables between Control and Relay Panels & erected equipments i.e. CB, CT, CT Junction Box, PT, PT Junction, box. Including making necessary holes in Gland Plates or Boxes whereever required along with supply of Cable glands of appropriate size and providing of Ferrules for each core of the cables & its termination with crimping type Copper Lugs alongwith preparation of Interconnection Drawing and Commissioning of the Panel/ Feeders in co-ordination with T&C Wing includoing providing 02 sets of Hard Copies of as executed Interconnection Drawing including all other associated works required for the satisfactorily completion of the Job as per technical specification. (01 Job for Each Bay)
Cutting, Straightening and Laying 700 mm below inside ground & above ground of 75X10 mm, 50X6 mm, 25X6 mm size M.S. Flats (to be provided by the department) as per requirement for Earthing of newly erected equipments and Structures as above including welding with main Earthmat and with the object to be earthed including excavation, backfilling, painting of the Earthmat above groung level in Bus Green colour including all other associated works to complete the job satisfactorily as per Technical Specifications.
Earthing of Structures and Equipments with 75X10 mm size M.S. Flat
Earthing of Structures and Equipments with 50X6 mm size M.S. Flat
Earthing of cable trenches with 25 mm x 6 mm size M.S. Flat
Painting of Earthing strips above ground level with one coat of Red oxide and two coat of synthetic/ enamel paint and with black Bitumen paint below ground level as per etails below:
75x10 mm (in green color)
50x6 mm (in green color)
25x6 mm (in black color)
Stringing of Main Bus / Transfer Bus. The work laying , stringing of conductor, fitting of tension clamp, hoisting of isolator, cutting of conductor and also shifting of all material from store site to switchyard site and all other associated work.Conductor, fitting and Disc Insulator etc. shall be provided by the department.
Laying & Stringing of 33 KV Main Bus of Moose Conductor Having Length 24 metre.(01 No. for each Phase)
Following works are to be carried out for integration of above 33 kV Bays with existing Nelumbo make SCADA system and all associated work at 132 KV S/S Jehta Lucknow including all cost of men, misc, consumables, T&P, etc. to complete the Job satisfactorily as per direction of the supervising engineer
IEC 6158 based SCADA configuration and its integration with 33 kV bays work include as SLD generation for feeder bays in existing HMI bay IED's ICD files configuration data base correction for newly bays events, alarm generation interlock and soft logic configuration and testing if any GPS time synchronisation etc.
Laying of control cable of 4x2.5 sqmm from Isolator/CB of 33 kV switchyard to C&R panle for status of Isolator and Circuit Breaker and its termination
SCADA and RTU back up restoration work of the existing SAS system
Supply & Fixing of 160 Watt LED street light luminaries (outdoor type) of PHILIPS/CROMPTON GREAVES ]/ HAVELLS/BAJAJ make in single piece aluminium die cast, at designated height on gantry/beam on G.I. Light Bracket including guiding the cable to light fixtures from inside pipe/bracket, cable terminations and it’s testing and commissioning and earthing with 12 SWG Wire.
Supply & Fixing of of G.I. light Bracket duly made of 54 mm dia/dia suitable for Sl. No. 1(a) , 1.2 meter long 'B' class GI pipe and bent at one end by Quarter Circle in 1.0 meter length at an angle of 30 degrees for fixing 120 watt LED Light fitting on Gantry with the help of G.I./ M.S. clamps as required (01 job per Light).
Supply & Fixing of Lighting Junction Box of size 280X225X150 mm duly made of 16 SWG M.S. BP sheet and painted with smoke Grey Colour Synthetic Enamel Paint duly fitted with 01 no. 6 Amp SP MCB on anodized M.S. channel, 01 no. of Bakelite Fuse Fitting with 6 Amp capacity , 1 No. 6A Capacity NS6 type HRC Fuse, 01 no. Copper Neutral Link, Bakelite Terminal Block of 04 Terminals, Cable Glands suitable for 2C/4C X2.5 sq. mm size Including Incoming/ Outgoing Cables etc. and installation of Junction Box. on G.I Pipe Light Pole at designated height with the help of suitable M.S. Clamps alongwith Earthing of Junction Box. with 12 SWG G.I. Wire pole including cable Terminations with satisfacory Testing and Commissioning.
Supply & Fixing of outdoor types 03 phase AC cubical boxes of size 1200x600x300 mm duly painted with one coat of red oxide primer and two coats of synthetic enamel smoke grey paint with 4 nos. aluminium insulted bus bar for connecting ACDB and fitted with one no. 100 Amp. Isolator switch along with 03 nos. 3-Phase MCB of rating 32A, 9 Nos. 3- Phase MCB rating 16A, 3 Nos. 1-Phase MCB of rating 6A MCB Havels make. The cubical box should be made of 16SWG M.S. sheet in the double shutter with indoor locking arrangement complete with proper size wire. TBs for incoming terminals and 18 Nos. TBs for outgoing terminals of standard size and rating.Proper fixing installation testing and commissioning of above cubical Box including all civil and other associated works.The work includes dismantling of Old & Rusted AC Cubicles, disconnection of Power cables and shifting it back to store.
Laying of power cable of size 3.5x 50/95 sq.mm. between Main DB to AC Cubical box, if required, after excavation of trench, Laying the 1st class Brick Lining, Filling of River Sand along & over the cable, then back filling & levelling the trench after laying of cable.The work also includes termination of cable on both sides with crimping of lugs.
Supply & Fixing of Name Plates made of 2 mm thick Aluminium Sheet covered with 3M HIP Retro Reflective Sheet of following size with details/name written as per prescribed colour scheme to be fixed with the help of Nuts and Bolts at already installed Equipments' Structures in the Switchyard with all cost of Plates, Nut & Bolts, misc.materials like chains in case of breakdownshutdown plates etc., T&P and Labour as per Technical Specificaions & direction of the concerned Supervising Engineer:
Plates of size 300 mm X 200 mm
Plates of Size 450 mm X 250 mm
Plates of size 500 mmX 250 mm
Supply & Fixing of Name Plates made of 2 mm thick Aluminium Sheet covered with 3M HIP Retro Reflective Sheet of following size with details/name written as per prescribed colour scheme to be fixed with the help of Nuts and Bolts at already installed Equipments' Structures in the Switchyard with all cost of Plates, Nut & Bolts, misc.materials like chains in case of breakdownshutdown plates etc., T&P and Labour as per Technical Specificaions & direction of the concerned Supervising
MANAS ELECTRICALS
lodhi switchgear enterprises
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .