Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.1 LAccepted-AOC PARTH B 203 PATEL COLONY STREET NO 11 ROAD NO 3 JAMNAGAR 361 006 GUJARAT | JAMNAGAR | GUJARAT | 361006 | L1 | Accepted-AOC L1 | |
| 2 | L2₹30.6 L+₹3.7 L (13.6%)Rejected-Finance INS VALSURA JAMNAGAR | JAMNAGAR | GUJARAT | 360520 | L2 | Rejected-Finance Not Being L1 | |
| 3 | L3₹32.5 L+₹5.6 L (20.6%)Rejected-Finance INS VALSURA JAMNAGAR | JAMNAGAR | GUJARAT | 360520 | L3 | Rejected-Finance Not Being L1 | |
| 4 | L4₹33.2 L+₹6.2 L (23.1%)Rejected-Finance | L4 | Rejected-Finance Not Being L1 | |
| 5 | L5₹33.4 L+₹6.4 L (23.9%)Rejected-Finance | L5 | Rejected-Finance Not Being L1 |
Tender Value
₹28 L
EMD Value
₹56,000
Closing Date
28 Nov 2019, 6:00 pmClosed
GE I NAVY JAMNAGAR
INS NAVY VALSURA JAMNAGAR 361150
REPAIR, MAINTENANCE OF MOTORS, PUMP SETS, VALVE CHAMBERS, WATER LEVEL INDICATORS CLEANING OF UNDERGROUND SUMPS OVERHEAD RESERVOIRS AND OTHER CONNECTED WORKS FOR WATER SUPPLY INSTALLATION UNDER GE I NAVY JAMNAGAR
2019_MES_299564_1
8417
Open Tender
Electrical and Maintenance Works
Item Rate
300 days
GE I NAVY JAMNAGAR
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE I NAVY JAMNAGAR
₹56,000
Yes
18 Jan 2020
20 Nov 2019
30 Nov 2019
20 Nov 2019
28 Nov 2019
23 Nov 2019
20 Nov 2019 - 22 Nov 2019
Amount
Taking down/up the existing submersible pump set of capacity 3 to 5 HP from underground sump, well, transporting to work shop, dismantling the submersible pump set, cleaning descaling and re-assembling after repair / replacement of spareparts including taking out pipe, cable etc. and lowering, fixing at the same/new location complete all as directed. Note: Cost of new spare parts and rewinding shall be measured and paid separately under Sl item No. 5 to 9 & 38.
All as per item No. 1 here in above, but for 7.5 to 10 HP. Note: Cost of new spare parts and rewinding shall be measured and paid separately under Sl item No. 10 to 17 & 39.
All as per item No. 1 here in above, but for 15 to 25 HP. Note: Cost of new spare parts and rewinding shall be measured and paid separately under Sl item No. 18 to 26 & 40.
All as per item No. 1 here in above, but for 30 HP. Note: Cost of new spare parts and rewinding shall be measured and paid separately under Sl item No. 27 to 37 & 41.
Supply only new bearing bush rubber for 3 to 5 HP of submersible pump as per existing type.
Supply only new CI thrust bearing for 3 to 5 HP submersible pump as per existing type.
Supply only new brass thrust plate for 3 to 5 HP submersible pump as per existing type.
Supply only new neck ring brass for 3 to 5 HP submersible pump as per existing type.
Supply only new oil seal for 3 to 5 HP submersible pump as per existing type.
Supply only new bearing bush rubber for 7.5 to 10 HP submersible pump as per existing type.
Supply only new bearing housing for 7.5 to 10 HP submersible pump as per existing type.
Supply only new brass thrust plate for 7.5 to 10 HP submersible pump as per existing type.
Supply only new CI thrust bearing for 7.5 to 10 HP submersible pump as per existing type.
Supply only new CI stage casing for 7.5 to 10 HP submersible pump as per existing type.
Supply only new brass impellers for 7.5 to 10 HP submersible pump as per existing type.
Supply only new CI lower housing for resting of shaft for 7.5 to 10 HP submersible pump as per existing type.
Supply only new CI upper housing for resting of shaft for 7.5 to 10 HP submersible pump as per existing type.
Supply only new CI thrust bearing for 15 to 25 HP submersible pump as per existing type.
Supply only new CI stage casing for 15 to 25 HP submersible pump as per existing type.
Supply only new bearing bush rubber for 15 to 25 HP submersible pump as per existing type.
Supply only new bearing housing for 15 to 25 HP submersible pump as per existing type.
Supply only new brass impellers for 15 to 25 HP submersible pump as per existing type.
Supply only new gun metal pump shaft for 15 to 25 HP submersible pump as per existing type.
Supply only new neck ring brass type for 15 to 25 HP submersible pump as per existing type.
Supply only new key for impellers for 15 to 25 HP submersible pump as per existing type.
Supply only new oil seal for 15 to 25 HP submersible pump as per existing type.
Supply only new CI thrust bearing for 30 HP submersible pump as per existing type.
Supply only new CI stage casing for 30 HP submersible pump as per existing type.
Supply only new bearing bush rubber for 30 HP submersible pump as per existing type.
Supply only new bearing housing for 30 HP submersible pump as per existing type.
Supply only new brass impellers for 30 HP submersible pump as per existing type.
Supply only new neck ring brass type for 30 HP submersible pump as per existing type.
Supply only new key for impellers for 30 HP submersible pump as per existing type.
Supply only new oil seal for 30 HP submersible pump as per existing type.
Supply only new CI lower housing for resting of shaft for 30 HP submersible pump as per existing type.
Supply only new CI upper housing for resting of shaft for 30 HP submersible pump as per existing type.
Supply only new gun metal pump shaft for 30 HP submersible pump as per existing type.
M&L cutting out the burnt winding of all the three phases of stator, for submersible pump set of capacity 3 to 5 HP, taking out burn out copper wire by cleaning the slots properly, re-winding the three phases with original gauge, super enamaled the copper winding wire including insulating material i.e. varnishing, cotton tape, insulating paper, sleeves drying the winding with required temperature re-assembling the rotor and stator after cleaning and dusting of rotor to remove the settled dust particles complete all as directed.
All as per item No. 38 here in above, but for 7.5 to 10 HP
All as per item No. 38 here in above, but for 15 to 25 HP
All as per item No. 38 here in above, but for 30 HP
Disconnecting the single stage split casing centrifugal pumping set / Monoblock pumping set, 40 to 60 HP (any make), separating from sunction, delivery pipeline, electrical connection etc. dismantling the same for overhauling, repairing and replacing the unserviceable spare parts such as gland, packing, bearing bush, washer etc. Painting with one coat of synthetic enamel paint with proper colour codes and writing letters of SM No. and MES No. etc. and installing, making connection suction and delivery side with necessary new packing material, nut bolt etc. complete all as specified and as directed. Note: Cost of new spare parts shall be measured and paid separately under Sl item No. 43 to 51.
All as per item No. 42 here in above, but for the single stage split casing centrifugal pumping set / Monoblock pumping set 10 to 15 HP.
All as per item No. 42 here in above, but for the single stage split casing centrifugal pumping set / Monoblock pumping set 5 to 7.5 HP.
All as per item No. 42 here in above, but for the single stage split casing centrifugal pumping set / Monoblock pumping set 2 to 3 HP.
Supply only new Cast Iron impeller with key for 40 to 60 HP single stage split casing cenrifugal pumping set / monoblock pumping set as per existing type.
Supply only new pump shaft made of EN9 steel for 40 to 60 HP single stage split casing cenrifugal pumping set / monoblock pumping set as per existing type.
Supply only new gun metal bushes with nut for pump shaft for 40 to 60 HP single stage split casing cenrifugal pumping set / monoblock pumping set as per existing type.
Supply only new Cast Iron gland flange with stud for 40 to 60 HP single stage split casing cenrifugal pumping set / monoblock pumping set as per existing type.
Supply only new ball bearing set of two for 40 to 60 HP single stage split casing cenrifugal pumping set / monoblock pumping set as per existing type.
Supply only new love joy coupling for 40 to 60 HP single stage split casing cenrifugal pumping set / monoblock pumping set as per existing type.
M&L cutting out the burnt winding for 40 HP electric induction motor three phase stator, taking out burn out copper wire by cleaning the slots properly, re-winding the same as per original gauge, super enamelled the copper winding wire including insulating material i.e. varnishing, cotton tape, insulating paper, sleeves drying the winding with required temperature re-assembling the rotor and stator after cleaning complete all as specified and as directed.
All as per item No. 52 here in above, but for 10 to 15 HP electric induction motor three phase stator.
All as per item No. 52 here in above, but for 5 to 7.5 HP electric induction motor three phase stator.
All as per item No. 52 here in above, but for 2 to 3 HP electric induction motor three phase stator.
M&L painting to motors, pump sets, MS channels, foundations, suction and delivery pipes of 30 to 60 HP pump sets up to 5m length from pump sets including cleaning the outer surfaces of any description, in any position, applying one coat of synthetic enamel paint with proper colour codes and writing letters of SM No. and MES No. etc., complete all as specified and as directed.
All as per item No. 56 here in above, but for 10 to 25 HP pump sets.
S&F MCCB TP, 250 Amp, 36 kA, 415 V, 50Hz, AC supply in existing panel board with connection & testing as required including taking down existing MCCB complete all as specified and as directed. Make: Legrand Cat No. 4202 39 or an equivalent in Schneider / L&T / ABB / Siemens
S&F MCCB TP, 200 Amp, 36 kA, 415 V, 50Hz, AC supply in existing panel board with connection & testing as required complete including taking down existing MCCB all as specified and as directed. Make: Legrand Cat No. 4202 38 or an equivalent in Schneider / L&T / ABB / Siemens
S&F MCCB TP, 100 Amp, 36 kA, 415 V, 50Hz, AC supply in existing panel board with connection & testing as required including taking down existing MCCB complete all as specified and as directed. Make: Legrand Cat No. 4202 35 or an equivalent in Schneider / L&T / ABB / Siemens
S&F single phase preventer, AC, 415 V including commissioning & testing including taking down existing single phase preventer complete all as specified. Make: Minilec / L&T / C&S
S&F contactors, 50 Amp, TP, 415 Volts and taking out existing unseviceable contractor including electrical connection complete all as specified and as directed. Make: Legrand / Schneider / L&T / ABB / Siemens
S&F contactors, 32 Amp, TP, 415 Volts and taking out existing unseviceable contractor including electrical connection complete all as specified and as directed. Make: Legrand / Schneider / L&T / ABB / Siemens
M&L submersible cable copper conductor size of 3 core, 16 sqmm, flat, multistranded and waterproof including taking down existing cable complete all as specified and as directed.
All as per Item No. 64 here in above, but of size 3 Core, 10 Sqmm
All as per Item No. 64 here in above, but of size 3 Core, 6 Sqmm
All as per Item No. 64 here in above, but of size 3 Core, 4 Sqmm
Supply and lay PVC rigid conduit 40 mm bore for protection of submersible cable in trenches including all necessary fittings and taking down existing PVC rigid conduit complete all as specified and as directed. Note: Earth work and excavation shall measured and paid separately.
S&F motor backlite terminal plate having six terminal as per existing size / shape with copper alloy nuts, bolts and washers for 40/ 60 HP motor including taking down existing terminal plate complete all as specified.
Repairing cast iron sluice valve 80 mm bore flanged type of any make by dismantling the valve, replacing SS spindle, bolts, nuts, washers, gaskets, wedgenut etc, re-assembling and refixing the same in position including replacing the worn out gland packing & testing and make good complete all as specified and as directed.
All as per Item No. 70 above here in, but sluice valve 100 mm bore.
All as per Item No. 70 above here in, but sluice valve 150 mm bore.
All as per Item No. 70 above here in, but sluice valve 200 mm bore.
All as per Item No. 70 above here in, but sluice valve 250 mm bore.
All as per Item No. 70 above here in, but sluice valve 300 mm bore.
Taking down existing sluice valve and S&F sluice valve cast iron body, double flanged and drilled, 80 mm bore as per IS-14846, class PN-1.6, long body type with SS spindle etc with all fittings, jointing materials etc. complete all as specified and as directed.
All as per Item No.76 here in above, but 100 mm bore.
All as per Item No. 76 here in above, but 150 mm bore.
S&F in repairs Non return valve cast iron body with nitrile rubber ball as per IS-5312, class PN-1.6, double flange with reinforced ball suitable for 80 mm bore complete.
S&F in repairs Non return valve cast iron body with nitrile rubber ball as per IS-5312, class PN-1.6, double flange with reinforced ball suitable for 100 mm bore complete.
S&F in repairs Non return valve cast iron body with nitrile rubber ball as per IS-5312, class PN-1.6, double flange with reinforced ball suitable for 150 mm bore complete.
S&F in repairs CI foot valve flanged and drilled type with ISI marked conforming to IS:1538 of 80 mm bore complete all as directed.
S&F in repairs CI foot valve flanged and drilled type with ISI marked conforming to IS:1538 of 100 mm bore complete all as directed.
S&F in repairs CI foot valve flanged and drilled type with ISI marked conforming to IS:1538 of 150 mm bore complete all as directed.
S&F in repair fully automatic DOL motor starter in sheet steel enclosure for 5 to 7.5 HP with SPP feature complete including disconnecting and reconnecting by using proper lugs complete. Make: L&T Cat No. MK2DOL or equivalent in Siemens / Schneider / C&S.
S&F in repair fully automatic star Delta motor starter in sheet steel enclosure for 15 HP with SPP feature complete including disconnecting and reconnecting by using proper lugs complete. Make: L&T Cat No. MK1FASD or equivalent in Siemens / Schneider / C&S.
S&F in repair fully automatic star Delta motor starter in sheet steel enclosure for 25 HP with SPP feature complete including disconnecting and reconnecting by using proper lugs complete. Make: L&T Cat No. MN 25 FASD or equivalent in Siemens / Schneider / C&S.
S&F in repair fully automatic star Delta motor starter in sheet steel enclosure for 30 HP with SPP feature complete including disconnecting and reconnecting by using proper lugs complete. Make: L&T Cat No. MU2FASD or equivalent in Siemens / Schneider / C&S.
S&F in repair fully automatic star Delta motor starter in sheet steel enclosure for 40 HP with SPP feature complete including disconnecting and reconnecting by using proper lugs complete. Make: L&T Cat No. MN 32 FASD or equivalent in Siemens / Schneider / C&S.
S&F in repair submersible motor starter in sheet steel enclosure for 5 HP including disconnecting and reconnecting by using proper lugs complete. Make: L&T Cat No. MU-G6 DOL or equivalent in Siemens / Schneider / C&S.
S&F in repair submersible motor starter in sheet steel enclosure for 10 HP including disconnecting and reconnecting by using proper lugs complete. Make: L&T Cat No. MU-G10H DOL or equivalent in Siemens / Schneider / C&S.
S&F in repair submersible motor starter in sheet steel enclosure for 15 HP including disconnecting and reconnecting by using proper lugs complete. Make: L&T Cat No. MU-G15 or equivalent in Siemens / Schneider / C&S.
S&F in repair submersible motor starter in sheet steel enclosure for 25 to 30 HP including disconnecting and reconnecting by using proper lugs including complete. Make: L&T Cat No. MU-G30 or equivalent in Siemens / Schneider / C&S.
Excavation in trenches and not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation of drain, man hole, laying of cables, stay etc. not exceeding 10 Sq. m on plan and not exceeding 1.5 m depth and getting out in soft / loose soil.
M&L for PCC 1:3:6, type C1 (using 20 mm graded crushed granite stone aggregate) as in coping including necessary form work complete all as directed.
M&L for PCC 1:4:8, type D2 (using 40 mm graded crushed granite stone aggregate) as in foundations, filling and mass concrete complete all as directed.
M&L for brick work with fly ash bricks, straight or curved on plan exceeding 6 m mean radius built in CM 1:4 complete all as specified including demolition of existing brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc and removal of debris to a distance not exceeding 50 mts and depositing where directed.
M&L for rendering 10 mm thick in CM 1:4 on fair faces of brick work or concrete surfaces finished fair and even and finally apply three coats of white wash on plastered surface complete all as directed. Note: Quoted rate shall deemed to be inclusive of three coats of white wash.
M&L M-35 grade, 60 mm thick PVC moulded machine pressed precast concrete interlocking paver block any shape and size with grey cement and pigment conforming to IS: 15658-2006, laid over and including 40 mm thick compacted sand cushion as per manufacturer's instructions complete all as directed..(Note : Quoted rate is deemed to be inclusive of sand cushoining).
Pumping out the water from under ground sump of size 24.80x16.45x5.30 m and capacity 2,00,000 Gallons and remove sludge / mud thoroughly, clean entire portion of sump by scrapping with wire brushes, broom and wash out by flushing clean water and drain out, clean entire inner portion of sump by bleaching powder, and apply one coat of white wash on inner surfaces of sump, at Pump House No.1 including marking the Date of cleaning, due date for next cleaning and capacity of sump etc with painting complete all as specified. Note for Sl item No. 100 to 105: i) Contractor has to make his own arrangements for Pumping out the water from Sump including T&P and necessary safety measures for cleaning of sump. ii) Job is to be carried out in one day.
All as per Item No. 100 here in above, but size of sump 24.40x15.25x4.30 m, and of capacity 1,50,000 Gallons at Pump House No. 1.
All as per Item No. 100 here in above, but size of sump 17.50x15.50x5.50 m, and of capacity 1,25,000 Gallons at Pump House No. 1.
All as per Item No. 100 here in above, but size of sump 16.50x15.50x5.30 m, and of capacity 1,00,000 Gallons at Pump House No. 2.
All as per Item No. 100 here in above, but size of sump 5.90x5.90x2.20 m, and of capacity 10,000 Gallons at NEMCC
All as per Item No. 100 here in above, but size of sump 6.50x6.50x2.20 m, and of capacity 15,000 Gallons at Pump House No. 1 (For RO Plant)
Drain out water from Over Head Tank (OHT) capacity 1,00,000 gallons at 18.3 m height from ground and remove the sludge / mud thoroughly, clean inner surface of the tank by scrapping with wire brush, broom and wash out by flushing with clean water and drain out for OHT No. 6 & OHT No. 3. Note for Sl item No. 106 to 109: i) Contractor has to make his own arrangements for Pumping out the water from OHT including T&P and necessary safety measures for cleaning of OHT.
All as per Item No. 106 here in above, but tank capacity 50,000 gallons at 18.30 m height from ground (OHT No. 1, 2, 5, 7, 9 & 10).
All as per Item No. 106 here in above, but tank capacity 25,000 gallons at 18.30 m height from ground (OHT No. 4).
All as per Item No. 106 here in above, but tank capacity 10,000 gallons at 18.50 m height from ground (OHT No. 8)
Pumping out the water from static water under ground sump capacity 25,000 gallons and remove sludge/ mud thoroughly, clean entire portion of sump by scrapping with wire brushes, brooming and wash out by flushing clean water and drain out, clean entire inner portion of sump by bleaching powder, apply one coat of cement slurry wash to inner surface of sumps, at various location including marking the Date of cleaning and due date for next cleaning and capacity of sump etc by painting complete all as specified. Note for Sl item No. 110 to 113: i) Contractor has to make his own arrangements for Pumping out the water from static water under ground sump including T&P and necessary safety measures for cleaning of static water under ground sump. Location: Valsura area.
All as per Item No. 110 here in above, but for 20,000 gallons.
All as per Item No. 110 here in above, but for 15,000 gallons.
All as per Item No. 110 here in above, but for 10,000 gallons.
M&L valve chamber covers made out FRP cover of required size with FRS frame including fixed with SS hinges, nuts, bolts, etc for fixing V hamper on existing / new fabricated structure including taking down old covers complete all as specified and directed. Note: MS frame structure and other fittings shall be measured and paid separately under Sl item No. 115
S&F Mild steel iron framed work as frame to any size of valve chamber including making hinge , locking arragements etc as ordered including painting the entire expose steel surface with with two coats of first quality synthetic enamel paint over a coat of zinc chromate primer including taking down existing frames etc complete all as specified. Note: Quoted rate shall deemed to be inclusive of painting.
M&L for earthing complete with galvanized steel earth plate as electrode 600x600x6 mm buried directly in ground vertically to a depth not less than 2.25 m below ground level with top edge of earth plate at a depth not less than 1.5 m below ground level connected using galvanized iron earth lead strip 25x4 mm as earthing lead by means of bolts, nuts, check nuts and washers of GI earth lead strip protected by Gl light grade pipe 40 mm bore, including provision of concrete pit of PCC 1:2:4, type B1 (using 20 mm graded stone aggregate) with 40 mm thick cover of RCC 1:2:4 reinforced with 8 mm dia TMT bars reinforced at 100 mm C/C both ways and handle of 6 mm dia MS bar made to shape, GI light grade 20 mm bore pipe for watering perforated at bottom, 2 m long placed on top edge of earth plate, char coal and common salt filling test point made out of 40x8 mm flange with fixing arrangement, funnel, wire mesh and earth work in any type of soil, returning, filling in and removal of surplus soil to a distance not exceeding 50 m all as per electrical Plate No. 3 of SSR Part I and connected to earth test point complete all as specified including testing on completion and including taking down existing earthing complete.
S&F CI/ DI pipe fittings bends (any type, radius and angle) tapers any type, (straight, bend, increasing, decreasing or double socket etc.) Tee pieces single branch. "Y" junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs etc. for 80 mm to 300 mm pipe line including taking down existing old CI/ DI pipe fittings complete.
S&F in repair ammeter digital, panel board mounting square type range 0-200 Amps, CT ratio 200/5 complete.
S&F in repair Volt meter digital type, panel board mounting square type range 0-500 V complete.
S&F in repair gland packing rope with lead graphite type of size 6 mm to 40 mm.
M/s Jagdish Machinery Stores
JAMNAGAR ELECTRIC AND MACHINERY CO
Prime Decor
suvidhiconstruction
M/S Badri Electicals
Jyoti Refrigeration
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .