State Project Director, Gujarat Council of School Education (GCSE)
Upgradation of 3 School for School of Excellence at various Location in MAHISAGAR district.
366932
SS/SOE/MAHI/8010
Open
Civil - All
Works
Gandhinagar
3 documents required · 3 mandatory
₹3,600
State Project Director, GCSE, Samagra Shiksha, Gandhinagar
₹1.5 L
23 Nov 2026
23 Nov 2026
23 Nov 2026
15 Dec 2026
23 Nov 2026
120 days
Excavation for foundation upto 1.5 m depth including sorting out and
stacking of useful materials and disposing off the excavated stuff upto
50 Meter lead.(A)
Loose or soft soil
Excavation for foundation for depth from 1.5 m to 3.0 m including
sorting out and stacking of useful materials and disposing off
the excavated stuff upto 50 Meter lead.(A) Loose or soft soil
Filling with the available excavated earth (excluding rock) in trenches, plinth,
12 sides of foundation etc. in layers not exceeding 20cm in depth consolidating 200.24 136.92 Cmt.
each deposited layer by ramming and watering.
Filling foundation and plinth with murrum or selected soil in layers of 20 cm.
13 thickness inculding watering, ramming and consolidation etc. complete. 135.34 295.15 Cmt.
Filling in plinth with sand under floors including watering ramming,
consolidating and dressing complete
Brick work using common burnt clay building bricks having crushing
15 strength not less than 35 kg./Sq.Cm. in foundationand plinth in Cement 112.74 4978.22 Cmt.
Mortar 1:6. (1‐ Cement : 6 ‐finesand)(C) Fly Ash Bricks
Brick work using common burnt clay building conventional bricks having
crushing strength not less than 35 Kg/Sq. cm. in foundation and plinth in
cement mortar 1:4 (1 Cement :4 fine sand) (C) Fly Ash Bricks(For Earth
Masonry work with aerated light weight concrete Blocks of size 60cm x
23cm x 23cm or any other approved size, having crushing strength @
kg/sqcm Fixing with ready-mixed mortar ('Fixoblock'of M/s Ultratech
17 cement Ltd./Rapid Fix/Lion) having tensile adhision strength >0.8 N/mm2 92.03 4422.00 Cmt.
and compressive strength of >2N/mm2.The mortar is to be fixed in a
thickness of 3mm to 5mm on the clean and leveled surface of blockmasonry
using proper trowel. For all floor and lead and lift For superstructure.
Brick work using common burnt clay building bricks having crushing
strength not less than 35Kg./Sq.Cm. for superstructure in cement mortar
1:6(1 cement :6 fine sand) including curing etc. complete. (C) Fly Ash Bricks
For all heights and all floor
DESCRIPTION OF ITEM QTY RATE Per Unit
Half brick in common brunt clay building bricks having crushing strength not
less than 35 Kg/sq.cm in cement mortar 1:4 (1 cement : 4 coarse sand) (C)
Fly Ash Bricks in super structure including curing etc. complete.For all
Providing & laying Cement Concrete 1:4:8 (1 Cement :4 Coarse sand :8
hand brocken stone aggregates of 40mm nominal size) in plinth and curing
complete including cost of formwork. (A) Foundation and Plinth - At plinth
Providing and laying cement concrete 1:5:10 (1- Cement : 5- Coarse sand :
10- hand broken stone aggregates 40 mm nominal size) and curing complete
including cost of formwork in (A) Foundation and Plinth
Providing & laying Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand :
graded stone aggregate 20 mm nominal size) & curing complete including
cost of form work (A) Foundation and Plinth -Below Tie beam, Plinth
protection & surface leveling work.
Providing and laying cement concrete flooring 1:2:4 (1-cement : 2-coarse
23 sand : 4-graded stone aggregate 20mm nominal size) laid in one layer and 102.78 297.31 Smt
finished with a floating coat of neat cement. (A) 40mm thick.
Providing and laying controlled cement concrete M.150 for curing
complete including cost of formwork and excluding cost of reinforcement
24 for reinforced concrete work in (A) Foundations, footings,Base of 15.60 4267.69 Cmt.
columns and Mass concrete (Cement Level 290 Kg)
Providing and laying controlled cement concrete M.200 and curing complete
including the cost of formwork and excluding the cost of reinforcement for
reinforced concrete work in (C) Coping Vertical and horizontal for all floor
(Cement Level 360 Kg)
Providing and laying controlled cement concrete M.250 and curing complete
including the cost of formwork and Excluding the cost of reinforcement for
reinforced concrete work in (A) Foundations, footings, Base of columns and
Mass concrete.(Cement Level 380 Kg)
Providing and laying controlled cement concrete M.250 and curing complete
including the cost of formwork and Excluding the cost of reinforcement for
reinforced concrete work in Plinth Beams. (Cement Level 380 Kg)
Providing and laying controlled cement concrete M.200 and curing complete
including the cost of formwork and excluding the cost of reinforcement for
reinforced concrete work in (C) Lintels all floor (Cement Level 360 Kg)
Providing and laying controlled cement concrete M.200 and curing complete
including the cost of formwork and excluding the cost of reinforcement for
reinforced concrete work in (C) Chajja all floor (Cement Level 360 Kg)
Providing and laying controlled cement concrete M.200 and curing complete
including the cost of formwork and excluding the cost of reinforcement for
reinforced concrete work in (C) Beams all floor (Cement Level 360 Kg)
Providing and laying controlled cement concrete M.250 and curing complete
including the cost of formwork and excluding the cost of reinforcement for
reinforced concrete work in (D) Columns, Pillars posts and struts all floor
(Cement Level 380 Kg)
Providing and laying controlled cement concrete M.200 and curing complete
including the cost of formwork and excluding the cost of reinforcement for
reinforced concrete work in (D) Columns, Pillars posts and struts all floor
(Cement Level 360 Kg)
Providing and laying controlled cement concrete M.200 and curing complete
including the cost of formwork and excluding the cost of reinforcement for
reinforced concrete work in (C) Slab all floor (Cement Level 360 Kg)
DESCRIPTION OF ITEM QTY RATE Per Unit
Providing and laying controlled cement concrete M.200 and curing complete
including the cost of formwork and excluding the cost of reinforcement for
reinforced concrete work in (E) Staircases including lending all floor
(Cement Level 360 Kg)
Providing I.S.I. T.M.T Bars Fe.500D steel reinfocement (ISI mark)
35 Confirmed to IS-1786 for R.C.C.work including Cutting, bending, binding 29530.63 77.29 Kg.
and placing in position etc. complete.For all floors
Providing 10mm thick cement plaster in single coat on on brick/concrete
walls & Ceilling & Soffit of stair interior plastering in cement mortar 1:4(1
cement 4 sand) watering, curing etc. complete.For all floors
Providing 15mm thick cement plaster in single coat on rough or fair side of
37 single or half brick wall for interior plastering in cement mortar 1:4(1 cement 2415.19 201.44 Smt
4 sand) watering, curing etc. complete.For all floors
20mm thick sand faced cement plaster on walls above ground level
consisting of 12mm thick backing coat of cement mortar 1:3(1 cement
sand) and 8mm thick finishing coat of cement mortar 1:1(1 cement 1 sand)
watering, curing etc.complete for any Height.
Finishing walls with 100% Premium acrylic emulsion paint having VOC less
than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal
resistance, dirt resistance exterior paint of required shade (Company Depot
39 Tinted) with silicon additives. New work (Two or more coats applied @ 1.43 5771.11 183.06 Smt
litre/ 10sqm. Over and including priming coat of exterior primer applied @
0.90 litre/10 sqm, Item Includes two coat of primar and putty with scafolding
at all level of work. As per Approval of Engineer Incharge.
Distempeing (Two coats) with oil bound washable distemper having VOC
content les than 50 grm/liter of approved brand and manufacture and of
required shade on wall surfaces to give an even shade, over and including a
40 priming coat and putty with alkali resistance primer of approved brand after 6648.35 93.92 Smt
thoroughly brushing the surface and other foreign matter and also including
preparing the surface even and sand parpered smooth As per Approval of
Engineer Incharge
Painting two coates (Including Priming coat)having Low VOC content over
new steel and other metal surfaces with enamel paint,primar coat, brushing,
interior to give an even shade including cleaning the surface of all dirt,oil,
grease,dirt, dust and other foreign matter with fine steel wood, scrapers and
sand paper with ready mixed priming paint brushing red lead etc.
complete.(As directed by Engineer in charge)
Providing and laying 25mm thick polished Kota stone flooring/staircase
treads (two pieces with three groves in front of steps) over 20mm (average)
42 thcik base of cement mortar 1:6 (1 cement 6 coarse sand) laid over and 487.88 1019.39 Smt
jointed with grey cement slurry including curing, rubbing, and polishing etc.
Providing & fixing average 25mm thick Double polished Kota stones for
43 shelves in cup board, seating plat form, including curing, rubbing, polishing 24.87 807.34 Smt
etc. complete. (As directed by Engineer in charge)
Providing and laying 18 mm thick mirror polished black granite stone
machine cut in single piece (Max. available) in sill and jambs laid over
mm thick cemen mortar 1 : 3 (1 cement : 3 coarse sand) and jointed with grey
44 cement slurry with matching pigment incl. rubbing and polishing half 35.93 2061.06 Smt
rounding edge both side etc. complete colour and shed as approved by
architect engineer in charge. (As directed by Engineer in charge)
providing & laying cement water proofing of average 60mm thick for terrace
for all floors using first layer cement mortar (1:3) over an exsisting surface
second layer of arranging brick bats acording to slop adding suitable
45 chemical to make water tieght & again third layer of cement mortar 1:3 on 435.83 353.98 Smt
above including adding water proffing compound and finishing top with net
cement slury using cement @ 2.75 kg/sq mt. making any patterns and design
on the top etc. complete as directed.(As directed by Engineer in charge)
DESCRIPTION OF ITEM QTY RATE Per Unit
Providing & Laying Broken China Mosaic flooring for plain & curve surface
12mm to 20mm of broken piece of ceramic tiles or Glazed tiles ( one or more
colour as directed by Engg. In charge ) to be laid over cement mortar
bedding of CM 1:3 to plain or and slopes and to be tempered to bring mortar
46 cream up to and colour pigment including rounding of junctions and 944.69 779.70 Smt
extending them pu to 15cms along the wall and curing with bends any
patterns of designs as per deawing or directions including cleaning with
water and oxilic acid using 1 kg / 1 bag of water proofing materials.
Providing cement vata (10 cm X 10 cm size) quartar round in cement mortar
1:1 including neat cement finishing, watering etc. complete Respectely
plaster acitivity shall be commenced only after completion of vata work.
Providing & fixing in position mild steel door with ventilation frame
40x40x6 mm and shutter frame 35x35x5mm ,75x5 mm ms flate at lock
rail,10 mm square bar in vent at10 cm c/c coverd with corrugated ms sheet
48 0.6 mm thick, including applying a priming coat of read lead paint including 39.39 3718.05 Smt
cleanicn the surface of all dirt, dust and other foreign matter (As directed by
Engineer in charge& approved drawing and design etc.)
Providing & fixing in position mild steel window with ventilation frame
35x35x5 mm and shutter frame 25x25x5mm ,10 mm square bar grill at10 cm
c/c coverd with corrugated ms sheet 0.6 mm thick,including applying a
priming coat of read lead paint including cleanicn the surface of all dirt, dust
and other foreign matter (As directed by Engineer in charge& approved
drawing and design etc.)
Providing and fixing window having extruded aluminum Colour Powder
Coated section frame main outer size 63.50 x 38.10 x 1.95 mm(of Jindal
Section no:4605,@ Wt 1.094 Kg / Rmt), horizontal two track member size
61.85 mm x 31.75 mm x 1.20mm (of Jindal Section no: 8687 @ wt.of
Kg/mt), vertical member of size 61.85 mm x 31.75mm x 1.30 mm (of Jindal
Section no:8758 @ wt.of 0.0.659 Kg/mt) with sliding shutters of horizontal
50 member size 40mm x 18mm x 1.29mm (of Jindal Section no:8949 @ wt.of 14.85 1713.70 Smt
0.456Kg/mt), vertical member of size 40mm x 18mm x 1.29mm (of Jindal
Section no:8947 @ wt.of 0.456Kg/mt/ Section 8948, @ Wt. 0.457 Kg/mt)
with 5 mm thick transparent bronze colour tinted float glass with powder
coated aluminum fittings and fixtures and transparent silicon sealant glass
fixing to frame as per details etc complete for window.
Steel work, M.S Grill, welded in built up sections framed work including
cutting, hoisting, fixing in position and applying a priming coat of read lead
51 paint. (A)In beams and joists, channels angles Tees, flats, with connecting 4882.04 91.08 Kg.
plates or angle cleats as in main and cross beams. Hip and jack rafters,
purlins conneted to common rafters and the like
52 Providing & fixing G.I rain water Spout of 65mm dia and 60cm length. 49.00 717.46 No.
Painting of logo on front side wall as directed by Engineer in charge and as
per approved drawing.
Providing and laying white glazed tiles 6mm thick in flooring treads of
steps and landing laid on a bed of 12mm thick cement mortar 1:3 (1-
cement : 3-coarse sand ) finishing with flush pointing in white cement.
Providing and laying white glazed tiles 6mm thick in skirting, riser of steps
55 and dedo on 10mm thick cement plaster 1:3 (1-cement : 3 coarse sand) and 13.95 993.83 Smt
jointed with white cement slurry.
Providing and fixing Chicken mesh jali (22 gauge) 15cm wide at the junction
of 2 different surfaces of different material component at the time of
plastering to prevent cracking in plaster surface as and where directed at all
floors with all leads and lifts etc.complete.
Providing & Fixing Green board(2400mm x 1200mm) with soft
57 board(1200mm x 1200mm) on wall as per the drawing & design etc. 16.00 10352.50 No.
DESCRIPTION OF ITEM QTY RATE Per Unit
Providing upto floor two level precast cement concrete jali or grill 1:2:4 mix
(1- Cement : 2- coarse sand : 4-graded stone aggregate 6mm nominal size)
58 reinforced with 1.6 mm dia. Mild steel wire including roughening,cleaning, 2.16 855.66 Smt
fixing and finishing in cement mortar 1:3 and curing complete.(E) 100mm
Providing and fixing pre-cast Rubber Dye / steel Dye inter locking
concrete block 60mm thick with grade of concrete M300 pnumatic
compressed / vibrated mechanically and as per approved design
Confirming to IS 15658 : 2006 including 35 mm Sand layer for levelling and
filling the joint with sand in proper line and level as per guidlines of IRC : SP
63-2018 etc. Complete.
Re-fixing of existing paver Blocks:
Fixing of existing pre-cast Rubber Dye inter locking concrete block as per
approved design including 35mm Sand layer for levelling and filling the joint
with sand in proper line and level etc complete.
Providing and fixing pre-cast concrete kerb stone of gray cement based
concrete block 30 cm length, 30cm height and 15cm thick of M250 grade
61 concrete as per aprooved design and including excavation for fixing in 67.00 374.92 Rmt
proper line and level, filling the joint with C:M 1:3 (1 Cement : 3 Fine sand)
etc. complete (uptp 10 ton).
Provoding and supplying small dust bin (Green,Blue,Red,Black yellow,)
62 Litres as directed by Engineer in charge, Approve Make- Cello, Aristo, 21.00 290.38 No.
Provoding and supplying big dust bin (Green,Blue,Red,Yellow) 20 Litres as
63 directed by Engineer in charge Approve Make- Cello, Aristo, Nayasa 14.00 464.60 No.
Provoding and supplying big dust bin ( Green,Blue,Red) 50 Litres as directed
by Engineer in charge Approve Make- Cello, Aristo, Nayasa
Providing and Fixing 5mm thick Acrylic Name Plate for dark zink glare with
braille lippi and fixing with double sided bonding tap and screws as per
direction of Engineer in charge of Size having 12'. X 4 ' etc. compl.
Providing and Fixing 5mm thick Acrylic Name Plate for dark zink glare with
braille lippi and fixing with double sided bonding tap and screws as per
direction of Engineer in charge of Size having 12" X 18" etc. compl.
Providing and laying tactile tile (for vision impaired persons as per
standards) of size 300x300x15 mm having with water absorption less than
0.5% and conforming to IS:15622 of approved make in all colours and
67 shades in for outdoor floors such as footpath, court yard, multi modals 83.95 1850.03 Smt
location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement :
coarse sand) in all shapes & patterns including grouting the joints with white
cement mixed with matching pigments etc. complete as per direction of
Engineer-in-Charge.
Providing and fixing School of Excellence Logo Size ( 900mm x 900mm
),Aluminium Composite Panels (ACP) 3mm thickness,Coloe Code - PS
Blue,High Glossy 3mm Orange Acrylic Embossing Logo,Back Side
Aluminium Section Framing ( 50mm x 25mm x 1mm )25mm is Side Of
Frame and SS Hardware Finish on front side of ACR wall as directed by
Engineer in charge and as per approved drawing.
Providing and fixing Red Agra stone takti 0f size 600*600*12 to 15 mm
having with approved SOE LOGO Letter and in ivory colour with water
based sealent coating finishing on wall in cement mortar 1:3 (1 cement :
coarse sand) in all shapes & patterns including grouting the joints with white
cement mixed with matching pigments etc. complete as per direction of
Engineer-in-Charge.
Painting two coats (including priming coat) on new steel and other metal
surface with synthetic enamel paint, brushing to give an even shade including
cleaning the surface of all dirt, dust and other foreign matter.
DESCRIPTION OF ITEM QTY RATE Per Unit
Construction of a soak well of as per the approved drawing & design etc.in
all sort of soil complete as directed and approved by engineer incharge.( The
internal In-to-in dimension shall be considered for calculation)
Construction of a septic tank as per the approved drawing & design etc.in all
sort of soil complete as directed and approved by engineer incharge. ( The
internal In-to-in dimension shall be considered for calculation)
RCC GSR ( description of item for turnkey tender)
Preparing structural design of RCC Under Ground / Partially under ground /
above high ground level Reservoir of required capacity as per relevant I.S.s
and constructing the same, including excavation in all types of soil strata
(including rock) including shoring strutting if required, for loose soil / to
protect from collapse due to near by traffic load, casting 100 mm thick
P.C.C. leveling course in M-10, Refilling the pit with proper soil and
disposing of the surplus stuff within a lead of 50 meters. Including cement
plaster in CM 1:2 with approved water proofing compound to inside water
touching surface to container. Including all types of labour and material
charges of lowering, laying, erecting / hosting and jointing of pipe assembly
to inlet, outlet overflow, washout and bye pass arrangement as per hydraulic
design. Providing and fixing accessories like MS / GI Ladder, CI Manhole
frame and cover, water level indicator, adequate cowl type ventilators or
lantern type ventilator with stainless steel jail. B.B. Masonry chambers for
73 valves. Providing and applying three coats of cement paint / snowcem to the 4000.00 6.32 Liter
out side face of structure. It also includes satisfactory water tightness test as
per relevant I.S. code and painting name of scheme and capacity on the tank
as per direction of engineer in charge. List of Indian Standards for Design of
GSR / SUMP:-The structural design of GSR shall be in accordance with
provisions relevant I.Ss. (1) I.S. 3370 part I & II 2009 or latest revised (1.1)
I.S. 3370 part III & IV 1965 or latest revised (2) I.S. 456 – 2000 or latest
revised. (3) I.S. 1893 – 2000 – 1984 or latest revised. (4) I.S. 875, Part – 1 to
3, 1987 or latest revised. General Specifications:-(1) Water depth in
container shall be adopted as per data of tender. If water depth is not
specified the suitable water depth / acceptable to field engineer in accordance
with hydraulic requirement shall be adopted for capacity. (2) Shape of
container (in plan) specified by in data shall be adopted in absence circular
shape shall be adopted. (3) Size shall be fixed as per availability of space
(land area) at site / acceptable engineer in charge. (4) Effect of overlapping
of pressure bulbs on soil due near by structure and proposed sump should be
Providing (5)fixing
Care shall be taken
washbasin withthat no damage
single hole forshould occur
pillar tap to M.S.
brackets painted white including sutting holes and making good the same but
74 excluding fittings.(A) Vitreous China:(ii) Flat Back washbasin 550 mm x v 3.00 1828.12 No.
400mm size. (i) In white colour including CP Brass west , MI Fisher union
Providing & fixing Stainless steel 316 Grab Bar 40mm dia.75Cm long rail.as
directed and approved by engineer incharge.
Construction of ICN Chamber as peras directed and approved by engineer
Providing and fixing screw down bib taps of following size.(B) Brass
chromium plated screws down Bib Tap. (i) 15mm dia.
Constructing brick masonry chamber for underground C.I. Inspection
chamber and bends with bricks having crushing strength not less than
35Kg/Cm2 in C.M. 1:5 C.I. cover with frame (Light duty) 455mm x
610mm intenal dimensions total weight of cover with frame to be not
less than 38Kg. (Wt. of cover 23 Kg.) and Wt. of frame 15Kg.)
78 (R.C.C. top slabe with 1:2:4 mix (1-cement :2- coarse sand :4-graded 3.00 3175.32 No.
stone aggregate 20mm size) foundation concrete 1:5:10 inside
plaster 15mm thick with cement mortar 1:3 finished smooth with a
floating coat of neat cement on walls and bed concrete etc.
complete.(i) Inside dimensions 455mmx 610mm and 450mm
deep for single pipe line.
DESCRIPTION OF ITEM QTY RATE Per Unit
Providing and fixing wash down water closet (European type W.C
pan) with integral P or S trap including jointing the trap with soil pipe
79 in cement mortar 1:1 (1 cement : 1 fine sand) (seat cover,Jet spray & Flush 3.00 1911.92 No.
Tank to be measured Including) (A) Vitreous China (I) Long pattern white
as directed and approved by engineer incharge.
Providing erecting and fixing double coated ISI water tank of required
80 capacity each with all necessary fittings and connection etc. complete on 1800.00 3.95 Liter
Providing & fixing UPVC ball valve(A) 25mm dia.
Providing and fixing S.W. gully trap with C.I. grating
brick masonry chamber and water tight C.I. cover with frame of 300mm
x 300mm size (inside) with standard weight.(i) Square mouth traps.(B)
150mm x 100mm size P or R type
Providing and fixing PVC SWR Nahni trap IS 14735 for drain -
75 mm diameter with jali of the following nominal diameter of
self cleansing design with C.I scread down or hinged grating
including the cost of cutting and making good the walls.
Providing laying and jointing in true line and level 40mm
dia. U.P.V.C. Pipe ( SCH- 40) for cold water including fittings
as approved by Engineer In Charge. Pipe shall be fixed on the wall
84 with the help of clamp at every two metre C/C or shall be 101.00 148.12 Rmt
concealed as directed including necessary fittings etc. including
testing of pipe and joints and fixing the same with
adhesive solvent, including cost of all materials.
Providing laying and jointing in true line and level 25mm
dia.U.P.V.C. Pipe ( SCH- 40) for cold water including fittings
as approved by Engineer In Charge. Pipe shall be fixed on the wall
85 with the help of clamp at every two metre C/C or shall be 121.70 91.84 Rmt
concealed as directed including necessary fittings etc. including
testing of pipe and joints and fixing the same with
adhesive solvent, including cost of all materials.
Providing laying and jointing in true line and level 15mm
dia.U.P.V.C. Pipe ( SCH- 40) for cold water including fittings
as approved by Engineer In Charge. Pipe shall be fixed on the wall
86 with the help of clamp at every two metre C/C or shall be 50.30 72.65 Rmt
concealed as directed including necessary fittings etc. including
testing of pipe and joints and fixing the same with
adhesive solvent, including cost of all materials.
Providing & fixing to wall ceiling and floor 6.0 kg F/cm2 working pressure
PVC pipes of the following out side dia. Special density complete with
special flange compression type fitting,wall clips etc. including making good
the wall ceiling and floor.(G) 160 mm dia
Providing & fixing to wall ceiling and floor 6.0 kg F/cm2 working pressure
PVC pipes of the following out side dia. Special density complete with
special flange compression type fitting,wall clips etc. including making good
the wall ceiling and floor.(G) 110 mm dia
Providing & fixing to wall ceiling and floor 6.0 kg F/cm2 working PVC
pipes of the following out side dia. Special density complete with special
flange compression type fitting,wall clips etc. including making good the
wall ceiling and floor.(F) 75 mm dia
Providing laying (to level or slopes) and jointing reinforced concrete Light
duty non- pressure pipes I.S. class NP2 of the following internal
diameter with collars and butt ends prepared for collar joints including
testing of joints complete.(D) 300 mm
Providing and laying polished kota stone slab 25mm thick in risers of
steps,skirting Dedo and pillars laid on 10mm thick cement mortar 1:3 (1-
91 Cement : 3 coarse sand) and jointed with gray cement slury mixed with 47.30 1177.56 Smt
pigment to match the shade of slab including rubbing and polishing etc.
Providing compose pit as per design and drawing.
DESCRIPTION OF ITEM QTY RATE Per Unit
Providing and laying Vitrified tiles 8 to 10 mm thick , 24'' x 24'' in flooring
treads of steps and landing laid on a bed of 12mm thick cement mortar 1:3 (1-
cement : 3-coarse sand ) finishing with flush pointing in white cement
complete for antiskit
Providing and laying Vitrified tiles 8 to 10 mm thick , 24'' x 24'' in skrting
94 risers of steps and dedo on 10mm thick cement plaster 1:3 (1-cement : 3- 152.00 1195.02 Smt
coarse sand) and jointed with white cement slurry complete for antiskit
Providing laying and boring recharge well with the outer dimention of 2.46 X
2.46 Mt along with the Slit chamber having outer dimension of 1.46 X
Mt. The Slit chamber shall be as per the approved drawing with PCC &
Masonary work. The recharge well shall be drilled up to 30Mt in all sorts of
95 strata along with minimum 12 mt Strainer pipe of suitabel size, graval / 14.00 71879.59 No.
aggregate packing, PCC, BBCC , Midium size gravel, Course sand, nyloin
mesh, and neccesarry tools tackels and quipment for sucessfully functioning.
The item shall be as per the IS 15797:2008 , approved drawing and
Approved by Engineer incharge.
Point wiring for Light / Bell with 2-1.5 sq.mm & earth wire of 1.5 sq.mm
(Green) both are of ISI marked 1.1 KV grade FRLS PVC insulated multi
strand copper wires up to 10 mtr length , in below type of pipe erected with
6A Modular type switch / bell push & accessories and earth continuity of
96 following type, erected on PVC / Metallic/Wooden box, single mounting 30.00 350.47 Pt.
base frame covered with textured/metallic/white front plate modules erected
on / in wall / ceiling as per pipe erected, with necessary Lamp holder/ceiling
rose / H.D.Connector as directed.(e) in existing pipe erected flushed on
wall/ceiling complete,Cat. III
Point wiring for FAN with 2-1.5 sq.mm & earth wire of 1.5 sq.mm (Green)
both are of .ISI marked 1.1 KV Grade FRLS PVC insulated multi strand
copper wires up to 10 mtr length, in below type of pipe erected with 6A
Modular type switch and hum free EME step type electronic fan regulator
97 mounted and accessories with earth continuity of following type erected on 30.00 489.85 Pt.
PVC / Metallic/Wooden box, single mounting base frame covered with
textured/metallic/white front plate modules erected on / in wall / ceiling as
per pipe erected. with necessary ceiling rose / H.D.Connector as directed.(e)
in existing pipe erected flushed on wall/ceiling complete,Cat. III
Point wiring for Individual Plug with & earth wire of 1.5 sq.mm (Green)
both are of ISI marked 1.1 KV grade FRLS PVC insulated multi strand
copper wires up to 10 mtr length, in below type of pipe erected complete
with Modular type switch & 5 pin Plug erected on PVC / Metallic/Wooden
98 box covered with appropriate front plate modules erected on / in wall / 10.00 364.61 Pt.
ceiling as per pipe erected with following type of accessories.[I] For 6A Plug
and 6 a switch with 2-1.5 sq.mm Cu. Wire from nearby switchboard/mcb db
board(e) in existing pipe erected flushed on wall/ceiling complete,Cat. III
Point wiring for Individual Plug with & earth wire of 1.5 sq.mm (Green)
both are of ISI marked 1.1 KV grade FRLS PVC insulated multi strand
copper wires up to 10 mtr length, in below type of pipe erected complete
with Modular type switch & 5 pin Plug erected on PVC / Metallic/Wooden
99 box covered with appropriate front plate modules erected on / in wall / 5.00 499.95 Pt.
ceiling as per pipe erected with following type of accessories.[II] For 16A
Plug and 16 amp switch with 2-2.5 sq.mm Cu. Wire from mcb db board.(e)
in existing pipe erected flushed on wall/ceiling complete,Cat. III
Point wiring for on board Looped Plug with 6A Modular type switch & 5 pin
socket erected on PVC / Metallic/Wooden box, single mounting base frame
covered with textured / metallic/white front plate modules erected on / in
wall / ceiling with following type accessoriesCat. III
DESCRIPTION OF ITEM QTY RATE Per Unit
Point wiring for Two Way Controlled Light Point with 2-1.5 sq.mm & earth
wire of 1.5 sq.mm (green) both are of .ISI marked 1.1 KV grade FRLS PVC
insulated multi strand copper wires erected in below type of pipe with 6A
Modular type switches and following type of accessories erected on PVC /
101 Metallic/Wooden box, single mounting base frame covered with textured / 10.00 449.45 Pt.
metallic/white front plate modules erected on / in wall / ceiling as per pipe
erected. with necessary batten/angle holder or ceiling rose or H.D.Connector
as directed.(e) in existing pipe erected flushed on wall/ceiling complete Cat-
Providing following type of Modular Type Accessories mounted with PVC /
metallic/Wooden box, single mounting base frame covered with textured /
102 metallic/white front plate , modules erected with necessary connections as 5.00 190.89 No.
per site situation directed by Engineer In charge.(10) 6/16Amp. Universal
Providing following type of Modular Type Accessories mounted with PVC /
metallic/Wooden box, single mounting base frame covered with textured /
103 metallic/white front plate , modules erected with necessary connections as 20.00 24.24 No.
per site situation directed by Engineer In charge.(7) Blank Plate
Providing following type of Modular Type Accessories mounted with PVC /
metallic/Wooden box, single mounting base frame covered with textured /
104 metallic/white front plate , modules erected with necessary connections as 2.00 153.52 No.
per site situation directed by Engineer In charge.(8) Computer RJ-45 socket
Providing and erecting ISI mark embossed Medium class RIGID PVC PIPES
(F.R.L.S.)of following size complete to be erected on/in wall or ceiling
105 erected with necessary PVC fittings & Junction boxes fixed with adhesive 250.00 23.23 Mtr.
solution & Clamps with following dia of pipes, in approved manner as
directed (a) 20 mm
Providing and erecting ISI mark embossed Medium class RIGID PVC PIPES
(F.R.L.S.) of following size complete to be erected on/in wall or ceiling
106 erected with necessary PVC fittings & Junction boxes fixed with adhesive 87.00 32.32 Mtr.
solution & Clamps with following dia of pipes, in approved manner as
directed (b) 25 mm
Providing & erecting PVC Corrugated Flexible Conduit with required nos. of
107 coupling, PVC bushes, Check-nuts etc. complete of following sizes.(2) 25 5.00 20.20 Mtr.
Providing and erecting Mains with 1.1 KV grade FRLS PVC insulated ISI
marked stranded Copper conductor wire in following type of pipe to be
erected concealed in /flushed on wall/ceiling, with 1.5 sq. mm copper
conductor FRLS PVC insulated stranded wire of green colour for earth
continuity of following size,(E) in existing pipe,(a) 2 wire 1.5 sq. mm
Providing and erecting Mains with 1.1 KV grade FRLS PVC insulated ISI
marked stranded Copper conductor wire in following type of pipe to be
erected concealed in /flushed on wall/ceiling, with 1.5 sq. mm copper
conductor FRLS PVC insulated stranded wire of green colour for earth
continuity of following size,(E) in existing pipe,(b) 2 wire 2.5 sq. mm
providing and erecting Mains with 1.1 KV grade FRLS PVC insulated ISI
marked stranded Copper conductor wire in following type of pipe to be
110 erected in / on wall / ceiling with 2.5 sq. mm copper conductor FRLS PVC 108.00 82.82 Mtr.
insulated stranded wire of green colour for earth continuity of following
size,(E) in existing pipe,(a) 2 wire 4 sq. mm
providing and erecting Mains with 1.1 KV grade FRLS PVC insulated ISI
marked stranded Copper conductor wire in following type of pipe to be
111 erected in / on wall / ceiling with 2.5 sq. mm copper conductor FRLS PVC 50.00 116.15 Mtr.
insulated stranded wire of green colour for earth continuity of following
size,(E) in existing pipe,(b) 2 wire 6 sq. mm
DESCRIPTION OF ITEM QTY RATE Per Unit
providing and erecting Mains with 1.1 KV grade FRLS PVC insulated ISI
marked stranded Copper conductor wire in following type of pipe to be
112 erected in / on wall / ceiling with 2.5 sq. mm copper conductor FRLS PVC 58.00 148.47 Mtr.
insulated stranded wire of green colour for earth continuity of following
size,(E) in existing pipe,(g) 4 wire 4 sq. mm
providing and erecting Mains with ISI marked, 1.5KV grade electrolyte multi
stranded, annealed copper conductor with heat resistant PVC insulated
conforms to IS 694, IEC - 227 erected in existing pipe of following size
(Specifically for control panel, relays, power switchgears, motor starters &
control wiring) with required size of copper lugs, nuts and bolts if
required.(d) One wire 4.00 sq. mm
providing and erecting Mains with ISI marked, 1.5KV grade electrolyte multi
stranded, annealed copper conductor with heat resistant PVC insulated
conforms to IS 694, IEC - 227 erected in existing pipe of following size
(Specifically for control panel, relays, power switchgears, motor starters &
control wiring) with required size of copper lugs, nuts and bolts if
required.(f) One wire 10.00 sq. mm
Supplying and erecting Flexible PVC insulated multi strand multi core 1.1 kv
115 grade ISI marked copper wires of following size to be erected as directed.(e) 120.00 44.44 Mtr.
1.50 Sq.mm 3 core round PVC sheathed
Supplying and erecting Flexible PVC insulated multi strand multi core 1.1 kv
116 grade ISI marked copper wires of following size to be erected as directed.(c) 75.00 21.21 Mtr.
1.00 Sq.mm 2 core round/ flat PVC sheathed
Supplying & erecting approved make LAN cable of following size in existing
pipe as per direction,[C] CAT -
Providing & erecting Switch board for Computer or electric apparatus
consisting of following modular type accessories mounted with PVC /
Metallic concealed/open box with single mounting base frame covered with
118 textured/metallic /white front plate,modules erected with necessary 4.00 1081.71 No.
connections as directed
1 no. 6A/16A universal plug-switch combined.
3 nos. 6A Switch
3 nos. 6A 5 pin Plug ,For Modular Type Accessories ,Cat. III
119 Decorative call bell Ting-tong box type 250 volts complete erected 2.00 68.68 No.
Supplying and erecting LED indoor fittings with LEDs of wattage 0.2 Watt
to 0.5 Watt assembled on single MCPCB, with housing used as a heat sink
shall be made of thick sheet Steel conforming to IS: 513/CRCA/ aluminium
die cast powder coated and high U.V. & corrosion resistance with diffuser
with company mark/name 160V to 270V, Power Factor more than 0.95,
Luminaire efficacy> 85 lumens/watt ,LED
LED driver efficiency > 85 %
( fitting required LM-79 & LM-80 Certificates)(NOTE: Below description
have shown ranges of Wattage capacity of LED fittings.The Engineer
incharge may select any wattage capacity between the ranges shown.),(A)
Tube Light with integral driver,(ii) 20 Watts, Surge - 2KV,IP-20,
conventional 4 feet,Cat-lll
Supplying and erecting led lamps with following wattage capacity of 220 to
240 voltage, minimum 15000 burning hours life, 500 V in built-surge
protection,Polycarbonate diffuser, mounting suitable for E14 / E27 / B22
lamp holders, pf >= 0.5(A) LED Lamps integral type, with PC diffuser
suitable LAMP holder,(ii) 8 watts ,Cat-III
DESCRIPTION OF ITEM QTY RATE Per Unit
Supplying and erecting LED street light / Flood light fittings with High
power White LEDs wattage of 3 Watt and above assembled on single
MCPCB, efficiency more than 130 lm/w and corrosion free High pressure die
cast aluminum housing with smooth finish powder coated and heat sink
extruded aluminium with diffuser and Polycarbonate optics/ lenses, with
toughened glass with company mark/name engraved or embossed 160 to
V,Power Factor more than 0.95, THD < 10 %, CCT 3000 K to
122 5700K,Uniformity ratio >0.45, Luminaire efficacy> 100 lumens/watt . LED 10.00 4997.48 No.
driver efficiency > 85 %.( fittings required LM-79 & LM-80
certificates)(NOTE: Below description have shown ranges of Wattage
capacity of LED fittings.The Engineer incharge may select any wattage
capacity between the ranges shown.)(A) Street Light (IP-65), Surge
protection -4KV integral and ,Light must have 440VAC line supply with
over-voltage protection.,(ii) 48 to 60 Watts,Cat-lll
providing and erecting Miniature circuit breaker single pole 0.5A to 2A
123 system and having breaking capacity 10 KA to be erected in existing box. 10.00 270.68 No.
confirming to IS 8828/1996 with ISI Mark
providing and erecting Miniature circuit breaker single pole 6A to 25A
suitable to operate on 240 V A.C. system and having breaking capacity
KA to be erected in existing box. confirming to IS 8828/1996 with ISI Mark
Providing & erecting 240 V MCB double pole switch for lighting Load (B
125 Curve) having 10 KA breaking capacity & confirms to IS : 8828 in existing 4.00 278.76 No.
box having following capacity (A) 6 to 32 Amp.
Providing & erecting 240 V MCB double pole switch for motor & inductive
load (C Curve) having 10 KA breaking capacity & confirms to IS : 8828 in
existing box having following capacity ,(A) 6 to 32 Amp. Cat.III
Sheets steel powder coated enclosure suitable for incorporating One/Two
Providing and erecting Sheet Steel powder coated MCB distribution board -
flush / surface mounted fitted with busbar, neutral link, earth bar and DIN
rail, Conforms to IS 8623-1 & 3, IEC 61439-1 & 3 without MCB to house
128 appropriate nos. of MCBs.(The DBs should be used of same company of 1.00 1152.41 No.
MCB to be used) suitable for (A) single phase incoming and horizontal
single phase outgoing (b) sheet steel double door,(ii)8 way (IP-43)
Providing and erecting Sheet Steel powder coated MCB distribution board -
flush / surface mounted fitted with busbar, neutral link, earth bar and DIN
rail, Conforms to IS 8623-1 & 3, IEC 61439-1 & 3 without MCB to house
129 appropriate nos. of MCBs.(The DBs should be used of same company of 1.00 1492.78 No.
MCB to be used) suitable for (A) single phase incoming and horizontal
single phase outgoing (b) sheet steel double door,(ii)12 way (IP-43)
providing and erecting Approved make RCCBs conforming to IS: 12640 and
having sensitivity of 30 mA and Short Circuit withstand capacity of 10 KA
and suitable for operation on single phase 240 V,50Hz. having characteristic
of quick action & tripping with all advance feature & do not incorporate any
electronic component. for following Max. rating erected as directed (i)
Amps.DP Cat-III
Providing & erecting Medium Voltage Danger Notice Board sticker as per
131 language suggested by engineer incharge of standard size as per IS-2551 2.40 26.26 No.
DESCRIPTION OF ITEM QTY RATE Per Unit
Supplying & erecting in earthpit of minimum bore dia. 225mm size
approved make Safe Earthing Electrode consisting Pipe-in-Pipe Technology
as per IS 3043-1987 made of corrosion free hot dipped G.I.Pipes having
Outer pipe dia of 80 mm having 80-200 Micron galvanising, Inner pipe dia
of 40 mm having 200-250 Micron galvanising, connection terminal dia of
14 mm with constant ohmic value surrounded by highly conductive
132 compound with high charge dissipation suitable for following type of 2.00 4591.46 No.
applications with chamber and heavy duty cover.(approved make OEM has
to submit test certificate including value of earth resistane of installation.(a)
For Electrical Installation up to 440V in normal soil
Length of pipe - 1 Mtr
Back filling compound - 1 Nos Bag of 15 Kg.
Supplying & erecting in earthpit of minimum bore dia. 225mm size
approved make Safe Earthing Electrode consisting Pipe-in-Pipe Technology
as per IS 3043-1987 made of corrosion free hot dipped G.I.Pipes having
Outer pipe dia of 80 mm having 80-200 Micron galvanising, Inner pipe dia
of 40 mm having 200-250 Micron galvanising, connection terminal dia of
14 mm with constant ohmic value surrounded by highly conductive
133 compound with high charge dissipation suitable for following type of 2.00 5760.03 No.
applications with chamber and heavy duty cover.(approved make OEM has
to submit test certificate including value of earth resistane of installation.[b]
For Electrical installation up to 11 KV located in other than normal soil
i.e. Soft Rock, Marshy Soil etc.
-Length of Pipe : 2 mtr
-Back filling Compound :1 no. Bag of 25 Kg
134 Providing and erecting Annealed bare Copper wire 8 to 16 SWG. 2.00 794.87 Kg.
Providing and erecting Pipe type earthing having 150 cms.long and 2.5 cms.
135 dia. galvanised iron pipe with coupling and buch buried in specially prepared 5.00 368.65 No.
earth pit complete with necessary 8 SWG earth wire.
136 For using salt and charcoal / coke as required for pipe type earthing 4.00 171.70 No.
Providing and erecting XLPE (IS:7098)(I)-88 ISI armoured cable multistrand
/ Solid Aluminium conductor for 1.1 KV. to be laid on wall with necessary
clamps or in existing trench / pipe of following size of cables.(B) 4 core
Providing & laying approved make Double walled corrugated pipes (DWC)
of polyethylene(conforming to IS 14930 II )with necessary connecting
138 accessories of same material at required depth in existing trench for laying 120.00 62.62 Mtr.
of cable. below ground / road surface for enclosing cable (A)50 mm outer
Providing & laying approved make Double walled corrugated pipes (DWC)
of polyethylene(conforming to IS 14930 II )with necessary connecting
139 accessories of same material at required depth in existing trench for laying 80.00 95.95 Mtr.
of cable. below ground / road surface for enclosing cable (C)90 mm outer
Providing and, fixing heavy duty flange type brass double compression type
cable gland with rubber ring for PVC insulated armoured cable complete
with out going tails, insulating tape etc for following size of cables. (D) 3 &
1/2 core 95 Sq. mm
Solder less crimping type Aluminium lugs conforming to IS suitable for
cable of following size evenly crimped with high pressure tool & connected
to switchgear terminals with brass/cadmium plated nut bolts in an approved
manner. (B) 10 Sq.mm.
Providing & erecting Approved make Power Saving 50 Watt Ceiling Fan
with double ball bearing ISI mark with Condenser 230 volt A.C. 50 Hz
142 1200 mm sweep complete having 3blades with aluminium blades with , 30.00 1948.29 No.
canopy & 30 cm. down rod erected with earthing.(Make shall be approved by
Engineer in charge))
Supplying & erecting fan hook box of 10 mm M.S. round bar bounded to
the RCC bars up to 50mm length each side and pierced through a 16 Gauge
M.S. box / Heavy Duty PVC box complete erected concealed in Ceiling with
necessary finishing.
DESCRIPTION OF ITEM QTY RATE Per Unit
Providing 2.5mm.thick laminated acrylic sheet to cover the fan hook or Fan
Supply of approved make FRP Pole having following specifications: FRP
Light Pole made by CNC filament winding machine using thermoset resin
polyester/epoxy resin system) having minimum 62% glass content. The pole
should be in one piece and tapered round in shape, having smooth finish and
should be totally free from corrosion as well as non conductive & shock
proof Pole should be provided with FRP Anchor Base and it should be
heavy duty, or MS Material duly painted with Epoxy paint. Pole should be
flame retardant as per IS 6746. Resin used shall be UV resistance and
pigmented. A highly weather resistant polyurethane coating shall be applied
to the pole after applying suitable primer system that ensures proper adhesion
of the paint. Minimum coating thickness shall be 80 to 100 micron.
145 Deflection of the pole shall not exceed more than 10% of the length of pole 10.00 8252.71 Each
for the given load“ Pole should be generally made as per the dimensional
data, performance criteria and some interchangeability features of poles as
per standard ANSI C 136.20 latest version or ASTM D 4923/01 including
cable termination box with necessary accessories . The size of pole and type
of installation with foundation as per manufacturer details and site
requirement are as below .(3) Suitable for direct grouting & Single arm
Bracket. [D] Overall length of 5 Mtr. Average Thickness: 7mm.
Top/ Bottom OD Dia: 90/145 mm ± 3mm approx. approx. Weight of Pole
Providing Aluminium arm bracket of having 2 sets of suitable SS304
146 hardware for fixing the brackets & spread of 1.2 Mtr (Suitable for 89 to 114 10.00 2234.12 No.
mm pole top dia) (A) Single arm bracket
Providing Aluminium arm bracket of having 2 sets of suitable SS304
147 hardware for fixing the brackets & spread of 1.2 Mtr (Suitable for 89 to 114 4.00 3450.16 No.
mm pole top dia) (B) Double arm bracket bracket
Supplying & erecting approved make SMC press moulded composite FRP.
loop-in, loop-out approx. 2mm thick box complete with Bakelite connector
strip 5way(3P+N+E),DIN rail for mounting mob & hinged doors as per
148 requirement having locking arrangements with mounting clamp with nuts, 10.00 515.10 No.
bolts & washers suitable for erection on pole with cable clamps& earth bolt
of following size of box. (B) 250mm x 200mm x 100mm [deep]
Providing 1:2:4 cement concrete foundation & 70 % PCC from bottom
including excavation for the pole of size 45 x 45 x 100 cm. Deep in below
ground level with plinth of 45 cm x 45 cm (or 45 cm dia x 45 cm) high upper
ground level with necessary curing and finishing in approved manner.
( for 4 & 6 mtr pole)
Supplying & erecting Amplifier having following specification:
Power Output :250W (RMS) (300W Max.)
inputs : 6 Misc. & 2 Aux.
frequency Response :50-1500HZ I3db
150 Tone Controls :Cut & Boost type 2.00 11298.87 Each
LED Meter :5 LED Arrays
The amplifier suitable to operate 240V A.C.& 24volt D.C. (Battery) with
automatic changeover from AC to Battery operation, duly protected by
wrong Battery Polarity connections. [[Approved by Competent Authority i.e.
not Below the rank of Executive Engineer ]
Supplying & erecting recess wall mounting speaker with 5W rated input
power 3.3 K. Ohms / 3W impedance, 100 - 10000 Hz frequency response
151 with 6 inch dia. cone type 8 ohms speakers duly fitted in ABS plastic cabinet 5.00 591.86 No.
of colour match with wall or ceiling of following size. (b)Square shaped
x 260mm size speaker
DESCRIPTION OF ITEM QTY RATE Per Unit
Supplying, installing and testing approved make microphone for All purpose,
with frequency response of 100 - 11000 Hz, having sensitivity 2.2mv / Pa &
impedance 500 Ohms (LO- Z) supplied with quick detachable holder, 6 mtr
twin core cable & 3 pin XLR connector. [[Approved by Competent
Authority i.e. not Below the rank of Executive Engineer ]
Providing and erecting water cooler having storage capacity 80Ltr. & cooling
capacity 40 Ltr.per hour @ an ambient temp of 45˚ C. The outlet temp. of the
water should drop by 15˚ C within a hour, The water cooler should be
153 comprising of hermetically sealed compressor, fan motor, condensing unit, 2.00 41342.33 No.
water tank surrounded by evaporating coil, thermostats, relay etc. complete
with necessary inlet & outlet connection. The body of water cooler will be
made from Stainless Steel. ◦
Supplying & erecting 5 stage single reverse osmosis water purification
system with M.S. powder coated frame, prefilter housing with 'O' ring
presediment filter GAC filter, carbon filter suitable buster DC pump capacity
154 80 psi, mention with 40 psi inline type post carbon filter auto low & high 2.00 13053.24 No.
pressure switches with following size of storage tank & LPH capacity &
erected as directed ,[B] 25 Ltr / Hr with 30 Ltr. Storage Tank
Providing ABC Type Fire Extinguisher 6 Kg Isi Marked All Required
155 Fitting Accessories.(M.R.) 1.00 4242.00 No.
DESCRIPTION OF ITEM QTY RATE Per Unit
Providing Co2 Type Fire Extinguisher 4.5 Kg Isi Marked All Required
156 Fitting Accessories.(M.R.) 1.00 7878.00 No.
I / WE am / are willing to carry out the work at ________ % above / below (percentage should be written in figures and
Estimated amount put to tender __________
Deduct / Add: _____ % below / above __________
Net Amount __________
(Please strike out which ever is not applicable)
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
05-Building-SpecificationBook.pdf
ANNEXURE-FIRE.pdf
2017-02-15_TMT Lap Length Mesurement GR.pdf
ELECTRICAL_SPECIFICATIONS_GRS.18.05.2021.pdf
GR-Royalty.pdf
Technical Specification of Green chalk board.pdf
TUBEWELL SPECIFICATIONS_R1.pdf
DRW ACR 2_NEW DESIGN -22-23-2_SOE 4 ROOM G+1 22-23(2+2).pdf
pdf • 0.99 MB
DRW ACR 2_NEW DESIGN -22-23-2_SOE 5 ROOM G+2 22-23 (2+2+1).pdf
pdf • 1.18 MB
DRW ACR 1_NEW DESIGN -22-23-1_SOE 1 ROOM G.F. 22-23 (1+0).pdf
pdf • 0.76 MB
DRW ACR 1_NEW DESIGN -22-23-1_SOE 2 ROOM G+1 22-23(1+1).pdf
pdf • 1.09 MB
DRW ACR 1_NEW DESIGN -22-23-1_SOE 3 ROOM G+1 22-23(2+1).pdf
pdf • 1.05 MB
DRW ACR 3_NEW DESIGN -22-23-3_SOE 6 ROOM G+2 22-23 (2+2+2).pdf
pdf • 1.35 MB
DRW ACR 3_NEW DESIGN -22-23-3_SOE 7 ROOM G+2 22-23 (3+3+1).pdf
pdf • 1.36 MB
DRW ACR 4_NEW DESIGN -22-23-4_SOE 8 ROOM G+2 22-23 (3+3+12.pdf
pdf • 1.44 MB
SPECIAL CONDITION - COLOR.pdf
ANNEXURE-SPECIFICATION 1-2-Make list and Testing.pdf
BOQ-8010.pdf
R-8010.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .