Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.1 LAccepted-AOC 179 THE MALL AMBALA CANTT 133001 HR | AMBALA | HARYANA | 133001 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹31.7 L+₹1.0 L (3.31%)Rejected-Finance 27 19 F F D BLOCK CHATTARPUR EXTN SOUTH WEST DELHI DELHI 110075 | SOUTH WEST DELHI | DELHI | 110075 | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | L3₹33.7 L+₹3.0 L (9.80%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 4 | L4₹38.0 L+₹7.3 L (23.7%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 5 | L5₹38.9 L+₹8.2 L (26.7%)Rejected-Finance 256 MODEL TOWN AMBALA CITY 134003 | AMBALA CITY | AMBALA | HARYANA | 134003 | L5 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
5 Dec 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF AMBALA
GE AF AMBALA
GE AF/AMB-T-63/2023-24 UPGRADATION OF CERTAIN MAP PHASE-I QTR TO MAP PHASE-II SPECIFICATION AT RR LINE AT AF STN AMBALA UNDER GE (AF) AMBALA
2023_MES_627017_1
GE AF/ AMB-T-63/2023-24
Open Tender
Civil Works
Item Rate
180 days
GE AF AMBALA
ALL AS PER NIT AND TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE AF AMBALA
₹90,000
Yes
30 Jan 2024
6 Nov 2023
12 Dec 2023
6 Nov 2023
5 Dec 2023
21 Nov 2023
Amount
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises to a distance not exceeding 500 mtr complete all as specified and directed.
Material and labour for coloured, non- skid joint free,edge cut, ceramic tiles,1st quality, 7 to 8 mm thick ,square/ rectangular, area of each tile exceeding 0.11 but not exceeding 0.18 Sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface over and including 15mm thick screed bed or bedding layers in Cement Mortar 1:4, complete all as specified and directed.
Material and labour coloured, non- skid joint free,edge cut, ceramic tiles,1st quality, 7 to 8 mm thick ,square/rectangular, polished, area of each tiles exceeding 0.18 but not exceeding 0.38 Sqm in floors, set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface over and including 15mm thick screed bed or bedding layers in Cement Mortar 1:4, complete all as specified and directed.
All as per BOQ srl item No 3.00 (here-in-above) but in vertical surfaces with backing coat of 10 mm thick other than fair faces of wall in CM 1:4 complete all as specified and as directed.
Material and labour for glazed ceramic coloured tiles of size 300x450x7mm thick on vertical surface as in skirting/dado set and jointed in neat cement slurry & pointed in white or coloured cement to match over 10mm thick rendering in CM 1:4 on brick / concrete walls complete all as specified and directed
Dismantling of stone slabs/ floor and wall tiles of any description or thickness as in floors, aprons etc laid and bedded in any mortar including rubbish off the premises to a distance not exceeding 500 mtr complete all as specified and directed.
M&L for 16 -18 mm thick Udaipur green stone slab as in shelves , over cooking platform ,machine cut bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of Udaipur green stone including grinding and poshing laid over 20mm thick screed bed in cement mortar 1:6 including bull nosing of edges and gas pipe hole up to bottom of slab complete all as specified and as directed .
Taking up or down steel water tubing and connections for refixing or removal from site for 15 mm bore pipe complete all as specified and directed.
Taking up or down steel water tubing and connections for refixing or removal from site for 20 mm bore pipe complete all as specified and directed.
Supply and fixing galvanised mild steel water tubes 15 mm bore, medium grade, galvanised with all fittings and fixed complete to wall and ceiling or laid in floor including cutting chasing for concealed whereas required complete all as specified and as directed.
Supply and fixing galvanised mild steel water tubes 20 mm bore, medium grade, galvanised with all fittings and fixed complete to wall and ceiling or laid in floor including cutting chasing for concealed whereas required complete all as specified and as directed.
Taking down chowkhats or frames n.exc 1.5 sqm each with shutters without taking off shutters from the frame and removing from site, including cutting holes for taking out hold fasts and making good disturbed portion in cement mortar 1:3, complete all as specified and as directed
Taking down chowkhats or frames exc 1.5 but n.exc 4 sqm each with shutters without taking off shutters from the frame and removing from site, including cutting holes for taking out hold fasts and making good disturbed portion in cement mortar 1:3, complete all as specified and as directed
Taking down shutters only of any description area exc 1.00 sqm but not exc 2.00 sqm complete all as specified and directed.
S&F solid PVC door frame of size 50x47mm made out of 5mm thick plain/wooden grain printed coloured PVC sheet reinforced with MS square tube all as per specifications and drawing given in SSR Part-I 2009 all as per manufacturer's instructions and making good the disturbed surfaces complete all as specified and as directed
S&F factory made solid PVC moulded door shutter (with wood free EPS), 28 to 30mm thick (styles), with 2, 4, 6 raised panel design with 2mm thick moulded PVC sheet on the front and 2mm thick coloured PVC sheet (tint as approved) on back faces and fixing in frame at site all as shown in and specified in MES Schedule 2020 & 2009 complete all as specified and as directed
S&F flush shutters solid core construction with block board core and plywood face panels commercial type on both sides 30 mm thickness complete all as specified and directed.
Preparation of new wooden surfaces of any description over 10 cm width or girth & applying two coats synthetic enamel paint over a coat of pink primer complete all as specified and directed.
S&F powder coated aluminium anodised window(Three track sliding window, 02 shutters with glass and 01 shutter with wiremesh) made out hollow aluminium as mentioned below. Each shutter shall have 01 No. aluminium handle of 75mm size and 02 Nos aluminium tower bolt 150mm long. Window shall be glazed with 4.00mm thick tinted glass fixed with glazing clips, rubber beading and anodized aluminium beading and stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm fixed with tinned tacks or stainless steel wire staple etc complete all as specified and as directed. Chowkhat bottom section size : 50.3mm X 26.0mm, 1.20mm thick Chowkhat top & sides section size : 50.3mm X 15.0mm, 1.00mm thick Shutter top & bottom rail section size : 101.60mm X 44.45mm, 1.50mm thick Shutter inner lock rail section size : 37.5mm x 15.0mm, 1.50mm thick Shutter side mid rail section size : 37.5mm x 15.0mm, 1.36mm thick Note :- (i) The weight of Aluminium sectons shall not be less than 0.55Kg/RM. (ii) Minimum thickness of anodization shall be 15 micron. (iii) The door/window shall be as per drawings/directions of Engineer-in-charge and drawing may be reffered from GE office.
S&F powder coated anodised aluminium grill of approved design/pattern, mesh size 100mm x 100mm withh the help of glazingg plate & aluminium bars of 8mm dia using 'U' shape channel 25mm x 12mm, fixed to aluminium frame work complete all as specified and directed.
Roughening surface of old concrete floor by picking sweeping clean and washing down with water to remove dust etc and brushing neat cement slurry @ 3.0 Kg/Sqm complete all as specified and as directed
M & L for rough cast plaster incl 15 mm thick CM 1:3 on brick work or concrete surface complete all as specified in SSR Part -1 clause 14.22 complete all as specified and as directed . Note:Rough cast plaster finish shall be as follows :- After applying the under coat cement mortar 1:3 and while it is still in plastic state the rough cast mixture consisting of crushed stone or fine gravel aggreagte ( Which is generally of size between 6 to 12 mm depanding on the texture required mixed with coarse sand and cement in the ratio of 1:1:1 shall be applied and finished even . The mix of cement and sand shall be made slightly wetter than normal for rendering to ensure the larger aggregate are throughly covered.
Material and labour for machine cut Kota stone slab/tiles 20-25 mm thick, minimum size 30cmx 45cm as in flooring, laid over and including screed bed 20 mm thick in cement mortar 1:6 set and jointed with grey cement slurry or with adhesive as per manufacturer's instructions mixed with pigment to match the shade of the slab including rubbing and granite polishing achieve mirror finish complete all as specified and as directed.
Material and labour for machine cut Kota stone slab/tiles 20-25 mm thick, on vertical surface as in skirting/dado /steps riser/pillars etc, laid over and including rendering 10 mm thick in cement mortar 1:4 set and jointed with grey cement slurry or with adhesive as per manufacturer's instructions mixed with pigment to match the shade of the slab including rubbing and granite polishing achieve mirror finish complete all as specified and as directed.
M & L for Dismantling of brick work built in cement mortar including all quoins, pillars etc but excluding ashlar facings, dressed stone work and precast articles and rubbish off the premises to a distance not exceeding 500 mtr complete all as specified and as directed.
Material and labour for Brick work with sub class B bricks of old size, straight or curved on plan exc 6 m mean radius, built in cement mortar 1:6 complete all as specified and as directed.
Material and labour for Brick work straight or curved on plan exc 6 m mean radius, built in cement mortar 1:6 using old bricks retrieved from BOQ srl item No 25.00 hereinbefore after cleaning and washing complete all as specified and as directed.
Material and labour for Brick work with sub class B bricks of old size, straight or curved on plan to any radius in half brick thick wall, built in cement mortar 1:4 complete all as specified and as directed.
Use and waste of form work to chajjas, fins, facia and similar works for rough finished surfaces of concrete complete all as specified and as directed.
Demolition of RCC, of any description and in any position inluding cutting of reinforcement to facilitate demolition and rubbish off the premises to a distance not exceeding 500 mtr complete all as specified and directed.
Material and labour for RCC 1:2:4, type B-1,nominal mix (using 20 mm graded mechanically crushed stone aggregates) as in fins, fascia louvers, parapet and railing complete all as specified and as directed.
Material and labour for Mild steel TMT bars ,Fe 500 D, 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
Supply and fixing vitreous china squatting pan ,Orissa pattern, 580mmx440mm, white, with and including PVC ‘P’ or ‘S’ trap front or back inlet with integral foot rests excluding flushing cistern and flush pipe including providing lime concrete bedding and making good to floor complete all as specified and directed.
Supply and fixing in repair PVC low level flushing cistern, white, valveless syphonic action type 10 litres capacity with inlet, ball valve, float and handle including PVC flush pipe 32 mm dia with bend and a pair of mild steel angle iron brackets of suitable size including making necessary connections to water supply pipe line and WC, complete all as specified and as directed.
Supply and fixing in repair sink made of stainless steel 1.00 mm thick steel sheet, kitchen or laboratory with plug & chain, waste coupling, washers and 32 mm bore PVC waste pipe including bedding in cement mortar to dwarf wall or including fixing cantiliver MS/PVC brackets and connecting union to pipe over all size 495 mmx420mm bowl size 410x330x 160mm complete all as specified and as directed..
Supply and fixing in repair stainless steel plate rack of size approx 750x 600x 250mm made out of 1.0 mm thick steel sheet complete all as specified and as directed.
Dismantling old unserviceable RCC/PVC water tank of capacity exc 250 but n. exc 500 ltrs capacity including supply and fixing PVC water storage tank of 500 ltrs capacity HDPE double layered , cylindrical type fixed and hoisted in position on roof at any height complete with inlet/outlet of 20mm GI pipe connection including locking arrangement with 20mm ball valves high pressure with epoxy coated aluminium rod and high density plastic ball fixed as in repairs complete all as specified and directed.
Supply and fixing in repair vitreous china wash hand basin ,oval type, white, of size 630X450mm including 32mm bore PVC waste pipe and CP waste fitting and a pair of mild steel angle iron brackets of suitable size fixed in counter slab complete all as specified and as directed.
Supply and fixing in repair 15 mm dia pillar tap , fancy type, brass chromium plated with capstan head chromium plated screwed down high pressure with or without lettered “hot' or 'cold” with long screwed shank and flynut screwed complete all as specified and directed.
Supply and fixing in repairs fancy type stop valve/angle valve cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipes of 15mm bore complete all as specified and directed.
Supply and fixing 15mm dia stop valves cast copper alloy chromium plated (Concealed type) fancy type long shank and cup with capstan head and cup screwed both ends for iron pipe or for union including cutting chases for concealing after taking down valve as existing at site complete all as specified and as directed.
S&F in repair for 20mm dia Gun-metal, globe or gate valves, with iron wheel head, screwed both end for iron pipe and fixed, complete all as specified and as directed.
S&F in repair for 15 mm dia Gun-metal, globe or gate valves, with iron wheel head, screwed both end for iron pipe and fixed, complete all as specified and as directed.
Supply and fixing in repair bib taps 15 mm bore, brass, chromium plated, fancy type, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and as directed.
Supply and fixing in repair brass Chromium plated shower rose, fancy type,suitable for 15 mm bore pipe with or without swivel joints any size including fixed to steel pipe or union complete all as specified and as directed.
Supply and fixing brass chromium plated tubular towel rail 20mm dia ,fancy type, 60cm long,superior quality , between flanges fixed to wall with brass CP screws after taking down/out as existing at site complete as specified and directed.
Supply and fixing soap dish ,brass, chromium plated,size 160 x 160 x90 mm fixed with and including plugs with brass CP screws after taking down/out as existing at site complete all as specified and as directed.
Supply and fixing sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12 cm wide with chromium plated bracket guard and railing 60 cm long after taking down/out as existing at site complete all as specified and as directed.
Supply and fixing chromium plated grating 100mm dia fixed complete all as specified and directed.
Supply and fixing in repairs PVC connection 450mm long with 2 nos PTMT check nuts, suitable for 15mm bore complete all as specified and directed
Supply and fixing in repairs PVC connection 600mm long with 2 nos PTMT check nuts, suitable for 15mm bore complete all as specified and directed
Supply and fixing PVC (SWR) bends with access door ,any radius, for 110mm bore of pipe complete all as specified and as directed.
Supply and fixing PVC (SWR) branch piece,110mm bore single Y , equal or unequal complete all as specified and as directed.
Supply and fixing PVC (SWR) gully trap 125x110 mm ,made of type-B pipes ,setting and jointing with solvent cement complete all as specified and as directed.
Supply and fixing UPVC floor trap 75mm dia plain with PVC grating,type-B pipes including jointing to waste pipe with solvent cement complete all as specified and as directed.
Demolition and breaking up drain/ water pipes of AC/RCC/PVC of 100/75mm bore including all fittings etc complete all as specified and as directed.
Supply and fixing PVC (SWR) pipe 110mm bore single socketed in any length with rubber ring joints, laid in trenches or in floors, fixed to wall with suitable size FI clamps of size 25mmx3mm, complete all as specified and as directed.
Taking down cement plaster on brick or stone walls, etc including racking out joints, hacking for key, scrubbing down with water including removal of debries to distance n.exc 500 mtr complete all as specified and directed.
Material and labour for rendering 15 mm thick in CM 1:6 finished even and smooth without using extra cement on fair faces brick or concrete surfaces complete all as specified and directed.
Material and labour for rendering 15 mm thick in CM 1:4 mixed with WPC @ 2 % by weight of cement finished even and smooth without using extra cement on fair faces brick or concrete surfaces complete all as specified and directed. Note : WPC shall be measured and paid separately as supply only.
Material and labour for rendering 5 mm thick in CM 1:3 on the soffits of slab/chajjas/sunshade etc finished even and smooth without using extra cement complete all as specified and directed.
Supply only integral water proofing compound complete all as specified and as directed.
Demolition of plain cement concrete,un-reinforced, in ground floor and paving not exceeding 15 cm thick below or above ground floor including rubbish off the premises to a distance not exceeding 500 mtr complete all as specified and directed.
Demolition of plain cement concrete, un-reinforced of any description and in any position not otherwise specifically provided for including rubbish off the premises to a distance not exceeding 500 mtr complete all as specified and directed.
Material and labour for PCC 1:4:8, type D-2 (using 40mm graded mechanically crushed stone aggregates), 100 mm thick as in sub base of floors complete all as specified and directed.
Material and labour for 25 mm thickness PCC 1:2:4, type B0, (using 12.5 mm graded mechanically crushed stone aggregates) as in floor finished even and smooth without using extra cement complete all as specified and directed.
Material and labour for 75mm thick PCC (1:3:6), type C-1, (using 20mm graded mechanically crushed stone aggregate) as in plinth protection finished even and smooth without using extra cement with & including 10mm wide, 30mm deep joints at the rate of 3.00 mt centre to centre and at every turning & filling the joints with bitumen & sand mixture complete all as specified and as directed. Notes :- (i) The unit rate quoted shall be deemed to include for providing the concrete in alternate bays not exceeding 3 Mtrs length,12 mm wide. (ii) 50 mm deep joints between the bays shall be provided which shall be filled with mastic filling with hot bitumen 85/25 grade and 1:2 mix volume.
Material and labour for for carrying out water proofing treatment of sunken floor as under:- (i)The concrete/ wall surface shall be cleaned throughly of all laitance , loose particles, dust , grease etc. any friable unsound area shall be chipped, cleaned and there after pre-welted to a saturated surface dried conditions. (ii) In case of potholes , superficial cracks found , the same shall be repaired with polymer modified mortar 1:3 ( 1 cement and 3 coarse sand )using Dr fixit pidicrete URP 301/Sikka latex or equivalent in Asian paints/ Fosroc as admixture @ 10% of cement content and the same shall be applied on vertical area after removing of plaster upto 2 ft height (iii)On the prepared surface , apply a primer coat of Sika latex / Dr. fixit pidicrete URP 301 or equivalent in Asian paints/ Fosroc modified cement slurry 1:4:8 (1 admixture : 4 water : 8 cement) , after prewetting the substrate @ 2 kg/sqm . (iv) The surface thus prepared shall dampen upto saturation and apply two coats of sika top seal 107 or equivalent in Dr fixit pidilite/Asian paints/Fosroc ,acrylic modified water proofing coating on the entire area @1.5 kg/sqm (each coat) second coat shall be applied after 6-8 hrs after the first coat and in the direction right angle to the previous coat . the water proofing should be taken to a vertical height of minimum 600 mm above . (v) Apply open woven glass fiber mesh of sika Fab 1 or equivalent in Dr fixit pidilite/Asian paints/Fosroc, 150 mm wide strip over the PCC benching (Gola) whilst the first coat is wet and then apply second coat . cure the hydrosent application ( Minimum 6-8 hrs drying) for a minimum 3 to 5 days .
(vi)Apply a protection layer of 10 mm thick plaster made of 1:4 cement sand mortar admixed with integral water proofing compound Sika plastocrete plus/ Dr fixit pidilite LW plus or equivalent in asian paints/ Fosroc @ 200 ml/bag of cement , applied over the water proofing coating . Note : The rate include the cost of demolition of existing floor , sub base , PCC/ hardcore filled under floor , removal of debris , removal and replacement of damaged CI/PVC pipes, floor,Nahani traps complete all as specified and directed.
M&L preperation of new plastered surface of ceiling and applying three coats of white wash on ceiling repairing with JK /Birla white putty complete all as specified and directed.
M&L preperation of old plastered surface of ceiling and applying two coats of white wash on ceiling repairing with JK / Birla white putty complete all as specified and directed.
Material and labour for two coats of 100% premium emulsion acrylic paint having VOC less than 50gm/litre and UV resistance as per IS 15489:2004 , alkali and fungal resistance , dirt resistance exterior paint of approved shade/tint(Company depot tinted),with silicon additives @1.43 Litre/10 Sqm over and including priming coat of exterior primer applied , on newly plastered surfaces of walls including preparation of surfaces repairing with JK / Birla white putty complete all as specified and as directed.
Material and labour for two coats of 100% premium emulsion acrylic paint having VOC less than 50gm/litre and UV resistance as per IS 15489:2004 , alkali and fungal resistance , dirt resistance exterior paint of approved shade/tint(Company depot tinted),with silicon additives @1.43 Litre/10 Sqm over and including priming coat of exterior primer applied ,on complete removal of existing treatment of old plastered walls including preparation of surfaces repairing with JK / Birla white putty complete all as specified and as directed.
Material and labour for two coats of Oil bound distemper of approved shade/tint over a coat of primer over JK/Birla white wall care putty of any thickness to achieve smooth finish on newly plastered surfaces of walls including preparation of surfaces complete all as specified and as directed.
Material and labour for two coats of Oil bound distemper of approved shade/tint repairing with JK / Birla white putty of any thickness to achieve smooth finish, on old treated plastered surfaces of walls including preparation of surfaces complete all as specified and as directed.
M&L for preparing of old treated steel / metal surfaces of any description over 10cm in width or girth and applying one coat of synthetic enamel paint, tint as approved complete all as specified and as directed
M&L for preparing of old treated wood / wood based surfaces of any description over 10cm in width or girth and applying one coat of synthetic enamel paint, tint as approved complete all as specified and as directed
Supply and fixing machine crafted box type cabinet for kitchen using 18-19 mm thick HDHMR board both side laminated with and including all necessary fitting and fixtures ( including handles, magnets and piano hinges) , 125mm s/s handles complete all specified and directed NOTE:- (i)Front area of box shall be considered for payment purpose. (i) Depth of box shall be equal to the width of cooking platform. (ii)Piano hinges shall be measured and paid seperately.
Supply only continuous (piano) hinges, mild steel, bright finish or electro-galvanised, width of flaps when open 40mm complete all as specified and as directed
S&F Stainless steel chromium plated peg set having 6 pegs for hanging of clothes of approved pattern shape and size complete all as specified and directed.
M&L PCC 1:5:10, type E2, (using 40 mm graded crushed stone aggregate) as in subbase of floor in any position and in any thickness , complete all as specified and directed by Engr-in-Charge.
S& F GI spout 40 mm dia medium grade to be embeded in sunken floor complete all as specified and directed.
M & L for Easing of door shutter, cupboars shutters , show cases including fixing of screw adjusting handle, knobs etc including taking down and refixing in the same opening complete all as specififed and directed
Supply and fixing fancy type MS curtain rod 20 mm bore ,coloured powder coated of approved shade with and including MS powder coated bracket knobs (two nos for each cut length), funnel on ends (two nos for each cut length) and suitable PVC rings of 1st quality after taking down/out rod as existing at site complete all as specified and as directed.
Supply and fixing butt hinges, medium weight cold rolled mild steel 100 mm size welded to angle iron frames or fixed with screws to wooden frames complete all as specified and as directed.
Supply and fixing aluminum anodised pressed handle, cast type ,150mm long, complete all as specified and as directed
Supply and fixing 200 mm long aluminum anodised barrel tower bolt , of extruded section complete all as specified and directed
Taking down carefully copper / Aluminium point wiring including (light, fan, socket or power complete fittings, such as switches, ceiling roses, pendant holders, Batten holders, shades conical fan regulators, light or power sockets etc) removing materials from site and making good disturbed surfaces of walls roofs etc complete all as specified and directed
Taking down carefully UNSV DB's including MCBs of of any size make, type and capacity and making good disturbed surfaces of wallls/roofs etc, complete all as specified and directed
M & L for Concealed point wiring complete with 1.5 Sqmm single core multistranded copper conductor PVC insulated and unsheathed cable 1100 volts grade drawn through and including non metallic rigid PVC conduit,medium grade minimum 19mm dia ISI marked and conduit accessories fixed concealed in wall/ceiling/roof etc with sunken type pressed steel/welded MS terminal boxes made out of 1.6 mm MS sheet, 3mm thick laminated sheath top cover for mounting of fittings,switches,sockets outlets,regulators etc complete including provisining of 1.5 sqmm PVC insulated unsheathed cable 1100 volt grade with multi stranded copper conductor to common earth and connected to earth dolly complete all as specified and directed
One light/fan point controlled by one switch 6 amp one way complete all as specified and directed
One bell point controlled by one switch 6 amp one way on same board with other switches or indepepent board one way complete all as specified and directed
One 3 pin socket 5 amp on the independent board complete all as specified and directed
One 3 pin socket on same board with other switches complete all as specified and directed
All as per Srl item No.90.00 here-in-above but one light point controlled by two-2 way switch complete all as specified and directed
All as per BOQ Srl item No.90.00 here-in-above but point wiring with 2.5 sqmm single core multi stranded copper conductor PVC insulated & unsheathed cable 1100 volt grade and 2.5 sqmm PVC insulated and unsheathed cable 1100 volt grade with multi stranded copper conductor for earth wire for 15/16 amp multi purpose socket combination point on independent board. complete all as specified and directed
M&L for switch piano flush type single pole, one way 5 amp, complete all as specified and directed
M&L for switch piano flush type two way 5 amp,complete all as specified and directed
M&L for switch piano flush type single pole, one way 15 amp complete all as specified and directed
M&L for socket outlet piano flush type 2 in 1, 3 pin 5 ampcomplete all as specified and directed
M&L for socket outlet piano flush type 2 in 1, 3 pin 5 &15 amp, complete all as specified and directed
S&F stepped type Electronic fan regulator flush type complete all as specified and directed
M&L for switch flush type bell push button 5 amp complete all as specified and directed
S&F bell Ding dong AC 230Volts single pole complete all as specified and directed
S&F ceiling rose 65x17mm of three terminals complete all as specified and directed
S&F incl taking down lamp holder,PVC/Polycarbonate type and back plate suitable for batten fitting complete all as specified and directed
S&F LED Lamp 7 watt B22 type complete all as specified and directed
S&F 1X18 watt wall mounted, new generation LED T-8 Retro fit for multipurpose application with LED Rod , made from extruded aluminium housing, polycarbonate diffuser including all fixing accessories & connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed by Engr in Charge.
S&F 1X10 watt wall mounted, new generation LED Batten fitting for multipurpose application with extruded aluminium housing with decorative end caps including all fixing accessories & connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed by Engr in Charge.
Supply and fix new generation energy saving 9/10 watt LED bulk head (porch light fitting) made of plastic housing with opal diffuser complete all as specified and directed by Engr in Charge.
Supply and fixing LED street light fittings 45 watts, input 110 volts to 240 volts, Provn of auto shut down on high voltages, life > 50000 Hrs, operating temp 1 degree to 50 degree, as per IP 65 , luminaries comprising of rectangular shape pressure Die cast aluminium housing with weather proof gasket for lamp and driver compartment with system wattage of 45 W =10% W & rated lumens of min 4500 lumens with 120 degree view angle , the driver must be constant current type having THD <10% and power factor >0.95 with short circuit protection , open circuit protection, reverse circuit protection, high voltage protection, protection against 10 KV high surges, the luminaire must have secondary optics with perfectly matched lenses for better light control and comply to IEC60598/IS10322 including 25 mm GI bracket of length 1.2 Mtr shape in bend with necessary fixing arrangement complete all as specified and directed .
Disconnecting electric connection and taking down carefully ceiling fans/walls fan/exhaust fan/Aircirculator fan any sweep and removing fan and fan blades to AGE E/M storeyard as directed by Engr-in-Charge
M &L for painting of c/fan with two coats of white synthetic enamel paint and marked MES No. by black permanent marker all as directed by Engr in Charge.
Supply & fix exhaust fans AC single phase 230/ 240 V of size 300 mm sweep (Steel body) with Blades, frame And louvers including making/widening of hole of suitable size along all fixing accessories
Fixing ceiling fan of any sweep to same site after repair/servicing including flexible cable from ceiling rose to fan complete all as specified and as directed by Engineer-in-Charge
Fixing exhaust fan of any size to same site after repair/servicing including flexible cable from ceiling rose to fan complete all as specified and as directed by Engineer-in-Charge
M&L for Making Hole for 200 MM Sweep plastic fan in suitable square/rectangle/circle shape in wall and making good damages complete all as specified and directed
Supply & fix exhaust fans AC single phase 230/ 240 V of size 200 mm sweep Made of sturdy engineering plastic with louver,shutter complete incluing making of hole/niche of suitable size along with all fixing accessories complete all as specified and directed
Supply and fixing metal plug and socket single pole and neutral with a two pin and earth plug and socket alongwith one single pole MCB of 20 Amp concealed in wall complete all as specified and directed
Taking down carefully copper / Aluminium wiring and removing materials from site as directed and making good disturbed surface complete all as specified and directed
M&L submain wiring with 2 runs of copper conductor PVC insulated unsheathed cable 1100 volt grade 4 sqmm drawn through PVC conduit medium grade ISI marked 25mm dia as per IS specification fixed concealed in wall/ceiling including conduit and conduit accessories and incl provn of PVC insulated 4 Sqmm multistranded copper conductor as earth continuity conductor connected to earth dolly all as specified including dismantling old and making good to the disturbed surface by plastering and two coat of distemper complete all as specified and directed. Note : Two runs of 4 sqmm cable alongwith one run of 4 Sqmm PVC insulated unsheathed copper conductor as earth wire, conduit and conduit accessories will be measured as one length.
M&L submain wiring iwith 2 runs of copper conductor PVC insulated unsheathed cable 1100 volt grade 6 sqmm drawn through PVC conduit medium grade ISI marked 25mm dia as per IS specification fixed concealed in wall/ceiling including conduit and conduit accessories and incl provn of PVC insulated 6 Sqmm multistranded copper conductor as earth continuity conductor connected to earth dolly all as specified including dismantling old and making good to the disturbed surface by plastering and two coat of distemper complete all as specified and directed. Note : Two runs of 6 sqmm cable alongwith one run of 6 Sqmm PVC insulated unsheathed copper conductor as earth wire, conduit and conduit accessories will be measured as one length.
S&F MCB DB TPN 4 Way vertical type factory made IP 43 protection class metal double door with Shrouded Neutral Bar & Pan assembly with connecting link complete including Provision for fixing one MCCB upto 125A. Note : MCCB will be measured and paid separately under respective items of sch A
S&F MCB DB SPN 8 Way factory made IP 43 protection class metal double door with 200 Amp rating bus bar 240/430V for fixing of MCBs/Isolators/RCCBs etc complete all as specified and directed
S&F in replacement MCCB Four pole 415 Volts, 100 amp 16 KA complete all as specified and directed.
S&F MCBs 240/415 Volts 10 KA finger proof terminal, C curve bi-connect termination, label holder, 35 mm² terminal capacity, insulated sliding shutter, large two position dolly, ISI marked to be fixed on DB complete all as specified and directed. Note : DB will be measured and paid separately under respective items of sch A
MCB SPN 40 Amps.
MCB SP 5 to 32 Amps
M&Lin replacement for earthing complete with galvanized steel earth plate electrode 600x600x6.3 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level,the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15cm on all side and including connected toand including galvanized earth lead wire 4.0 mm dia upto 7.5 mtrs long by means of nuts and bolts, check nuts and washers of GI and connected to earhing test point and earth dolly all as shown in electrical plate No 3 of MES SSR part I and testing on completion including necessary excavation and earth work in any type of soil,PCC(1:3:6)type C1 chamber,pre-cast RCC slab 50mm thic in cement concrete (1:2:4),type B1,reinforced with welded steel wire fabric or XPM,(weight not less than 4 Kg per Sqm) with cast iron frame,funnel with watering pipe 20mm dia medium grade,wire mesh and lugs,GI protection pipe,15mm dia,light grade,7.5 mtr long for protection of earth lead upto test point etc all as specified and as directed. Note : (i) Any variation in length of earth lead and protection pipe of earth lead shall be ajdusted through DO. (ii) On testing, if the desired earth resistance is not obtained, entire earthing shall be re-done by contractor till the desired earth resistance is obtained without accruing any extra cost to the government. (iii) The chamber shall be constructed atleast 1.5 mtr away from the earth electrode.
Disconnecting electric and water connection and taking down Geyser carefully and deposit to AGE E/M storeyard and refixing geyser at same location all as specified and directed by Engr-in-Charge.
Taking down carefully electric meter from the existing place , kept in safe custody and refixing the same after completing the work with suitable size of copper wire for necessary action from meter to DB and meter mounted on suitable size of wooden box complete all as specified and directed at site. Note:-(1) The Reading of Meter will be taken in presence of Barrack warden and BSO rep. (2) All Reading of meter shall be kept in safe custody.
KULWANT SINGH
Jai Bala Ji
Swami Enterprises
M/S SHANTI CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .