Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.2 LAccepted-AOC HOUSE NO 01 B JANANA DODI OPP AKSHAY HOTEL RAI KA BAGH JODHPUR RAJASTHAN 342010 | 342010 | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹25.0 L+₹1.2 L (5.01%)Rejected-Finance PAHARGANJ SECOND COLONY LAL SAGAR JODHPUR 342001 RAJ | JODHPUR | JODHPUR | RAJASTHAN | 342001 | L2 | Rejected-Finance NOT LOWEST | |
| 3 | L3₹27.0 L+₹3.2 L (13.3%)Rejected-Finance | L3 | Rejected-Finance NOT LOWEST | |
| 4 | L4₹27.7 L+₹3.9 L (16.4%)Rejected-Finance SHOP NO 13 MOHINI MARKET KISHORE BAGH MANDORE JODHPUR RAJ | JODHPUR | RAJASTHAN | 342001 | L4 | Rejected-Finance NOT LOWEST | |
| 5 | L5₹29.7 L+₹5.9 L (24.7%)Rejected-Finance | L5 | Rejected-Finance NOT LOWEST |
Tender Value
₹34.5 L
EMD Value
₹69,000
Closing Date
16 Jun 2023, 6:00 pmClosed
GE ARMY NO. 1 JODHPUR
GE ARMY NO. 1 MULTAN LINES ARMY AREA JODHPUR
REPAIR REPLACEMENT OF STREET LIGHTS SECURITY LIGHTS AND OTHER ALLIED WORK AT SECTOR C E F AREA IN THE AREA OF AGE E M III UNDER GE ARMY NO 1 JODHPUR
2023_MES_595409_1
GE/J/A- OF 2023-24(9159/E8)
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
JODHPUR
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE ARMY NO. 1
₹69,000
Yes
1 Sept 2023
15 May 2023
19 Jun 2023
15 May 2023
16 Jun 2023
2 Jun 2023
Amount
Disconnecting and taking down old unserviceable LED street light fitting of any size street light fittings with brackets fixed on HT/LT poles, repairing after cleaning and replacing the un-serviceable parts like surge protector, LED driver , clamps etc and reinstallation / reconnecting after replacing wires / jumpers as required for proper functioning of street light fittings complete all as specified and as directed . Note : - Spare parts like surge protector, LED driver shall be measured and paid for as "Supply only" here-in-after.
All as per item No. 1.00 here-in-above, but High mast light fitting.
Supply only in replacement of electronic Driver Input Voltage Range 160V to 260V AC Single Phase 50 Hz and Output Voltage not exceeding 60V DC suitable for upto 30 Watt LED type fitting complete all as specified and as directed.
All as per item No. 3.00 here-in-above, but suitable for 36/40 Watt LED type light fitting.
All as per item No. 3.00 here-in-above, but suitable for 45/50 Watt LED type light fitting.
All as per item No. 3.00 here-in-above, but suitable for 72/75 Watt LED type light fitting.
All as per item No. 3.00 here-in-above, but suitable for 100 Watt LED type light fitting.
All as per item No. 3.00 here-in-above, but suitable for 150 Watt LED type light fitting.
Supply only in replacement of surge Protector not less then 5kV suitable for any Wattage LED type light fittings complete all as per directed.
Labour only for making unserviceable street/security lights serviceable placed at pole by disconnection / Isolating power supply either from pole junction box or by disconnecting overhead jumpers and carrying out de-carbonization / de-sulphation at connection points with overhead conductor / light fitting / junction box terminal including replacement connection wire all as required and as directed by Engr-in-Charge. Note : - Cable shall be measured and paid for as "Supply only" here-in-after.
Supply only in replacement of PVC insulated, sheathed weather proof, copper conductor of size 1.5 sqmm, 3 core complete all as specified and directed.
S&F in replacement of steel structure, as in cross arms bracing supports ,clamps, back plates of any type, section incl. nuts, bolts, washers, welding ,bending cold or hot in any size and shape all as directed Including two coats of aluminium paints over & including M&L single coat of red oxide primer incl preparation of surface, complete all as specified and directed.
Restringing only of ACSR bare/insulated conductor of street / security light feeder including straightening properly on insulators and binding with aluminum taps /binding wire /conductor jumper etc all as directed. Note : - Single conductor shall be measured for length re-stringing.
Supply and fix in replacement of GI tubing of size 50mm bore, medium grade for protection of cables on poles / under road crossing complete all as specified and as directed.
All as per item No. 14.00 here-in-above, but size 40mm bore
Supply, laying, testing & commissioing of 25 Sqmm 4 core size XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured electric power cable heavy duty LT under ground cable 1100 volts grade with stranded aluminium conductor including connection and taking down old U/S cable complete all as specified and as directed.
M&L for Auguring/ Driling /Boring of holes under road, pavement, hard standing by trenchless technology by manual /machine, including fixing of HDPE pipe of 100 mm bore dia complete all as specified and directd by EIC.
Material and labour in replacement for prestressed cement concrete poles 9 M long of size 102 mm x 172 mm at top and 102 mm x 279 mm at bottom class-10, conforming to relavent latest IS including dismantling and refixing of cross arm, security light fittings, brackets or any other existing fittings etc connecting, testing including dismantling and removal of broken pole and coping complete all as specified and directed at site. NOTE:- (i) Earthwork, PCC will be measured and paid separately under relevant item. (ii) Removal of dismantled items from site are included in rate quoted by the contractor.
Excavation in trenches not exceeding 1.5m wide and n.exc. 1.5m in depth for laying of cable and foundation in soft/loose soil complete all as specified and directed.
Excavation in trenches not exceeding 1.5 m wide and exceeding 1.5 m in depth upto 3.0 m for erection of poles, struts/stays, leveling of yard etc not exceeding 10 M² on plan and getting out in soft/loose soil.
Returning filling in and well ramming in layers n. exc. 25cm including spreading, leveling and watering all as specified and directed.
Removing excavated material (soil/rock) and depositing at a distance not exceeding 50m where directed.
Supply and spreading clean dry sand (tibba sand) in trenches for cushioning to PVC cable and punning to provide required cover to UG cable complete all as specified and directed . Note :- Punned thickness shall be measured for the purpose of payment.
Supplying and laying un-reinforced precast concrete cable cover, class LV, type 1, flat size 250 mm x 150 mm x 40 mm and abutting each other with no gap between adjacent precast concrete cable cover suitable for underground cables for protection, complete all as specified and directed .
M&L for plain cement concrete 1:3:6 type C2 by using 40mm graded crushed stone aggregates for foundation of poles / struts / stays etc., complete all as specified and as directed .
M&L for plain cement concrete 1:2:4 type B-1 by using 20mm graded crushed stone aggregate for coping of poles, pedestal including necessary formwork and fair finishing to exposed surface without using extra cement complete all as specified and as directed.
Supply, fixing, testing & commissioing of LED street light fitting 45 Watt 230 V AC, energy efficient, environmental friendly,long life,exclusive, pressure die cast housing with heat resistant toughened glass outdoor type with high pressure die cast aluminum housing and heat resistant toughened glass with high power, complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 66 protection complete for lighting complete suitable to fixed on pole or any other location and connecting with existing cable, including taking down old u/s street light fitting & deposited to MES store yard, complete all as specified and as directed.
S&F in replacement of LED flood light 120 watt 230 V AC, energy efficient, environmental friendly,long life,exclusive, pressure die cast housing with heat resistant toughened glass, outdoor type with thermal management in multiple optics, LED Suittable for highlighting architectural facade and general purpose and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp, complete for lighting complete suitable to fixed on pole or any other location and connecting with existing cable, including taking down old u/s flood light deposited to MES store yard, complete all as specified and as directed.
Material for replacement of unserviceable 'C' curve MCB SP 6 to 32 Amp, 10 KA 240 Volt, complete all as specified and as directed.
Supply and fix in replacement of electric contractor three phase, 415 Volts, 50 Hz, 25 Amp load capacity suitable for street light timer box, complete all as specified and as directed.
Supply and fix in replacement of electric contractor single phase, 230 Volt, 50 Hz, 25 Amps load capacity suitable for street light timer box, complete all as specified and as directed.
M & L for disconnecting and re conecting of burnt LT XLPE cable to OH conductor on pole/ equipment including removing of faulty part of cable, preparation of cable for connection, suitable AL lugs, nut bolts etc , complete all as specified and as directed. Note: The cost of earth work for taking out LT cable loop and returning filing shall be deemed to be included in the qoted rate.
Preparation of old painted surfaces above the planting depth / PCC coping of steel tubular poles of 9/11 mtr length including MS clamps, cable protection pipe, bracket fitted with street light fitting by scrapping with steel wire brush and applying two coats of aluminium paint to external surfaces of pole, MS cross arms and clamps, cable proecion pipe etc.,including zebra colour of painting up to 1.5mtr height from top of the coping / bottom of pole as per site condition, complete all as specified and as directed . Note :- Zebra colour will be applied by synthetic enamel paint of black / yellow colour as approved in alternate strips of each 30cm width.
Material and labour for writing pole number of minimum size 10 cm height with black paint over base of yellow paint on PCC/steel poles of LT/HT supply complete all as directed by EIC.
Preparation of old painted surfaces of LT PCC poles of 9/11 mtr length and applying zebra colour of painting up to 1.5mtr height from top of the coping / bottom of pole as per site condition including preparation of MS clamps, cable protection pipe, bracket fitted with street light fitting by scrapping with steel wire brush and applying two coats of aluminium paint to external surfaces MS cross arms and clamps, cable proecion pipe etc.,complete all as specified and as directed . Note :- Zebra colour will be applied by synthetic enamel paint of black / yellow colour as approved in alternate strips of each 30cm width.
M&L for trimming, cutting and pruning of one complete tree up to a safe distance from the over head lines incl cutting branches of size not exceeding 80mm dia complete all as directed at site and disposal of branches/bushes to a distance and clearing the site all as directed. NOTE :- 1. The necessary man power, tool & plant, cutting tools and JCB required for cutting/pruning of branches is deemed to incl in the rate quoted for the job. 2. Proper shut down will be taken by the authorised rep only. 3. One Job will be considered for trimming/ prunning of one complete tree branches of given size.
Supply and fixing in replacement of digital timer switch, astronomical type for auto & manual type on and off, having supply voltage range 110-240VAC, 50/60Hz, minimum switching time not more than 1 minute, LCD display, complete all as specified and directed.
Supply and fix in replacement of junction box of size 250×200×100 mm, weather proof, made out of polycarbonate with glass fiber reinforced, IP 65 rated, Pole mounting type, along with 4 way connector for 3 phases and neutral and MCB SP - 0.5 Amps rating incl power terminal 25sq.mm (6 Nos) and M32 Cable glands suitable for 25sq.mm x 4 core cable I/C & O/g (2 Nos) complete all as specified and directed.
M&L in replacement of PVC conduit 20 mm, heavy duty rigid non metallic including of all tee, bends, elbows etc complete all as specified and as directed.
Supply and fix in replacement of GI pipe Bracket of 25/32/40 mm dia light grade pipe bend to shape of approx length 1.20 Mtr complete all as specified and directed at site.
Supply and fixing in replacement of LED post top fitting as gate light aesthetically designed and soft illumination effect of 2450 lumen including LED lamp of rating 40 watts and connecting complete all as specified and directed.
Supply and fix in replacement street light timer box having astronomical type digital time switch for (auto/manual) on and off, electric contractor three phase 415 Volts 50 Hz upto 25 Amps, MCB single phase 230V 63 Amps-6 Nos, TPN connector for incoming and outgoing cable, all fixed on laminated board and interanally connection with suitable size of copper cable including PVC cable gland M32, aluminium lugs/thimble of suitable size for incoming & outgoing cables of any other required spare etc complete all as specified and directed.
Earthing complete with galvanized steel earth plate electrodes 600mmx600mmx6 mm thick buried directly in ground earth (earth pit not less 2.25 m deep below ground level) with top edge of the plate not less then 1.5 mtr below normal ground level connected to galvanised iron earthing strip 32mm x6mm thick by means of bolt nuts check nuts and washers of galvanized iron or steel all as specified & shown in electrical plate No.3 of MES SSR part-I 2009 connected to earth test point as specified and testing on completion including provision of 40 mm dia light grade pipe up to 7.5 mtr length as protection & watering pipe shall be 20 mm bore medium grade including all excavation & earth work in any type of strata incl PCC pit (1:3:6) type C-1 with RCC cover including charcoal , salt, funnel, all as directed at site. Note : Rate included for dismantling of old earth pit and removal from site.
Supply and fix in replacement of pin type porcelain insulator, vitreous white brown or green including one galvanised mild steel spindle two GI washer and GI Nuts 100 mm height 65 mm dia for 1100 volts grade complete all as specified.
Supply and fix in replacement of shackle type porcelain vitreous white insulator 1100 volt grade 75 mm in height and 90 mm dia including galvanised mild steel strap of size 31mm x 3mm, 12 mm dia insulators bolts, washers and nuts complete all as specified.
Shree Karni Construction
M/S SUMAN ENTERPRISES
Sachiyay maa Electricals
LOKESH ELECTRICAL WORKS CONTRACTOR
Narendra General Suppliers
new india engineers
Shri Electrical Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .