Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.7 LAccepted-Finance B 80 ANAND VIHAR ANAND VIHAR EAST DELHI DELHI 110092 | EAST DELHI | DELHI | 110092 | L1 | Accepted-Finance OK | |
| 2 | L2₹18.4 L+₹71,430.80 (4.03%)Accepted-Finance 12 GURU NANK AUTO MARKET KASHMERE GATE DELHI 110006 | NORTH | DELHI | 110006 | L2 | Accepted-Finance OK | |
| 3 | Rejected-Technical | - | Rejected-Technical DUE TO NOT FULL FILL TECHNICAL CRITERIA |
Tender Value
Refer Docs
EMD Value
₹36,000
Closing Date
7 Jun 2021, 12:15 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EE
WAZIRABAD WATER WORKS TIMARPUR DELHI
Renovation/Repairing of Krohne Marshall Make flow Meters installed at Jahangir Puri, Kewal Park, Gulabi Bagh, Burari BPS, Subhash park Old and New under the command of Wazirabad water works ( Re-Invited).
2021_DJB_203249_2
PRESS NIT NO.2(2021-22)WW-II
Open Tender
Miscellaneous Works
Works
120 days
WAZIRABAD WATER WORKS TIMARPUR DELHI
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
DJBEMD A/c No-50448339804 THROUGH SUBPAISA GATEWAY
₹36,000
Yes
24 Jun 2021
10 May 2021
7 Jun 2021
10 May 2021
7 Jun 2021
10 May 2021
10 May 2021 - 7 Jun 2021
120 days
Renovation/Repairing of Krohne Marshall Make flow Meters installed at Jahangir Puri, Kewal Park, Gulabi Bagh, Burari BPS, Subhash park Old and New under the command of Wazirabad water works. Supply of Flow Indicator Totalizer with RS 485 output with enclosure. Make: Scan/Apurv/MTL.
Supply of Lighting protection unit (LPU) use for signal. Make: Spink-CITEL/Finder/MTL.
Supply of Lighting protection unit (LPU) use for power. Make: Spink-CITEL/Finder/MTL.
Supply of 700 VA Inverter with 60 AH maintenance free battery. Make: Microtek/ SuKam/ Amaron.
Supply of 32 A TP MCB C Curve. Make: L&T/ABB/Schnieder.
Supply of DS Signal Cable 2 core X 2.5 Sq mm for flow meter data transfer. Make: Aditya/ DC/Krohne/Siemens.
Supply of power cable 3CX1.5 Sq. Mm PVC insulated, copper conductor. Make:-DC/Aditya/Spink/Gloster/Grandlay/DJB approved.
Supplying of main transmitter Double Door panel made out of 16 SWG MS sheet 1000X800X400 mm approx to accommodate the following items duly powder coated in approved colour with louvers for ventilation, locking and lifting arrangement, suitable for fixing of Transmitter, 700 VA inverter and 60 AH maintenance free Battery etc complete as required.
Dismantling the existing defective material i.e. Transmitter, LPU, MCB etc. from the old panels after disconnecting power supply/connections etc as per site requirement.
Installing the new panel, including making of foundation for same.
Fixing the new material in the panel as per site requirement and making the wiring connections along with complete thimbling / tapping etc. as per site requirement. #Note-Flow Transmitter will be provided by the department free of cost.
Synchronizing Flow transmitter, Flow Tube/sensor and FIT for accurate flow data/readings.
Excavation of the Pipe/cable trenches in hard rock not exceeding 1.5 metres in width, and lift upto 1.5 metres, including getting out the excavated soil and disposal of excavated soil as directed within a lead of 50 metres. DSR No. 14.6
Laying of one number PVC insulated and PVC sheathed / XLPE power/Signal cable of 1.1 KV grade of following size in the existing PVC/steel pipe as required. Upto 35 sq. Mm DSR No. 7.5.1
Supplying and fixing of following sizes 20 mm of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. DSR No. 1.21.1
Supplying and fixing of following sizes 20 mm of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. DSR No. 1.20.1
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. DSR NO. 5.2
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in Recess for connections etc. as required. DSR NO. 5.15
Installing LPU to protect flow tube and Transmitter.
Testing & Commissioning the panel after completing the above work.
Agarwala Traders
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .